Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹28.4 L+₹1.5 L (5.60%)Rejected-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹30.7 L+₹3.8 L (14.1%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹32.9 L+₹6.0 L (22.4%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹34.5 L+₹7.7 L (28.5%)Rejected-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Jul 2022, 6:00 pmClosed
RAHUL MEENA IDSE EE
GE MES OFFICE KASAULI , DIST - SOLAN , HP
REPAIR,MAINT OF EXT. ELECTRIFICATION, LT PANEL LT UG CABLE, POLE,EARTHING ,CONNECTED WORKS REPAIR,RENEWAL,REPLACEMENT OF SOLAR WATER HEATER SOLAR PANEL SECURITYAND STREET LIGHT, STREET LIGHT TIMER , CERTAIN OTHER WORK MIL STN SOLAN UNDER GE KASAULI
2022_MES_530321_1
GEK-23/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
SOLAN UNDER GE KASAULI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE KASAULI
₹80,000
Yes
31 Aug 2022
11 Jun 2022
26 Jul 2022
11 Jun 2022
19 Jul 2022
25 Jun 2022
Amount
Schedule 'A' Section - I
Dismantling complete solar water heating system of capacity 1000 LPD including hot & cold water pipes and hot water tank complete. Checking thoroughly for repair ,taking out the solar energy collector panel of solar water heating system row carefully and setting aside for re-use after repairs.Removing the glass covers carefully and setting aside at safe place for re-use and carry out following repair works- (a) Dismantling the solar panel descaling of hot water pipes by using appropriate chemicals, cleaning and washing all copper tube throughly cleaning the complete panel, making the tubes scale free, and re-assembling the panel. (b) Brazing the leaking broken copper tubes & fins with copper alloy brazing rod to make the panel water tight (c) Cleaning hot and cold water tanks. (d) replacement of worn out missing nuts bolts, washers, union sockets, flanges and screws etc .After sucessfully repair of the complete system re-fixing back in existing position and testing complete all as specified and directed. (Note:-All other materials shall be measured and paid separately under respective items.)
All as item No 1.00 above but capacity 600 ltrs.
All as item No 1.00 above but capacity 500 ltrs
Supply and fixing in replacement Solar collector flat plate,cu-cu ,absorber area 2 sq.mtr,glazing-4mm with toughened glass solar energy collector panel complete of capacity 100 ltrs per day complete all as specified and directed by Eng- in -charge. ( Make - Solchrome or as per existing make)
Supply and fixing in replacement solar energy collector panel glass (Collector toughened Glass) complete of capacity 100 ltrs per day complete all as specified and directed by Eng- in -charge. ( Make - Solchrome or as per existing make)
Supply and fixing In replacement solar panel gasket made out of fine rubber to make system air tight, dust, and water proof complete all as specified and directed by Eng- in -charge. ( Make - Solchrome or as per existing make)
S & F In replacement electric backup system with thermostat of 3kw capacity complete including suitable size fixing accessories i.e. suiatble dia socket and control MCB with enclosure of suitable size etc complete all as specified and directed by Eng- in -charge.
Supply, laying, testing and commissioning of Weather proof flat twin core cable with aluminium conductor, size of cable 10 Sqmm 2 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repairs/replacement compressed glass wool 50 mm thick between solar energy collector panel copper tubes frame and aluminium body of panel including securing it on panel by means of necessary adhesives all as directed all as specified and directed by Eng- in -charge.
Supply and fixing in replacement aluminium sheet cover 1mm thick to protect glass wool on solar energy collector panel, fixing with frame of solar panel by means of screws all as directed and recommended by manufacturer.
Supply and fixing in repairs/replacement hot water tank of capacity 500 ltrs,SS-304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete.
Supply and fixing in replacement hot water tank of capacity 600 ltrs,SS-304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete.
Supply and fixing in replacement hot water tank of capacity 1000 ltrs, SS 304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete.
Supply and fixing in replacement steel water tubing 20 mm bore medium grade galvanised with all fittings for transportation of hot water from hot water tank to supply point duly insulated and insulation secured with tape and covered with aluminum sheet 1 mm thick all as recommended by the manufacturer.
Supply and fill anti freezing chemical through heat exchanger tank of solar water heating sysytem. Making the whole system water tight and testing on completion.
Supply & Fixing in replacement of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 15 mm bore pipes including taking out existing unserviceable Gate valve complete all as specified and as directed .
All as per item no - 16.00 above but 20 mm bore pipes.
All as per item no - 16.00 above but 25 mm bore pipes.
All as per item no - 16.00 above but 40 mm bore pipes.
All as per item no - 16.00 above but 50 mm bore pipes.
Supply only the following items for 100 mm GI Pipe :-
Bend 100 mm
Socket
Elbow
Nipple for 100 mm ,6" long
Tee 100 x 100 x 100 mm
MS flange for 100 mm bore pipes, 20 mm thick and 200 mm outer dia having 8 holes drilled for 15 mm dia bolts.
Supply only the following items for 80 mm GI Pipe :-
Bend 80 mm
Socket
Elbow
Nipple for 80 mm ,6" long
Tee 80x80x80 mm
MS flange for 80 mm bore pipes, 20 mm thick and 200 mm outer dia having 8 holes drilled for 15 mm dia bolts.
Supply only the following items for 50 mm GI Pipe :-
Socket
Elbow
Nipple for 50 mm ,6" long
union
Tee 50x50x50 mm
Supply only the following items for 40 mm GI Pipe :-
Socket
Elbow
Nipple for 40 mm ,4" long
union
Supply only the following items for 25 mm GI Pipe :-
Socket
Elbow
Nipple for 25 mm ,4" long
union
Tee25x25x25 mm
Supply only the following items for 20 mm GI Pipe :-
Socket
Elbow
Nipple for 20 mm ,3" long
union
Supply only the following items for 15 mm GI Pipe :-
Socket
Elbow
Nipple for 15 mm ,2" long
Tee 15x15x15 mm
Supply and fix in replacement of time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure. complete all as specified.
Dismantling/Taking out unserviceable Water Storage Tanks any type/any size/material of following sizes and removal from the site complete as directed :-
500 Ltr Capacity
1000 Ltr Capacity
750 Ltr Capacity
Supply and fixing in replacement of Rotational moulded Polyethylene Water Storage Tanks (cylinderical vertical with closed top cover including locking arrangements hoisted and fixed in position all as specified in SSR Part I 18.60 of following sizes complete all as specified.
500 Ltr Capacity
1000 Ltr Capacity
750 Ltr Capacity
Taking out unserviceable float valve of 20mm sizes and removal from the site complete as directed.
Supply and fixing in replacement of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm - 690 gms) of 20mm sizes complete all as specified.
Taking up or down 20mm bore steel water tubing pipe removing from site & S&F steel water tubing galvanised 20 mm bore medium grade in trenches/under roads/floors etc with bend , union , flange and all fittings complete all as specified and as directed.
Supply and fixing in replacement of LED Solar street light fitting 12 Watt including galvanized steel pole 5 Meter height in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed by Engr-in-Charge. (Excavation & earth work shall be measured separately)
PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of electric poles etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified.
S & F in replacement of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Dismantling of 0ld UNSV ACSR or AAC conductors, any type and size from the poles complete, all as specified and directed by Engr-in-Charge.
Supply and fixing new ACSR conductor including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc, complete, all as specified and directed by Engr-in-Charge.
Dismantling stay assembly complete.(demolition of concrete, etc. and excavation measured separately)
S&F Stay assembly complete with accessories as shown in electrical plate No-1 (loop type insulator, stay clamps, excavation and concrete measured separately) with stay rod 16mm dia, MS plate 6mm thick size 230x230mm, complete, all as specified and directed by Engr-in-Charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use within 50m.
Supplying & fixing in replacement of Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated & directed and including one primer coat, one under coat and one finishing coat of paint, fixed in replacement including taking down existing one, complete, all as specified and directed.
Dismantling insulators any type, any size complete.
Supplying & fixing in replacement of pin insulator porcelain vitreous, white, brown & green incl. One galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height 65mm dia for 1100 volts grade, complete, all as specified and directed.
Supplying & fixing in replacement of shackle type porcelain, vitreous , white, brown or green insulator including galvanised mild steel straps washers insulator bolts, washer and nuts of size 100 mm height, 115mm dia for working pressure 1100 volts, complete, all as specified and directed.
S&F Loop type insulator, vitreous porcelain white , brown, green small size with overall dimensions 65mm x 90mm clearance of hole 16mm, complete, all as specified and directed.
S&F in replacement of Galvanized stay strand, size 7/2.24 mm, incl taking down the old unserviceable stay wire, complete, all as specified and directed.
Taking down street/security/Gate light fittings LED/HPSV/CFL light fittings of any capacity or type from pole/wall after disconnection and connecting wires, carrying out to store yard for necessary repair/replacement of spares and fittings etc.,complete, all as specified and directed.
Refixing only street light fittings any type or capacity (Item obtained from Srl No.48.00 after repair) including making connections with cables and testing, complete, all as specified and directed. Note:- Cable required for replacement shall be measured and paid for separately.
Supply and fixing in replacement of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.
Supply and fixing inreplacement of Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
Supplying & fixing in replacement of street light fitting GI bracket made out of 40mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall complete, all as specified and directed.
Supplying & fixing in replacement of clamps made out of 40x6 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete, all as specified and directed.
S&F Steel water tubing, light grade, galvanised (ISI marked), 80 mm bore with all fittings, laid in trenches/ under roads or fixed to poles for passing cables for protection of cables, complete, all as specified and directed.
Taking down carefully under ground cable of any size and making good to disturbed surface as per existing complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 120 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 95 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 70 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 35 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 25 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 25 Sqmm 4 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 16 Sqmm 4 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 10 Sqmm 2 core, complete, all as specified and directed.
Streching of loose ACSR conductor including jumpering, binding,etc all as required in LT OH line, complete, all as directed. Note:- Disconnecting the existing security light or cable connection before stringing and reconnecting after stringing is included in the rates quoted.
Dismantling earth wire or copper conductor, service feeder or distributor span complete.
Supplying & fixing in replacement of GI wire as earth wire of size 4mm dia as required at site complete all specified and directed.
Supplying & fixing in replacement of connection/Junction box made out of 1.6mm thick MS sheet front openable, weather & vermin proof including painting two coats of synthetic enamel paint over a coat of red primer. Connection box shall be suitable for housing & including aluminium bus bar 25 Amps cap - 2 Nos, MCB SP 6 Amps- 01 No and having provision of cable hole in bottom for two to three cables of size 16 Sqmm 4 core armoured cable connection box shall be fitted on street light pole and fixing arrangements i.e. MS clamps etc deemed to be provided by the contractor, size of box - 200 x 150 x 100mm, complete, all as directed.
Supplying & fixing in replacement of double walled corrugated HDPE duct pipe of 63 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittinggs for cable protection complete all as specified and direcetd.
Supplying & fixing in replacement of non metallic rigid PVC conduit medium grade 20 mm dia ISI marked to be fixed on pole with all fittings including mouth pieces for passing of sub main wiring, complete, all as directed.
M&L Cable PVC insulated PVC unsheathed un-armoured copper conductor (multi stranded) of cross sectional area 2.5 sqmm 2 core all as required for connections to light fittings, complete, all as directed.
Dismantling steel poles/struts, any size complete and setting aside for re-use within 50m.
Supply and fixing in replacement of Steel tubular swaged poles complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified type 410 SP-31 9.0 mtr long duly painted with two coats of aluminium pait over a coat of red oxide primer complete, all as specified and directed.. Note- Excavation, earth work and PCC shall be measured and paid separately.
M&L for Painting of steel tubular pole 9.0 metre long, by applying two coat of aluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enameled paint (30 Cms each). Pole Nos will be written on pole by black paint in yellow circle of 150mm dia, complete, all as specified and directed. Note:- Only one coat will be applied at one time and payment at 50% of coated rate to be applied at the first time of first coat. Second coat is to be done more than 30 days after first coat.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth, for foundations, laying of pipes etc and not exceeding 10Sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in any type of soil, complete, all as specified and directed.
Returning filling in with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed.
Removing excavated material (soils) to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete, all as specified and directed.
Supply and laying Sub Class 'B' common burnt bricks, old size, designated 75, laid dry, flat with width equal to length of brick & with gaps between the adjucent bricks not exceeding 10mm as cover laid over the cable to give mechanical protection to under ground cable, complete, all as specified and directed.
Supply and lay Dry sand cushioning to under ground electric cable on layer of 8cm thick before laying the cable and second layer of 15cm thick after laying the cable, complete, all as specified in clause 19.75 of M.E.S Schedule Part-I (2009) and directed.
Earthing with Galvanised iron earth plate electrode 600mm x 600 mm & 6 mm thick burried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL, connected to GI earth lead wire 4 mm dia connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm bore medium grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No 3 of MES Schedule Part I, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sq M, watering arrangements with 20 mm bore GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete
Supply and fix in replacement of Sheet metal enclosure including fiiting on wall including and making the connection with MCCB 4 Pole 100 Amps 16 KA, 415 volts , 50 Hz ,thimble/lugs, aslo including all nuts bolts required for fixing all as specified and directed by Engineer - in - Charge.
Supply and fix in replacement of MCCB 4 pole 630 Amps 50 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 400 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 350 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 250 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 200 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 160 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 125 Amps 16 KA capacity AC 415 v complete all as specified and directed.
M&L L.T. lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 volts including dismantling and taking down old arrestors complete all as directed
M&L PVC spacer suitable for 3 wire LTOH line including taking down of old one. .
M&L PVC spacer suitable for 4 wire LTOH line including taking down of old one. .
M&L PVC spacer suitable for 5 wire LTOH line including taking down of old one. .
M&L PVC spacer suitable for 6 wire LTOH line including taking down of old one. .
Material and labour of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down of old one .
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat/cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size185 to 240 sqmm,Indoor/Outdoor type including taking down of old one.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat/cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size120 to150 sqmm,Indoor/Outdoor type including taking down of old one.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat/cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Indoor/Outdoor type including taking down of old one.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat/cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type including taking down of old one.
Pruning of tree branches and making clear LT line to the minimum distace of 1.8 mtrs all arround
For 3/4 conductors
For 5/6 conductors
Amount of credit of Rs. 64438.70 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
naina devi constructions
Ayushmat Contractors
Vijay Electricals
Rahul Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .