Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹5.8 L+₹1,554.20 (0.27%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹6.6 L+₹81,744.20 (14.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹6.7 L+₹91,236.20 (15.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
19 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (R)
AGE (I) CIF (R) C/O 56 APO
PROVISION OF ADDITION/ ALTRATION TO BLDG NO.T-166 (COOK HOUSE) AT HQ CIF (R) UNDER AGE (I) CIF (R).
2023_MES_609834_1
AGE(I)/R-37/2023-24
Open Tender
Civil Works
Item Rate
120 days
AGE (I) CIF(R)
Class E and above and category a (i)
8 documents required · 8 mandatory
₹500
AGE (I) CIF (R)
₹19,400
Yes
26 Sept 2023
20 Jul 2023
28 Aug 2023
20 Jul 2023
19 Aug 2023
4 Aug 2023
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm each and n. exc. 4.00 sqm each and removing from site, complete all as specified and directed.
Demolition of brick work / stone masonry built in cement mortar or cement lime mortar including all quoins ,arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation filling and mass concreate, complete all as specified and directed.
Pressed steel frames factory made for doors out of 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, hinges, lock strike plate, hinges etc complete, size of frame 125x60mm complete all as specified and directed
Supply and fix Factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 30 mm thick complete, all as specified .
Supply and fix 30 mm thick, second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge.
S & F Floor door stopper of aluminium alloy body and tongue , anodised , with hard drawn steel spring , fixed in floor , over all length of cover plate 140 mm , complete all as specified and directed.
S & F 125 mm extruded aluminium alloy handles, fabricated type, anodisedand, complete all as specified and directed.
S & F 150 mm aluminium anodised barrel tower bolt of extruded section and fixed,complete all as specified and directed.
S&F 300 mm mild steel oridinary rat tail rod pattern springs including roller and roller plates, complete all as specified and directed.
S&F mild steel sliding door bolts 300mm long, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples including fixing with beads, nut bolts, welding, etc complete all as specified.
Hacking out old broken glass (any thickness,size,quality or description) from wooden frames or stone concrete or brick surrounds,glazed with putty or fixed with beads, complete all as specified.
S & F 3.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane, complete all as specified.
Dismantling of wall tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L Glazed ceramic coloured tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4, all as specified and directed.
Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. in cement mortar complete all as specified.
M&L for 25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
Screed bed or bedding 15 mm thick layer in CM 1:4 for laying floor finishes all as specified.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by engr-in-charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and smooth complete all as specified and directed by engr-in-charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls complete all as specified and directed by Engineer-in-charge.
M&L for 10 mm thick rendering on fair faces of brick work in cement mortar 1:6 and finished even and smooth without using extra cement, complete all as specified.
Preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper, white or tinted over & including a coat of primer complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness in roof covering and removing from site of work complete all as specified and directed.
S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
S&F Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M&L for mild steel rolled work as in roof trusses ( framed) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing( Beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc. , conforming to grade Fe 410-S, complete all as specified and directed.
M&L 75mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in Sub base complete all as specified and directed.
Taking up or down GI pipes 15mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, S&F GI tube 15mm bore medium grade galvanised ISI marked with all fittings complete on walls complete all as specified and directed.
S&F steel window/ ventilator made of MS tubular frame factory made double shutter of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter glazed and gauged with glazing bars 12x3mm flat iron including projection type hinges with steel handles and steel peg stay dovetailed or welded including necessary locking arranment complete,incl one coat red oxide primer complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/Fan socket or power) with complete fittings such as switch, sockets Ceiling rose pendent holders regulators etc. Removing old/UNSV material from site and making good the old disturbed surface.
M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor cable PVC insulated unsheathed cable 1100 volt grade enclosed and including PVC casing and capping with fittings and accessories fixed to walls/ceiling by means of PVC rowl plugs fasteners with cadmium plated screws all as per IS including hard wood board PVC board and 3mm thick laminated sheet top covers including 1.5 Sqmm copper PVC insulated unsheathed continuous earth wire and connected to common earth dolly for the following:-
One light/fan point controlled by one switch 5 Amp.
One bell point 5 Amp controlled by one bell push on independent board.
One socket outlet 5Amp controlled by one switch on same board.
All as per item No 35 here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
Supply and Fixing in replacement switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed
Supply and Fixing in rteplacement socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket outlet 6 pin 6/16 Amps multi purpose flush type 230 volts AC complete all as specified and as directed
Supply and fixing in replacement ceiling rose 65X50 mm two to three terminals complete all as specified.
Supply and Fixing in replacement fan regulator, electronic step type heavy duty 230 volts, complete all as specified and as directed.
S&F in replecement of unseviceable Ultra slim LED light to new 36W LED recess mounted bakalite panel 2 x 2 luminaire suitable for surface/grid ceiling for low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector complete all as specified and as directed. Make Havells Cat part No.STRATO2X2PLR36WLED830MOD or equivalent make as specified in list of make here-in-after.
Supply and fixing in replacement of Endura Linear NEO wall mounted LED Batten 20 Watt LED, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosure MCB distribution board SPN 8 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
S & F MCB single pole 6 to 30 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCB SPN 63 Amps, 10 KA, 230 volts 'C' series, complete all as specified and directed.
S & F XLPE cable, insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 10 Sqmm 2.0 core, complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
M&L GI Earth wire size 04 mm as earth continuty conductor.
S & F electric Mosquito/insect killer (Fly swatter), plastic body indoor type inbuilt 2 tube light of 24" chemical free 220-240V AC, 36W complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed.
Supply and fix of exhaust fan made of steel body AC single Phase, 230V, 50 Hz,RPM 1400, Copper winding of sweep 300mm with. Blades, frame and louvers complete all as specified.
Supply and fix of exhaust fan made of steel body AC single Phase, 230V, 50 Hz,RPM 1400, Copper winding of sweep 450mm with. Blades, frame and louvers complete all as specified.
M&L of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as on length.
Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed.
Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Steel tubing galvanized (medium grade) 50 mm bore conforming to IS-1239 for passing cable under road/floor or fixing to poles for protection of underground cable complete with Flat iron 50x6mm clamps made to shape and 12mm dia bolts, nuts and washers for fixing where required. NOTE :- Excavation and earth work shall be measured and paid separatly
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 16,199.00 during AOC Note:- Tenderers shall not quote for this Schedule
M/S KALSI ENGINEERS AND CONTRACTORS
SUBASH CHANDER
M/S RAHUL GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .