Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC 19 TAGORE PUBLIC SCHOOL COMPLEX SEWLA SARAI MALOOK CHAND GWALIOR ROAD AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹48.7 L+₹4.5 L (10.1%)Rejected-Finance DAULAT NAGAR SOHALLA ROAD AJIJPUR DHANOLI AGRA UP PIN 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being higher bidder |
| Sl No | Description | Qty | Unit | aman construction & general suppliers L2 | M/s Srijan Construction Company L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, and removal of debries to a distance exc 1.5 Km but not exc 5.0 Km complete all as specified and directed. | 1,900 | Sqm | 20 ₹38,000 | 10 ₹19,000 Lowest |
| 2.00 | M&L for rendering 15mm thick in two layers of 10+5mm in cm1:4 mixed with Pidi proof 101 LW(+) or Dr fixit or equivelent intergral water proofing admixture:- @ 200ml/bag over two coats of super latex 302 of Dr fixit or equivelent in the ratio (1:4:7) (One part super latex, 4 part water and 7 parts of cement). @ 1.50 Kg of homogenious mixture/sqm in two coats and finish the surface even and smooth without using extra cement) for external walls complete as specified and directed.
Note: Pidi proof and super latex will not be paid separately. | 1,500 | Sqm | 220 ₹3,30,000 | 200 ₹3,00,000 Lowest |
| 3.00 | M&L for preparation of new surface of walls (external surfaces) and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , as per manufactures instructions etc complete all as specified and as directed. | 750 | Sqm | 90 ₹67,500 | 70 ₹52,500 Lowest |
| 4.00 | M&L for Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed. | 1,100 | Sqm | 60 ₹66,000 | 25 ₹27,500 Lowest |
| 5.00 | M&L for rendering 15mm thick in cement mortar 1:6 on other than fair faces of brick work/concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and directed. | 350 | Sqm | 210 ₹73,500 | 180 ₹63,000 Lowest |
| 6.00 | M&L for rendering 10 mm thick CM 1:3 on concrete surfaces in ceilings complete all as specified and directed. | 50 | Sqm | 240 ₹12,000 | 175 ₹8,750 Lowest |
| 7.00 | M&L for preparation of new surfaces of walls and applying two coat of oil bound distemper white or tinted all as directed. | 350 | Sqm | 50 ₹17,500 Lowest | 50 ₹17,500 Lowest |
| 8.00 | M&L for preparation of newely plastered surface of ceiling and applying two coats of white wash complete all as specified and directed. | 50 | Sqm | 250 ₹12,500 | 20 ₹1,000 Lowest |
| 9.00 | Demolition of brick work or stone/boulder masonary,built in cement mortar incl all quions,pillars etc. complete all as specified and directed. | 3 | Cum | 300 ₹900 Lowest | 500 ₹1,500 |
| 10.00 | M&L for brick work with sub class 'B' bricks ,straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. | 3 | Cum | 6,500 ₹19,500 | 5,000 ₹15,000 Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
3 Mar 2026, 6:00 pmClosed
GE TECH AREA AGRA
Military Engineers Services Garrison Engineer (AF) Tech Area Agra - 282008
REPAIR AND MAINT OF SEEPAGE AT CERTAIN ANNEX UNDER AREA OF AGE B/R-I OF GE (AF) TECH AREA AT AF STN AGRA
2026_MES_750967_1
8200-1775/E8
Open Tender
Civil Works - Others
Item Rate
180 days
AF TECH ATREA AGRA
Class D and above category a (i)
8 documents required · 8 mandatory
₹500
Yes
GE TECH AREA AGRA
₹88,000
Yes
31 Mar 2026
11 Feb 2026
7 Mar 2026
11 Feb 2026
3 Mar 2026
25 Feb 2026
Amount in (Rs)
Old Iron Scrap
Old bricks
Old unserviceable galvalume /steel sheeting of any description
AGE (Contracts)
Item Rate
Item Description
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, and removal of debries to a distance exc 1.5 Km but not exc 5.0 Km complete all as specified and directed.
M&L for rendering 15mm thick in two layers of 10+5mm in cm1:4 mixed with Pidi proof 101 LW(+) or Dr fixit or equivelent intergral water proofing admixture:- @ 200ml/bag over two coats of super latex 302 of Dr fixit or equivelent in the ratio (1:4:7) (One part super latex, 4 part water and 7 parts of cement). @ 1.50 Kg of homogenious mixture/sqm in two coats and finish the surface even and smooth without using extra cement) for external walls complete as specified and directed. Note: Pidi proof and super latex will not be paid separately.
M&L for preparation of new surface of walls (external surfaces) and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) , as per manufactures instructions etc complete all as specified and as directed.
M&L for Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on other than fair faces of brick work/concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick CM 1:3 on concrete surfaces in ceilings complete all as specified and directed.
M&L for preparation of new surfaces of walls and applying two coat of oil bound distemper white or tinted all as directed.
M&L for preparation of newely plastered surface of ceiling and applying two coats of white wash complete all as specified and directed.
Demolition of brick work or stone/boulder masonary,built in cement mortar incl all quions,pillars etc. complete all as specified and directed.
