Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.9 L+₹4.6 L (22.4%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹28.8 L+₹8.4 L (41.3%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹32.7 L+₹12.3 L (60.3%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹33.9 L+₹13.5 L (66.5%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR / MAINT / REPLACEMENT AND IMPROVEMENT WORK OF LT CABLES, CABLE JOINTS, LT OVERHEAD DISTRIBUTION SYSTEM, VARIOUS SERVICES CONNECTIONS AND DISTRIBUTION SYSTEMS AND OTHER CONNECTED WORKS IN DOMESTIC AREA AT AFS KANPUR
2022_MES_527589_1
8563/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (AF) E/M CHAKERI
₹70,000
Yes
8 Jul 2022
31 May 2022
1 Jul 2022
31 May 2022
29 Jun 2022
15 Jun 2022
60 days
Amount
Excavation in trenches by mechanical means, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
M&L for dry Ganga Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose.
M&L for well burnt brick sub class 'B' old size laying in trenches for cable protection complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HV type 1, flat, size 300mmx180mmx40mm complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 45 cm in width & not exceeding 90 cm in depth for passing of cable and making good of disturbed surface to match with the existing surface complete all as specified and directed.
M&L for making horizontal boring not exceeding 90 cm deep below road crossing for passing of cable complete all as specified and directed.
Taking out from trenches/duct/floor/wall/roof/under road/drain or hardstanding etc. old existing underground XLPE aluminium conductor LT cable for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed:- Size of cable- 2 to 4 core x 10 sqmm to 16 sqmm.
All as per item No. 9.00 above but of size 3.5/4 core x 25 sqmm to 50 sqmm.
All as per item No. 9.00 above but of size 3.5 core x 70 sqmm to 120 sqmm.
All as per item No. 9.00 above but of size 3.5 core x 150 sqmm to 185 sqmm.
All as per item No. 9.00 above but of size 3.5 core x 240 sqmm to 400 sqmm.
Re-laying only or fixing or passing through pipe, in Pole/duct/trench/under road/hardstanding/wall/roof etc. 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed old serviceable cable after checking of any type of faults (if any) by inspection / using equipment / meggering as required by providing lugs/thimbles/glands by compression arrangement complete all as specified and directed. Size of cable - 2 to 4 core x 10 sqmm to 16 sqmm.
All as per item No. 14.00 above but of size 3.5/4 core x 25 sqmm to 50 sqmm.
All as per item No. 14.00 above but of size 3.5 core x 70 sqmm to 120 sqmm.
All as per item No. 14.00 above but of size 3.5 core x 150 sqmm to 185 sqmm.
All as per item No. 14.00 above but of size 3.5 core x 240 sqmm to 400 sqmm.
Supply, laying, testing and commissioning of LT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sq mm 2 core laid in trenches/duct / laid on wall etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed. Make :- Havells / Polycab / Gloster Cables Ltd.
All as per item No. 19.00 above but size 10 Sqmm 4 core.
All as per item No. 19.00 above but size 16 Sqmm 4 core .
All as per item No. 19.00 above but size 25 Sqmm 3.5 core.
All as per item No. 19.00 above but size 35 Sqmm 3.5 core .
All as per item No. 19.00 above but size 50 Sqmm 3.5 core.
All as per item No. 19.00 above but size 70 Sqmm 3.5 core.
All as per item No. 19.00 above but size 95 Sqmm 3.5 core.
All as per item No. 19.00 above but size 120 Sqmm 3.5 core.
All as per item No. 19.00 above but size 150 Sqmm 3.5 core.
All as per item No. 19.00 above but size 185 Sqmm 3.5 core.
All as per item No. 19.00 above but size 240 Sqmm 3.5 core.
All as per item No. 19.00 but size 400 Sqmm 3.5 core. Note for Item No. 19.00 to 31.00: The cable at various location shall be of varying lengths i.e. in pieces of different lengths as per requirement at site and are not necessarily to be laid in one go.
Supply and laying in trenches/Floor or fixed to Pole/Wall in replacement 40 mm bore GI pipe light grade with fitting for protection of cable including dismantling existing pipe complete all as specified and directed. Make :- Jindal / Tata / Prakash Surya.
All as per item No. 32.00 above but of size 50 mm bore.
All as per item No. 32.00 above but of size 80 mm bore.
All as per item No. 32.00 above but of size 100 mm bore.
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in LT / HT cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed. (Note : The Item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. It is solely bidder's responsibility to arrange fault locating machine & he should'nt expect facilitation from the dept. for the same.)
M&L for replacement of Straight through joint kit suitable for XLPE under ground cable of size 25-50 sqmm 3.5 core complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 37.00 above but of size 70-150 sqmm 3.5 core.
All as per item No. 37.00 above but of size 185-240 sqmm 3.5 core.
All as per item No. 37.00 above but of size 300-400 sqmm 3.5 core.
M&L for Earthing (in replacement) complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 m below the ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI strip 32 x 6 mm size as earthing lead filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) alongwith lifting handle complete all as specified and directed. (GI strip upto 7.5 m length is included in unit rate quoted by contractor).
All as per item No. 41.00 above but Copper earthing with copper plate 600 mm x 600 mm x 3.15 mm thick electrode and 20 x 3 mm copper strip as earthing lead complete all as specified and directed.
All as per item No. 41.00 above but Chemical earthing with copper earth plate 900 mm x 600 mm x 5 mm & copper earth strip 32 x 6 mm complete all as specified and directed.
Taking out from trenches / duct / floor / wall / roof / under road / drain or hardstanding etc. old existing underground XLPE aluminium conductor HT cable of size upto 120 sqmm 3 core for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed.
Supply, laying, testing and commissioning of HT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 11KV grade with stranded aluminium conductor of size 120 sqmm 3 core laid in trenches/duct / laid on wall etc. including suitable size lugs, thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed. Make :- Havells / Polycab / Gloster Cables Ltd.
M&L in replacement of Straight through joint kit with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 120-185 sqmm 3 core all including testing complete all as specified and directed. Make: Raychem / 3M / Denson.
M&L in replacement of End termination joint kit with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 120-185 sqmm 3 core including testing complete all as specified and directed. Make: Raychem / 3M / Denson.
Surface dressing 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 metre outside the periphery of area complete all as specified and directed.
Dismantling of ACSR conductor of any sizes & length and removing the same from the site complete all as specified and directed.
Dismantling of Earth wire of any sizes & length and removing the same from the site complete all as specified and directed.
Dismantling of insulators of any type, any sizes and at any location complete and removing the same from the site complete all as specified and directed.
Restriging of exisiting ACSR conductor / GI wire of any size / any no. conductor including opening of winding wire of ACSR conductor with insulator and winding with new aluminium winding wire and replacement of old jumper wires with new ACSR conductor complete all as specified and directed.
M&L for Aluminium conductor, steel rainforced (ACSR) of existing size & length as per site requirement complete all as specified and directed.
M&L for Galvanised steel wire 4 mm dia earth wire of existing size & length as per site requirement complete all as specified and directed.
S&F Pin type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel spindle, two galvanazed iron washer and one galvanazed nut, 100mm height, 65mm dia 1100 Volts grade complete all as specified and as directed.
S&F Shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps 31x3 mm, washers, insulator bolts 12 mm dia, 75 mm height, 90 mm dia & working pressure in 1100 volts complete all as specified and directed.
M&L for erection and replacement of stay assembly (wire size 7/4 mm) with stay rod 16 mm dia & insulator loop type with nuts, bolts and washers stay wires size 7/4 mm, Flat iron clamps, Nuts, bolts and washers including necessary excavation, removal of soil, refilling of soil, PCC 1:3:6 work, plinth protection complete all as specified and directed.
S&F in replacement of PVC Line separator suitable for 02 / 03 nos over conductor with nuts, bolts and washers complete all as specified and directed.
S&F in replacement of PVC Line separator suitable for 04 / 05 nos over conductor with nuts, bolts and washers complete all as specified and directed.
M&L for preparing old painted surfaces of steel tubular sizes 9 metre long pole structure and applying one coat of aluminium paint with 3 strips of blue paint after scratching of old paint, cleaning of all rusted portion & writing numbering on pole complete all as specified and directed.
M&L for removing old paint from LT panels by paint remover, cleaning by scrapping and preparing the surface and applying two coats of synthetic enamel paint of approved shade over one coat of red oxide primer and writing work as per existing pattern complete all as specified and as directed.
Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of timber complete without dismantling of ACSR conductor complete all as specified and directed.
Receiving complaints from complaint Section / JE / Engr-in-charge by any mode of communication & attending the same within 2 hours. This item is inclusive of all the preliminary work like opening of connections, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues including removing carbon deposits (if any), cleaning of lugs/glands etc., meggering of cables, making temporary connections (as required), removing soil and restoring back the power supply complete all as specified and directed. Note:- The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 2 Hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 10,000 /= per day shall be recovered from contractor's payment.
Supply, laying, testing and commissioning of unarmoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor twin core of size 10 sq mm laid on wall/pole etc. including suitable size lugs, thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed.
S&F in replacement of On Load Changeover with sheet steel enclosure fixed over wall / panel etc. of rating 400 Amps, 415 Volts, 4 pole with complete all as specified and directed. Make - L&T / Havells / Schneider / ABB.
All as per item No. 65.00 above but of rating 200 Amps.
All as per item No. 65.00 above but of rating 100 Amps.
M&L for Shifting of Panel / Transformer / HT Switchgear / RMU to a distance upto 5 KM from power house/substation / any place to the required place, including disconnecting and necessary connection and testing after shifting complete all as specified and directed.
S&F in replacement of steel tubular swaged poles 9.00 m long type 410 SP-31 complete with cast iron base plate, final taper plug, bolts, nuts & screws etc. including necessary earth work, PCC foundation PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete for poles and coping with PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) and making connections complete all as specified and directed.
S&F in replacement of street light junction box 225 mm x 295 mm x 122 mm comprising of 4 nos of aluminium bus bars of suitable rating mounted on epoxy insulators with holes for incoming and outgoing cables, 2 Nos of MCB 16 A SPN, 2 nos cable gland and provision for inserting wires with suitable mounting arrangement on street light pole with MS clamps junction box having IP 55 protection complete all as specified and directed.
S&F in replacement of street light timer including testing and commissioning of NATURE Switch for outdoor lighting automation using space grade sensors, micro controller suitable for outdoor use IP 55 having features Automatic Switching ON at Sunset, Automatic Switching OFF at dawn, No clock setting and time settings wide operating voltage range, high voltage trip and auto reset having specification 230 Volts, 50 Hz with all connected accessories 3 phase complete all as specified and directed.
S&F in replacement of MCCB 630 Amps 36 KA, 4 Pole adjustable over load setting with thermal magnetic release including lugs, nut, bolts, washers, studs, links etc. and testing and commissioning complete all as specified and directed. Make:- L&T / Legrand / ABB / Siemens
All as per item No. 72.00 above but MCCB of rating 400 Amps 36 KA, 4 Pole.
All as per item No. 72.00 above but MCCB of rating 200- 250 Amps 36 KA, 4 Pole.
S&F in replacement of ACB 1600 Amps 50 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers etc. and testing and commissioning complete all as specified and directed. Make of ACB :- L&T / Legrand / ABB / Siemens
All as per item No. 75.00 above but ACB of rating 800 Amps.
VEE KAY ENTERPRISES
BHATIA ENTERPRISES
PAWAN COOL CORPORATION
SAKSHAM SUPPLIERS BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .