Loading…
Loading…
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
5 Aug 2026, 6:00 pm
LT COL MANISH E WASNIK
GE (CENTRAL) DELHI CANTT-10
8825/TOKEN-141/2025-26
2026_MES_756098_2
GE/TOKEN-141/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
22 Jul 2026
22 Jul 2026
7 Aug 2026
22 Jul 2026
5 Aug 2026
29 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for 5 mm thick acrylic sheet of size 200mm x 300mm fixed on wall over suitavle fastener border over the stone ofr building insignia (letter size ht 100mm and 50 mm width) for numbering qtrs, Garrages complete all as specified and directed. | 500 | Each Job | - | - |
| 2 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc complete all as specified and as directed. | 5 | Cum | - | - |
| 3 | M&L Burnt bricks work with whole kiln burnt well burnt old size bricks built in CM 1:4 in walls straight on plan/ exceeding 6 mtrs mean radius complete. | 5 | Cum | - | - |
| 4 | M&L for followings :-
(i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams
(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible from all sides)
(iii) Removal of cover concrete with under cutting of up to a depth of 10mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)
(iv) Cleaning exposed concrete substrate by using water jet.
(v) Removing visible rust along the length of reinforcement using hand tools as approved.
(The Engr-in-charge may order sand blasting if needed)
(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 400 | Sqm | - | - |
| 5 | M&L for providing rust proof /anti corrosive treatment to bars :-
(i) cleaning of all exposed bars (new & old) alround
(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer
(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer.
Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re-bars (those towards the concrete substrate) should not be left without coating .Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 400 | Sqm | - | - |
| 6 | M&L for providing PMM (Polymer modified cementitious mortar) :-
(i) Dry sub strate surface and free of debris & dust
(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).
(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) upto 50 mm thickness.
Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.
(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 400 | Sqm | - | - |
| 7 | S&F in repair of Upvc pipe line (Sch-40) of 32 mm dia for AC drain fixed to wall with suitable fittings like elbo, tee etc and clamping with wall all as specified and directed by Engr-in-Charge.Note rate quoted up to G+5 bldg including scaffolding complete all as specified and directed. | 500 | RM | - | - |
| 8 | S&F in repair 150 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed complete to walls, ceilings or in floors with suitable clamps/bracket including taking down old PVC/CI pipes and necessary cutting through RCC roof and brick work etc (above six storey height) and making good all as specified. | 100 | RM | - | - |
| 9 | S&F in repair of 150mm dia PVC (SWR) TEE any radius with solvent joints, complete all as specified. | 30 | Each | - | - |
| 10 | M&L of Applying Finishing the brick surface with water vapour permeable mortar, UNOFIN CLASSIC basecoat Render for weather resistant&equivalent & high performance façades with CSIV compressive strength, Flexural Strength ≥ 2.5 N/mm2 and water vapour permeability ≤μ15 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material, slabs,pillars, roller blind boxes, around the openings/windows, doors, etc.), with fibreglass mesh to avoid cracks as per manufacturer’s recommendations.including taking down palster or scraping if required. | 800 | Sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_873709.xls
BOQ • 0.32 MB
tenderpage.pdf
Tender Documents • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].