M&L for brick work with sub class 'B' bricks ,straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Dismantling of AC/fibre/steel sheets and the like (corrugated/semi corrugated/plain) in roof covering incl ridge all as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa(150GSM) as in roof covering/cladding to wall,fixed with self tapping screws as specified.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 1.00mm thick of an colour having tensile strength of 550MPa as in roof covering/cladding/valley gutter to wall,fixed with self tapping screws as specified.
Demolition of cement concrete (unreinforced) in ground floor and paving of any thickness (below or above ground level) complete all as specified and as directed
M&L for 100mm thick PCC (1:3:6) type B2 using 20mm graded stone aggregate as in sub base of floor,plinth protection etc complete all as specified and as directed
M&L for 50 mm thick PCC 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in flooring in leveling course complete all as specified and as directed
Dismantling of existing roof treatmentof any type description incuding tarfelt/cement plaster etc from roof surfaces including cleaning the surface and removing the debris from site complete all as specified & directed.
M & L for Cutting out cracks to V-section in existing roofs or terracing, cleaning grouting with cement and sand slurry 1:3 complete all as specified & directed.
M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggegate) (average 50 mm thickness) as in levelling course / padding over roof complete all as spd and directed.
M&L for rendering or bedding layer 15mm thick in cement mortar 1:4 on concrete surfaces with WPC @ 3% by weight of cement or as per manufacturer's , finished even and fair with out using extra cement complete as in roof. (WPC shall be measured & paid seperately.
Supply only water proofing compound ISI marked.
M&L for cleaning surfaces and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/Sqm including cleaning surface complete all as specified & directed.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified complete all as specified and as directed.
M&L Cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed; laid over 20 mm thick screed beding in cement mortar (1:4) , set jointed and pointed in neat cement slurry in floors, and cut and polished etc complete all as specified and as directed.
M&L for preparation of roof surface and application of Dr fixit roofseal first coat of primeseal with 50% dilution, adequate time for drying. 1st coat of Dr fixit roofseal ultra undiluted. A glass fiber mesh of 2.5mm x 2.5mm needs to be sandwiched between the first coat and second coats. Then 2nd coat of Dr fixit roofseal ultra is applied to the first coat @ 1.4 ltrs/Sq mtr. Note:- work will be completed at various location in patch repair basis, glass fiber mesh will be paid separately.
M&L for glass fiber mesh of 2.5mm x 2.5mm, thickness of the material should not be less than 1mm or as specified by manufacturer.
S&F in repair 160mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls with and including stack clamps complete all as specified and as directed
S&F in repair 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls with and including stack clamps complete all as specified and as directed
S&F in repair 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches with and including stack clamps complete all as specified and as directed
S & F in repair bend suitable for 160mm dia PVC (SWR) pipe complete all as specified and as directed
S & F in repair bend suitable for 110mm dia PVC (SWR) pipe complete all as specified and as directed
S & F in repairs bend suitable for 75mm dia PVC (SWR) pipe complete all as specified and as directed
M&L gunniting to RCC works in column ,beams, slabs, landing, balconies etc by removing loose concrete including plaster cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick to rusted steel reinforcement after removing/ cleaning all rust by sand/grit blasting and supply and fixing welded steel wire mesh 75mm x 75mm with 3mm dia steel wire as facies/drops and similar works etc and expoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sika. Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2.5 Kg/sqcm and applying 25mm thick layers of gunniting in cement mortar (1:2) using ordinary port land cement of 43 grade over wherever required complete all as specified. Note:- (i) After placing the additionnal reinforcement all concrete surface shall be throughly scrubbing with brushed washed with water and allow dry and plaster complete all as specified. (ii) Work to be carried out as in patches as directed by Engr-in-charge. (iii) Rate for scaffolding ,15mm thick plaster in CM 1:4 and TMT bars (where applicable) deemed to be included in quoated rate. (iv) preparation of surface and applying two coat of exterior emulsion paint with one coat of primer deemed to be included in this item.
S&F mild steel works as in wind ties for roof incl securing bolts; posts and struts in fencing incl cutting tops to shape as directed ,drilling holes,notching for wire,etc;flat iron fillets (for securing wire mesh etc) incl all necessary drilling,bolting or riveting etc and similar work conforming to Fe 410-0 or Fe 310-0 upto any height of bldg complete all as specified and directed.
M & L for prepararing old decorated steel (plain/ corrugated) surfaces by washing down and applying one coat of synthetic enamel paint complete all as directed.
M&L for preparation of new steel surfaces of any description of width or girth,not otherwise described and apply two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F in repair mild steel works as in wind ties for roof incl securing bolts; posts and struts in fencing incl cutting tops to shape as directed ,drilling holes,notching for wire,etc;flat iron fillets (for securing wire mesh etc) incl all necessary drilling,bolting or riveting etc and similar work conforming to Fe 410-0 or Fe 310-0 upto any height of bldg complete all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
1775tender.pdf
Tender Documents • 1.65 MB
Credit1775.xls
Additional Documents • 0.19 MB
BOQ_842424.xls
BOQ • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .