Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹49.5 L+₹2.5 L (5.26%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹49.6 L+₹2.6 L (5.54%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹49.8 L+₹2.8 L (5.94%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹46.8 L
EMD Value
₹93,680
Closing Date
23 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bhisiana
GE (AF) Bhisiana PIN-151201
as per BOQ/ Price Schedule
2023_MES_615859_1
GE/BHI/CAP-10/23-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Bhisiana
as per NIT/ Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Bhisiana
₹93,680
25 Oct 2023
26 Aug 2023
25 Sept 2023
26 Aug 2023
23 Sept 2023
9 Sept 2023
26 Aug 2023 - 4 Sept 2023
Amount
BUILDING WORKS (B/R PORTION)
Excavation over areas not exceeding 1.5 M deep and getting out in Soft/ Loose Soil complete all as specified and directed by Engineer in Charge.
Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft/loose soil, complete all as specified and as directed by Engineer in Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft /loose soils, complete all as specified and as directed by Engineer in Charge.
Removing excavated material exc 250 mtr n exc 500 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soils, complete all as specified and as directed by Engineer in Charge.
M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregates ) lean concrete as in foundation, filling and mass concrete including bed of drains complete all as specified and directed by Engineer in Charge.
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4 including Corbelling and arches, complete all as specified and as directed.
M&L Pre-cast cement concrete nominal mix design type B-1, 1:2:4 (12.5 mm graded stone aggregate) in drain cover slabs, set in cement mortar (1:4) including necessary form work complete all as specified and as directed by Engineer in Charge.
S&F 1.0mm thickness of Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated including supporting arrangement, gear operated type with bevel gear box and crank handle as per manufacturer instruction, complete and making good surrounding area, complete all as specified and directed by Engineer in Charge.
S&F Ball Bearing suitable for Rolling Shutter, complete all as specified and directed by Engineer in Charge.
M&L Rendering 15mm thick in Cement Mortar 1:4 on Fair Faces of Brick Walls or on Concrete Surfaces plastered Surfaces Finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer in Charge.
M&L for PCC (1:2:4) type B-1(using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, seismic and other similar bands, plinth bend, etc including weathering slightly rounded or chamfered angles and throuting , including necessary form work etc complete all as specified and as directed by Engineer in Charge.
Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars, etc, built in cement mortar complete all as specified and as directed by Engineer in Charge.
Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed by Engineer in Charge.
M&L for Prepration of old decorated surfaces of walls including cornices pilasters etc (plastered or unplastered surfaces),washing rubbing down and stopping of distempered and painted surface and applying two coat of oil Emulsion Distemper (OBD) complete all as specified and as directed by Engineer in Charge.
M&L for Virified Ceramic tiles light shed 10 mm thick (square/ rectangular) polished, area of each tiles n.exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick cement screed bedding layer in cement mortar 1:6, complete all as specified and directed by Engineer in Charge.
M&L for Virified Ceramic tiles light shed 10 mm thick (square/ rectangular) polished, area of each tiles n.exceeding 0.36 sqm, in walls etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over including 10mm thick screed bedding layer in cement mortar 1:4 walls, finished even and rough to receive the top layer complete all as specified and directed by Engineer in Charge.
M&L for Fair finish form work to sides and soffits of floor or lintel beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams etc. complete all as specified and directed by Engineer in Charge.
M&L for fair finished and flat Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engineer in Charge.
M&L Reinforced Cement Concrete M-25 (Design Mix) (20mm gradded stone aggregate) Foundations,foundation beams; plinth beams; bases for columns, etc.; basement slabs,and mass concret and the like, complete all as specified and as directed by Engineer in Charge. NOTE : Reinforcement will be Measured and Paid for separately under appropriate Item.
M&L for TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed by Engineer in Charge.
-ditto- but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, complete all as specified and as directed by Engineer in Charge.
M&L for Mild steel, plain, black sheet 1.60 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. complete all as specified and as directed by Engineer in Charge.
M&L for Mild steel Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed by Engineer in Charge.
M&L for 12 mm thick prelaminated particle board exterior grade,prelaminated both sides with decorative choice laminaions fixed with suitable screw to frame complete all as specified and as directed by Engineer in Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc, complete all as specified and as directed by Engineer in Charge.
M&L for Preparation of new steel iron surfaces of any description, over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer in Charge.
M&L for Preparation new plastered surface of wall, concrete surface and applying two coats of all weather exterior emulsion paints in camouflaging pattren @1.43 litre/10 sqm over and including priming coats of exterior primer of same make applied @0.9 litre/10 sqm as per new sigma pattern generated by station authority and RGB value variation from 110 to 171 by using 4 to 5 colour shades as per approved pattern at a height n.exc 25 mtr as per sample approved by GE, complete all as specified and directed by Engineer-in-charge. Note: The % of the colour may change without any financial effect.
S&F for Mild steel screw boltsof 16 to 20 mm neck dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 22.5 cm and n exc 50 cm long, complete all as specified and directed by Engineer-in-charge.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment, complete all as specified and directed by Engineer-in-charge.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for windows, ventilators and fixed partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F of Sheet glass, 5.0 mm of thickness, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer in Charge.
M&L for 12 mm thick prelaminated particle board exterior grade,prelaminated both sides with decorative choice laminaions fixed with screw to aluminium frame complete all as specified and as directed by Engineer in Charge.
ROAD /PATH/CULVERT (B/R PORTION)
Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/ Loose soil complete all as specified and directed by Engineer in Charge.
M&L for 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified and directed by Engineer in Charge.
M&L for 80 mm thick Machine pressed precast concrete interlocking paver block M 40 grade with grey cement and no pigment confirming to IS 15658-2006 complete all as specified and directed by Engineer in Charge.
M&L for 60 mm thick Machine pressed precast concrete interlocking paver block M 35 grade with grey cement and no pigment confirming to IS 15658-2006, complete all as specified and directed by Engineer in Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer in Charge.
M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and directed by Engineer in Charge.
Removing Excavated soils exceeding 250 Mtr but not exceeding 500 Mtr and depositing where directed, complete all as specified and directed by Engineer in Charge.
FENCING/ GATES (B/R PORTION)
Excavation in post holes each not exceeding 0.50 cum , getting out, returning filling in and ramming earth or broken rubble mixed with earth in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed by Engineer in Charge.
Excavating in trenches not exceeeding 15 m wide and not exceeding 1.5 m deep for foundations, etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 Sqm on plan and getting out in ordinary soft/loose soil complete all as specified and directed by Engineer in Charge.
Returing, filling in, spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified & directed.
Removing excavated material exceeding 250 mtr not exceeding 500 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soils.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:4, complete all as specified and directed by Engineer in Charge.
M&L for PCC (1:2:4) type B-1(using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, seismic and other similar bands, plinth bend, etc including weathering slightly rounded or chamfered angles and throuting , including necessary form work etc complete all as specified and directed by Engineer in Charge.
M&L 15mm thick cement plaster in cm 1:4 on fair faces of brick or concrete wall surface finished even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered wall surfaces and applied two coat of cement based paint over a coat of wall primer complete all as specified and directed by Engineer in Charge.
M&L for Cement Concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates ) lean concrete as in foundation, filling and mass concrete complete all as specified and directed by Engineer in Charge.
M & L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregates ) lean concrete as in foundation, filling and mass concrete complete all as specified and directed by Engineer in Charge.
M&L for Mild Steel Frame work as in conforming to (Fe-500 or Fe-550-0) as in wind ties,posts and struts as directed including drilling holes, notching for wire etc cutting and twisting necessary drilling bolting and riveting or welding including FI 40 x 6mm etc and similar works complete all as specified and directed by Engineer in Charge.
Supply only Chain link MS galvanisd fencing, any size or type all as specified and directed
Fixing only Chain link MS galvanisd fencing, any size or type all as specified and directed.
S&F galvanized 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and including provision of galvanized mild steel wire complete all as specified. (Note :- Each line shall be measured and paid for separately).
Providing and fixing punched tape concertina fencing 540 mm erected dia (i.e 610 mm dia coilmade with high tensile strength galvanised mild steel wire 2.60 mm dia as per IS-4454 strip material (galvanized MS strip as per IS-1730) upto 3.0 meter helght of wall or fencing tied with G.I staple and G.I clips to retain horizontal including necessary bolts or G.I barbed wire tied to angle iron with loop spacing 250+ 20 mm , coil length 9m and fixing and laid in position etc. makes approved by GE confirming to the specification complete all as specified and as directed by Engineer in Charge.
M&L for Mild steel in flat, round or Square bars in available lengths cofirming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed by Engineer in Charge.
S&F for Mild steel screw bolts of 11 to 15mm neck dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 5 cm and n exc 10 cm long, complete all as specified and as directed by Engineer in Charge.
S&F steel work in tubular section including special shaped washer etc. complete using ERW or induction butt welded tubes section with gusset plates ,rails,braces etc complete drilled for fixing of steel gate sheeting or other covering,doors ,etc to be prepared for sliding with and including either hooks and hinges or steel sliding door fittings with roller arrangements including ground wheels (exclusive of steel sheeting or other covering ,runing rails and guides ) and hanging also fastning and fixing complete all as specified and directed. conforming to I.S 1161-1998 grade st 240 complete all as specified and directed by Engineer in Charge.
S&F joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe-410-quality A complete all as specified and directed by Engineer in Charge.
S&F Mild steel plain black sheet 1.6mm thick in wall cladding,steel gates and similar work cut to size holes punched including round head screws clout nails or rivets and fixed to steel framing with plain 40mm lap joints with riveted or welded seams,including bending or turning up mitered angles,etc complete all as specified and directed by Engineer in Charge.
M&L for Preparing new steel iron surfaces of any description, over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer in Charge.
M&L for Preparing new steel iron surfaces of any description, n. exe 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer in Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section embeded in ground, including taking out embedded portion and making good disturbed ground, complete all as specified and as directed by Engineer in Charge.
Dismantling Fencing wire mesh of any description such as Barbered wire Fencing/Chain Link fencing etc complete all as specified and as directed by Engineer in Charge.
M&L for Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing cofirming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed by Engineer in Charge.
EXTERNAL ELECTRIC SUPPLY (E/M PORTION)
Excavation in trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 metre and depositing where directed at a level not exc. 1.50 metre above the starting point, complete all as specified and as directed.
M&L Sand (Fazilka) Cushioning (dry) in trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (15 Cm in depth before laying the Cable and 8 Cm in depth after laying the Cable) and consolidated (punned) upto 18 Cm thickness, complete all as specified and as directed. NOTE :For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for Brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
S&F 16A 3-Pin and Industrial Earth Plug and Socket with 220-250 Volt and Connecting up, complete all as specified and as directed by Engineer in Charge.
M&L for Shifting of Electric Poles from its existing position to new position approx 6 Metre from Old Position with the help of T&P i.e., Hydraulic , JCB etc including demoliyion of coping, foundation of polie in existing location, excavation, returning, Filling removal in new location by dis connecting electrical connection , Brackets, Junction Box, Conduit pipes, wire any type fittings amd reconnect after erection of poles at its new location, complete all as specified and directed by Engineer in Charge.
Supply and fixing 210 watt LED Flood light luminaire of epoxy powder cated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>100 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply, installing, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps including 1 No MCB SPN 06 Amps on suitable foundation and Cable entries should be in proper metalic glands only.
M&L for Plain Cement Concrete (1:3:6) type C-1 with 20 mm gradded stone aggregate for copping of poles Pedestal (PCC) including necessary form work complete all as specified and directed by Engr-in-Charge.
M&L for Plain Cement Concrete (1:3:6) type C-2 with 40 mm gradded stone aggregate for foundation of poles/ stray/ strut including necessary form work complete all as specified and directed by Engr-in-Charge.
M&L for Stainless steel legrand wire mesh cable tray size brand cable tray coating galvanosed shape ladder colour metalic silver material grade ISO 9223, water proof degree Item code 1506-43372, complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
M&L for Removing normal earthing and M&L for commissioning, installation and testing of maintenance free UL approved copper bonded earth rod of 10 feet length, 17.2 mm dia. made of high tensile low carbon steel rod , molecularly bonded with 99.9% electrolytic grade copper on outer surface ( minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 50 X 6 X 200 mm for connection. The rod and exothermic joint together successfully tested at 25 KA fault current by CPRI with 50 Kg eco friendly earth enhancing compound with each earth rod. The earth pit should be 125 mm dia. the compound should comply to IEC:62561-7 having passed leaching, corrossion, sulphur and resistivity test as per IEC: 62651-7 by NABL accredit Lab with FRP earth pit cover of top size lockable Lid. It includes GI Protection pipe light grade of size 40 mm dia. with GI strip of size 32X6 mm upto test point including connecting of Strip between two earthing complete all as specified and directed by Engr in charge. Note: (a) The test result of each set of earthing is less than 1 Ohm. All earthing test will be carried out in presence of MES Rep, manufacturer Rep and test result will be recorded in a register with sign of manufacturer & Engr-in-charge. (b) Earth enhancing compound (PROCEM) ECS GB 25 tested as per IEC 62561-7-25Kg. (c) Chemical earthing will be installed by manufacturer Rep and purchase voucher of earthing will be produced before payment. Payment shall be made only after getting satisfactory result.
INTERNAL ELECTRIFICATION (E/M PORTION)
M&L for Concealed Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 19mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 32 Amp, 240 Volt and Connecting up including concealed in wall, complete all as specified and as directed.
S&F Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC Conduit medium grade 25mm dia including making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge. Note: (a) The quoted unit rate shall include cost of PVC Conduit (b) Two Runs of Copper cable along with One Runs for earthing and one Run of PVC Conduit shall be measured as one unit.
S&F Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC Conduit medium grade 19mm dia including making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed by Engineer in Charge. Note: (a) The quoted unit rate shall include cost of PVC Conduit (b) Two Runs of Copper cable along with One Runs for earthing and one Run of PVC Conduit shall be measured as one unit.
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 63 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable Lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes, complete all as specified and as directed.
S&F MCB Single Pole & Neutral, 40 Amp, 240 /415 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
S&F MCB Single Pole 40 Amp, 240 /415 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz , 35mm2 Terminal Capacity insulated sliding shutter including Connecting up and Fixing in DB of any make/ type, complete all as specified and as directed.
S&F UPS for 30 Min back up single phase AC input 160V to 260V and output 230V +/- 1% of capacity 5 KVA, complete all as specified and directed by Engineer in Charge.
Supply and install invertor based hi wall split AC with cordless remote of capacity 2.0 TON (Copper coil Both in door & out door Unit) electric driven single phase, 230 volts, New 5 star rating including all accessories like brackets, rubber tubing, copper tubing as required at site, gas charging, with auto filter clean technology etc including testing and commission with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed. Note : (a) All cooling /condensing coil should be copper material. (b) The Quoted unit rate include cost of Brackets for fixing.
Supply and install Voltage stablizer copper winding automatic digital type operation single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stablized at 230 Volt with accuracy of (+/-) 2.5 percent of capacity 5 KVA.
Aman Enterprises
SWARN SINGH AND CO.
M/s BALDEV SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .