Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAdmitted-Finance | ₹19.5 L | L1 | Admitted-Finance |
| 2 | L2₹19.7 LAdmitted-Finance | ₹19.7 L | L2 | Admitted-Finance |
| 3 | L3₹19.8 LAdmitted-Finance VILL P O AMJAI BARDHAMAN BARDHAMAN 713203 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713203 | ₹19.8 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | K R ENTERPRISE L1 | N.K. ENTERPRISE L2 | F.R. ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00Part A: Transportation, installation, necessary fabrication, commissioning & trial run of one no. 1000mm width, 2×150kW, 6.6kV drive belt conveyor along 23D from 59L to 54L in R-VII seam | ||||||
| 1.01 | Loading, transportation and unloading of one breaker (6.6kV/200A), starter (6.6kV/2×150kW), LS unit to 58L/23D/R-VII with help of haulages & 20 mtr manually | 1 | WORK | 26,350 ₹26,350 | 26,613.5 ₹26,613.50 | 26,746.57 ₹26,746.57 |
| 1.02 | Laying-hanging of 100 mtr 6.6kV grade 70 sq.mm. PVC DWA cable from VCB to 58L/23D starter manually | 1 | WORK | 38,650 ₹38,650 | 39,036.5 ₹39,036.50 | 39,231.68 ₹39,231.68 |
| 1.03 | Transportation of the 1000mm width, 2×150kW, 6.6kV drive head unit complete with loop take-up structure, look-out arrangement and installation at 58L/23D (R-VII) with necessary fabrication | 1 | WORK | 9,09,934 ₹9.1 L | 9,19,033.34 ₹9.2 L | 9,23,628.51 ₹9.2 L |
| 1.04 | Transportation of 370 mtr 1000mm width PVC belting from dismantled site to 23D belt installation site (23D/58L) with help of haulages & 60 mtr manually | 1 | WORK | 65,750 ₹65,750 | 66,407.5 ₹66,407.50 | 66,739.54 ₹66,739.54 |
| 1.05 | Laying, lapping, jointing & tensioning of this 370 mtr 1000mm width PVC belting in proposed 23D belt | 1 | WORK | 35,150 ₹35,150 | 35,501.5 ₹35,501.50 | 35,679.01 ₹35,679.01 |
| 1.06 | Transportation of 500 mtr belt sequence cable, then laying-placing them from previous belt starter to 23D belt starter placed at 58L/23D in R-VII seam | 1 | WORK | 16,320 ₹16,320 | 16,483.2 ₹16,483.20 | 16,565.62 ₹16,565.62 |
| 1.07 | Testing, trial run, alignment & commissioning of 59L belt conveyor from 59L/23D to 54L/23D in R-VII seam | 1 | WORK | 14,350 ₹14,350 | 14,493.5 ₹14,493.50 | 14,565.97 ₹14,565.97 |
| 1.08 | Supply of DA cylinder (@ 6.2 cu.mtr/cyl.) | 2 | NOS | 3,450 ₹6,900 | 3,484.5 ₹6,969 | 3,501.92 ₹7,003.85 |
| 1.09 | Supply of Oxygen cylinder (@ 7.1 cu.mtr/cyl.) | 6 | NOS | 400 ₹2,400 | 404 ₹2,424 | 406.02 ₹2,436.12 |
Tender Value
₹19.5 L
EMD Value
₹24,400
Closing Date
11 Feb 2026, 11:00 amClosed
AREA ENGINEER ENM
Office of the General Manager, Jhanjra Area, ECL
Transportation, installation, necessary fabrication, commissioning and trial run of one no. 1000mm width, 2X150kW, 6.6kV, drive belt conveyor along 23D from 59L to 54L in R-VII seam, Panel 10 at 3n4 Incline, J.P.Colly
2026_ECL_351930_1
ECL/GM/JNR/EnM/A2/25-26/115 dated 27.01.2026
Open Tender
Miscellaneous Works
21 days
JHANJRA UG
Please refer Tender documents.
4 documents required · 4 mandatory
₹24,400
17 Feb 2026
30 Jan 2026
12 Feb 2026
30 Jan 2026
11 Feb 2026
31 Jan 2026
30 Jan 2026 - 6 Feb 2026
Part A: Transportation, installation, necessary fabrication, commissioning & trial run of one no. 1000mm width, 2×150kW, 6.6kV drive belt conveyor along 23D from 59L to 54L in R-VII seam
Loading, transportation and unloading of one breaker (6.6kV/200A), starter (6.6kV/2×150kW), LS unit to 58L/23D/R-VII with help of haulages & 20 mtr manually
Laying-hanging of 100 mtr 6.6kV grade 70 sq.mm. PVC DWA cable from VCB to 58L/23D starter manually
Transportation of the 1000mm width, 2×150kW, 6.6kV drive head unit complete with loop take-up structure, look-out arrangement and installation at 58L/23D (R-VII) with necessary fabrication
Transportation of 370 mtr 1000mm width PVC belting from dismantled site to 23D belt installation site (23D/58L) with help of haulages & 60 mtr manually
Laying, lapping, jointing & tensioning of this 370 mtr 1000mm width PVC belting in proposed 23D belt
Transportation of 500 mtr belt sequence cable, then laying-placing them from previous belt starter to 23D belt starter placed at 58L/23D in R-VII seam
Testing, trial run, alignment & commissioning of 59L belt conveyor from 59L/23D to 54L/23D in R-VII seam
Supply of DA cylinder (@ 6.2 cu.mtr/cyl.)
Supply of Oxygen cylinder (@ 7.1 cu.mtr/cyl.)
Supply of 5T Turnbuckle 89 G 63-88
Supply of M.S. Nut & Bolt 5/8"×2"
Part B. Civil foundation work
Civil foundation works for installation of 2×150kW, 6.6kV, 1000mm wide belt conveyor drive head, discharge unit, loop take-up unit and platform for ACB, starter for proposed 23D belt conveyor of 3 & 4 incline, JPC
Part C: Roof heightening work
Roof heightening by drilling, blasting in stone, cleaning, roof bolting including cost of drill rod, drill bit for installation of proposed 23D belt conveyor in R-VII seam of 3 & 4 incline under JPC (with GST)
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.49 MB
Tendernotice_2.pdf
PDF • 1.20 MB
BOQ_364711.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid