Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.7 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC ACCEPTED BEING LOWEST TENDERER | |
| 2 | L2₹90.7 L+₹7.0 L (8.35%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | L2 | Rejected-Finance REJECTED NOT BEING LOWEST TENDERER | |
| 3 | L3₹94.6 L+₹10.9 L (13.1%)Rejected-Finance | L3 | Rejected-Finance REJECTED NOT BEING LOWEST TENDERER | |
| 4 | L4₹95.1 L+₹11.4 L (13.7%)Rejected-Finance | L4 | Rejected-Finance REJECTED NOT BEING LOWEST TENDERER | |
| 5 | L5₹95.9 L+₹12.2 L (14.6%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance REJECTED NOT BEING LOWEST TENDERER |
Tender Value
₹98.3 L
EMD Value
₹1.7 L
Closing Date
21 Mar 2024, 6:00 pmClosed
CWE AF JORHAT
HQ CWE(AF) JORHAT
84023/E8 SPECIAL REPAIRS REPLACEMENT OF PUMP HOUSE WITH ALLIED WORKS SERVICES AT AF STN CHABUA UNDER GE AF CHABUA
2023_MES_633152_2
84023/E8
Open Tender
Civil Works
Item Rate
240 days
GE AF CHABUQ
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE AF CHABUA
₹1.7 L
Yes
23 Oct 2024
2 Mar 2024
22 Mar 2024
2 Mar 2024
21 Mar 2024
9 Mar 2024
Amount
B/R SERVICES/ WORKS
Demolition Cement Concrete (Un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed.
Demolition Brick Work, Pre-cast Concrete Block Masonry, built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., complete all as specified and as directed.
Dismantling Timber Scantling Over 40 Sq Cm in Section of Framed Work and in any Position, complete all as specified and as directed.
Taking down Chowkhat or Frame (without Taking Off Shutter from the Frame) of any description, not exc. 1.50 Sqm Each, complete all as specified and as directed.
Taking down Chowkhat or Frame (without Taking Off Shutter from the Frame) of any description, exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed.
Taking down/out Unserviceable Worn-out Wire Cloth/Netting of any description, fixed with Beads, etc., complete all as specified and as directed.
Hacking out Old Broken Glass (any thickness, Size, quality or description) from Wooden or Metal Frame or Stone, Concrete or Brick surrounds including Hacking out old Putty or Removing Beads, etc., Punching or Drilling out Old Glazing Pins/ Spring Clips, complete all as specified and as directed.
Dismantling Wrought Iron or Mild Steel Work of any description not otherwise specially provided for, complete all as specified and as directed.
Taking down Steel Rolling Shutter, Area upto 7.5 Sqm with all Accessories and Making Good Disturbed portion with Cement Concrete 1:2:4 (using 12.5mm graded aggregates) and Adjoining Disturbed portion of Surface Area Rendering with Cement Mortar 1:3, complete all as specified and as directed.
Dismantling Fencing Wire Mesh of any description, complete all as specified and as directed.
Dismantling Asbestos Cement (Corrugated, Semi-corrugated, etc,) Sheets in Roof Coverings, complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed.
Demolition Stone Slabs and Tiles of any description or thickness in Floors, Aprons, etc., laid bedded and pointed in any Mortar, complete all as specified and as directed.
Taking down Cement Plaster including Raking out Joints, Hacking for Key, Scrubbing down with Water and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed.
Excavating in Post Holes (or Similar Holes) for Fencing Post in Soft/Loose Soil, not exc. 0.50 CUM, getting out and Removing Surplus Soil to a distance not exc. 50.00 Metre and Making Good Disturbed Surfaces, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded aggregates) in Foundations, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in the Quoted Unit Rate.
M&L Cement Concrete 1:3:6 (40mm graded aggregates) in Foundations, Filling and Mass Concrete, etc., for Embedding /fixing Fencing Posts or Struts including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in the Quoted Unit Rate.
M&L Cement Concrete 1:2:4 (12.5mm graded stone aggregates) in Lintels upto 1.50 Metre Clear Span, Cills, Steps; Seismic and Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets and Railings upto 600mm in Height, Copings, Kneelers, Apex Stones, Bed Plates, Water Troughs and the Like including Weathering, Slightly Rounded or Chamfered Angles and Throating, Finishing all Exposed Faces of Concrete including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in the Quoted Unit Rate.
M&L Cement Concrete 1:3:6 (12.5mm graded stone aggregates) in Filling of Pressed Steel Frame or Chowkats, Finishing all Exposed Faces of Concrete, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Cutting Holes in Brick Walling not exc. Half Brick thick, built in Cement Mortar for inserting of Holdfasts, Lugs, etc. and Making Good to Dismantled portion with Cement Concrete 1:2:4 (20mm graded stone aggregates) or Cement Mortar 1:3 (as required) and Adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed.
S&F Pressed Steel Frame 105x60mm for Doors with One or more Rebates including necessary Fixing Lugs, Hinges, Lock Strike Plate, etc., complete all as specified and as directed.
S&F Factory Made Second Class Hardwood Plain Framed, Panelled Shutter (Two Panels) 35mm thick with Lock Rail and Panel of 9.0mm B.W.P. Commercial Ply or 12mm Veneered Particle Board with Commercial Veneering on both Faces, with Size of Rail and Stile as per IS:1003 (Part I), Kiln Seasoned and Chemically Pressure Treated and fixing to Chowkats, complete all as specified and as directed.
S&F Solid PVC Door Frame of Size 50x47mm made out of 5.0mm thick with Wood Grain Finished PVC Sheet reinforced with Mild Steel Square Tube and fixing in Opening as per Specification and Drawing of MES Schedule Part-II, complete all as specified and as directed.
S&F Factory Made Solid Panel Wood Grain Finished PVC Door Shutter 30mm thick (Style) consisting of Frame made out of Mild Steel Tubes for Top & Bottom Rails, Mild Steel Frame shall be covered with Heat Moulded Plain Color PVC ‘C’ Channel having a PVC Strip of 20mm width stuck inside with Solvent Cement for Stiles & Plain Color PVC Sheets for Top Rail, Lock Rail & Bottom Rail on Either Side & gap insert for Top Rail & Bottom Rail, Panelling of Plain Color PVC sheet to be fitted in the Mild Steel Frame, welded/ sealed to the Stiles & Rails with suitable PVC Sheet Beading & jointed together with Solvent Cement and fixing in the Frame as per Site as per Specification and Drawing of MES Schedule, complete all as specified and as directed.
M&L Anodised Aluminium Powder Coated (Thickness of Powder Coating not less than 50 micron) Ventilator with Louvers using Aluminium Sections Weighing not less than 0.55 KG PER RM, Partially Glazed Shutter 5.0mm thick x 10 Cm Wide Frosted Glass Strips including EPDM Rubber/ Neoprene Gasket, Glazing Clips as required, Frosted Glass Louvers and allied Items to facilitate Louver Action, complete all as specified and as directed. NOTE : Cost of Aluminium Bedding, Gasket, Builders Hardware’s, Glass, etc. as required deemed to be included in the Quoted Unit Rate.
S&F Aluminium anodised Barrel Tower Bolt, 150mm long, Extruded Section and Fixing to PVC Door Shutter, complete all as specified and as directed.
S&F Aluminium anodised Barrel Tower Bolt, 200mm long, Extruded Section, complete all as specified and as directed.
S&F Aluminium alloy anodized, Sliding Door Bolt 300mm Long with Hasp Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Section and fixing Bolts and Sliding Bolts of Extruded Section, complete all as specified and as directed.
S&F Stainless Steel Butt Hinge of Size 100mm (as approved) and Fixing to PVC Shutter, complete all as specified and as directed.
S&F Mild Steel Butt Hinge of Size 100mm, Medium Weight, Cold Rolled and Welded to Pressed Steel Frame, complete all as specified and as directed.
S&F Aluminium anodised Handle of Size 125mm, Cast type and Fixing to PVC Door Shutter, complete all as specified and as directed.
S&F Aluminium anodised Handle of Size 150mm, Cast type, complete all as specified and as directed.
M&L Stainless Steel Wire Netting 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed.
S&F Sheet Glass 3.0mm thick, Plain, Ordinary quality, in Square not exc. 0.50 Sqm in Each Pane and Glazing with Oil Putty/ Beading, complete all as specified and as directed.
S&F Steel Window with Side Hung Shutters including Projecting type Hinges with Steel Handle and Steel Peg Stay, complete With Glazing Bars, dovetailed or welded and necessary Arrangements to fixed with Wooden Scantling/ Supports, etc., complete all as specified and as directed.
S&F Steel Window with Side Hung Shutters including Projecting type Hinges with Steel Handle and Steel Peg Stay, complete Without Glazing Bars, dovetailed or welded and necessary Arrangements to fixed with Wooden Scantling/ Supports, etc., complete all as specified and as directed.
S&F Steel Ventilator with Top Hung Shutter including Hinges, Steel Peg Stay, Without Glazing Bars, dovetailed or welded including Guard Bars/ Grills, complete all as specified and directed.
M&L Mild Steel Framed Works such as Grills, Gratings, etc. with Ends of Bars shouldered and/or riveted or forged into Spikes, Framed Guard Bars; Barred Iron Doors, Ladders, Framed Balusters, Walkways, Railings, Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as specified and as directed.
M&L Mild Steel Bands, Straps, Supports or Stays for Rain Water, Ventilating Pipes including Bolts (if required), Heavy Hooks (Stay) for Large Gates; Hook and Pintle Hinges, Large Hasps and Staples; Chains; Hand Made Sliding Bolts; Clamps; Holdfasts (Flat Iron 25x4.0mm); Wall Ties; Hooks for Hanging Fans; Plain Angle Cleats for securing Purlins to Wood Trusses or Rafters; Knee Piece inserts; 2-way and 3-way Straps, Plate Washers and Similar Small Articles, conform to Fe-290 Gde-E-165, complete all as specified and as as directed.
M&L Rolled Mild Steel Sections in Joist, Channel, Angle, or Tee Sections in Vertical Post, fixed Independently, without Connecting Plates, etc. (cut to ordinary Lengths i.e. within 20mm of the Length indicated), conforming to Fe-410-W (Gde E-250) Quality 'A', complete all as specified and as directed.
M&L Rolled Mild Steel Sections in Main and Cross Beams, Hip & Jack Rafters, Purlins where connected to common Rafters, Running Rails and Guides for Sliding Doors, conforming to Fe-410-W (Gde E-250), Quality 'A', fixed with Angle Cleats or Other Connecting Plates, complete all as specified and as directed.
M&L Rolled Mild Steel Sections in Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails and Fastenings and Heavy Bracket Framing (Beam, Tee, Angle, Channel or Flat Sections) including Distance Pieces, Cleats, etc. conforming to Fe-410-W (Gde E-250), Quality 'A', fixed with Angle Cleats or Other Connecting Plates, complete all as specified and as directed.
M&L Compound Girders and Stanchions, Lattice Girders, Aerial Masts and the like including Caps, Bases, Splices etc., built up from Two or More Beam or Channel Sections or Angles with Plates including all Lattice Bars, Stiffeners, Gusset Plates, etc., conforming to Gde Fe-410-W (Gde E-250) Quality 'A', complete all as specified and as directed.
M&L Steel Rolling Shutters 1.0mm Laths thickness, without Ball Bearing, as specified including Top Cover, Anchoring Rod, Hasp and Staple and One Shop coat of Primer; erected in Position as indicated, Push Pull or Manual type, complete all as specified and as directed.
S&F Mild Steel Safety Lever Locks with 4 Levers for Rolling Shutters, complete all as specified and as directed.
S&F Ball Bearing for Rolling Shutters, complete all as specified and as directed.
M&L Mild Steel Works such as Posts and Struts in Fencing including cutting Tops to shape as directed, drilling holes, notching for Wire, etc.; including all necessary drilling, bolting or riveting, etc. and Similar Work, conforming to Fe-290, Gde-E-165, complete all as specified and as directed.
M&L Mild Steel Flat Iron 40x4.0mm (Fillet for securing Wire Mesh, etc.) cut to length including all necessary drilling, bolting or riveting, etc. and Similar Work, conforming to Fe-290 Gde E-165, complete all as specified and as directed.
M&L Mild Steel Screw Bolts (Machine made) 5.0mm to 10mm diameter of Neck and Length of Bolt exc. 5.0 Cm and not exc. 10 Cm with Hexagonal or Square Heads at One End and screwed the Other End, or screwed Both Ends, Each screwed End to be fitted with Washers and One Hexagonal or Square Nut, complete all as specified and as directed.
Supply only New Chain Link Fencing any Mesh and any Size of Mild Steel Galvanised Wire (as ordered), complete all as specified and as directed.
Fixing only New Chain Link Fencing (New Chain Link Fencing supplied here-in-above) including Line Wires, any mesh, size and type to any type of Standards, Rails, Straining Bolts, etc. including Provision of Mild Steel Binding Wire (annealed) not less than 0.90mm dia, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Ridges/Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (12.5mm graded stone aggregates) 25mm thick as in Levelling Course/ Sub-base, etc., complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregates) 100mm thick in Sub-base to Flooring, Levelling Course, etc., complete all as specified and as directed.
M&L Coloured Non-skid Ceramic Tiles (1st quality and as approved) 7.0-8.0mm thick (Square/ Rectangular), Area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including 15mm thick Screed Base/ Bed in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Screed Bed will deemed to be included in the Quoted Unit Rate.
M&L Coloured Glazed Ceramic Tiles 350x250x7.0mm/ 450x350x7.0mm thick (1st quality as approved) in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including 10mm thick Screed Base/ Bed in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Screed Bed will deemed to be included in the Quoted Unit Rate.
M&L Machine Cut Kota Stone Slab 16-20mm thick in Flooring, etc., laid over and including 20mm thick Screed Base/ Bed in Cement Mortar 1:6, laid and Joined with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including necessary Cutting, Rubbing and Polishing, complete all as specified and as directed. NOTE : Cost of Screed Bed will deemed to be included in the Quoted Unit Rate.
M&L Machine Cut Kota Stone Slab 16-20mm thick in Riser of Steps, Skirting, Dado and Pillars, laid over and including 15mm thick Screed Base/ Bed in Cement Mortar 1:4, laid and joined with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including necessary Cutting, Rubbing and Polishing, complete all as specified and as directed. NOTE : Cost of Screed Bed will deemed to be included in the Quoted Unit Rate.
M&L Chequered Cement Concrete Tiles 200x200x 25mm thick with Grey Cement and no Pigments, Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of Tiles over and including 15mm thick Screed Base/ Bed in Cement Mortar 1:6, complete all as specified and directed. NOTE : Cost of Screed Bed will deemed to be included in the Quoted Unit Rate.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregates) 75mm thick in Plinth Protection, etc., Laid in Alternate Panels, Finished Concrete Surfaces Even and Smooth without Using Extra Cement, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregates) 40mm thick in Floors, Pavings, etc., Finished Concrete Surface Even and Smooth Using Extra Cement, complete all as specified and as directed.
M&L Hardcore Broken Stone or Boulders, Gauge not exc. 63mm, deposited, spread and levelled in Layers not exc. 15 Cm thick, Watered and Well rammed to a True Surface, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregates) 50mm thick in Floors, Pavings, etc., Laid in Alternate Panels with and including necessary Formwork, complete all as specified and as directed. NOTE : Cost of necessary Formwork will deemed to be included in the Quoted Unit Rate.
M&L Filling Joints with Bitumastic Filler with 80/25 Bitumen and Coarse Sand Mixture. 1:3 by Weight, not exc. 8.0mm Wide, complete all as specified and as directed.
M&L Cement Concrete Work in Pavement / Hardstanding of Flexural Strength 40 Kg Per Square Centimetre in Field using 400 Kg of Cement Per Cubic Metre, complete all as specified and as directed.
M&L Forming Contraction (Dummy) Joints 65mm Deep x 10mm Wide and Filled with Sealing Compound Grade ‘A’, complete all as specified and as directed.
Finishing the Surfaces of Concrete Roads, Pavments, etc. by Brooming, complete all as specified and as directed.
M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Ceiling, Finished Plastered Surfaces Fair and Even, complete all as specified and as directed.
M&L Rendering 10mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 15mm thick on Bricks or Concrete Works consisting in 2 layers, Backing/Under layer of 10mm thick in Cement Mortar 1:4 and Float/Top layer 5.0mm thick in Cement Mortar 1:4 including Mixing WPC to Float/Top layer, finished Fair and Even, complete all as specified and as directed. NOTE : Integral Water Proofing Compound (WPC) will be Measured and Paid separately under appropriate Item.
Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed.
M&L Preparing Old Plastered Surfaces of Walls and applying One Coat of White Wash, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and as directed.
M&L Preparing Old Plastered Surfaces of Ceiling and applying One Coat of White Wash, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Two Coats of Cement Based Paint (of approved Tint) in Camouflage Pattern over a Coat of Alkali Resistant Priming Paint, complete all as specified and as directed.
M&L Preparing Old Plastered Surfaces of Walls and applying One Coat of Cement Based Paint (of approved Tint) in Camouflage Pattern, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls, Finishing Walls with Acrylic Smooth Exterior Paint of required Shade for New Work (Two or more Coats by Applying @ 1.67 LITRE PER 10 SQM over and including Approved Priming Coat of Exterior Primer applied @ 2.20 KG PER 10 SQM) in Camouflage Pattern, complete all as specified and as directed.
M&L Preparing New Wooden Surfaces of any description, exc. 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Pink Primer, complete all as specified and as directed.
M&L Preparing Old Painted Wooden Surfaces of any description, exc. 10 Cm in Width or Girth and applying One Coat of Synthetic Enamel Paint (1st quality Paint of approved Tint), complete all as specified and as directed.
M&L Preparing Steel and Iron Surfaces of any descriptions, exc. 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L Preparing Old Treated Steel and Iron Surfaces of any descriptions, exc. 10 Cm in Width or Girth and Applying One Coat of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint), complete all as specified and as directed.
S&F Galvanised Steel Tubing 15mm bore (dia), medium grade, conforming to IS-1239 with GI Fittings/ Connections as required/ ordered, fixed on Walls or laid in Floors including Taking up or down Old GI Tubing 15mm bore (dia) and Fittings/ Connections, complete all as specified and as directed.
S&F Galvanised Steel Tubing 20mm bore (dia), medium grade, conforming to IS-1239 with GI Fittings/ Connections as required/ ordered, fixed on Walls or laid in Floors including Taking up or down Old GI Tubing 20mm bore (dia) and Fittings/ Connections, complete all as specified and as directed.
S&F Bib Tap 15mm bore (dia) Cast Copper alloy, Chromium Plated, Fancy type, with Crutch or Butter-fly Handle, screwed down, screwed for Iron Pipe or for Brass Ferrule and Fixed-in-repairs, complete all as specified and as directed.
S&F Pillar Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type with Capstan Heads, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed Shanks and Fly-nuts, screwed for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed.
S&F Stop Valve 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, screwed down, high pressure, with Crutch or Butter-fly handle, screwed both Ends for Iron Pipe or for Unions and Fixed-in-repairs, complete all as specified and as directed.
S&F Angle Cock/ Stop Cock 15mm bore (dia), Cast Copper alloy, Chromium Plated with Long Shank and Cup (Concealed type), screwed down, high pressure with Capstan Head, screwed both Ends for Iron Pipes or for Unions and Fixed-in-repairs, complete all as specified and as directed.
S&F Gun Metal Globe/Gate Valve 20mm bore (dia) with Iron Wheel Head, screwed both Ends for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed.
M&L Rotational Moulded Polyethene Water Storage Tank 500 Litre Capacity, Cylindri-cal, Vertical with Closed Top, 3 layered, conform to IS:12701-1996, Hoisted and Fixed in Position all as specified in MES Schedule, Providing Water Supply Connections with and including GI Tank Nipple and Union (02 No.) including Lowering down Unservice-able Water Storage Tank 500 Litre Capacity after Disconnecting of Water Supply Connections, complete all as specified and as directed.
S&F PTMT Ball Valve 20mm bore (dia), having weight not less than 210 Gram, high pressure with Epoxy Coated Aluminium Rod and High Density Plastic Ball, screwed for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed.
M&L Vitreous China White Squatting Pan of Size 580x440mm, Orissa Pattern having Integral Foot Rests with and including PVC (SWR) ‘P’ or ‘S’ Trap, Providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) including provision of Lime Concrete Bedding and Making Good to Floor/ Disturbed Surfaces in Cement Mortar 1:3 and Fixed-in-repairs, complete all as specified and as directed.
S&F PVC Flushing Cistern 10 LITRE capacity White, Low Level, Valveless, Syphonic Action type, ISI Marked (IS:7231) with Inlet, Ball Valve, Float and Handle, a Pair of Cast Iron Brackets Erecting Stand duly Painted, including PVC Flush Pipe 32mm dia with PVC Long Bend, Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and Fixed-in-repairs, complete all as specified and as directed.
S&F Vitreous China White Wash Hand Basin 550x400mm in Size, Flat Back including Brass Chromium Plated Waste Coupling/ Fitting 32mm bore (dia) with 80mm Long screwed Shanks and Fly-nuts, Flange End, Bedded in Red Lead Cement and PVC Waste Pipe 32mm bore (dia), 900mm Long including a Pair of Cast Iron or Mild Steel Brackets Erecting Stand duly Painted, Cutting and Pinning in Ends and Fixed including Making Good Disturbed Surfaces in Cement Mortar 1:3 and Fixed-in-repairs, complete all as specified and as directed.
S&F PVC Connection Pipe 15mm in Size and 450mm in length with PTMT Nuts suitable for Connecting with Flushing Cistern, Wash Hand Basin, etc. and Fixed-in-repairs, complete all as specified and as directed.
S&F PVC Waste Pipe 32/40mm bore (dia), 1.50 Metre Long and Fixed-in-repairs, complete all as specified and as directed.
S&F Chromium Plated Overhead Shower Rose 125mm in Size having Long body, with Swival Joint including fixing to Steel Pipe and Fixed-in-repairs, complete all as specified and as directed.
S&F PTMT Grating Doom of Size 100mm having Minimum Weight 25 Gram (as approved) and Fixed-in-repairs, complete all as specified and as directed.
S&F PVC (SWR) Floor Trap having Diameter of Outlet 75mm, Plain with Grating including Jointing with Solvent Cement and Fixed-in-repairs, complete all as specified and as directed.
S&F PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, Single Socketed, in any length with Rubber Ring Joints, fixing to Walls or laid on Floors, etc. and Fixed-in-repairs, complete all as specified and as directed.
S&F PVC (SWR) Bend 75mm bore (dia), any Radius, etc. and Jointing with Solvent Cement and Fixed-in-repairs, complete all as specified and as directed.
S&F PVC (SWR) Vent Cowl 75mm bore (dia) and Jointing with Solvent Cement and Fixed-in-repairs, complete all as specified and as directed.
E/M SERVICES/ WORKS
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cables, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps not exc. 100mm and upto 1.20 Metre Width Strip along the Route of the Cable Lines, etc., with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Horizontal Boring by Passing GI Protection Pipe up to 80mm Bore (dia), Under Road/ Foot Path, not exc. 10.00 Metre in a Single Length, complete all as specified and as directed.
Disconnecting & Taking down/out Unserviceable LT Cable of any Size and any description including Bricks, GI Pipes, etc. from Trenches, Floors, Walls, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid separately under appropriate Items.
Supply, Laying & Testing UG XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 50 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc. includ-ing jointing with suitable Size Aluminium Lugs, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks, GI Pipes, etc. will be Measured and Paid separately under relevant Items.
Supply, Laying & Testing UG XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 70 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc. includ-ing jointing with suitable Size Aluminium Lugs, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks, GI Pipes, etc. will be Measured and Paid separately under relevant Items.
Supply, Laying & Testing UG XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 95 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc. includ-ing jointing with suitable Size Aluminium Lugs, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks, GI Pipes, etc. will be Measured and Paid separately under relevant Items.
Supply, Laying & Testing UG XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 185 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc. includ-ing jointing with suitable Size Aluminium Lugs, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks, GI Pipes, etc. will be Measured and Paid separately under relevant Items.
Supply, Laying & Testing UG XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 240 Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc. includ-ing jointing with suitable Size Aluminium Lugs, complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks, GI Pipes, etc. will be Measured and Paid separately under relevant Items.
M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 230mm Spread thickness (80mm in depth before laying the Cable and 150mm in depth after laying the Cable) and Consolidated (Punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Sub-class ‘B’ Bricks of Size 230x115x75mm, Kiln burnt for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
M&L Galvanised Steel Tubing 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing 50mm bore (dia), Light grade with Bend, Laid in Floors and/or Fixing to Electric Poles, Walls, etc., with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. NOTE : Cost of Flat Iron Clamps, Bolts, Nuts, Washers, etc. will deemed to be included in the Quoted Unit Rate.
M&L Galvanised Steel Tubing 80mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts, etc., complete all as specified and as directed.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for PUMP HOUSE No. 01, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame including Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 800 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 630 Amp, 4 Pole, 50 Hz, 415 Volt, 50 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 250 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 160 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu (g) MCCB 100 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for PUMP HOUSE No. 02, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame includ-ing Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 630 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 400 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 200 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 100 Amp, 4 Pole, 50 Hz, 415 Volt, 16 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for DG Set at PUMP HOUSE No. 02, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double doors both Side Openable with Hinged Doors and Locking Arrangement, made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame including Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 630 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 400 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 250 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 160 Amp, 4 Pole, 50 Hz, 415 Volt, 16 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (g) ATS Changeover Switch 400 Amp - 01 No.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for PUMP HOUSE No. 03, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame includ-ing Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 800 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 630 Amp, 4 Pole, 50 Hz, 415 Volt, 50 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 250 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 200 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu (g) MCCB 100 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu (h) ATS Changeover Switch 630 Amp - 01 No.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for PUMP HOUSE No. 09, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame includ-ing Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 400 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 320 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 200 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 100 Amp, 4 Pole, 50 Hz, 415 Volt, 16 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (g) MCCB 63 Amp, 4 Pole, 50 Hz, 415 Volt, 16 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (h) ATS Changeover Switch 160 Amp - 01 No.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for SEWAGE PLANT No. 01, 02 & 03, suitable to accommo-date under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame including Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable size (not exc. 200mm in each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 400 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification. INCOMING : (b) MCCB 320 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 100 Amp, 4 Pole, 50 Hz, 415 Volt, 16 kA Breaking Capacity - 04 No. with Thermal Magnetic Release Ics = 100% Icu (f) Star Delta Starter suitable for 15 HP Pump - 02 No. (h) Starter suitable for Submersible Pump 15 HP - 01 No.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for WSA 2x12 TR AC PLANT, suitable to accommo-date under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame including Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 800 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 630 Amp, 4 Pole, 50 Hz, 415 Volt, 50 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 250 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 160 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (g) MCCB 125 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for 102 SQN, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 2.0mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame including Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open Condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 630 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 400 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 160 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 100 Amp, 4 Pole, 50 Hz, 415 Volt, 16 kA Breaking Capacity - 04 No. with Thermal Magnetic Release Ics = 100% Icu (g) ATS Changeover Switch 250 Amp - 01 No.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for ATC, Platform mounted, Totally Enclosed, Dust and Vermin Proof, Openable from both Front and Rear Side, made out of 2.0mm thick CRCA Sheet complete including Inner Chambers/ Partitions to mount the under mentioned Electrical Accessories and built upon Mild Steel Angle Iron 50x50x6mm Frame work, having Front and Rear Hinged Doors, Lifting Lugs (2 No.), Provision for Earth Strip Connection, Bottom Detachable Gland Plates, Connecting using suitable Size of Zinc Plated and Passivated Nut, Bolts, Springs and Washers. Cabinet and All Members should be Chemically treated with Anti-Corrosive Chemicals and Apply Spray Paint with Two Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer. The Panel shall be suitable for 3 Phase, 4-Wire system, 415 Volts, 50 Hz with coloured Heat Shrinkable Sleeving, Internal Connections should be provided with Aluminium Strip of suitable Size and necessary grouting/ Foundation as required at Site, complete all as specified and as directed.
The Panel shall Comprising of the following Accessories :- BUS BAR CHAMBER : (a) Sheet Steel Bus-bar Chamber having Front Hinged Covers with a Set of - 01 Set Electrolytic Grade High Conductivity TPN Solid Aluminium Bus-bars 800 Amp rated, supported at required Intervals, Sleeved with Heat Shrinkable PVC Sleeving. The Bus-bars shall be Colour coded for easy Identification INCOMING : (b) MCCB 630 Amp, 4 Pole, 50 Hz, 415 Volt, 50 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 250 Amp, 4 Pole, 50 Hz, 415 Volt, 50 kA Breaking Capacity - 04 No. (f) MCCB 125 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. (g) MCCB 100 Amp, 4 Pole, 50 Hz, 415 Volt, 25 kA Breaking Capacity - 02 No. (h) ATS Changeover Switch 400 Amp - 02 No.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Outdoor LT Panel for SMQ AREA, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 3.15mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame including Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open Condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 800 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 630 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 250 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 03 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 160 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Indoor LT Panel for TECH FLT, Platform mounted, Totally Enclosed, Dust and Vermin Proof, Openable from both Front and Rear Side, made out of 2.0mm thick CRCA Sheet complete including Inner Chambers/ Partitions to mount the under mentioned Electrical Accessories and built upon Mild Steel Angle Iron 50x50x6mm Frame work, having Front and Rear Hinged Doors, Lifting Lugs (2 No.), Provision for Earth Strip Connection, Bottom Detachable Gland Plates, Connecting using suitable Size of Zinc Plated and Passivated Nut, Bolts, Springs and Washers. Cabinet and All Members should be Chemically treated with Anti-Corrosive Chemicals and Apply Spray Paint with Two Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer. The Panel shall suitable for 3 Phase, 4-Wire system, 415 Volts, 50 Hz with coloured Heat Shrinkable Sleeving, Internal Connections should be provided with Aluminium Strip of suitable Size and necessary grouting/ Foundation as required at Site, complete all as specified and as directed.
The Panel shall Comprising of the following Accessories :- BUS BAR CHAMBER : (a) Sheet Steel Bus-bar Chamber having Front Hinged Covers with a Set of - 01 Set Electrolytic Grade High Conductivity TPN Solid Aluminium Bus-bars 800 Amp rated, supported at required Intervals, Sleeved with Heat Shrinkable PVC Sleeving. The Bus-bars shall be Colour coded for easy Identification INCOMING : (b) MCCB 630 Amp, 4 Pole, 50 Hz, 415 Volt, 50 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 320 Amp, 4 Pole, 50 Hz, 415 Volt, 50 kA Breaking Capacity - 02 No. (f) MCCB 125 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. (g) MCCB 63 Amp, 3 Pole, 50 Hz, 415 Volt, 16 kA Breaking Capacity - 02 No.
Supply, Installation, Commissioning & Testing Factory Made (CPRI Approved/ Tested Manufacturer) Outdoor LT Panel for TECH FLT, suitable to accommodate under mentioned Accessories, Cubical Compartmental type, Double Doors both Side Openable with Hinged Doors and Locking Arrangement, Made out of 3.15mm thick CRCA Sheets, supported and fixed on Mild Steel Angle Iron 50x50x6mm Frame including Earthing Stud Labelling, Painting to all Internal and External Exposed Steel Surfaces with Powder Coating Paint (7 Tank/ Stage Process), duly fixed in ground with Cement Concrete 1:2:4 (20mm graded Stone aggregates) Foundation of suitable Size (not exc. 200mm in Each Side of Panel) with Danger Notice Plate 1.6mm thick Mild Steel Sheet, Vitreous Enamelled (White) with Letters Figures and Conventional Skull & Bones in Signal Red colour suitable for 3 Phase 4-Wire system, 500 Volts grade with necessary Wiring with PVC sheathed Stranded Aluminum Conductor of appropriate Size and Length with and including fixing Lugs Bolts, Screws, etc., complete all as specified and as directed. For Safety, Panel shall be Finger Touch Proof and it should have IP-20 Protection in Module Door Open Condition. Bus-bars shall be made of High Conductivity and High Strength Aluminum E91 grade as per IS 5082-1981 of Rectangular Cross sections better suitable for Full Load Current for Phase Bus-bars and Half/ Full Rated Current for Neutral Bus-bar or as per requirements/ ordered. The Bus-bars shall be supported on Non-breakable, Non-hygroscopic Epoxy Resin or Glass Fibre Reinforced Polymer insulated Supports. Materials and the Spacing of Bus-bars support should be same as per the Type Tested Assembly (TTA). All Bus-bars shall be provided in a Separate Chamber and all Connections shall be done by Bolting.
The Panel shall Comprising of the following Accessories :- BUS-BARS : (a) Solid Aluminium Bus-bar of rated capacity 630 Amp covered with PVC - 01 Set insulated Sleeves, Insulator, Nuts, Bolts, etc. including Connections complete. The Bus-bars shall be Colour Coded for easy Identification INCOMING : (b) MCCB 400 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 01 No. with Thermal Magnetic Release Ics = 100% Icu (c) Neon Indicator Lamp with Holder (R-Y-B) (Set of Three) - 01 Set (d) Digital VAF Meter with suitable CTs - 01 No. OUTGOING : (e) MCCB 250 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu (f) MCCB 125 Amp, 4 Pole, 50 Hz, 415 Volt, 36 kA Breaking Capacity - 02 No. with Thermal Magnetic Release Ics = 100% Icu NOTE : FOR SL No. 2.015 TO 2.038 Unserviceable LT Panels and Connected Items like Bus-bar, MCCB, ATS Changeover Switch, Star Delta Starter, Starter, etc. shall be Dismantling/ Taking down/ up and shall Removing and Deposited to MES Store by the Contractor for which Cost of the same deemed to be included in the Quoted Unit Rate.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of Size 25x4.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) ‘Light’ grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC 1:2:4 (20mm graded stone aggregates) Cover Slab of Size 450x450x50mm, Reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) ‘Medium’ grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing
DEDUCT 'TOTAL AMOUNT OF CREDIT' AGAINST 'SCHEDULE OF CREDIT' NOTE : Bidders are required to Quote the SAME AMOUNT (as per SCHEDULE OF CREDIT including NOTES therein of Tender documents) under Column 'UNIT RATE' (M) against Row No. 160.
M/S R G Construction
J D construction
M/S P R SINGH AND SONS
MAA COMMUNICATION
PURBANCHAL BUILDERS
HEMONTA DAS
Markson
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .