Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC WARD NO 13 NEW SURATGARH | SURATGARH | L1 | Accepted-AOC VALID | |
| 2 | L2₹10.4 L+₹93,879 (9.97%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹12.9 L+₹3.5 L (37.3%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹12.9 L+₹3.5 L (37.4%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹15.8 L+₹6.4 L (67.6%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
9 Nov 2021, 6:00 pmClosed
GE (AF) SURATGARH
GE (AF) SURATGARH
REPAIR REPLACEMENT OF MCBs DBs GEYSERS ALONGWITH ALLIED EM WORKS AT AF STN SURATGARH
2021_MES_481207_1
8910/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹30,000
Yes
2 Dec 2021
12 Oct 2021
11 Nov 2021
12 Oct 2021
9 Nov 2021
26 Oct 2021
Amount
BOQ (REPAIR / REPLACEMENT OF MCBs, DBs, GEYSERS ALONGWITH ALLIED E/M WORKS AT AF STN SURATGARH )
Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth in soft/loose soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches, complete all as specificed and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick in soil, complete all as specificed and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point , complete all as specificed and directed by Engineer-in-Charge.
M&L for sand cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth (punned down to 10 cm depth after laying and stretching of cable), complete all as specificed and directed by Engineer-in-Charge. Note: Punned thickness (over all 18 cm) shall be measured & paid.
M&L for brick of common burnt clay, sub class 'B' old size bricks laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other, complete all as specified and directed by Engineer-in-Charge.
S&F galvanised iron steel tubes, ISI marked light grade of size 40mm bore for cable protection along the poles under road under drains including taking down of old unserviceble pipe, complete all as specified and directed by Engineer-in-Charge.
Boring holes horizontally under road without damaging the surface of road upto one metre below the road surface with the help of GI tubing for passing of UG cable, complete all as directed by Engineer-in-Charge. Note:- GI Pipe shall be measured and paid separately.
Taking out old unserviceable LT cable from trenches /Wall/ floor etc of size 6 Sqmm to 16 Sqmm 2/3.5/4 core, complete all as specified and directed by Engineer-in-Charge.
S&F XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 16 Sqmm 4 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 mm dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including replacment of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
S&F Sub-main wiring (concealed ) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 2.5 sq mm copper earth continuity wire, accessories and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. NOTES :- (a) Two runs of 4 sqmm cable one run of 2.5 sqmm earth wire and one run of PVC conduit 25 mm shall be measured as one length. (b) Cable required for connection to DBs shall be deemed to be included and shall not be measured separately. (c) Earth wire shall run inside the conduit. (d) Extra length of cable required for connection to MCBs shall demed to be included.
S&F Sub-main wiring (concealed ) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. NOTES :- (a) Two runs of 6 sqmm cable one run of 4 sqmm earth wire and one run of PVC conduit 25 mm shall be measured as one length. (b) Cable required for connection to DBs shall be deemed to be included and shall not be measured separately. (c) Earth wire shall run inside the conduit. (d) Extra length of cable required for connection to MCBs shall demed to be included.
M&L for cutting holes in brick wall to passes the GI pipe 15/20 mm dia and making good distrubed portion with cement mortar 1:3 or cement concrete 1:2:4 type B-1 using 20 mm graded stone aggrigate as required complete all as specified and directed by the Engineer in Charge.
S&F sheet metal enclosures for vertical TPN DB, 4 way factory made IP 43 protection & IK09 metal, double glazed door with 200 amps rated busbar, 415 volts including provision for mounting MCCB upto 125 Amp rating, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosures for SPN DB's with metal double glazed door for incorporating MCBs, IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosures for SPN DB's with metal double glazed door for incorporating MCBs, IP-43 , 4 way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 4 pole 63 Amps with breaking capacity 16 kA, 415 Volts, 50 Hz with thermal setting 80 to 100% including making all incoming/ outgoing connections, complete all as specified and directed by Engineer in Charge.
S&F MCCB 4 pole 100 Amps with breaking capacity 16 kA, 415 Volts, 50 Hz with thermal setting 80 to 100% including making all incoming/ outgoing connections, complete all as specified and directed by Engineer in Charge.
S&F MCCB 4 pole 125 Amps with breaking capacity 16 kA, 415 Volts, 50 Hz with thermal setting 80 to 100% including making all incoming/ outgoing connections, complete all as specified and directed by Engineer in Charge.
S&F MCB SPN 5 to 40 amps 'C' series, breaking capacity 10 kA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc, complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 5 to 40 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc, complete all as specified and directed by Engineer-in-Charge.
Taking down carefully geyser of any capacity of any make any type after removing electric and water connections from existing system for carrying out repairs and re-fixing the same after carrying out necessary repairs to original place complete all as directed by Engineer-in-charge. Note:- Repairs will be measured and paid seprately in respective items of BOQ.
M&L for painting of geyser of any make/shape/capacity with two coats of white synthetic super enameled paint after preparation of surface including marking of MES No by black enameled paint, complete all as specified and directed by Engineer-in-Charge.
S&F Hot & Cold connection pipe, 15 mm dia, 45cm long with chromium plated adopter and washer at both ends including taking out old unserviceable PVC / CP connection, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of heating element spiral / circular type of capacity 2 kW, ISI marked including rubber washer of geyser 50 Litre capacity geyser, complete all as specified and directed by Engineer-in-Charge . Make : ISI Marked as approved by Engineer-in-charge. Note:- Heating element shall be providing as per existing geyser.
S&F in replacement of heating element spiral / circular type of capacity 1.5 kW, ISI marked including rubber washer of geyser 25 Litre capacity geyser, complete all as specified and directed by Engineer-in-Charge . Make : ISI Marked as approved by Engineer-in-charge. Note:- Heating element shall be providing as per existing geyser.
S&F in replacement of thermostat swtich, ISI marked suitable for 25/50 litre capacity geyser ,complete all as specified and directed by Engineer-in-Charge.
S&F bib taps fancy type chromium plated, 15 mm cast copper alloy with crutch handle or butter fly handle screwed down , screwed for iron pipe and fixed as in repair, complete all as specified and directed by the Engineer in Charge.
S&F stop valve 15 mm dia cast copper alloy fancy type chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair , complete all as specified and directed by Engineer-in-Charge.
Cutting existing 15/20 mm steel tubing for alteration and addition (each cut measured ) including screwing existing steel tubing for alteration and addition or lengthening screw on pipe to form connector , complete all as specified and directed by Engineer-in-Charge.
S&F PVC insulated copper (flexible) conductor of size 2.5 Sqmm 3 core and connected to geyser including taking down old unserviceable cable of any size complete all as directed by Engineer-in-charge.
S&F apparatus plate bottom cover in two halves made out of GI sheet dully painted with two coats of synthetic enemal paint white in colour fixed with nut, bolts, clamps, washer etc of geyser of any capacity, fixed in repair, complete all as directed by Engineer-in-charge.
Welding with new brass studs for holding of heating element with replacement of suitable element holding clamps - 3 Nos, complete all as directed by Engineer-in-charge.
M&L for indicator lamp round/flat type of size & shape as per existing suitable for 25/50 litre capacity geyser working on 230 Volts AC Supply including necessary connections etc, fixed as in repair, complete all as directed by Engineer-in-charge.
Detecting the leakage from geyser of any capacity and arresting the same by brazing / soldering complete all as directed by Engineer-in-charge.
S&F Anchor fastning of suitable size for fixing of geyser of any capacity, complete all as specified and directed.
S&F sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SPN 10 Amp 240 Volts, complete all as specified and directed by Engineer-in-Charge.
S&F plug top 20 / 32 Amp suitable for any type of geyser connection, complete all as specified and directed by Engineer-in-Charge.
S&F NRV of 15mm dia, complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, fixed as in repair, complete all as specified and directed by the Engineer in Charge.
S&F water heater outer shell (cover) of capacity 25 liter made out of MS sheet as per existing make, including taking out old unserviceable outer cover, complete all as specified and directed by Engineer-in-Charge.
S&F water heater outer shell (cover) of capacity 50 liter made out of MS sheet as per existing make, including taking out old unserviceable outer cover, complete all as directed by Engineer-in-Charge.
S&F water heater inner tank of capacity 25 ltr made out of copper suitable to with stand water pressure upto 8 bar with fittings and fixed including taking out old unserviceable inner tank, complete all as specified and directed by Engineer-in-Charge.
S&F water heater inner tank of capacity 50 ltr made out of copper suitable to with stand water pressure upto 8 bar with fittings and fixed including taking out old unserviceable inner tank, complete all as specified and directed by Engineer-in-Charge.
Over hauling & servicing of solar water heater 500/300 LPD capacity and rectifying any minor defects through authorised agency, complete all as directed by Engineer-in-charge.
S&F heating element of capacity 3/5 kW ISI marked including rubber washer for solar water geyser and taking out old unsecrivicable element., complete all as specified and directed by Engineer-in-Charge.
S&F solar panel glass suitable for 200/300 ltrs capacity solar water heater with gasket, fixed as in repair, complete all as directed by Engineer-in-Charge.
Supply & fixing single phase electronic meter digital type 230V,50Hz, 5-30A, complete all as specified and directed by Engr-in-Charge.
Taking out all connections of UPS upto 10 KVA and shifted to workshop for repairing transformer, relay, diodes as well as display with all connecting terminals and making UPS in condition and fix it at same place, complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of battery bank cousisting of maintenance free battery 90 AH 12 V - 08 Nos including connecting cooper battery cable along with terminals with suitable battery rack for 8 batteries made of iron alongwith all necessary connections all as specified and directed by Engr-in- Charge. Make:- Luminous ILST-12042/ Exide /Armour.
Replacement of apparatus plate with nut, bolts, clamps,washer, etc. of geyser suitable for Recold/Ditz make or any other make and any capacity including PRV & NRV system, complete all as specified and directed.
S&F vent pipe using medium grade GI tubing 20 mm dia fixed to wall/ceiling upto level not less than 15 cm from OH tank top level including neceessary fittings, fixtures, clamps, except Tee, complete all as specified and directed.
S&F XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 6 Sqmm 2 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed by Engineer-in-Charge.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 16 of tender documents.
MAJOR REFREGERATION AND ELECTRICALS
m/s krishna builders
SHARMA CONSTRUCATION COMPANY
MISHRA CONSTRUCTION COMPANY
DASHMESH ENTERPRISES
B.K. ROY & SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .