| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹3.1 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹3.5 Cr+₹39.0 L (12.6%)Rejected-Finance | ₹3.5 Cr+₹39.0 L (12.6%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹3.8 Cr+₹66.4 L (21.5%)Rejected-Finance | ₹3.8 Cr+₹66.4 L (21.5%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹4.2 Cr+₹1.2 Cr (37.3%)Rejected-Finance | ₹4.2 Cr+₹1.2 Cr (37.3%) | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹2.8 Cr
EMD Value
₹3.6 L
Closing Date
3 Nov 2022, 6:00 pmClosed
CWE
HQ CWE Dhar Road
PROVN OF OFFICE OF CWE DHAR ROAD AT UDHAMPUR
2022_MES_534979_1
8233/CWE/DR
Open Tender
Civil Works
Lump-sum
365 days
Udhampur
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
GE (P) CH Udhampur
₹3.6 L
2 Dec 2022
1 Jul 2022
5 Nov 2022
1 Jul 2022
3 Nov 2022
17 Oct 2022
Amount
Total Amount of Sch 'A' Part - I (BUILDING PORTION)
Total Amount of Sch 'A' Part - II (INTERNAL WATER SUPPLY)
Total Amount of Sch 'A' Part - III (INTERNAL ELECTRIC SUPPLY)
Total Amount of Sch 'A' Part - IV (EXTERNAL ELECTRIC SUPPLY)
Total Amount of Sch 'A' Part - V (WATER COOLER)
Total Amount of Sch 'A' Part - VI (DESERT COOLER)
Total Amount of Sch 'A' Part - VII (MS SPIRAL STAIR CASE)
Total Amount of Sch 'A' Part - VIII (ROAD/PATH/CULVERT)
Total Amount of Sch 'A' Part - IX (PLUMBING WORK)
Total Amount of Sch 'A' Part - X (EXTERNAL WATER SUPPLY)
Total Amount of Sch 'A' Part - XI (SHIFTING OF EXTERNAL WATER SUPPLY
Total Amount of Sch 'A' Part - XII (SEWAGE LINE)
Total Amount of Sch 'A' Part - XIII (AREA DRAINAGE)
Total Amount of Sch 'A' Part - XIV (COMPOUND WALL)
Total Amount of Sch 'A' Part - XV (STEEL GATE)
Total Amount of Sch 'A' Part - XVI (SHIFTING OF CHAIN)
Total Amount of Sch 'A' Part - XVII (SITE CLEARANCE)
Total Amount of Sch 'A' Part - XVIII (PROTECTIVE WORK)
Total Amount of Sch 'A' Part - XIX (DEMOLITION)
Total Amount of Sch 'A' Part - XX (SHIFTING OF EXTERNAL ELECTRIC SUPPLY)
Sch 'A' Part - XXI (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Supply & hanging (down rod as per ground requirement) Ceiling Fan complete with and all accessories 230 V SP 1200 mm sweep 50 watts or below double ball bearing, white colour with 03 blades 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE with squirrel cage induction motor complete all as specified and as directed. Note : Down rod will be provided as per ground requirements without any finincial effect.
Supply & hanging (down rod as per ground requirement) Ceiling Fan complete with and all accessories 230 V SP 1400 mm sweep 50 watts or below double ball bearing, white colour with 03 blades 50 Hz, Min air delivery 245 CFM with service value 6.00 BEE with squirrel cage induction motor complete all as specified and as directed. Note : Down rod will be provided as per ground requirements without any finincial effect.
S&F exhaust fan,made of sturdy Engineering plastic complete with louvers shutters, voltage 230 V, 50Hz, RPM 1200, Single phase, copper winding of sweep 300 mm all as specified.
S&F exhaust fan,made of sturdy Engineering plastic complete with louvers shutters, voltage 230 V, 50Hz, RPM 1200, Single phase, copper winding of sweep 250 mm all as specified.
20 W LED Tube (4ft) having minimum 1850 lumens with extruded engineering plastic housing, polycarbonate diffuser, G-13 polycarbonate end cover. > 102 lumen/ watt, lumen maintenance > 70% at 50,000 hrs, colour temperature of 5000-6000, >70 colour rendering. The driver must be integral APFC and constant current type having THD <20% and power factor >0.9 with reverse polarity protection and open circuit protection with suitable batten fitting all as specified and directed.
Supply and fix B Curve MCB single pole 240 volts any rating from 5 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables all as specified
Supply and fix B Curve MCB SPN 240 volts any rating from 32 to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables all as specified
S&F 30W IP66 LED Street light luminaire comprising of rectangular Die-Cast aluminium housing with weather proof gasket for lamp & driver campartment with system wattage of 30W+/-10%W. The LED make must be with 120 degree view angle, >120 lumen/watt, lumen maintenance > 70% at 50,000 hrs, colour temperature of 5000-6500,> 70 colour rendering and LM 80 test compliance. The driver must be integral APFC and constant current type having THD<15% abd power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection, protection against 5 KV high surges and comply to IEC 60598-1, IEC 61000-3-2,IEC 61547. The luminaire must have secondary optics with perfectly matched lens for batter light control including suitable size and length of GI bracket all as specified.
Metal box of size 75x75 mm on surface/ in recess with 3mm phenolic cover for mounting switch socket etc as required and complete all as specified and directed.
Telephone M.S. tag box with hinged cover having locking arrangement as per telephone deptt approval and having 10 pair tag etc. as reqd.
Supply and fixing CP brass two way angle valve, for 15mm bore dia pipes complete all as specified and as directed
Supply and fixing UPVC connection pipes 450mm long with 2 Nos. CP brass unions and washers suitable for 15 mm dia pipe, complete all as specified and as directed.
Supply and fixing 15mm bore CP brass long body, fancy type bib taps, weighting not less than 690 gms, with fancy knob screwed down, screwed for iron pipes or for brass ferrule complete all as specified and as directed.
Supply and fixing CP brass single lever wall mixer with spout for hot and cold bathing suitable for 15mm bore dia pipe complete all as specified and as directed.
supply and fixing CP brass single lever wash basin mixer with spout for hot and cold suitable for 15mm bore dia pipe complete all as specified and as directed
Steel tubular swaged poles complete with MS base plate 6mm thick of size 300mm x 300mm, finial taper plug, bolts, nuts, washers and screws (11 metres long) type 410 SP-55( 11.0 Mtr long) including drilling of holes or required size and nuts for fixing of cross arms, painting with a coat of red oxide zinc chrome primer and two coats of aluminium paint on exposed surfaces and two coats of back bituminous paint for portion embedded in concrete, painting five black/white bands at lower portion of pole each of 300 mm height at 300mm spacing, complete all as specified and as directed by Engr-in-Charge. Note Excavation, earth work and PCC shall be measured and paid separately.
Supplying and fixing the following in the existing sheet steel box including connections etc. as reqd.
RJ 11 Telephone socket
TV socket
2 pair, 0.51 mm PVC insulated, PVC sheathed annealed tinned copper conductor telephone wire drawing in existing conduit all as specified.
Supply and fixing LT Panel indoor type suitable for 3 phase, 415 volt, busbar 200 amps, 50 c/s, 4 strips aluminium busbar, wall mounted/Floor mounted vermin proof factory made fabricated out of 2 mm thick CRCA sheet steel, door fixed hinges and complete with MCcB's at Incoming & outgoings, locking arrangement, painted with two coats of synthetic enamel paint over one coat of red oxide primer and internal wiring, terminals of external cables, lugs, gland & conduits as required. (a) MCCB 4 pole 100 Amp 36 KA - 01 No. ( Incoming) (b) MCCB 3 pole 63 Amps 25 KA -03 Nos. (Outgoing-03 Nos for three floors) (c) MCB SPN 32 Amps 25 KA-01 Nos ( 01 for spare) Note:- (i) The panel shall be front and rear operatded with cable entry from the bottom with cable glands. The fault with standing capacity shall be 50 KA & earth bus shall be part of the LT panel. (ii) Fabrication of panel box to be done by CPRI approved manufacturer. (iii) Cost of earth work and construction of platform for panel, brick masonary in cement mortar 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (20mm thick crushed stone aggregate), deemed to be included in this item rate.
10 W LED Tube (2ft) having minimum 1850 lumens with extruded engineering plastic housing, polycarbonate diffuser, G-13 polycarbonate end cover. > 102 lumen/ watt, lumen maintenance > 70% at 50,000 hrs, colour temperature of 5000-6000, >70 colour rendering. The driver must be integral APFC and constant current type having THD <20% and power factor >0.9 with reverse polarity protection and open circuit protection with suitable batten fitting.
Vertical TPN DB, 4 way with provision to mount 3 pole V-Tec 50 KA MCCB upto 100 A as incomer complete all as specified.
MCCB 100 A with electronic release Microprocessor based, breaking capacity 50 KA, 3 pole, complete all as specified.
S&F Voltage stablizer for automatic operation, single phase naturally cooled, indoor type and disigned for input variation between 170 V to 260 V with output voltage stablized at 220 V ± 9% with accuracy of +3% and capacity 2 KVA complete all as specified and directed.
Supply and fix desert cooler electric driven single phase, having nominal air flow capacity of 4000 Cum per hour or nearest. Plastic body, tank capacity 60 Ltrs, honey comb cooling pads, smart humidity control including necessary fixing arrangement with suitable size of angle iron all as specified and directed by E-in- Charge.
M&L for granite (of any type) tiles 20mm thick machine cut, in skirting/dado/RCC Column laid over cement screed of mortar 10mm thick Cement mortar 1:4 for laying vertical granite finishes and pointed with white cement with admixture of pigment to match the shade of granite stone Including grinding and polishing types as specified.
Construction of sluice valve pit chamber having internal dimension 120x120x120cm (internal height) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the stone masonary/brick work with 1:6 cemet mortar PCC (1:2:4) type B1 coping with 20 mm graded aggrement including 50 mm pad lock with double key arrangement, MS frame made out of 40 x40 x 6 mm thick angle iron incl painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers finishing coat incl necessary excavation in any type of soil returning filling in and removal of surplus soil to a distance not exc. 50 mtrs all as specified.
Taking out non return valve of 100 mm dia and refixing the same at another place after re-fixing the 100 mm pipe line complete all as specified and directed by Engr-in-Charge.
Taking out gate valve with iron wheel head screwed both ends for iron pipe 50 mm dia complete all as specified and directed.
Taking out gate valve with iron wheel head screwed both ends for iron pipe 25 mm dia complete all as specified and directed.
Construction of sluice valve pit chamber having internal dimension 75 cm x75 cm x75 cm (internal height) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the stone masonary/brick work with 1:6 cemet mortar PCC (1:2:4) type B1 coping with 20 mm graded aggrement including 50 mm pad lock with double key arrangement, MS frame made out of 40 x40 x 6 mm thick angle iron incl painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers finishing coat incl necessary excavation in any type of soil returning filling in and removal of surplus soil to a distance not exc. 50 mtrs all as specified.
M&L for cutting of existing road for crossing of MS/DI/CI/GI Pipes for laying of any size pipes including necessary excavation and earth work including repairing the same as per existing with pre mix bituminous carpet, width of trench shall be 0.45 m & depth shall be up to 1.5 m complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 15 mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion.
Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40 mm bore upto 5m length for drawing in earth strip, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion.
Supply and fix LED 70 watt, IP 66 LED Streel light luminaries on suitable length & size of GI bracket comprising of die cast aluminium housing with weather proof gasket of lamp and driver compartment with 120 degree veiw angle, lumen output > 100 lumen/watt, lumen maintenance> 70% at 50000hrs, colour temp 5000-6500k, CRl>70, THD<15%, PF>0.95 and LM 80 test compliance. The driver must be intergated APFC with short circuit protection, reverse polarity protection against 5KV high surges and comply with IEC 61000-3, IEC-61547. The luminairs must have secondary optics with perfectly matched lens for better light control including making electrical connection specified and as directed.
Supply and fix thermoplastic cable junction box/distribution board IP 66 halogen free wheather proof for outdoor installation with metric knockouts for cable entry of size upto 10 sq mm x 2 core including fatening clamp with LT pole box size 167x125x82 mm hinged cover with locking arrangements. Make-Hensel or equivalent of Sintex complete all as specified
Construction of PCC platform for transformer of size 3.0x2.5x1.2 m high from ground level with brick construction in walls and steps, XPM fencing with angle ironpost including gate with locking arrangement, PCC 1:5:10 type E-2 in foundation, brick work in CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4, type B-1(using 20mm graded crushed stone aggregate) in flooring, 40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and shown on drawings.
Taking down the unserviceable HT/LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed by engineer in charge .
Taking proper shut down in writing and disconnecting up the LT and HT electric mains from transformer of capacity 63 KVA removing from pole structure/platform shifting to near by location by using crane and any other equipment complete all as directed by Engr-in-charge. Note:- Temp arrangement for electric supply to the connected offices will be provided by the contractor till re-fixing of the transformers and restoration of electric supply and arrangement for the same shall be deemed to be include in quoted rates without any extra cost to Govt.
Dismantling of existing earthing including GI strip, plates, chabmer, and all connected items complete all as specefied and directed.
Dismantling of existing LT Panel and MCCBs and all connected items complete all as specefied and directed.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 15 mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion.
Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40 mm bore upto 5m length for drawing in earth strip, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion.
Supply, Installation , testing and commissioing in replacement outdoor type, weather proof, cubicle panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40x40x6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15x15x15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliset for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry. The panel shall accomodate the following equipments:-
Aluminium Bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 Amps for phases and neutral - 01 set
Panel indicating lamp neon/LED type (Red, Yellow & Blue) with lamp holders - 03 Nos
Panel instrumental wiring with FRLS suitable size but not less than 2.5 Sqmm copper wire single core - 01 Job
INCOMING
MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 160 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos
OUT GOING
MCCB 4 Pole, Ics = 100% Icu,25/26KA, 415 Volts, 125 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos
MCCB 4 Pole, Ics = 100% Icu,25/26KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos
MCB SPN 32 Amps 16 KA, 230 volts - 02 Nos
Construction of PCC platform for transformer of size 3.0x2.5x1.2 m high from ground level with brick construction in walls and steps, XPM fencing with angle ironpost including gate with locking arrangement, PCC 1:5:10 type E-2 in foundation, brick work in CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4, type B-1(using 20mm graded crushed stone aggregate) in flooring, 40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and shown on drawings.
Deduct Schedule of Credit materials of Rs (-) 85976.00 (Minus) as listed in Schedule 'A' Part-XXII Lumpsum contract sum shall be arrived at after deducting the credit schedule amount. Note: Tenderers will not quote against this item being a firm amount.
R R CONSTRUCTION
M/S TIKAM CHAND JAIN
M/S VED PARKASH GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .