Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST | |
| 2 | L2₹21.0 L+₹2.0 L (10.6%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹22.1 L+₹3.2 L (16.8%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹22.5 L+₹3.6 L (18.9%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹26.3 L+₹7.4 L (38.8%)Rejected-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Sept 2022, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GARRISON ENGINEER SOUTH UDHAMPUR C/O 56 APO
GE S U 29 2022 23 REPAIR MAINTENANCE OF CERTAIN PARTS OF GEYSERS REWIRING OF OTM MD ACCN REPAIR AND MAINT OF BLDG EARTHING AT OFFRS JCOS AND OR MD ACCN AT CERTAIN LOCATIONS UNDER AGE EM OF GE SOUTH UDHAMPUR
2022_MES_544758_1
GE/S(U)-29/2022-23
Open Tender
Civil Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT documents
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹70,000
2 Nov 2022
11 Aug 2022
9 Sept 2022
11 Aug 2022
8 Sept 2022
25 Aug 2022
11 Aug 2022 - 20 Aug 2022
Amount
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
Point wiring for one light /fan/ Bell point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade in and including not less than 2.00 mm thick and 20 mm dia Non metallic Rigid PVC surface/Concealed Conduit ( ISI marked ) and 1.25 mm thick mild steel terminal boxes (Modular Type) concealed in wallsfor fixing of modular switches/sockets/ regulator etc along with PVC insulated and unsheathed FRLS 1.5sqmm multi stranded copper conductor cable (green color) as earth lead, & connected to common earth and earthdolly, making good the disturbed surface to match with the existing specification complete all as specified and as directed.
All as per Item No.2 but for one light point controlled by two nos two way modular switches on independent Board with 1.5sqmm size of copper cable complete all as specified and as directed.
All as per Item No. 2 but for 3 pin 5 Amp Socket outlets point controlled by one modular switch 6A piano type on Same board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.2 but for 3 pin 5 Amp Socket outlets point controlled by one modular switch 6A piano Type on Independent board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Srl item No 2 but for 3 Pin 15 Amps socket outlet independent with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 2 but for 3 Pin 15 Amps socket outlet independent with cable 4.0 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F Switch 10 Amps single pole one way (Modular Type) with outer strip complete all as specified and as directed. (Make - Havells Rio/Legrand/Indoasian Elvira)
S&F Switch 20 Amps single pole one way (Modular Type) with outer strip complete all as specified and as directed. Make - Havells Rio/Legrand/Indoasian Elvira)
S&F Socket 5 Pin 10 Amps flush type (Modular Type) complete all as specified and as directed. Make - Havells Rio/Legrand/Indoasian Elvira)
S&F Socket combined 2-in-1, 5 Pin 10 & 20 Amps flush type (Modular Type) with outer strip complete all as specified and as directed. Make - Havells Rio/Legrand/Indoasian Elvira)
S&F in repairs Two way switch modular type, 1 module, 6 Amps complete all as specified and as directed. Make - Havells Rio/Legrand/Indoasian Elvira)
S&F in repairs Bell push with indicator modular type, 1 module,6A, complete all as specified and as directed. Make - Havells Rio/Legrand/Indoasian Elvira)
S&F in repairs Fan regulator modular type, 2 module, step type,100 watts complete all as specified and as directed. Make - Havells Rio/Legrand/Indoasian Elvira)
Point wiring for one light /fan/ Bell point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade in and including not less than 2.00 mm thick and 20 mm dia Non metallic Rigid PVC surface/Concealed Conduit ( ISI marked ) and 1.5 mm thick mild steel terminal boxes concealed on walls, painting the same inside and out side with one coat of black bitumen paint with 3mm thick hylam brand bakelite sheet cover for fixing of piano switches/sockets/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable (green color) as earth lead, & connected to common earth and earthdolly, making good the disturbed surface to match with the existing specification complete all as specified and as directed.
All as per Item No.15 above but for one light point control by two nos two way switches on independent Board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.15 above but for 3 pin 5 Amp Socket outlets point controlled by one switch 5A piano type on Same board with 1.5sqmm size of copper cable complete all as specified and as directed.
All as per Item No.15 above but for 3 pin 5 Amp Socket outlets point controlled by one switch 5A piano Type on Independent board with 1.5sqmm size of copper cable complete all as specified and as directed.
All as per Srl item No 15 above but for 3 Pin 15 Amps socket outlet independent with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 15 above but for 3 Pin 15 Amps socket outlet independent with cable 4.0 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F in repairs Switch piano flush type SP, one way 5 Amps complete all as specified and as directed.
S&F in repairs Switch - socket combination 2-in-1, 5 Amps, flush type complete all as specified and as directed.
S&F in repairs Switch - socket combination 5A/16 Amps, 5 in 1 complete all as specified and as directed.
S&F in repairs Socket outlet 2 in 1, 5 pin, 5 Amps complete all as specified and as directed.
S&F in repairs Two way switch 5 Amps, 230 volts complete all as specified and as directed.
S&F in repairs Fan electronic dimmers 450W, 250V flush type on the existing laminated sheet complete all as specified and as directed.
S&F in repairs Ceiling rose, surface bakelite 65mm x 50mm, 3 terminals fixed on PVC Round Block complete all as specified and as directed.
S&F in repairs Bell push 230 volts, AC complete all as specified and as directed.
S&F in repairs Call bell ding-dong 230 volts complete all as specified and as directed.
S&F for New E-Lite LED Curve, high lumen batten (white/warm white) with efficacy of 100 lumens in 20 W complete all as specified and as directed. Make- Havells Cat part No LHEXBXPNIN1W020 or equivalent to Crompton/ Syska
S&F in replacement of New E-Lite LED Curve, high lumen batten (white/warm white)with efficacy of 100 lumens in 10 W complete all as specified and as directed. Make- Havells Cat part No LHEXBXPNIN1W010 or equivalent to Crompton/ Syska
S&F in replacement of New E-Lite LED Curve, high lumen batten (white/warm white)with efficacy of 100 lumens in 05 W Make- Havells Cat part No LHEXBXPNIN1W005 or equivalent to Crompton/ Syska complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
LED City 4 decorative wall light fixture made up of polycarbonate fitting alongwith LED 15W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed. Make- Havells Or Equivalent make in Wipro /HPL
S&F in replacement Aristo 1x8W CFL TU/40W Candle E14 wall mounting, SS finish fixture with opal glass diffuser suitable for 40W incandescent candle lamp complete all as specified and as directed. Make :- Havells Cat Part No - LHJE01106499 or equivalent to HPL/ Phillips/ Wipro.
LED Sana Decorative wall light made up of high grade engineering plastic material suitable for retrofit alongwith LED 15W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed. Make- Havells Cat part No LHFOGBE1TZ1W035 or Equivalent make in Wipro /HPL
LED Stylo Decorative wall mounting, champagne gold finish fixture with plastic body suitable for retrofit alongwith LED 15W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed. Make- Havells Cat part No LHFOECE1TZ1OO14 or equivalent make in Wipro /HPL
LED Venza Decorative wall mounting, SS finish fixture with opal glass diffuser suitable for retrofit alongwith LED 12W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed. Make- Havells Cat part No LHJC02108499 or equivalent make in Wipro /HPL
PVC casing caping of size 20/25mm including all accessories ie Nail, tee, elbow etc complete all as specified and as directed.
Angle lamp holder PVC/Polycarbonate with back plate with LED Lamp 10 Watt suitable for fittings including taking down old one complete all as specified and as directed.
Single pole and neutral enclosure surface mounted 240 volts with 2 pin and earth plug and socket with one single pole MCB 20 Amps with indicator of make wipro/equivalent in Havells/Bajaj complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm drawing through existing surface / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed. Make: Finolex/ Polycab/ Havells.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm drawing through existing surfacce / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 4 Sq mm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed. Make: Finolex/ Polycab/ Havells.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm drawing through existing surfacce / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 2.5 Sq mm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed. Make: Finolex/ Polycab/ Havells.
Sub main wiring with four single core PVC insulated with copper conductor cable stranded of size 6 Sqmm drawing through existing surface / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 4 Sq mm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed. Make: Finolex/ Polycab/ Havells.
S&F in repairs Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way double door complete with appropriate size bus bar,neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed. Make - Legrand/Havells/Schneider
Sheet metal enclosures for DBs when MCBs to be used double door DB SPN 8 way 240 volts with 200 Amps rated bus bar and neutral link in cluding chases wall for dixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed. Make - Legrand/Havells/Schneider
Sheet metal enclosures for DBs when MCBs to be used double door DB SPN 4 way 240 volts with 200 Amps rated bus bar and neutral link in cluding chases wall for dixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed. Make - Legrand/Havells/Schneider
S&F in repairs Sheet metal enclousers,TPN Distribution board 4 way , double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed. Make - Legrand/Havells/Schneider
S&F in replacement MCB Single Pole, 240 Volt, 10 KA Ç' Curve, Rating 6 to 32 Amps complete all as specified and as directed. Make - Legrand/Havells/Schneider
S&F in replacement MCB Single Pole and Neutral , 240 Volt, Rating 40 to 63 Amps, 'C' curve complete all as specified and as directed. Make - Legrand/Havells/ Schneider
S&F in repairs MCB Triple Pole and Neutral ,415 Volt,Rating 63A 'C' curve as Incoming in MCB TPN DB. Make - Legrand/Havells/Schneider complete all as specified and as directed.
VTPN MCCB DB Double Door Including 100 Amp MCCB, 16 kA ( as Incommer ) 4 way double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and as directed. Make - Legrand/Havells/Schneider
Earthing complete with galvanised steel earth plate electode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mash and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES SSR 2009 (Part I) connected to main control board and testing on completion complete all as specified and as directed.
S&F for LED Street light 30W including angle arms (Bracket) with 25mm dia GI pipe. Make-Havells Cat Part No- ENDURACITYLITEPLATPLUS30WLED757SASYBOPC or equivalent to Crompton/ Syska complete all as specified and as directed.
S&F in replacement environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing complete all as specified and as directed.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 16 sqmm 4 core, complete all as specified and as directed.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 10 sqmm 2 core, complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. Note:- Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mm x 115mm x 75mm complete all as specified and as directed.
GI tubing light grade 32mm bore along the wall/laid in trenches/in duct/in culvert/road crossing/ passing through cable or fixing along pole and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed.
Taking out geyser carefully from its location of any make & capacity 25/35/50Ltrs and dismantling the same for replacement of parts described under items here-in-below and installed with complete repair and re-assembling and installation of complete set to work complete all as specified and as directed. Note :- Labour for taking down and re-fixing all type of spare parts included in this items & all type of Defective parts/glass wool will be measured and paid saperatly under respective items of BOQ as supply only.
Supply only PVC connection with two Nos of adopter and washer of size 300 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply only PVC connection with two Nos of adopter and washer of size 450 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply only SS connection heavy duty (steel type) connecting with two Nos of adopter and washer of size 300 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply only Head assy/Apparatus plate heavy duty 18 SWG with rubber gasket of suitable size for 25/35/50 Ltr cap geyser of any make complete all as specified and as directed.
Supply only Heating element any type (i.e Cup/ threaded/triangular) 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply only Heating element complete set for Havells geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply only Heating element complete set for Bajaj Calanta geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply only Heating element complete set for Racold geyser of 2.0 KW, vertical plate type/horizontal triangular type 220/230 volts (ISI marked) complete all as specified and as directed.
Supply only Instant Water heating coil for Geyser, Coil Type, (ISI Marked) 3KW, suitable for 1 ltr to 5 ltr instant geysers complete all as specified and as directed.
Supply only thermostat ranging 60 degree to 90 degree adjustable type, long, Operative on 250 Volts complete all as specified and as directed.
Supply only Safety Plug "Brass" (ISI marked) complete all as specified and as directed.
Supply only Rubber gasket for apparatus plate suitable for any 25/35/50 ltr cap geyser complete all as specified and as directed.
Supply only Element holding clamp suitable for geyser of cap 25/35/50 ltr complete all as specified and as directed.
Supply only stainless steel inner tank Capacity 25 Ltr heavy duty (Approx height 304 mm) with SS 304 Grade complete all as specified and as directed.
Suppply only stainless steel inner tank capacity 35 ltr heavy duty (Approx height 396 mm) with SS 304 Grade complete all as specified and as directed.
Supply only stainless steel inner tank capacity 50 Ltr (Approx height 507 mm) with SS 304 Grade complete all as specified and as directed.
Supply only indicator lamp, round/square, green /red as per requirement complete all as specified and as directed.
Supply only PVC insulated Top plug 3 pin 15 Amp (ISI Marked) complete all as specified and as directed. Make - Anchor/Havells
Supply only Steel sheet outer body of Geyser suitable for 25/35/50 ltr capacity complete all as specified and as directed.
Supply only glass wool for Geyser of any Make for capacity 25/35/50 ltr complete all as specified and as directed.
Taking up or down steel water tubing 15 mm/20 mm dia with fitting and for cleaning including refixing/remove from the site complete all as specified and as directed.
Steel water tubing 15 mm dia (medium grade) galvanised with all fittings including short lengths, fixed to wall and ceiling or laid in floor complete with all fitting (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed.
Pressure release valve, dead weight type, (ISI marked) complete all as specified and as directed.
Non return valve 15 mm dia pipe brass made (ISI marked) complete all as specified and as directed.
15 mm Brass Angle Valve (ISI marked) complete all as specified and as directed.
15 mm Bib Tap (ISI marked) complete all as specified and as directed.
GI Fastner bolts including nuts washer off sizes 4/6 Inch suitable for fixing of any capacitty geysers as required at ite to the entire satisfaction of Engineer-in-Charge.
PVC Copper cable flexible 3 core round heavy duty size 40/0.0076 suitable for geyser any capacity to the entire satisfaction of Engineer-in-Charge.
Taking down Geysers (cap 25/35/50 ltr), cleaning its dust particles, one coat of synthetic enamel white spray painting ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to socket etc complete after completing the wiring complete all as specified and as directed.
Supply of bolts, nut and washers for Geysers complete all as specified and as directed.
Sheet metal enclosures for DBs when MCBs to be used Single door DB SPN 2 way 240 volts with 200 amps rated bus bar complete all as specified and as directed.
De-scaling of geysers tank 25/35/50 ltrs capacity complete all as specified and as directed.
Solar water heating element for any type solar heater of any capacity 3 Kw as required on ground or complete all as specified and as directed.
Repairing the geyser in situ at its location including replacement of spare parts like heating element, thermostat, indicator, fusible safety vent plug, NRV, GI nipple, PVC connection, stop valve, plug top etc. of any make & capacity 25/35/50 Ltrs geyser and testing complete all as specified and directed. Note :- Spare parts like heating element, thermostat, indicator, fusible safety plug, NRV, GI nipple, PVC connection, stop valve, plug top, 15 Amp S/s combined shall be measured and paid saperately under respective items of BOQ as supply only complete all as specified and as directed.
Note for srl item No 99, here-in-before:- (a) Contractors representative/engineer will report to JE E/M/Engr-in-Charge Daily at fore noon and after noon to collect routine/urgent works related to geyser complaints till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, screws, nuts, bolts, washers etc. required to accomplish the job. The contractor will also ensure as availability of every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24 hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty.
(b) The penalty shall be applicable to the contractor if the delay is noticed by Engr-in-Charge more than 12 hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge/JE E/M shall handover the slip containing specifications of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the job immediately and shall report to Engr-in-Charge within 12 hrs. The contractor will keep his tradesman in stand by for attending any routine/Urgent works from the executive If the nature of job is such that the workcannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the EE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 20 per job shall be deducted from the dues of the contractor. Please note that this penalty ois exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the deptt. the decision of the Accepting Officer is this regard shall be final and binding.
(c) One loged Complaints slip, is to be treated as One Complaint in irrespective of No. of Repairs mentioned in the same. (d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours (0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs) Other than the Regular complaints during working Hrs (0900 Hrs to 1700 Hrs) (e) Procurement of Security gate passes of the Electrician, will be sole responsibility of the Contractor as per CA provision.
NOTE - (i) Replacement of unserviceable parts shall be measured and paid for separately under respective items as Supply Only. (ii) On testing after completion of repair, if the proper functioning without leak, not obtained at Engr-in-Charge satisfactory level, the repairing will be re-done by the contractor at his own costs and the cost for the same shall be deemed to be included in the quoted rates. (iii) The contractor shall maintain/open a Workshop and keep his electrician ready during working Hrs (0900 Hrs to 1700 Hrs) for geyser repair, inside MES store Yard so that all the repairing/Descaling/changing parts of geysers will be done in proper manner, MES authorities will not be issued any Geysers/winter appliances, any type, for repaire puropse to the contractor for his outside workshop.
DEV RAJ MAGOTRA
vmd traders
SINGH CONST CO
M/S Chib Engineers
m/s shanti trading company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .