Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC 205 2ND FLOOR VIPUL SQUARE B BLOCK SUSHANT LOK 1 GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹13.5 L+₹17,000 (1.27%)Rejected-Finance | L2 | Rejected-Finance Quoted rate higher than L1 bidder |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
19 May 2021, 3:00 pmClosed
CWE
HQ 137 Wks Engrs
PROVN OF COMPLETE LAUNDRY MACHINE AT 154 GH IN ZAKHAMA MIL STN
2021_MES_435548_1
8573/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Zakhama
Class E
Category c v
2 documents required · 2 mandatory
₹500
AGE (I) Zakhama
₹28,000
21 Jun 2021
10 Apr 2021
21 May 2021
10 Apr 2021
19 May 2021
24 Apr 2021
Amount
Supply and installation of front loading washer extractor, high spin, dual suspension technology ( spring suspension on top and shock absorber/ spring suspension on bottom), full stainless steel outer body, inner basket & outer drum of SS304 Grade, fully programmable PLC controlled, LCD display including all relevant accessories, safety features with fwg specification:- (a)Steel Grade- SS 304 (b) Motor- 7.5 HP with VFD ( minimum) (c) In built MCB (d) Basket Size - 840 x 550 mm (12 gauge) or as per OEM (e) Basket Volume - 305 ltrs minimum (f) Motor Speed - 35 to 40 RPM (g) Extracting Speed - 750 RPM to 800 RPM (h) G Force - 301 to 355 KGF (j) Water inlet connection - 1/ 2 Inch (k) Dimensions - 1280 x 1300 x 1750 mm or as per OEM (l) Weight - 1200 kgs appx (m) Inner Basket - 14 Gauge (Dimple Hole) (n) Dosing - Fully Automatic 5 Pockets; (o) Power Supply - 415V, 3Phase, 50 Hz AC (p) Heating Elements -18 KW complete all as specified and as directed. Make :Ramsons laundry, Model No RVWE 30 or equivalent make as approved by AGE(I).
Supply and Installation of Tumbler Drier, Front Loading, automatic reversible, PLC controlled with 5 program storage capacity including all relevant accessories, safety features with fwg specification:- (a) Drive Motor - 0.75 kw (minimum) (b) Blower/ Exhaust Motor - 1.0 kw (minimum) (c) Steel Grade - SS 304 (d) Pully Taper Bush Heavy Duty (e) Drum Size - 970 x 830 mm (f) Drum Volume - 613 ltrs (g) Exhaust Size - 150 mm x 150 mm (appx) (h) Complete insulated body (j) Outer Dimensions - 1050 x 1320 x 1870 mm (k) Weight - 550 kgs minimum (l) Main Door Open - 750 mm appx (m) Heater Load - 24 kw minimum complete all as specified and as directed. Make : Ramsons laundry, Model No RTD 30 or equivalent make as approved by AGE(I).
Supply and Installation of Electric Steam Generator for continuous steam supply for vacuum ironing tables including all relevant accessories, safety features with fwg specification:- (a) steam output: 27 kg/hr (appx) (b) Operating pressure: 5.0 bar (c) Water capacity: 18 ltrs (appx) (d) Water pump: 1 Hp (minimum) (e) Heater : 12kw (Minimum) (f) water inlet and steam outlet : 0.5 Inch (g) Dimension: (w x d x h) : 356x x 737 x838 mm complete all as specified and as directed. Make : Ramsons laundry, Model No MR 12 or equivalent make as approved by AGE(I).
Supply and Installation of Vaccum ironing table with press, single phase /three phases, powder coated outer body with side Iron stand, silicon ironing pad, and full-length footpedal switch control, steam ironing control with thermos including all relevant accessories, safety features with fwg specification:- (a) Vaccum motor- 0.75 hp (b) working size- 1300 x 800mm (c) working area hieght- 800mm (d) size- 1300 x 800mm complete all as specified and as directed. Make : Ramsons laundry, Model No RV 4425-80 with Italion Iron madel No 2128 or equivalent make as approved by AGE(I).
Materials and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip 20x3mm by means of nuts, bolts, check nuts and washers made of copper, earthing lead to be protected by galvanised iron pipe of 32mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Lucky Engineering Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .