Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹52.8 L+₹3.3 L (6.57%)Rejected-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹55.0 L+₹5.5 L (11.0%)Rejected-AOC 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹61.1 L+₹11.5 L (23.2%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹62.1 L+₹12.5 L (25.3%)Rejected-AOC NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-AOC Rejected |
Tender Value
₹49.7 L
EMD Value
₹99,440
Closing Date
26 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
PROVN OF 134 X GEYSER AND 02 X TRANSFORMER WITH CABLED AND PANELS OF ZONE 6 AND BHAGAT ENCLAVE AT BABINA CANTT UNDER GE BABINA
2022_MES_567345_1
CWE/JHA/BAB/TOKEN/60 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BABINA
As per tender documents
9 documents required · 9 mandatory
₹500
GE BABINA
₹99,440
Yes
9 Feb 2023
5 Dec 2022
2 Jan 2023
5 Dec 2022
26 Dec 2022
20 Dec 2022
Amount
Supplying, installation, connecting, testing and commissioning of outdoor type distribution transformer of 315 KVA, 11 KV/ 0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound step down enrgy saving ( level 2) floor mounted complete with first filling ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group DYN -11 complete all as specified and as directed. Note - (a) The ambient temprature shall be 48 degree Centigrade when measured by the resistance method after continuous full load run . (b) The transformer shall be complete with standard fittings all as specified and conforming to IS:335 of 1993 for oil and IS: 1180 Part -I of 2014 for transformer and comprising of followings:- (i) One No cable box on LV side (secondary side) consisting of 04 Nos of porcelain bushing with bushing rods and another cable box on HV side (primary side) consisting of 03 Nos of porcelain bushing with bushing rods etc complete with nut, washers, cable gland etc. (ii) Oil conservator tank with filter type drain valve and oil level gauge. (iii) Oil level indicator with minimum and maximum marking (iv) Dehydration silica gel breather assembly with first fill of dehydrating agent and oil seal. (v) Explosion vent with diaphragm complete. (vi) Thermometer pocket on tank cover. (vii) Dial type thermometer vapour pressure having range 0-120 degree C with max reading pointer max temp indicator and resetting device. (viii) Rating plate with terminal marking.
(ix) 02 Nos earthing terminal on tank and cover for fixing earth strip of size 32 x 6 mm. (x) Oil level gauge and oil drain filter valve. (xi) Lifting hook. (xii) Oil filler hole with cap /plug with connection complete. (xiii) Air relief valve plug. (xiv) Detachable rollers - 04 Nos (xv) Extra bushing for Neutral out side the cable box for independent earthing for neutral earth. (xvi) First fill of fresh transformer oil confirming to relevant IS and tested up to 40 KV die electric strength.
Supplying, installation, connecting, testing and commissioning of outdoor type distribution transformer of 200 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound step down enrgy saving ( level 2) floor mounted complete with first filling ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group DYN -11 complete all as specified and as directed by the Engineer in Charge. Note - (i) The ambient temprature shall be 48 degree Centigrade when measured by the resistance method after continuous full load run . (ii) The transformer shall be complete with standard fittings all as specified and conforming to IS:335 of 1993 for oil and IS: 1180 Part -I of 2014 for transformer and comprising of followings:- (i) One No cable box on LV side (secondary side) consisting of 04 Nos of porcelain bushing with bushing rods and another cable box on HV side (primary side) consisting of 03 Nos of porcelain bushing with bushing rods etc complete with nut, washers, cable gland etc. (ii) Oil conservator tank with filter type drain valve and oil level gauge. (iii) Oil level indicator with minimum and maximum marking (iv) Dehydration silica gel breather assembly with first fill of dehydrating agent and oil seal. (v) Explosion vent with diaphragm complete. (vi) Thermometer pocket on tank cover. (vii) Dial type thermometer vapour pressure having range 0-120 degree C with max reading pointer max temp indicator and resetting device. (viii) Rating plate with terminal marking.
(ix) 02 Nos earthing terminal on tank and cover for fixing earth strip of size 32 x 6 mm. (x) Oil level gauge and oil drain filter valve. (xi) Lifting hook. (xii) Oil filler hole with cap /plug with connection complete. (xiii) Air relief valve plug. (xiv) Detachable rollers - 04 Nos (xv) Extra bushing for Neutral out side the cable box for independent earthing for neutral earth. (xvi) First fill of fresh transformer oil confirming to relevant IS and tested up to 40 KV die electric strength.
Supplying, laying, jointing & commissioning in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, (Earthed) cross sectional area 95 sqmm 3 core as per IS 7098 Pt-II complete all as specified and directed.
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and directed.
M&L for fine and clean sand free from sharp materials in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
M&L for PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified and directed.
M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified and directed.
S&F of cable jointing Kit 11 KV (earthed) grade cable for outdoor type termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply, installation, testing and commissioning of lightening arrester SMX type complete with all fittings transmission class, discharge capacity 65 Kilo Amp suitable for system voltage 11 KV complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, glavanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 core complete all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, glavanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
M&L for switch air break gang operated triple pole , mechanically operated mounted on HT insulators (12 insulator type) and MS steel frame with operating mechanism worked from ground level with 11 KV insulation for current rating up to 200 amps 11000 volts with locking arrangement, MS clamps, nuts, bolts and washers etc also incl drop out expulsion type fuse, single pole up to 25 Amps, 11000 volts fuse barrels, incl two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and as directed.
M&L SMX type lightning arrestors confirming to IS-3070 (Part-1) having voltage rating 12 KV, rated frequency 50 Hz, nominal discharge current 65 KA (heavy duty) expulsion type transmission class complete with all fittings suitable for 11 KV, 3 phase earthed distribution system complete all as specified and directed.
Supplying laying jointing, testing & commissioning in trenches, fixed on poles/ drawing through pipes HT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor, 11000 volts grade (Earthed) crossectional area 95 Sqmm 3 core complete all as specified and directed.
Supplying laying jointing, testing & commissioning in trenches, fixed on poles/ drawing through pipes LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables, heavy duty with stranded aluminium conductor, 1100 volts grade (Earthed) crossectional area size single core 400 sq mm complete all as specified and directed.
All as per Ser item No 15 but of size 240 qmm 3.5 Core complete all as specified and directed.
All as per Ser item No 15 but of size 150 sqmm 3.5 Core complete all as specified and directed.
All as per Ser item No 15 but of size 25 sqmm 4 Core complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth lead connected to equipments and watering pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and testing of earthing complete and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . 3. On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth lead connected to equipments and watering pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and testing of earthing complete and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . 3. On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.
M&L for earthing complete with galvanised steel earth plate electrode of size 600X600X6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to galvanised iron strip of 32 x 6 mm as earth lead by means of bolts nuts check nuts & washers of galvanised iron or steel ,surrounded by charcoal of coke and salt, water pipe 20mm bore GI medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stone aggregate, 50 mm thick cover of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia TMT bars @ 80 mm c/c boath ways including excavation and earth work and removal of surplus soil to distance n exc 50 m complete all shown in electrical plate No 3 of SSR part- 2010 complete all as specified and directed. Note :-(i) The cost of GI earth lead & G I pipe of 7.50 mtr length for protection of GI wire and excavation work for pit shall deemed to be included in this item. (ii) Earthing test will be carried out and if desired result not achieved and the earthing will be redone to achieve desired result without any extra payment. (iii) Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
M&L for factory made PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
M&L for factory made PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed.
M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 50 mm dia bore complete all as specified and as directed.
M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 80 mm dia bore complete all as specified and as directed.
M & L for road cutting incl excavation in trenches for laying HT/LT UG cable in pipe not exc 45 cm wide and n.exc 90 cm depth or as per site requirement making good the disturbed surfaces with cement concrete (1:3:6) type C-1 and top surface neatly finished as per existing to match with the existing complete all as specified and directed.
M&L for mild steel cross arms, bracings supports, clamps and back plates fabricated from structural steel sections, channel including nuts, bolts, washers welding, bending cold or not, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar, outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following :-
(a) Aluminium bus bar four Nos 1000 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code -01 Set Incoming:- (b) MCCB , 04 Pole, 630 Amps fixd type breaking capacity Icu- 50 KA at 415 volt, conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 Nos Outgoing:- (c) Switch disconnector fuse unit (SDFU) 200 Amp TPN SDF suitable for DIN bolted fuse link with HRC fuse of capacity 200 Amp 4 pole type IEC 60947-3 Part-IS/IEC-60947-3 Part-I -02 No (d) Switch disconnector fuse unit (SDFU) 160 Amp TPN SDF suitable for DIN bolted fuse link with HRC fuse of capacity 160 Amp 4 pole type FN 160 FP conforms to IEC 60947-3 Part-IS/IEC-60947-3 Part-I - 02 No, (e) Switch disconnector fuse unit (SDFU) 125 Amp TPN SDF suitable for DIN bolted fuse link with HRC fuse of capacity 125 Amp 4 pole type FN 125 FP conforms to IEC 60947-3 Part-IS/IEC-60947-3 Part-I - 01 No, (g) Spare way for Switch disconnector fuse unit (SDFU) 200 Amp 4 way - 01 Nos
Supply & inreplacement , commissioning and testing factory made LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following complete all as specified and directed.
(a) Aluminum bus bar four strips 600 Amps ,415 volts,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. Incoming:- (b) MCCB, 04 Pole, 400 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c ) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 Nos (Ics=Icu=100%) (d) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 16 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) (e) Spare way for MCCB 125 Amp 4 way - 01 Nos (g) Analoge type volt meter 0-500 volt - 1Set. (h) Indication lamps R,Y,B LED type with 3 Nos – 1 Set. (f) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's. PCC foundation with brickwork and plastering for panel included in unit rate. Note :- Panel drawings & make of MCCB/SDFU will be submitted by contractor for approval from GE before ordering the panel.
Supply, erecting and fixing in replacement of true vertical position, steel tubular swaged pole (410 SP-55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.). The quoted rate includes cost for shifting of existing Cross arms, bracing, ACSR conductors insulators, GI wire from eisting pole to new poles. Note :- Excavation including earth work and PCC foundation will be measured and paid separately.
S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling for erection of pole and mass concrete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling for erection of pole/fncing post/stay and mass concrete including form work for poles all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed.
M & L for conduit point wiring complete with PVC insulated and unsheathed flame retardant los smoke low smoke ( FRLS ) cable of 2.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 19 mm dia, clip, with MS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and directed .
Material and labour for submain wiring with PVC insulated, unsheathed 2 single core cable 1100 vols grade FRLS with stranded copper conductors of size 4.0 sq mm (Nominal area) drawn into conduit, (existing/new) with and including 4.0 sq mm green PVC insulated FRLS stranded copper conductor cable as contineous earth wire terminated with copper lugs / thimbles all as specified and as directed. Note : New conduit and conduit accessories shall be measured and paid separately.
M&L for rigid non-metallic PVC conduit, medium grade, not less than 19 mm dia (external) ISI marked (on surface) including all accessories/fittings such as tees, bends, elbows, reducers, bell mouth, tube ends and fixing accessories such as couplers, lock nuts, GI saddles, pipe hook etc complete all as specified and directed.
S & F sheet metal enclosure double door concealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar 8 ways 240V including taking down complete all as specified and directed.
S&F MCB SPN 40 Amp , 240 V , 10 KA 'C' Series complete all as specified and directed with copper lugs complete all as specified and directed.
S&F MCB single pole 6 to 40 Amp,10KA 'B' series complete all as specified and as directed with copper lugs complete all as specified and directed.
S&F storage type water heater (Geyser),5 star BEE rating, 230 Volt AC, 25 Ltrs capacity comprising Stainless steel inner tank,suitable heatng element, thermostate with adjustable temperature setting , indication lamps provision for inlet outlet and air vent connections & NRV,inclucluding all fixing arrangement such s faster bolts, nuts washers etc complete including making good disturbed wall surfaces matching with the existing surfaces and finishing all as specified and directed.
S&F PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long complete all as specified and directed.
S&F stop valves, cast copper alloy, srewed down , high pressure, with cruntch or butter fly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm dia complete all as specified and directed.
S&F Bib taps, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe and fixed of size 15 mm dia complete all as specified and directed.
Supply and fixing galvanised mild steel water tubing of 15 mm dia bore medium grade ISI marked with and incl all fittings like bends, elbow, Tee, reducer sockets & union etc laid in trenches, under floor or fixed to walls / ceilings complete all as specified and directed.
S&F MCB protected power socket unit with sheet steel enclosure include power socket , mini MCB SP 20 A ,220V,50 Hz complete all as specified and directed.
ROHIT ENTERPRISES
A K ENTERPRISES
M/s Raghav Traders
M/S Ritu Tandon
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .