Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 16 20 GALI NO 7 8 SWAROOP NAGAR EXTENSION DELHI 110042 | DELHI | NORTH DELHI | DELHI | 110042 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹3.5 L+₹77,535 (28.7%)Rejected-AOC | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹3.6 L+₹85,815 (31.7%)Rejected-AOC | L3 | Rejected-AOC Other than lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
5 Jun 2023, 6:00 pmClosed
Noida
AGE I CG Noida
REPAIR TO ELECTRIC WATER GEYSERS and SOLAR WATER HEATERS IN OTM ACCN AND MD ACCN AT COAST GUARD STATION NOIDA
2023_MES_593625_1
AGE I CGN 25 23 24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Noida
E b i
7 documents required · 7 mandatory
₹500
AGE I CG
₹10,000
13 Jul 2023
8 May 2023
7 Jun 2023
8 May 2023
5 Jun 2023
22 May 2023
Amount
Note : (a). Once the geyser is down off then it shall be inspected by deptt and may order major repair/replacement of any part which shall be paid seperately .(b) Any damage if occurred during the process of cleaning the geyser will be made good by contactor at no extra cost.(c) A proper bound register shall be maintained showing details of repair /replacement , date of taking off , date of refixing . This register shall have signature of contractor , MES Rep and Rep of User .A Geyser after taking off shall be refixed on the day when it was taken off unless ordered for painting /major repair/replacement of parts. In this case the geyser shall be refixed within 48 hours from taking off failng which a recovery of Rs 100.00 per day or part thereof shall be deducted from contractors dues.(d) No Extra cost for transport will be paid for repairs to Market. (e) Painting of geyser and major repairs shall be carried out in a place at sec 23 Noida (f) Contractor will provide 50% of Sch, material within 10 days of commencement of work, or all as directed by Engr in Charge.
Taking down electric water heater/geysers of capacity 25/35/50 ltrs and of any make from its mounting place , opening it for descaling /cleaning of inner tank from deposited scales with descaling solution including checking leak ,testing,sealing of joints, carrying out the minor repair on surface of outer body, bottom and top cover,and re-fixing the geyser in same posn Complete all as directed.
M & L for Painting of geysers of any type, make and capacity 25 L with one coat of white paint (spray painting) super enameled white paints after removing of old paints, making smooth surface and marking MES number with black paint in capital letters including providing new PVC ring as per existing PVC ring complete all as specified and as directed by Engr-in-Charge.
M & L for Painting of geysers of any type, make and capacity 50 L with one coat of white paint (spray painting) super enameled white paints after removing of old paints, making smooth surface and marking MES number with black paint in capital letters including providing new PVC ring as per existing PVC ring complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of geyser element of 1.5 KW rating double tube type with cup type or circular/triangle shape including rubber washers suitable to fit in the existing geyser without any water leakage complete all as specified and as directed by Engr-in-Charge . Make : Micron King/Bajaj/Recold/thita/havells.
S&F in replacement of Ceramic heating element of 2 KW rating round long rod shape (construction of element on Ceramic) complete all as specified and as directed by Engr-in-Charge. Make : Micron King/Bajaj/Recold/thita/havells.
S&F in replacement of the Gasket (heat proof rubber) for apparatus plate suitable for the different make of 25 /35/50 litres capacity geysers as per site requirement complete, all as specified and as directed by Engr-in-ChargeMake as per existing or compatible as approved ISI marked
S&F in replacement of heavy duty element holding assembly/ apparatus plate made out of copper and chromium plate( different 6/9 hole or as per site requirement ) with provision for safety valve in its inlet and outlet, pocket for thermostat/ thermal cut system and drain plug all as per site requirement and directed by engineer in charge suitable for 25 litres capacity geysers. Make as per existing or compatible as approved ISI marked
S&F in replacement of heavy duty element holding assembly ( different type hole or without hole) with provision for safety valve in its inlet, pocket for thermostat/ thermal cut system and drain plug all as per site requirement and directed by engineer in charge suitable for 50 litres capacity geysers. Make : Make as per existing or compatible as approved ISI marked
S&F stainless steel inner tank heavy duty in replacement of steel inner tank having pressure bearing capacity 6 Kg/Cm.sq. suitable to the existing 25 ltrs capacity geysers. Complete with Nut Bolt and washer, all as specified and as directed by Engr-in-Charge. Note : Only OEM manufacture SS tank will be accepted.
S&F stainless steel inner tank heavy duty in replacement of steel inner tank having pressure bearing capacity 6 Kg/Cm.sq. suitable to the existing 50 ltrs capacity geysers.Complete, all as specified and as directed by Engr-in-Charge. Note : Only OEM manufacture SS tank will be accepted.
S&F in replacement the thermostat 7'' long for the geysers 25 Ltrs. capacity as per site requirement complete, all as specified and as directed by Engr-in-Charge. Make Bajaj/Digits/Recold/DASS PASS/THETA/Micron King
S&F in replacement the thermostat 11'' long for the geysers 25/35/50 Ltrs. capacity as per site requirement complete, all as specified and as directed by Engr-in-Charge. Make Bajaj/Digits/Recold/DASS PASS/THETA/Micron King
S&F in replacement of Multiple use safety valve / PRV 15mm, bore for geyser inlet or all as specified and as directed by Engr-in-Charge .Make as per existing or compatible as approved ISI marked
Supply and fixing in replacement of the insulating material all as specified and as directed by Engr-in-Charge . Make: as per existing or compatible as approved ISI marked.
S&F in replacement steel ribbed connection pipe 450 mm long heavy duty (Hot water) with two brass nut and nylon washer suitable for 15mm dia inlet and outlet pipe of geyser and connecting up complete, all as specified and as directed by Engr-in-Charge . Make : Theeta or as per existing or compatible as approved ISI marked
S&F in replacement steel ribbed connecting pipe 600 mmlength heavy duty (Hot water) with two brass nut and nylon washer suitable for 15mm dia inlet and outlet pipe of geyser and connecting up complete, all as specified and as directed by Engr-in-Charge . Make as Approved ISI marked
S&F in replacement of 1100 Volt grade cable flexible 3 core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm ISI mark Plaza/Havells/Polycab.
S&F in replacement of metal plug top 2 pole and earth 240 volts complete all as specified and as directed in Engr–in- Charge . Make: Havells/Snider/Plaza/ Strandard
S&F in replacement of metal Socket 2 pole and earth 240 volts complete all as specified and as directed in Engr–in- Charge . Make: Havells/Snider / Plaza/ Strandard
S&F in replacement of bottom cover made of M S sheet 20 SWG duly painted with two coats of super enamel paint by spray painting complete all as specified and as directed in Engr–in- Charge suitable for 25 ltrs geysers. Make as per existing or compatible as approved ISI marked
S&F in replacement of top cover made of M S sheet 20 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 ltrs geysers. complete, all as specified and as directed by Engr-in-Charge .Make as per existing or compatible as approved ISI marked
S&F in replacement of indicating lamp Red or Green as per Geyser suitability complete all as specified and as directed by Engr-In-Charge Make as per existing or compatible as approved ISI marked
Supply and fix in replacement of outer body made/fabricated of 20 SWG MS sheet for Geysers of 25 ltrs capacity duly painted with spray paint with clamps 2 Nos of size 15mmx1mm thick with necessary nut and bolts complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of MCB SP 20A ,10KA, 230 Volts 50 Hz complete.
S&F in repair sheet metal enclosures with socket single pole and netural with a two pin and earth plug socket complete with one single pole MCB of rating 20 Amp 10 KA of Make as directed in Engr – in- Charge. Make: Havells/Plaza/ Strandard
M&L for removing unserviceable grouted Anchor type bolt & nuts from the wall and S&F new ‘Anchor’ type bolts & nuts (Set of 4 bolts of 12mm dia 100mm long with nuts & washers) into the wall grouted properly to hold the water storage type electric geyser of 25/50 ltr capacity and making good the disturbed surface as original all as directed.
M & L in replacement Geyser Heating Element assembly 2000 watt (in Round Shape bottom Assembly) with arrangement of 6 Nut bolt, One no suitable round rubber gasket including one magnesium Rod as required in Bajaj Geyser of Model No CALDIA 25 (150756) complete all as directed. Make Bajaj/Recold/Theeta (As per Sample held with AGE I office).
S&F in replacement Magnesium anode Shakti verticle and Cadila 25 Ltr models complete all as directed by Engr in Charge.
S & F in replacement of geyser heating element suitable for Recold make geyser of capacity 25 Ltrs including nut,bolt,washer etc complete all as specified and directed. Make: Racold or as per existing sample.
S & F in replacement of geyser therostat suitable for Recold make geyser of capacity 25 Ltrs including nut,bolt,washer etc complete all as specified and directed. Make: Racold or as per existing sample.
Servicing and cleaning of collector solar plate panel including copper tubes, MS plate etc complete, all as specified and directed.
S & F in repairs glass tubes suitable for solar tube type collector of solar water heating system 200 LPD all as specified and directed.
S&F in repair 15mm bore stop valve fancy type of cast copper alloy chromium plated screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified and directed.
Disconnecting & taking down the existing unserviceable water tank and Supply and fixing in replacement 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S & F in repair Tubes, 'Medium grade' galvanised, of size 15 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors
S & F in repair Tubes, 'Medium grade' galvanised, of size 25 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors
M/S BEE ESS ENTERPRISES
TIRUPATI ENGINEERS AND CONTRACTOR
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .