| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | L1 | Accepted-AOC Being the lowest tenderer | |
| 2 | L2₹14.8 L+₹1.2 L (8.88%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | L3₹14.9 L+₹1.4 L (10.1%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-Finance Not being the lowest tenderer | |
| 4 | L4₹16.1 L+₹2.5 L (18.7%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L4 | Rejected-Finance Not being the lowest tenderer | |
| 5 | L5₹19.9 L+₹6.4 L (47.2%)Rejected-Finance NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L5 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Dec 2022, 6:00 pmClosed
GE Chennai
GE Chennai Fort Saint George, Chennai
REPAIRS/ REPLACEMENT OF MAIN SWITCH BOARDS, DISTRIBUTION BOARDS INCLUDING MCBs/MCCBs ALONGWITH SUB MAIN WIRING AND CONNECTED WORKS UNDER GE CHENNAI
2022_MES_560397_2
8625/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE Chennai
As per tender document
7 documents required · 7 mandatory
₹500
GE Chennai
₹40,000
Yes
27 Feb 2023
7 Dec 2022
31 Dec 2022
7 Dec 2022
28 Dec 2022
14 Dec 2022
Amount
Taking down sub main wiring any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
All as per item No.2 herein before but 2 x 6 sqmm + 1 x 6 sqmm earth wire
All as per item No.2 herein before but 2 x 10 sqmm + 1 x 10 sqmm earth wire
All as per item No.2 herein before but 4 x 10 sqmm + 1 x 10 sqmm earth wire
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC casing capping on wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
All as per item No.6 herein before but 2 x 6 sqmm +1 x 6 sqmm earth wire
All as per item No.6 herein before but 2 x 10 sqmm + 1 x 10 sqmm earth wire
All as per item No.6 herein before but 4 x 10 sqmm + 1 x 10 sqmm earth wire
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid Existing PVC conduit on wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed by Engr-in-Charge. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
All as per item No. 10 herein before but 2 x 6 sqmm + 1 x 6 sqmm earth wire
All as per item No. 10 herein before but 2 x 10 sqmm + 1 x 10 sqmm earth wire
All as per item No. 10 herein before but 4 x 10 sqmm + 1 x 10 sqmm earth wire
Taking down DB any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F Sheet metal enclosure for DBs when MCBs to be used, made of CRCA sheet, 1mm thick powder coated paint comforming of relevant IS, 8 way 200 Amps rated bus bar with double door, 240 V double door conform to IP 38 protection
All as per item No.15 herein before but for DBs SPN 4 way, with 200 amp rated bus bar Double door, 240 V.
All as per item No.15 herein before but for DBs TPN 8 way, 415V with Double door.
All as per item No.15 herein before but for DBs TPN 6 way, 415V with Double door.
Taking down MCB any type and any size complete after proper disconneting of electric supply and making good surface complete all as specifided and directed
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning for 100 Amps
All as per item No.20 herein before but for 63 Amps
S&F MCB of SPN of rating 63 Amps
S&F MCB of rating 240 Volts, SPN 32 Amps C series
S&F MCB of Single pole of rating 6 to 32 Amps C curve including taking down the old one.
Taking down AC box any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F for modular 32 Amp motor starter AC switch with two module one piece including indication both red and green complete all as directed
Taking down Meter box any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F for meter board box made out of 2mm thick MS sheet with suitable angle iron supports of suitable size to accommodate 06 Nos meter and embedded in walls with proper fixing arrangement including painting with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as directed
S&F for meter board box made out of 2mm thick MS sheet with suitable angle iron supports of suitable size to accommodate 04 Nos meter and embedded in walls with proper fixing arrangement including painting with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as directed
S&F for meter board box made out of 2mm thick MS sheet with suitable angle iron supports of suitable size to accommodate 01 Nos meter and embedded in walls with proper fixing arrangement including painting with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as directed
S&F for PVC flexible hose pipe 25 mm including clamp and suitable for wiring complete all as directed
Taking down old serviceable existing electric meters and keep in safe custody inclduing refixing in same location/Quarters all as specified and dircted
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion, complete all as per Electrical plate No.03 and as directed by Engr-in-charge Note : the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 in foundation. RCC 1:2:4 type B-1 in cover slab reinforced with 8 mm dia CTD bars @ 150mm C/C both ways, funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble of dia 20mm Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
S & F for open slot PVC cable trunking width 40mm, depth 80mm complete and fixing on wall and roof including all accessory complete all as specified and directed.
S & F for open slot PVC cable trunking width 60mm, depth 80mm complete and fixing on wall and roof including all accessory complete all as specified and directed.
RK ENTERPRISES
PSK Enterprises
M/s.Sai Agency
G.L.THIRUMALAI NAIDU AND COMPANY
D Subramani and Sons
BKR Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .