Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L One₹47.7 LRejected-Finance 10 10 B N SAHA ROAD CHIRKUNDA DHANBAD JHARKHAND | DHANBAD | JHARKHAND | 818142 | L One | Rejected-Finance Due to tender Cancel | |
| 2 | L two₹53.7 LRejected-Finance NOT AVAILABLE | L two | Rejected-Finance Due to tender Cancel | |
| 3 | L three₹60.8 LRejected-Finance 12 GHAR PARIHAR BBHAWAN BASTEPUR NEAR BY MOTHER TEERESA SCHOOL RAEBARELI UTTAR PRADESH 229001 | RAE BARELI | UTTAR PRADESH | 229001 | L three | Rejected-Finance Due to tender Cancel | |
| 4 | L Four₹64.0 LRejected-Finance DAYAL NAGAR PISKA MORE RANCHI 834 005 JHARKHAND | RANCHI | JHARKHAND | 834005 | L Four | Rejected-Finance Due to tender Cancel |
Tender Value
₹62.1 L
EMD Value
₹1.2 L
Closing Date
19 Feb 2024, 5:00 pmClosed
Executive Engineer
RURAL DEVELOPMENT SPECIAL DIVISION DUMKA
Construction of Integrated Public Health Laboratory IPHL in Sadar Hospital, Dumka
2024_RDSPL_82940_1
RDSD/DMK/PMABHIM/46/2023-24/RE
Open Tender
Civil Works
Percentage
180 days
DUMKA
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.2 L
4 Oct 2024
12 Feb 2024
21 Feb 2024
12 Feb 2024
19 Feb 2024
12 Feb 2024
Amount
Supply, installation, testing and commissioning of modular OT ceiling panels with insulated prefabricated puff Panels. The OT ceiling shall be constructed using GI puff panels having 0.8 mm thick GI sheets on both sides. These panels should have been produced in a double band laminator, in which two continuously moving belts carrying 120 GSM galvanized steel sheets of 0.80 mm thickness are firmly bonded together by sprayed -in insulating foam, which hardens during the process. The core consists of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3. The thickness of Puff shall be minimum 40 mm. The sheet panel shall be ofindigenous reputed make and be provided with manufactures test certificate. The puff panel shall be fixed to the floor with bottom track of 1.5 mm thick steel U channel section having min size of 50mm X 50mm. The bottom shall be fixed in the floor of the OT with 10mm thicknessand min. 60 mm long SS fasteners which shall be fully threaded and power drilled. The Panels of walls and ceiling shall be tied together by suitable SS coving. The individual panels of wall and ceiling shall be tied together by suitable SS coving. The individual wall panels shall be welded together bySS. All joints shall be filled with metal filler and shall be sand casted on site till smooth finish is obtained. Wall & panel joints shall not be visible after the final wall coating is applied. The gap between the masonry wall surfaces and the panel of the theatre shall be sufficient for the flush mounting of equipment’s. This gap shall be provided to accommodate the equipment at a latter date and to enable services, pipes conduits etc, to be run within the gap. All wall-mounted equipment shall be flush mounted and sealed in operation theatre All the sharp edges and corners shall be in radius to avoid bacterial contamination. The wall panel design shall be such that it enables the installation and supports all equipment’s. Provision of openings required for the installations shall not affect rigidity and strength of the panel. Access boxes shall be fitted to the rear of all wall mounted equipment to enable maintenance to be carried out from outside the operation theatre. Product should have warranty of at least 10 years. The work should be executed as per thedirections of Engineer–in-Charge.
Providing and establishing anti-bacterial & anti fungicidal sterile coating of liquid plastic paint on GI Puff/SS panel of modular OT. The paint should be seamless, easy to clean, should have vapor permeability which allows substratemoisture to escape and protects against growth of bacteria, mound and yeasts, moisture resistance, freeze / thaw resistance. Anti-bacterial paint’ anti microbial quality should remain active throughout the life of the product. Vapors permeable structure should allow damp substratesto dry out without causing blistering. It should tolerate cleaning with hospital chemical agents. Filling of all joints and cavities should be with metallic epoxy filler and sand casted flush to provide a joint-lessfinish. This should include all fittings, accessories, hardware, support structures, etc. required for installation. Anti-bacterial andanti-fungus sterile coating shall be applied on the finished walls & ceiling with at least 2-3 coats to achieve a thickness of minimum 200 micron. Before application of sterile wall coating an appropriate primer shall be applied. The primer shall be supplied along with the paint and should be of the same make as that of paint. and shall be applied prior to coating of anti-bacterial & anti- fungus ste before screed over it. Waterproofing B shall be applied to achieve a thickness of 200 microns. Sterile coating and primer shall be applied on the surface by air-less spray gun. Sterile coating shall withstand against application of commonly used cleaners in the operation rooms and shall withstand against regular steam cleaning. Product should have warranty of at least10 years. The work should be executed as per thedirections of Engineer–in-Charge.
Supplying, fixing installation, testing and commissioning of scrub sink with the following specifications:- Compact surgical scrub sink should be designed for use in OT complex for pre procedural scrub up. (Double sink combination size 1600 mm X 450mm X 1650 mm back height & 1200 mm and front heightas suitable) • Each fixture should be fabricated from heavy gaugetype 304 stainless steel (minimum thickness 1.5mm) and should be seamless welded construction, polished to a satin finish • The scrubsink should be provided with a front access panel which should be easily removed for access to the water controlled valve, waste connections,stoppers and strainers.• Hands free operation should include infra-red sensors with programmable adjustment.• Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature.• Timing should be adjustable to meet individual application requirements.• Provided with infrared sensors, thermostatic control taps with feel safe temperature controls with foam flow attachments and provide with Betadine dispensers .• All units should have reduced anti- splash fronts. • Knee/foot operated switch should be provided additionally. The work should be executed as per the directions of Engineer–in-Charge.
Providing and establishing the view windows of size 1.00 m x1.00 m. It should be provided with each operation theatre and should have double isolated fixed glazing with not less than 5 mm thick toughened glass on both sides with 12 mm air gap. Window frame should be of powdered coated aluminum of approved shape flush mounted with wall paneling should have horizontal venetian blinds of powder coatedaluminum strips of vista level or equivalent of approved shade including necessary accessories. Window (Size: - 1000 mm x 1000 mm) with both side glass with blinds sandwiched in between.The blinds should be openable from inside the O.T. The work should be executed as per the directions of Engineer–in-Charge.
Supply and installation of storage unit of SS 304 of reputed make and having size 1665 x 865 x 350 mm and having two or more glass shelves of toughened glass 10 mm thick, supported with D type bracket (SS 304 grade) with 10 mm thickness and rubber gasket of 2mm and mountedflush on wall. The work should be executed asper the directions of Engineer–in-Charge.
Supply & Installation of writing unit/white board of size 900/600 mm having 1.60 mm thick white laminate board top, bonded to a 40 mm high density fiber board sheet for additional rigidity. The unit should open to create a wall mounted writing surface within the operating room. The work should be executed as per the direction of Engineer-in-Charge.
A hatch of size 600mm x 600mm manufactured by stainless steel grade SS 304, should beprovided in the operation theatre as specified in the scope of the work to remove waste materials from the operation theatre to dirty linen area (or dirty corridor) just adjacent to operation theatre. Each hatch box should be electronically operated.The hatch box should be designed in such a way that only one door should be opened at a time.The UV light should be so installed that it is kept on while both the doors are closed, this UV light has to be automatically turned off in case of opening of either of the doors. There should be indicators on both sides of the OT so that the dooropen/close status can be monitored from both ends. Hatch Box should be installed as per manufacturer’s instructions manual. The work should be executed as per the direction of Engineer-in-Charge.
Surface preparation:- Providing and cleaning all floor surface to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface, etc and complete as per manufacturer's specification. Note: All new substrate shall be allowed to cure and dry completely according to standard practice. The substrate shall be of M20 grade with VDF / IPS finish. The base should be hard & strong (minimum tensile strength of 1.5 N/Sqmm). The base should be free from random cracking & potholes. Flatness of the base should be checked for level to ensure that the specified thickness of treatment can be applied over the whole area. All the expansion & movement joints should be properly cut and maintained for terminations. The preferred method of surface preparation is by mechanical means. The substrate shall have moisture content of less than 5%. This product shall not be applied on the floors that are known to have rising moisture or have relative humidity of greater that 75% at the time application. All application shall be not carried out where temperature less than 10 Deg C or above 40 Deg C Priming:- Providing and applying Apcoflor HFP 120/ Apcoflor HFP 130, solvent free epoxy primer in two coats using a brush or short / medium pile roller at a time gap of 8 hrs by ensuring a uniform coating is achieved and compensated the differences in surface porosity, allowing second coat to dry for 24 Hrs, etc and complete as per manufacturer's specification. Epoxy screed:- Providing and installing, Apcoflor LSC3 XL high performance, epoxy resin flooring system by mixing all 3 components using heavy duty slow speed drilling machine fixed with mixing paddle, pouring of mixed material on the primed surface and spreading it using suitable trowel / pin rake trowel at 2mm thickness, gently rolling the spike roller to remove the entrapped air, etc and complete as per manufacturer's specification. Top Coat :Providing and installing, Apcoflor SL1 TC, high performance, epoxy resin flooring system by mixing all components including Pigment, using heavy duty slow speed drilling Note: 1) Prices are ex of tax 2) Work shall commence up on receiving 50% advance 3) Cement, sand, aggregate, electricity, water are in client's scope machine fixed with mixing paddle, pouring of mixed material on the primed surface and spreading it using suitable trowel at 1mm thickness, gently rolling the surface of Apcoflor SL1 TC using spike roller to remove the entrapped air, etc and complete as per manufacturer's specification.
WIPL Fan-Filter-Unit, Automation Grade: Manual, 220v
Supply & Return Diffuser
AHU- Air Handling Unit With Ducting
Floor Mounted Exhaust Air Handling Unit
High Back Revolving Chair
TABLE - SIZE- 1365X680X735MM
HOSPITAL SHEET BED - Overall Sizes: (L)2268 mm X ( W)922 mm X (H) 610 mm
Labour cess @ 1%
Bidder Name
Amount
M/S GUPTA CONSTRUCTION (GSTN-20AJHPG7406J1Z1) BID ID -583293
RAVINDRA CHANDRA SINGH (GSTN-20DVMPS7803B1ZQ) BID ID -583688
SHANKAR AND COMPANY (GSTN-20AARFS9963P1Z6) BID ID -583832
ASHOK KUMAR SINGH(GSTN-NA)--583506
M/S GUPTA CONSTRUCTION
ASHOK KUMAR SINGH
SHANKAR AND COMPANY
RAVINDRA CHANDRA SINGH
ASHOK KUMAR SINGH
SHANKAR AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .