| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | ₹14.5 L | L1 | Accepted-AOC Quoted lowest and reasonable |
| 2 | L2₹15.4 LRejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 UDYAM AN 01 0000153 35ACZPJ3600Q1ZZ R M MII STATUS AS VERIFIED | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹15.4 L | L2 | Rejected-Finance Quoted high rates |
| 3 | L3₹17 LRejected-Finance | ₹17 L | L3 | Rejected-Finance Quoted high rates |
| 4 | L4₹17.2 LRejected-Finance NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹17.2 L | L4 | Rejected-Finance Quoted high rates |
| 5 | Rejected-Technical MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND PIN 744301 | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | - | - | Rejected-Technical ESIC Registration not submitted by the firm and Not enlisted in appropriate category i.e c (i) |
| Sl No | Description | Qty | Unit | Tropical Refrigeration L2 | M/s Karbhagam Sales Agency L3 | Everest Cooling Works L1 | RK TRADERS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for repair of LT Panel of AC Plant, floor mounted, rectangular type, by checking of MCCBs, relays, meters, busbar joints, busbar & circuit spouts etc with and including decarbonising/ cleaning of panel by applying 'Becktrol red solution' to the surface and applying of monoplast compound at the busbar joits after tightening of joints and re asembling including repair of PCC works, replacing of burnt out cable end treminals and jointing of earth connection complete all as specified and directed.
Note :- (i) MCCBs, contacts, relays, meters and timers will be paid and measured separately under the relevant items.
(ii) An inventory has to be prepared for defective parts and signed by Engineer-in-charge and contrctor while checking the worn out/ defective parts. | 2 | Each Job | 6,000 ₹12,000 | 8,000 ₹16,000 | 5,900 ₹11,800 | 7,500 ₹15,000 |
| 2.00S&F in repair including connecting and testing of MCCB 16KA, 3 pole, 50Hz, 415V AC, Ics = 100% Icu, thermal magnetic release with thermal adjustable – 0.8 to 1In, magnetic Adjustable – 5 to 10In, in existing panel and connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary) complete all as specified and directed of following capacities:- | |||||||
| 2.10 | 63 Amp | 1 | Each | 3,200 ₹3,200 | 4,500 ₹4,500 | 3,100 ₹3,100 | 4,000 ₹4,000 |
| 2.20 | 100 Amp | 1 | Each | 3,300 ₹3,300 | 4,500 ₹4,500 | 3,200 ₹3,200 | 4,000 ₹4,000 |
| 3.00S&F in repair 3 pole power contactor of following capacity (AC1 rating), heavy duty, 415 Volt AC, with auxiliary contactors of (2No+2NC) with coil voltage complete all as specified and directed :- | |||||||
| 3.10 | ML-3 type, 45 Amp. | 2 | Each | 11,000 ₹22,000 | 13,500 ₹27,000 | 10,000 ₹20,000 | 12,500 ₹25,000 |
| 3.20 | ML- 1.5 type, 25 Amps | 2 | Each | 6,000 ₹12,000 | 7,500 ₹15,000 | 5,000 ₹10,000 | 6,500 ₹13,000 |
| 4.00S&F in repair overload relay, direct mounting type suitable for ML series contactor and connecting to contactor with all connecting accessories including testing complete all as specified and directed of following capacities:- | |||||||
| 4.10 | 13 Amp to 21 Amp. | 1 | Each | 5,400 ₹5,400 | 6,500 ₹6,500 | 5,200 ₹5,200 | 6,000 ₹6,000 |
| 4.20 | 20 Amp to 32 Amp. | 1 | Each | 6,200 ₹6,200 | 8,000 ₹8,000 | 6,100 ₹6,100 | 7,500 ₹7,500 |
Tender Value
₹16.0 L
EMD Value
₹32,000
Closing Date
19 Jan 2026, 6:00 pmClosed
Col Alex Antony, Commander Works Engineer
Commander Works Engineer, Military Engineer Services, Minniebay, Junglighat PO, Sri Vijaya Puram- 744 103
81232/E8 REPAIR AND MAINT OF PACKAGE TYPE AC PLANT AND CONNECTED WORKS UNDER GE HADDO SRI VIJAYA PURAM.
2025_MES_746628_1
81232/E8
Open Tender
Electrical and Maintenance Works
180 days
GE Haddo
Class E category c i
8 documents required · 8 mandatory
₹500
GE Haddo
₹32,000
Yes
16 Mar 2026
30 Dec 2025
26 Jan 2026
30 Dec 2025
19 Jan 2026
14 Jan 2026
M&L for repair of LT Panel of AC Plant, floor mounted, rectangular type, by checking of MCCBs, relays, meters, busbar joints, busbar & circuit spouts etc with and including decarbonising/ cleaning of panel by applying 'Becktrol red solution' to the surface and applying of monoplast compound at the busbar joits after tightening of joints and re asembling including repair of PCC works, replacing of burnt out cable end treminals and jointing of earth connection complete all as specified and directed. Note :- (i) MCCBs, contacts, relays, meters and timers will be paid and measured separately under the relevant items. (ii) An inventory has to be prepared for defective parts and signed by Engineer-in-charge and contrctor while checking the worn out/ defective parts.
S&F in repair including connecting and testing of MCCB 16KA, 3 pole, 50Hz, 415V AC, Ics = 100% Icu, thermal magnetic release with thermal adjustable – 0.8 to 1In, magnetic Adjustable – 5 to 10In, in existing panel and connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary) complete all as specified and directed of following capacities:-
S&F in repair 3 pole power contactor of following capacity (AC1 rating), heavy duty, 415 Volt AC, with auxiliary contactors of (2No+2NC) with coil voltage complete all as specified and directed :-
ML-3 type, 45 Amp.
ML- 1.5 type, 25 Amps
S&F in repair overload relay, direct mounting type suitable for ML series contactor and connecting to contactor with all connecting accessories including testing complete all as specified and directed of following capacities:-
13 Amp to 21 Amp.
20 Amp to 32 Amp.
S&F in repair electronic timer, type ST 100, suitable for 240/ 360/ 415V complete all as specified and directed of following capacities:-
S&F in repair single phase preventer as per existing make and model complete all as specified and directed.
S&F in repair front door of 2mm thick CRCA sheet of Panel as per existing make and model complete all as specified and directed.
S&F in repair complete control wiring as per existing make and model complete all as specified and directed.
Supply only following spare/ parts for repair compressor complete all as specified and directed:-
Compressor oil, N-68, in sealed pack.
Refrigerant gas R-404 in manufacturer sealed cylinder.
Wedge (V) Belts B-72
Wedge (V) Belts SPA - 1700
M&L for servicing of indoor unit of air cooled air conditioning plant package type of following capacity by opening front grill, bottom grill cleaning filters, by spraying water jet, removing dust/ dirt from package unit all over, checking electric connection, checking any leakage by applying soap solution on joint & liquid/ vapour lines properly checking functionality of all spares & replacing the same under relevent item of schedule & put the air conditioner into operation complete all as specified and directed :- Note : (i) Spare parts will be measured and paid separately. (ii) Sliding the filter out and washing it with water and drying in the shade, reinstalling the same.
Capacity 3x 11 TR
Description same all as per item No 13 above, but outdoor unit of AC plant of following capacities:- Note : Inspection of vibration insulation rubber for wear and fightening the mounting lugs.
Capacity 3x 11 TR
Capacity 5.5 TR
S&F in repairs of following spares/ parts suitable for AC Plant (Make: Blue Box) of capacity 11 TR including commissioning and teting complete all as specified and directed :-
Wedge (V) Belts A -32
Refrigerant gas R- 22 in manufacturer sealed cylinder.
Thermostatic Expansion valve.
Fan motor for outdoor unit .
Logical control board .
Nylon filters of size 21" x 18" inches and 10 micrones built with GI casing frame box type.
Thermostatic sensors.
Filter drier.
Temrature control.
HP/LP cut off switch MP-15 suitable for working on R-22 gas with flare nut.
S&F in repair of suction & discharge valve of compressor 5.5TR of capacity (Make: BOCK Compressor) by means of replacing the teflon washer sheet, suction & discharge valve ring, spring, 'O' rings, gaskets etc complete and testing for proper holding of valve, leak testing etc complete all as specified and directed. Note: The unit rate quoted shall deemed to be include the cost of suction & discharge valve and shall be considered as one job.
M&L for servicing/ overhauling including repairs and maintenance of Cooling tower of capacity 36 TR, water cooled chiller type Central AC plant by dismanlting/ taking down the CT fan motor of flange mounted extended type shaft upto 5 HP, 3 phase, 415volts, 50Hz along with fan assembly, and including cleaning & removal of scales, inspection, cleaning and replacement of PVC fills, PVC eliminator, FRP louvers, motor cover, splash cups etc complete including renewal of all corroded bolts & nuts, terminal block, and re-assembling, fixing in position, fixing of fan blade, and alignment of the fan blade for the suitable air throw of the cooling tower, painting with two coats of synthetic enamel paint over a coat of anticorrosive paint after preparation of surfaces, testing & commissioning the cooling tower motor complete all as specified and directed. Note:- (i) Spares/ parts will be measured and paid separately under relevant items. (ii) An inventory has to be prepared for defective parts and signed by Engineer-in-charge and contrctor while checking the worn out parts. (iii) The rates inclusive for all T&P, chemicals required for cleaning, FRP compound, nut bolts etc complete for keeping the cooling tower in operational condition.
M&L for Servicing of Air Handling Units (AHU) by removing the filter, vacuumising the filter, washing the filter and re-installing the cleaned filter, brush the cooling coil and spray the foam coil cleaner including rinsing of coil, alignment of shaft & motor, servicing of chilled water line strainer for the AHUs, tightening of terminals of motor, replacement of V belts, replacement of bearings complete all as specified and directed of following capacity of AHU plant :- Note: The unit rate quoted shall deemed to include the cost of blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,greasing of blower motor, replacement of unserviceable bearings, V belts, water drain lines, renewal of rusted sheet metal screws and testing & commissioning the unit.
Capacity 7000 CFM.
S&F in repair of the following spares/ parts suitable for AC plants of capacity 5.5/ 11/ 18/ 36TR AC plant (Make- Carrier/ Bluestar/ Voltas) including complete all as specified and directed :-
Solenoid pilot control valve coil assembly, 11 watt, 230 volt AC, type 6, size 2, as per OEM.
Water pressure cut out, 1 PSI or as per existing/ site requirement complete all as specified and directed.
LP/OP pressure gauge, dial size 4" dia of rating 30 to 150 PSI suitable for working on R-404 gas complete with flare nut.
High pressure gauge, dial size 4" dia of rating 0 to 300kg/cm2 suitable for working on R-404 gas complete with flare nut.
Oil pressure cut off switch, MP - 55 suitable for working on R-404 gas complete with flare nut.
Water pressure gauge dial size 4" dia, 0-7 PSI rating.
Expansion valve including brazing, welding work.
Suction & discharge hydrant copper pipe line 32 mm dia and 1 mm thick for Compressor and condensor including replacing the suction & discharge valve ring, adaptor, 'O' rings, junction clip etc along with rubber insulation and necessary brazing.
S&F in repairs Direct on line (DOL) for motor starter rating AC-3 duty, 415 volt, 50 Hz, 3 phase supply suitable for 7.5 HP motor complete all as specified and directed.
S&F in repair for cast iron butterfly valve of size 65 mm dia flanged of class PN 1.6 conforming to IS - 780 complete with iron wheel head, stainless steel spindle and check nut, including jointing material such as rubber insertion nut bolts washers etc complete all as specified and directed.
S&F in repairs for two core stranded copper conductor armoured cable 1100 V grade with and including rigid PVC conduit of 20mm dia and copper end terminals (ISI marked) complete all specials all as directed of following size :-
M&L for preparation of old steel surfaces and applying one coat of synthetic enamel paint in position to all surfaces for for following including base frames at pump houses of centrifugal / Monobloc pumps with and including writing the details complete all as specified and directed :-
Centrifugal pump sets.
Monoblock pump sets.
Compressor unit of 18 TR
Condensor unit of 18 TR
Main LT Panel board
Compressor LT Panel board
M&L for dismantling, carefully shifting and depositing of packages type AC plant of capacity 3x11TR to AGE E/M store yard from CG RHQ AC Plant by using of crane and vehcle without damage and comprising the followings complete all as specified and directed:- (a) Out door unit of 5.5TR - 06 Nos (b) Indoor Unit - 03 nos (c) LT Panel complete - 01 No (d) GI sheet ducting for supply and return of air, grills, defuse & return air boxing etc - 01 Set (e) Pipe lines - 03 Sets
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
Tender81232.pdf
Tender Documents • 1.22 MB
BOQ_836054.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid