| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.3 L+₹3.4 L (17.4%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹23.9 L+₹4.0 L (20.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹24.8 L+₹5.0 L (25.0%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹25.4 L+₹5.6 L (28.0%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
5 Aug 2020, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR / MAINT OF INTERNAL ELECTRIFICATION WORKS IN CERTAIN MD OFFRS ACCN AT PRATAP LINE AND CERTAIN MD/OTM ACCN IN ZONE-I AND ZONE-II AREA UNDER GE JAIPUR.
2020_MES_359958_1
GE/J-15 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JAIPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE JAIPUR
₹66,000
Yes
3 Sept 2020
10 Jul 2020
7 Aug 2020
10 Jul 2020
5 Aug 2020
23 Jul 2020
10 Jul 2020 - 22 Jul 2020
Amount
Taking down carefully aluminum or copper point wiring with PVC casing capping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&Lfor rewiring point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into concealed conduit and terminated in modular metal flush boxes 1.0mm thick for mounting modular cover plate & frame, switches, sockets, fan regulators as required for one light point controlled by one switch.
All as per item No. 02 here-in-before but one fan point controlled by one switch.
All as per item No. 02 here-in-before but one light point controlled by two, two way switch.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 02 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into into existing concealed conduit and terminated in modular metal flush boxes for mounting modular cover plate & frame for one socket point 16 Amps controlled by one switch.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 09 above but one light point controlled by two, two way switch.
All as per item No. 09 above but one fan point controlled by one switch.
All as per item No. 09 above but one socket outlet 6 Amps controled by one switch on the same board with other switches.
All as per item No. 09 above but one socket outlet 6 Amps controlled by one switch on independent board.
All as per item No. 09 above but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets for one 16 Amps socket outlet point controlled by one switch on independent board.
M&Lfor rewiring point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into concealed conduit and terminated ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 16 here-in-before but one fan point controlled by one switch.
All as per item No. 16 here-in-before but one light point controlled by two, two way switch.
All as per item No. 16 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 16 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 16 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn concealed conduit and terminatedivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, for one socket point 16 Amps controlled by one switch.
S&F angle holder, insulated polycarbonate body with back plate complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F switch piano flush button single pole one way 6 Amp complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F switch piano flush button single pole one way 16 Amp complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F flush type, 6 Amp, single pole, two way complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F bell push, flush type, 6 Amps 240 volts complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete. Make:Anchor Penta PC/Havells Reo/SSK as approved.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F switch modular 1 way 6 Amps, 230 volts, 1 module.Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular switch 1 way 16 Amps, 230 volts, 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular fan regulator 120 watts, 2-module AC 230 Volts. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F switch modular 2 way 6 Amps, 230 volts, 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular bell push 6 Amps 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S & F modular blanking plate 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular whiter cover plate with frame 1/2 module.
S&F modular whiter cover plate with frame 3 module.
S&F modular whiter cover plate with frame 4 module.
S&F modular whiter cover plate with frame 6 module.
S&F modular whiter cover plate with frame 8 module.
S&F Modular metal flush box 1/2 module
S&F Modular metal flush box 3 module
S&F Modular metal flush box 4 module
S&F Modular metal flush box 6 module
S&F Modular metal flush box 8 module
S&F door bell AC 240 volts, single pole complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in replacement switch modular 1 way 6 Amps, 230 volts, 1 module.Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F in replacement modular socket 6 Amps, 2/3pin combined 2 module AC 230 volts. Make : Legrand Arteor series/ Schneider Zencilo series/Crabtree Murena series as approved.
S&F in replacement modular switch 1 way 16 Amps, 230 volts, 1 module.Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F in replacement modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F in replacement modular fan regulator 120 watts, 2-module AC 230 Volts. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F in replacement switch modular 2 way 6 Amps, 230 volts, 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F in replacement modular bell push 6 Amps 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S & F in replacement modular blanking plate 1 module. Make : Legrand Arteor series/Schneider Zencilo series/Crabtree Murena series as approved.
S&F in replacement modular whiter cover plate with frame and metal flush box 1/2 module.
S&F in replacementin replacement modular whiter cover plate with frame and metal flush box 3 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 4 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 6 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 8 module.
S&F ceiling rose 3 plates polycarbonate body complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
M&L for sub main wiring along with earth continuity conductor with, PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories 2x4Sqmm + 1x4.0 Sqmm earth wire in 20mm dia conduit.
All as per item No. 64 above but 2x6 Sqmm + 1x6 Sqmm earth in 20 mm dia conduit.
All as per item No. 64 above but 2x10 Sqmm + 1x10 Sqmm earth in 25mm dia conduit.
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point and including 15mm bore light grade G.I. protection pipe (upto 7.5 mtr from edge of the pit), PCC pit in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40mm thick cover, watering arrangement with funnel and wire mesh and 20mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways.
All as per item No. 68 above but SPN, 240 volts, 8 ways.
All as per item No. 68 above but SPN, 240 volts, 12 ways.
All as per item No. 68 above but SPN, 240 volts, 2 ways.
S&F MCCB four pole, 125 Amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required.
S&F MCB distribution board, tripple pole and neutral, powder coated CRCA steel sheet, suitable for MCCB incomer upto 160 Amps, 4 way 415 volts, degree of protection IP 43, IK-09 with reversible double door, recess mounted, having 250 Amps insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
All as per item No. 74 above but double pole 10 to 40 Amps.
S&F LED batten (1.2M) made of CRCA sheet housing duly prewired connection having a nominal system total power consumption not more than 20 watt including T8 LED tube life time of 15000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete. Make : Philips/ Crompton /Havells / Bajaj/Panasonic as approved by GE
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 125 lumen per watt and total power consumption not more than 16 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete.
S&F LED fixture 10 watt having lumen output 100 lumens per watt including connection.
S&F LED bulk head fitting 9 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable.
Supply and fixing in replacement 8 watts wall mounted LED decorative luminary with standard accessories and lamp inclduing fixing the same with existing wall.
Supply and fix in replacement LED luminary 35 watts IP 66 5700K outdoor luminary with standard accessories and making connection with existing light point with 3 core 1.0 Sqmm PVC insulated multistranded copper conductor wire including fixing the same on existing Gi bracket complete.
Supply and fixing in replacement GI bracket made out of 32mm dia GI medium grade pipe of length 90 Cms long bend shape and size as per site requirement including 02 Nos of MS flat 40x5mm 200mm long bend to shape as required to fix the G bracket with existing wall using 04 Nos of MS fastener 10mmx100mm long with nut, bolts and washers complete.
Supply and fix in replacement 10 watts LED T-lamp B-22 base (warm white/Golden Yellow) 100 lumens, AC 220 volts .
Taking down MCB distribution boards with incoming and outgoing controls any make any capacity after disconnecting complete.
Taking down carefully sub main wiring with PVC casing capping/PVC surface conduit and making good disturbed surfaces complete.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core.
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed.
Sand cushioning to the under ground electric cable complete all as specified considering 19.75 of SSR part -I
S&F steel tubes 40 mm bore light grade ISI marked with medium grade fittings for cable protection as required.
M/L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall build on cement mortar 1:4 and 2 coats of white/colour washing to match the surface complete.
Rewinding the motor of table / pedestal / cabin fan 400 mm of all types and make with super enameled copper wire of existing gauge and approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Rewinding the motor of ceiling fan 1200/1400 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Rewinding the motor of fresh air/exhaust fan 230/300 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Rewinding the motor of exhaust fan 375/450 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Opening ceiling fan of any make any sweep for overhauling, providing fresh clean lubricating oil / grease including minor repairs, renewal of split pins, re-assembling and testing for satisfactory operation complete. (Note - Any u/s parts as renewed shall be measured separately).
Rewinding the motor of wall mount air circulator fan of size 600 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Renewal of ball bearing of ceiling / exhaust fan of any size and make as required with alignment of shaft and testing complete. Make - SKF (6201 to 6203) or equivalent in TATA as approved.
Renewal of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete. Make - Havells cat ref no. 2.5 mfd / 440V / PLWW / 25x45 or equivalent in Epcos / Usha as approved.
Renewal of AC film capacitor 4.0 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete.
Renewal of self lubricating bush of gun metal of same type for ceiling fan / exhaust fan as required.
Renewal of shaft of approved quality for ceiling fan / exhaust fan any make any type & size as required.
M&L for painting of table / pedestal / cabin fan of any sweep and make with one or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface with detergent etc and writing MES No with black paint as required.
M&L for painting of ceiling fan of any sweep and make with one or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface with detergent etc and writing MES No in a height of minimum 30 mm with black paint as required .
M&L for scraping completely fresh air / exhaust fan of any sweep and make and providing with two or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade over a coat of red oxide primer and polishing with rubbing compound and wax polish and writing MES No with approved colour paint as required.
Transportation of ceiling fan / exhaust fan from store to site or site to store as required.
Installing, testing and commissioning repaired ceiling fans at any location in cantonment Jaipur including connection complete.
Renewal of rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required.
Renewal of PVC canopy suitable for ceiling fan of any size and make as required.
Renewal of down rod of ceiling fan made of MS pipe 15 mm bore including cutting, threading, painting etc as 30 cm to 60 Cm required.
M&L for clamp and back plates fabricated from steel sections conforming to Gde Fe 410-O or Fe 310-O including nuts, bolts, washer, drilling holes for bolts in any shape or size for fixing ceiling fan complete.
Renewal of PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm complete.
Supply and fix in replacement PVC fresh air fan 250 mm sweep with louvers, fan motor and accessories complete including making connections. Make : Bajaj/Havells/CG as approved.
Supply and fixing ceiling fan 1200mm sweep 50 Hz AC 230 votls, 5 star rated in white colour with fan motor, blade set, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as required. Make : Havells Model No. ES-50 or equivalent in Orient/CG/Standard as approved by GE
Taking down carefully storage type water heater (geyser) any make and capacity from clamp/bolts including disconnecting water and electric connection and re fixing the same and connecting up after cleaning of geyser and repair complete. (Note - Repair work shall be measured separately).
Opening up geyser of capacity 25/50 litre, checking defect, taking out u/s parts and re-assembling after carrying out repair / renewal work including nuts / bolts / wahers / gaskets / fusible plug etc wherever required and minor items not included separately in schedule. (Note - U/s parts shall be measured separately under relevant item of schedule as supply only).
Supply only geyser apparatus plate (any make, any type) copper alloy chromium plated suitable for geysers 25/50 litre capacity including rubber gasket, nuts / bolts etc complete.
Supply only heating element 2.0 KW, 230 volts, ISI marked suitable for 50 litre capacity geysers of any type as required.
Suppply only thermostat ISI marked suitable for 25/50 litres geysers as required.
Supply only stainless steel inner tank suitable for 25 litre capacity geysers housing complete.
Suppply only stainless steel inner tank suitable for 50 litre capacity geysers housing complete.
Repair of inner copper tank of geysers 25/50 litre capacity with gas welding not exceeding 5 mm thick to make it leak proof complete.
Repair of apparatus plate of geysers 25/50 litre capacity by brazing not exceeding 5 mm thick complete.
Renewal of brass chromium plated, flexible pipe connection 15 mm bore 450 mm long heavy duty suitable for hot water supply with two numbers brass chromium plated nuts at end complete.
M&L for painting of geyser 25/50 litre with two coats of synthetic enameled white paint after removing old paint and preparation of surface and writing MES No (Letters height 10 cm) complete.
S&F water heater 25 litre capacity BEE star rating 5 in approved colour, heating element 2.0 KW, adjustable temperature setting knob for temperature setting between 25° C to 75° C, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insullation complete. Make- Hevells Adonia or equivalent in Daspass or Recold or Bajaj as approved.
Renewal of PVC insulated over all PVC sheathed three core copper cable of size 2.5 sqmm complete.
M&Lfor rewiring point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into concealed conduit and terminated ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 130 here-in-before but one fan point controlled by one switch.
All as per item No. 130 here-in-before but one light point controlled by two, two way switch.
All as per item No. 130 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 130 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 130 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn concealed conduit and terminatedivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, for one socket point 16 Amps controlled by one switch.
M&L for sub main wiring along with earth continuity conductor with, PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories 2x6.0Sqmm + 1x6.0 Sqmm earth wire in 20mm dia conduit.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways. Make : Legrand Cat Ref No. 507612 or Schneider or equvelent Hager as approved.
S&F door bell AC 240 volts, single pole complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair switch piano flush button single pole one way 6 Amp complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair switch piano flush button single pole one way 16 Amp complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair flush type, 6 Amp, single pole, two way complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair bell push, flush type, 6 Amps 240 volts complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair socket outlet, 2-in-1, 3 pin 6 Amps flush type compete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S&F in repair hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete. Make : Anchor Penta PC/Havells Reo/SSK as approved.
S & F in repair MS box of size 200mmx150mmx50mm deep, fabricated out of 1.0mm thick MS sheet for mounting switches, sockets, fan regulators etc including cuttings chases in exisiting wall for recessing the same and fair finish the surface in CM 1:4 complete. Note : Laminated sheet and switches, sockets, fan regulaotrs, bell pushes shall be measured and pair for seperately under relevant items of BOQ.
S & F in repair MS box of size 250mmx150mmx50mm deep, fabricated out of 1.0mm thick MS sheet for mounting switches, sockets, fan regulators etc including cuttings chases in exisiting wall for recessing the same and fair finish the surface in CM 1:4 complete. Note : Laminated sheet and switches, sockets, fan regulaotrs, bell pushes shall be measured and pair for seperately under relevant items of BOQ.
S & F in repair MS box of size 100mmx100mmx50mm deep, fabricated out of 1.0mm thick MS sheet for mounting switches, sockets, fan regulators etc including cuttings chases in exisiting wall for recessing the same and fair finish the surface in CM 1:4 complete. Note : Laminated sheet and switches, sockets, fan regulaotrs, bell pushes shall be measured and pair for seperately under relevant items of BOQ.
S & F in repair MS box of size 175mmx100mmx50mm deep, fabricated out of 1.0mm thick MS sheet for mounting switches, sockets, fan regulators etc including cuttings chases in exisiting wall for recessing the same and fair finish the surface in CM 1:4 complete. Note : Laminated sheet and switches, sockets, fan regulaotrs, bell pushes shall be measured and pair for seperately under relevant items of BOQ.
S&F in renewal phenolic laminated white sheet cover 3.0mm thick, cut into required size suitable for fixing on existing boards/terminal boxes for mounting switches, sockets, regulators as required.
Supply only dis cut out switch suitable for 25 litre capacity geysers (make of geyser MARC) complete.
Supply only capillary thermostat set suitable for 25 litre capacity geysers (make of geyser MARC) complete.
S&F in replacement hot water pipe duly insulated with glass wool and aluminium cladding 15mm bore.
Servicing of solar collector panel of capacity 100 ltrs, cleaning the entire panel thoroughly after opening it, minor repair like nuts, bolts, washer, clamps etc as required and testing.
Schedule of Credit (As per tender documents)
M/s Radhey Enterprises
Ms Hari Deva Builders
J.J.ENGINEERING
M/s Prakash Enterprises
M/S Sheeba Enterprises
M/S TRADE LINKERS
SHREE BHAGWATI ENTERPRISES
agrawal constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .