Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Accepted. Being the L1 bidder. | |
| 2 | L2₹33.4 L+₹3.8 L (12.7%)Rejected-AOC 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | L2 | Rejected-AOC Rejected as not being the lowest bidder. | |
| 3 | L3₹39.1 L+₹9.5 L (31.9%)Rejected-AOC | L3 | Rejected-AOC Rejected as not being the lowest bidder. |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
31 Mar 2025, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
REPAIR/ REPLACEMENT OF PLUMBING, SUNKEN REPAIRS, SANITARY FITTINGS, WATER PROOFING, PLASTERING, REPAIRS TO LEAKAGE SEEPAGE AREA, REPAIRS TO JOINERY AND OTHER CONNECTED ITEMS OF CERTAIN BUILDING AT NCHC POWAI AND STREET LIGHTS AND LT CABLE AND MAINT O
2025_MES_697838_1
8394/B
Open Tender
Civil Works
Item Rate
270 days
POWAI, HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹80,000
Yes
26 Jul 2025
14 Feb 2025
1 Apr 2025
14 Feb 2025
31 Mar 2025
12 Mar 2025
15 Feb 2025 - 25 Feb 2025
Amount
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
S&F 25mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
All as per item No.03 above but 20 mm bore completed all as specifiec and directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed Make : Cera, Hindware, Parryware or tecno commercial equivalent.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed Make : Cera, Hindware, Parryware or tecno commercial equivalent.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed Make : Cera, Hindware, Parryware or tecno commercial equivalent.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed. Make - Parryware, Prayag, Commander.
S&F in repair for CP concealed stop cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make - Prayag, Polytuf, Jaquer, Sieko or Tecno Commercial equivalent.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make - Prayag, Polytuff.
S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed. Make - Prayag, Polytuff, Jaquer, Sieko or Tecno Commercial equivalent.
S&F in repairs brass Chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type. Make -Jaqur,Prayag polymers Pvt Ltd or equivalent. Make - Prayag, Jaquar, Marc, Jaquer, Sieko or Tecno Commercial equivalent.
S&F in repair CP pillar taps 15mm bore., cast copper alloy, chromium plated fancy type complete all as specified and directed. Make - Prayag, Polytuff, Jaquer, Sieko or Tecno Commercial equivalent.
S&F in repair stainless steel grating in ground shape 100mm dia complete all as specified and directed.
All as per item No.14 above but with hole complete all as specified and directed.
S&Fin repair plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete all as specified and directed. Make : Parryware, Cera, Prayag.
S&F stainless steel kitchen plate rack size 900x600mm etc complete all as specified and directed. Make:Nirali, Bule star, Prayag polymers Pvt Ltd or equivalent
S&F stainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm including supply and fixing bib tap CP with long body screwed for iron pipe complete all as specified and directed. Make : Nirali, Bule star or Tecno Commercial equivalent.
S&F in repair low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
S&F in repairs chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc complete all as specified and directed. Make:Prayag polymers Pvt Ltd or Tecno Commercial equivalent
S&F in repair SS soap dish complete all as specified and directed by Engineer-in-Charge.
S&F in repair SS Toilet paper holder complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP Health faucet with 1 mtr tube & hook complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP corner glass with brass bracket screws etc complete all as specified and directed.
S&F in repair CP glass shelf of size 450x150mm with grill and brass bracket screws etc complete all as specified and directed.
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L providing cement concrete type B0, 1:2:4 (12.5mm graded aggregate) 30mm thick as in flooring all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tiles and rubbish off the premises etcand removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in vertical surfaces such as skirtings, dados etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for vetrified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for vetrified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in walls skirting etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc . Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per Manufacture's instructions.Complete. Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any . Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed. Note: Water proofing compound will be measured & paid seperately.
M&L for 10 mm thick cement plaster in CM (1:3) using water proofing compound @ 3% by weight of cement complete all as specified and directed BY Engr-in-charge ( Note : water proofing compound will be measured and paid seperately)
M&L for APPLICATION OF 7 LAYER OF WATERPROOFING SYSTEM ON LEAKING ROOF BY THOROUGH SURFACE PREPARATION, OPENING AND FILLING OF CRACKS, APPLICATION OF ABSORPTION COAT OF THERMACOOL WP51, APPLICATION OF SANDWICH COAT OF ELASTOMERIC (THERMACOOL WP51 + CEMENT) WATERPROOFING LAYER WITH 80 GSM NON WOVEN FIBRE MESH, APPLICATION OF 3 RD COAT OF ELASTOMERIC (THERMACOOL WP51 + CEMENT) WATERPROOFING LAYER AND TOPCOATED WITH TWO COATS OF THERMACOOL 0.3C ELASTOMERIC, WATERPROOFING SOLAR IR HEAT REFLECTIVE COATING HAVING A MIN. SERVICE LIFE OF 10 YEARS.complete all as specified and directed.
Supply and Application of 4 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete WALL surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min. 50% solids, filling and sealing the cracks, then over coating with 2 Coats of NEEWP + Cement mixture as waterproofing coat having +450% Elongation followed by curing and then top-coated with 1 protective coat of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 100 - 120 microns using brush, roller, airless spray gun as applicable. The product should be certified by NABL Approved Lab and application is to be done by company approved applicator only"
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles.complete all as specifed and directed
M&L for brick work with sub class B old size bricks and of class designation 35 (Minimum compressive strength 35 Kg/Sqcm) , straight or curved on plan exc. 6metre mean radius, built in cement mortar 1:6, complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone wall surface including raking out joints, hacking for key, scrubbing down with water and removing debris outside MD land etc complete all as specified and directed.
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces in patches and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 as in ceiling in patches finishing even and fair etc complete all as specified and directed by EIC.
M&L for 15mm thick rendering in CM 1:4 on surface of wall in patches mixed with water proofing compound and shall be scored to provide key for rough finishing coat. including necessary scaffoldings etc complete all as specified and directed Note:- WPC shall be measured and paid seperately.
Supply only integral water proofing compound.
M&L chipping, removing carefully concrete surface by low impact hamer/bracker without damaging the structure incl preparation of old surfaces of reinforcement bars as per manufacturer's instruction and disposal of debris out side MOD land and applying anticorrosive protective coating for steel reinforcement surfaces and allpying epoxy bond coat of approved make over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new mortar, by brush application and building up the profile of structural members by using polymer modified mortar of approved make upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over coat of alkali resistant primer with roller etc complete all as specified and directed.
M&L for for preparation of new plastered surfaces on walls, chajjas and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of primer in approved shade and as per manufactur's instructions complete all as specified and as directed.
M&L for preparation new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer compelte all as specified and directed by Engineer-in-Charge.
M & L for preparation of old decorated surfaces of ceiling by brooming down or steel wire brushing scrapping down smoke, soot ,moulds, moss and efflorecent salts and treating oil and gresy spots and thereafter applying one coat of oil bound distemper with roller complete all as specified and directed
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying with roller one coat of oil bound distemper complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper including application of wall care putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old acrylic surfaces of walls/ceiling including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots, washing down with water, filling of cracks with crack filler of approved make and applying two coat of 100% antifungal acrylic paint of approved shade over a coat of acrylic primer including necessary scaffolding work etc complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
Dismantling Asbestos cement/galvatume aluminium zinc ( corrugated semicorrugated, etc) sheets in roof coverings etc complete all as specified and directed.
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering/clading to wall/Chajjas upto 4 story bldg, fixed with self taping screws as specified.
S & F Steel work in joist,channel,angle,or tee sections, fixed independently, without connecting plates, etc. including tubular poles/purlin/rafter special shaped washer etc. complete using Fe 410-W(Gde-E-250 quality-A) work upto 4 story bldg complete as specified and directed.
M&L for preparation for two coats of synthetic enamel paint over on new steel /iron surfaces over one coat of red oxide primer complete all as specified.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames), exc 1.50 sqm but not exc 4.0 sqm each complete as directed
Taking down shutters of any description, exc 1 Sqm and n.exc 2 sqm each complete all as specified and directed
Taking down and refixing in the same opening shutters of any description exceeding 1 Sq.m but not exceeding 2 Sq.m each complete all as specified and directed.
M&L for IInd class Hard wood (Sal) plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joint complete all as specified and directed.
S & F,IInd class hardwood 35mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
S & F 2nd class hardwood, glazed and skelton shutter, 35mm thick, open rebated and prepared to receive glass, gauze etc, divided into square with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plane, chamfered or rounded, fitted with cut and mitered bead for securing glass, gauze etc, size of member of shutters as specified in SSR Part -I, section 8, class 8.24(a) (Door shutter), supplied and fitted to chowkats all as specified and directed.
M&L , in repairs, IInd class Hard wood plain fillets squares, rectangular or triangular in section, wrought, secured with screws, sectional area exc 13 Sqcm and not exc 25 Sqcm complete all as specified and directed.
M&L for 19mm thick block boards, grade - I quality, exterior grade, decorative type with decorative face veneer on both sides with external teak wood lipping, 6mm thick alround fixed with screws to timber frame work for cuboard self or shutters etc, complete all as specified and directed..
S&F for Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per spcification & drawing etc, complete all as specified and as directed.
S&F for Factory made solid PVC Moulded door shutter , 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm th. Moulded PVC sheet on the front face & 2mm plain coour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS etc, complete all as specified and as directed.
M&L for 20 to 25mm thick machine cut and machine polished cudappa stone slab for kitchen plateform jointed and set in CM 1:3 and fixed including rounding to edge of stone slabs one side edge etc complete all as specified and as directed
M&L for 18-20mm thick granite(of any type) work table rubbed and polished as in jambs, pillars, door and windows-cill, cooking platform , jambs, wash basin platform and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting of oval shape for fixing of counter wash hand basin etc over and including 10mm thick rendering / screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed.
S&F machine cut and machine polished, green marble, 18-20mm thick on horizontal or vertical surface,as in window cills and jambs bedded, jointed and pointed with neat grey cement slurry and pointed with coloured or white cement with pigment to match over and including rendering coat of 10 mm thick in CM 1:4 all as specified and directed.
S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed. Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
Material and labour aluminium anodised grill with suitable aluminium anodised frame section manufactured by M/S Deco grill pattern DG-102 (7.5mm thick and aparture 50mm) in repair complete all as specified and directed.
Supply only 5.5 mm thick sheet glass, pin head type and glazing with oil putty in square not exceeding 0.5 Sqm in each pane etc complete all as specified and directed.
Supply only 5.5 mm thick glass ordinary quality in plain exc 0.50 Sqm each pane including rubber beading or gasket for aluminium section complete all as specified and directed.
Supply only 5.5 mm thick figured glass/pin headed type and glazing with oil putty in sq n exc 0.5 sqm in each pane, fixed in aluminium ventilator complete all as specified and directed.
Supply only for 6mm thick bakelite sheet prelaminated both side with decorative choice laminations for aluminium frame work with including rubber beading or gasket for aluminium section complete all as specified.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S&F bands, straps supports or stay heavy for large gates, hook and pintle hinges clamps, hold fasts, wall tiles, hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for providing cement concrete type C1, 1:3:6, using 20mm graded stone aggregate as in bed block for hold fast, coping etc including necessary form work complete all as specified and directed.
S&F in repair stainless steel heavy duty continuous piano hinges for cupboar/cabinet etc complete all as specified and directed by Engineer-in-Charge.
S & F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring of length 140mm fixed in floor etc complete all as specified and directed.
S &F, in repairs, aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with in wooden windows, doors etc,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
Supply and fix aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolt of extruded section of size 250 mm fixed at any position all as specified and directed.
S&F in stainless steel butt hinges, 100mm, medium weight complete all as specified and directed
S&F in extruded aluminium alloy handles, fabricated type of size 150mm in any position complete all as specified and directed.
S&F in aluminium, anodised, barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
S&F in repair for 20mm dia fancy type chromium plated curtain rods with fixing fancy brackets, brass screws etc complete all as specified and directed
M & L for anti termite treatment providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified and directed by Engr-in-Charge.
M & L for anti termite treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed
M & L for anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete and removing the retreived debris out side MD land, complete all as specified and directed.
M&L Providing 2 to 2.5mm thick FRP Chajja of approved Pattern/shape/size( with sides & front drop etc), colour/patterm as of mangalore clay tile (the FRP chajjas shall be moulded in gel coat finish, the thickness shall be 4mm and back patti to be additionally reinforced with core matt, all resins and pigment shall be fully weatherable and UV established, core malt shall be used with GSM for extra thickness,necessary FRP covered metal), chajja shall be fixed in position with and including 8mm dia and 125mm long split fastener bolts spaced not more 45cm C/C and also filling the gaps with polysulphide sealant including necessary scaffolding/erection of working platform etc, complete all as specified and directed. Make- M/s Tital Enterprises or Advance FRP or Sintex.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for exposing getting out GI/CI pipes in Soft/loose soil all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming lin layers not exceeding 25 cm after the pipes have been laid all as specified and directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Taking up / down old unserviceable chocked rusted GI pipe & fittings complete for following bore of pipes :- (a) 50 mm dia bore
Supply and laying in trenches /fixing to wall / ceiling or floor, jointing, GI tubing, medium grade including all fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc complete all as specified and directed for the bore of pipe 50mm dia.
All as per item No.104 above but for the pipe dia 25mm
All as per item No.104 above but for the pipe dia 20mm
Supply and fix in repairs Non Return valve Cast iron body threaded type both ends suitable for 50mm bore GI delivery pipe connection complete all as specified and directed.
Supply and fix in repairs Foot valve Brass body flanged suitable for 50mm bore GI pipe connection complete all as specified and directed.
Supply and fix in repairs gun metal gate valve with iron wheel head, threaded both ends of size 50 mm duly ISI mark complete all as specified and directed.
Supply and fix in repairs gun metal gate valve with iron wheel head, threaded both ends of size 25 mm duly ISI mark complete all as specified and directed.
Supply and fix in repairs gun metal gate valve with iron wheel head, threaded both ends of size 20 mm duly ISI mark complete all as specified and directed.
M & L for disconnect/reconnect the electrical connection and uncoupling from pump and dismantling from common base frame and opening of stater and rotor removing the burnt wiring and rewinding of the induction motor with suitable size of super enameled copper winding wire of existing gauge and insulating materials and sleeves, varnishing the winding, drying, replacement of terminal plate re assembled/installed in common base frame testing the motor with existing pump set of 5 HP Capacity. including transportation to workshop & back all as directed by Engr -in - charge :-
Material and labour for replacement of unserviceable din rail mounted Elecronic Timer for Star delta starter, with adjustable Time range 9 to 30 sec,1-Phase, 230 V operated including electrical connection all as specified and directed by Engr-in- Charge Make : Selec/GIC/Siemens
Material and labour for replacement of un serviceable over load relay suitable for 3 phase motor 5-15 HP motor size with ISI Approved including all electrical connection of the complete all as specified and as directed.Make : L&T / Siemens or tecno commercial equivalent.
Material and labour for replacement of un serviceable power contactor type ML 1.5 suitable for 5.0/7.5/ 10 HP pump set starter of water pump including all electrical connection of the following type complete all as specified and as directed.
Material and labour for replacement of un serviceable Single phase preventor 230v 50 hz supply operated for phase protection of 3 phase water pump including all electrical connection of the following type complete all as specified and as directed.
Cleaning of underground water sump by draining / pumping of water removing / sludge from bottom removing algae and other growth from wall/floor/ roofs by high pressure cleaning method with rotary jets with approved detergent fubbing with vaccum cleaner sucking out all dirty water disinfecting the sump with chemical treatment (Chemical approved by FOA/WHO to make the sump totally clean bacteria free including painting MS steps manhole covers and suction pipe with synthetic enamel paint of 10000 gallons capacityEach at Sea Eagle-1 pump house and MAP pump House at INS Hamla
Supply and laying DWC(Double Wall Corrugate) pipes of pressure rating 6 Kg/Cm sq of size 50 mm dia IS: 16205(Part 24):2018 laid in trenches complete all as specified and directed.
Supply and laying DWC(Double Wall Corrugate)HDPE pipes of pressure rating 6 Kg/Cm sq of size 40 mm outer dia IS: 16205(Part 24):2018 laid in trenches complete all as specified and directed.
Supply and laying GI pipe 50 mm dia light grade for the protection of the cable passing through road crossing, etc.
Disconnecting the existing LT UG cable ( Cable sizes between 3.5 Core x 25 sqmm To 3.5 Core x 95 sqmm of any length) Terminals from both ends of Panel by injecting the Surge voltage(Hipot Testing) and finding the fault by Cable fault reflectometer Machine and make temporary joint with suitable ferruls and lugs and laying back the cable in trench and refilling the excavated soil back complete all as specified and directed by Engineer in charge.
Material and labour for LT 1100 volts grade cable straight through joint at the cable in ground or End termination Joint at panel Connection with heat shrinkable type for underground LT cable 1100 volt complete all as specified and directed by Engineer in charge for the cable size 4Cx16 Sqmm to 4C X 70 Sqmm.
Supply and fix in replacement of Unserviceable MCCB 4 pole 63-100 Amps 415Volt 50Hz breaking capacity 25KA adjustable with suitable size Lugs and Screws Fitted in existing Indoor/Outdoor LT Panel Including complete all as specified and directed by the Engineer-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of galvanised iron steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe of suitable size including testing on completion all as specified and directed.
Taking down Old U/S LT UG Cable of any size complete all as specified and dicrected.
Supply and laying in repairs cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with Multi stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge for the following sizes including taking down existing u/s LT cable. (a) 50 Sqmm 3.5 Core.
Supply and fix in replacement 40mm dia GI Garden pole Light grade Upto 4 mtrs long for existing garden light pole for replacing unserviceable poles including dimantling existing GI Pole complete all as specified and directed.
Material and labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) for foundation, filling and mass concrete complete all as specified and directed.
Supply and fixing in replacement of U/S post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in replacement of U/S LED Bollard light 8-12 watt warm white colour 230 watt volts AC outdoor type with for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in replacement pole mounting box FRP type IP 55 Protection of size 250mm x 200mm x 100 mm, single phase with locking arrangements, including necessary nut, bolt and clamps of the flat iron of size 20mm x 3 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'B' series with proper fixing arrangements on pole complete all as specified and directed. Make: National/ Sintex or tecno commercial equivalent.
Supply and laying in replacement of cable LT XLPE 4 core 16 sqmm insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with Multi stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge.
All as per item No.133 above but for cable size 2 core 10 sqmm complete all as specified and directed.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and drawing through the pole for making connections to the Street light/Flood Light fittings,three core,PVC insulated and sheated, Heavy duty,1100 volts grade,multistranded copper conductor(FRLS) Flexible cable 3C x 1.5 sqmm, complete all as specified and directed
Material and labour for Repairs to replacement of Unserviceable Street Lights Digital Timer switch single phase 230V Operated 50 hz frequency with inbuilt chargeble battery backup upto minimum 24 hrs complete all as specified and directed.
Material and labour for replacement of un serviceable 3 pole 415 Volts power contactors Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1,Current Rating up to 40 Amps for Street Light Timer switches complete all as specified and as directed
Taking down existing LT/UG cable from existing trench by manual excavation and finding the fault and make temporary joint with suitable ferruls and lugs and laying back the cable in trench and refilling the excavated soil back cable size of upto 70 sqmm 3.5/4 core complete all as specified and directed. Note : For above item any extra cable required will be measure and paid seperately under Concerned items.
Taking down existing unserviceable burnt out end termination of LT/UG cable from LT panel, pole box etc and taking out loop by excavation and repairs the cable by providing with new aluminium/Copper any type lugs and connecting up by replacing UN-serviceable bolts nuts etc complete all as specified and directed of cable sizes 35 to 95 Sqmm 3.5 Core
Deduct Credit for Demolished/ Dismantled material Rs. (-) 58,620.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
the bhimani group of companies (BID ID -3274356)
Shah Enterprises (BID ID -3261657)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .