| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹20.9 L+₹82,665 (4.11%)Rejected-AOC RZ F1 104 MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-AOC higher rate | |
| 3 | L3₹24.8 L+₹4.7 L (23.2%)Rejected-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L3 | Rejected-AOC higher rate |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
24 Dec 2022, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI
CA NO GE/ND-70/2022-23 REPAIR/ MAINT OF SEWER LINE, MANHOLES, CLEANING OF SEWER APPURTENANCES AND SEWAGE LINES IN ABHM AND REPAIRS TO HARD STANDING, CULVERTS/ DRAIN, FOOT PATHS AND MISC ITEMS AND COMPREHENSIVE REPAIRS/MAINT INCL ROOF REPAIRS, LEAKAG
2022_MES_564646_1
GE/ND-70/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹74,000
Yes
31 Mar 2023
22 Nov 2022
26 Dec 2022
22 Nov 2022
24 Dec 2022
10 Dec 2022
Amount
Demolition of cement concrete unreinforced of any description and in any position not other wise specifically provided including removing the unserviceable material out side the MOD land complete all as specified & directed.
Demolition of reinforced cement concrete of any description and any position no otherwise specifically ( below or above ground level) including cutting of reinforcement as required to facilitate demolition incl removing the unserviceable material out side the MOD land complete all as specified & directed.
Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, drains, culverts and walls etc but excluding ashlar facings, dressed stone work and pre cast concrete articles, built in cement mortar incl removing the unserviceable material out side the MOD land complete all as specified & directed.
M&L for lean concrete 1:4:8 type D2(using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for concrete work in pavement/hard-standing of flexural strength 40kg/per square centimetre in filled using 400 kg of cement per cubic metre, thickness of concrete (using 20 mm graded stone aggregate) finished rough surface without using extra cement incl necessary use of form work complete all as specified and directed.
M&L for forming 12mm thick Expansion joint filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'A' as in hard standing complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40 mm graded Agg) as in drain finished even & smooth surface without using extra cement complete all as specified.
M & L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in plinth courses, string courses, mud stops or roof kerbs, benching, copings, channels, slightly chamfered or rounded on edge including necessary use of form work complete all as specified & directed at site.
M&L for 100 mm thick PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in hard standing, paths, floor etc. finished rough surface without using extra cement complete all as specified.
M&L for 75 mm thick PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in floor etc. finished rough surface without using extra cement complete all as specified.
M&L 40mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor finished even and smooth surface without using extra cement complete all as specified and directed.
M&L pre cast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slabs for manholes, drains and such similar works including set in CM 1:6. complete all as specified.
M&L for reinforced cement concrete (Nominal Mix) using 20 mm graded aggregate as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, chajja, deck slab and in shelves and the like complete all as specified and directed.
M&L Form work to soffits of suspended slab such as roof slab floor slab landings and similar work flat for fair finished surface complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description and any positions not other wise provided for complete all as specified and directed.
S&F for angle iron and framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, welded or forged into spikes framed guard bars, barred doors & walk ways railings frame work of water tank and similar work confirming to Fe-290 Gde -E-165
Taking down cement plaster of any description on brick or stone walls, drains, manholes etc including removal of any vegetable, grasses, shrubs, bushes, raking out joints, hacking for key and scrubbing down with water etc to receive new plaster up to 6 storey buildings incl necessary safety precaution, scaffolding and framed work complete all as specified and directed.
M&L for premix/ready-mix plaster 15mm thick on brick or concrete surfaces of walls, chajja, roofs, beams, columns etc in CM 1:4 finished even & smooth without using extra cement over a coat of UltraTech seal and dry 5 plush as bonding agent including necessary form work safety precaution up to six storey bldgs. complete all as specified & directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc. 6.00 m mean radius built in CM 1:6 complete all as specified.
M&L brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick built in CM 1:4 complete all as specified.
M&L for walling of random rubble stone masonry uncoursed well bonded bedded and solidity hearted built in CM 1:6 brought up to coursed complete all as specified and directed.
Extra over stone walling for hammer dressing to face stone and dressing face beds joints as specified of random rubble walling uncoursed or brought up to courses surface n.exc. 40mm complete all as specified and directed.
Mel for hand packed tightly broken stone boulders of any thickness at back filling of retaining walls over arches etc complete all as specified and directed.
M&L for raised pointing to random rubble masonry uncoursed or brought up to courses in CM 1:4 complete all as specified and directed.
M&L polymer modified cement bonding coat, prepared and applied on the concrete/masonry surface with 1 part of Sika latex with 4 part of water and 6 part of cement by weight. Coverage Sika latex 0.25 kg/sqm for one coat at all heights levels. Adhesive bond strength not less than 2.5 MPa. (Make :- Sika/BASE Fosroc/Dr Sunanda) including chipping of the loose concrete all as directed by Engineer-in-Charge..
M&L applying two coats of oil bound distemper over a coat of primer on new plastered surfaces including match with existing surfaces and preparation of new plastered or old adjoining surfaces complete to bring the surface to the entire satisfaction of Engr-in-charge.
M&L applying two coat of oil bound distemper over 3 mm thick wall care putty to provide silky smooth finish after preparation of new plastered wall surface complete surface finished the smooth surface of walls.
M&L for Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall care putty on new surfaces of external walls / ceiling surfaces after preparation of surface all as specified by Engineer-in-Charge.
M&L for applying two coats of cement base paint on external wall surface on new plastered or old plastered surface incl surface preparation surfaces complete all as specified and directed.
M&L for two coats of synthetic enamel paint on new steel and iron surfaces over a coat of red oxide primer incl preparation of surfaces over 10 cm width of girth complete all as specified and directed.
M&L for one coats of synthetic enamel paint on old steel and iron surfaces incl preparation of surfaces over 10 cm width or girth complete all as specified and directed.
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as directed by Engr-in-Charge.
Ditto as per item no 32 above here-in-before but 6 to 8 mm dia
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for Dismantling floor hearth and wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and directed.
Dismantling of Stone slabs and tiles any pattern, paver block of any description or thickness in floors, aprons, vertical surface of walls etc..
M&L machine pressed pre cast concrete interlocking decorative paver block PU coated of any size and shape confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and no pigment, size and shape of paver as approved complete all as specified and directed.
M& L for Endura chequered tiles of approved colour and design 10 to 12mm thick (Square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in paths, floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for chequered cement concrete tiles 200x200x25mm/300x300x25mm thick of approved colour and design (Square/ rectangular) as in paths, floors etc set and jointed in neat cement slurry with gray cement and pigment over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L laying of fine aggregate ( sand) 50 mm thick for laying of interlocking paver vide item No 15 above including watering and consolidation etc complete all as specified.
Supply and laying of reinforced concrete pipes of 600 mm bore pipes, class NP 2, laid and jointed with collars complete all as specified and directed.
Supply and laying of reinforced concrete pipes of 300 mm bore pipes, class NP 2, laid and jointed with collars complete all as specified and directed.
Demolition/dismantling of AAP polymeric membrane or terracing tiles, PCC, plastering & leaping plaster on roof laid, bedded and pointed in any thickness, mortar incl removing the unserviceable material out side the MOD land.
M/L for cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3.complete all as specified and directed.
M & L for :- (a) Cleaning the surface, remove dust, dirt, loose particles and unsound substrate and grading with cement mortar (1:4), 10 mm thick, as in slab surfaces, beams, columns, parapet and junction of walls etc., grading with a slope of 1 in 120 mixed with liquid/ integral water proofing compound as per manufacturer's instruction as approved by GE (water proofing compound to be measured separately only for cement mortar/ PCC Work (b) Applying evenly a tack coat of water proofing shield primer @ 0.50 kg/Sqm as a bonding layer over finished plaster surface including cleaning the surface. (c) Over the coat of bitumen bonding layer as above APP modified polymeric membrane (weight not less than 3.0 kg/Sqm) and 3 mm thick reinforced with polyester non wove fabric, unrolled and bonded completely to the substrate with side overlap of 75 mm or end over lap of 100 mm. The overlaps are then sealed/ fused by flame technology method as per manufacturer's instruction. (d) Sealing edges well into grooves & protect with CM 1:2 complete all as specified and directed. Note :- The work for water proofing treatment on roofs shall be executed through original manufacturer's or their authorised applicator.
M&L 40 mm thick PCC 1:2:4,type B-1 using 20mm graded aggregate mixed with water proofing compound as per manufacture instruction as in roof floors. (water proofing compound to be measured separately).
M&L for cement concrete tiles of size 25 cm x 25 cm x 22 mm / 30 cm x 30cm x 20 mm thick, machine pressed, set, jointed and pointed in neat cement slurry with grey cement and no pigment in roofs, floors over and including screed bed or bedding layer of cement mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified.
Dismantling loose concrete cover of RCC columns, beams, slabs, chajjas, parapets, railing, and the like as directed without disturbing the core of RCC member, roughening and cleaning concrete surfaces with steel wire brushes, washed with water and allowed to dry, including application of rust removal cum passivator painted with brush to the rusted reinforcement (and removing rust with flex after 24 hours of application of rust remover with the help of wire brush, sand paper) and also applying zinc anti-rust agent as per manufactures method of application to re bar corrosion protection system to reinforcement surface of steel reinforcement after that applying polymer modified cementitious bonding coat, prepared and applied on the concrete surface with 1 part of sika latex or equivalent in Forsoc/BASF/Dr Sunanda with 4 part of water and 6 part of cement by weight, coverage of sika latex shall not be more than 0.25 Kg/Sqm for one coat. Adhesive bond strength not less that 2.5 mpa, After this, providing 40mm (average thickness) guniting mix @ pressure 2.2 to 2.5 kg per sq.cm. with anti corrosion admixture (using 1 part of ordinary Portland cement 43grade and 2part of Ghagger sand mixed with adhesive/admixture at the rate as per manufacturer instruction and as directed) including stripping floating with wooden strippers for proper dimension control necessary, formwork and scaffolding, complete surface of guniting to be finished fair with 10mm thick plaster in Cement Mortar 1:4 with water proofing compound as per manufacture instructions cleaning and removing of waste material etc as directed at site. (All services and work incl internal and external surfaces and members including necessary scaffolding, framed, safety precautions of up to six storey buildings and narrow toilet shaft.
S&F welded steel wire fabric, n.exc. 4 Kg weight per sqm, cut to length bent to shape required and fixing with galvanised steel staples or welding supplied and fixed complete to wood or steel members.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including cement screed base 20mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Butch stone cladding of size 150 x 600mm and 15 to 20 mm thick as in vertical surfaces such as dado/skirting laid over and including rendering 10 mm thick in CM 1:4 jointed with grey cement slurry and incl pointing in white cement (1:2) with admixture of pigment to match with shade including cutting and polishing complete.
S&F for mosaic tiles of size 50x50mm and 5 to 10mm thickness approved coloured and design (Squarer/rectangular) as in floors, walls etc set and jointed in with solution as per approved to match incl 10mm thick rendering in cement mortar 1:4 complete all as specified and directed..
S & F providing precast cement concrete louvers and jallies with 1:2:4 type B0 mix (using 12:5 mm graded stone aggregate) including all mouldings but excluding frame, and set in CM 1:4 complete all as specified.
M&L for Providing precast cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) set in CM 1:6 as in louvers and jallies, window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section dictated), with plain fair faces, including chamfers, weathering, throating etc. and setting in mortar complete with joints to match complete all as specified.
M&L for rebuilding the section of structural damaged spalled concrete or RCC elements to its original size or as per recommendations by engineer-in-charge in thickness up to 40mm in layers of 20 mm each of average thickness 30mm by providing and applying with pre-batched, one component fiber reinforced cementitious polymer modified mortar having compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109; flexural strength >= 5N/ mm2 (7 days) according to ASTM C 293-79 all as specified & directed .
M&L for laying Micro-concrete cement based pre packed single component, chloride free, sulphate free, non shrink, free flow, self compacting, ready to use after mixing water in specified proportion of approved quality. The unit rate shall include the cost of form work for providing micro concrete patch repair as required at site with steel jack system and steel props to support the form work in this application of high strength, dual shrinkage, compensated, micro concrete for placing in nominal thickness of 50 mm to 150 mm for concrete repair. Make:- Sika/BASE Fosroc/Dr Sunanda.
Providing and fixing rebar of required length & diameter with Sika anchor fix R-3+/Mungo/Fischer FISV 390/Hilti RE-500 Epoxy resign where ever required in RCC members including power drilling, cleaning of holes then rebar shall be inserted in holes that shall be fixed with epoxy to ensure the bond as per manufacturers recommendation complete as per site requirement and direction of Engineer-in-Charge of 100 mm deep(minimum), 16 mm dia hole suitable for inserting 12 mm dia reinforcement bars (All services and work, scaffolding, safety precautions including internal and external surfaces and members of six storey building).
Providing and fixing rebar of required length & diameter with Sika anchor fix R-3+/Mungo/Fischer FISV 390/Hilti RE-500 Epoxy resign where ever required in RCC members including power drilling, cleaning of holes then rebar shall be inserted in holes that shall be fixed with epoxy to ensure the bond as per manufacturers recommendation complete as per site requirement and direction of Engineer-in-Charge of 100 mm deep(Minimum), 12 mm dia hole suitable for inserting 08 mm dia reinforcement bars (All services and work, scaffolding, safety precautions including internal and external surfaces and members of six storey building).
Excavating in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation for manholes / shafts or sewer line etc and getting out all as specified.
Excavating in trenches in any type of soil, not exceeding 1.5m wide, exceeding 1.5m in depth but not exceeding 3.0 m in depth for foundation for manholes / shafts or sewer line etc and getting out all as specified.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar, bore of pipe 150mm.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar, bore of pipe 200mm.
M & L Cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipe of 150 mm bore after they are laid and tested.
M & L Cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipe of 200 mm bore after they are laid and tested.
M & L Salt glazed stone ware ( SGSW ) drain pipes, Grade ‘A’ 150 mm bore, laying level or to falls in trenches, on concrete bed or directly on hard grounds and making joints and testing complete.
M & L Salt glazed stone ware ( SGSW ) drain pipes, Grade ‘A’ 200 mm bore, laying level or to falls in trenches, on concrete bed or directly on hard grounds and making joints and testing complete.
S&F in repair vitreous china wash down water closet pedestal pattern white incl valveless syphonic action type PVC low level flushing cistern with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete with plastic water closet seat white closed pattern with flat bottom & cover & mild steel chromium plated or aluminium hinges device & flush pipe of polythene of low or high density of PVC 32mm dia for low level PVC cistern. (Make: HINDWARE/PARRY WARE/CERA) Ist quality.
S&F in repair water closet vitreous china squatting pan of ORISSA pattern size 580 mm X 440 mm white with integral foot rest incl setting the cast iron trap & pan into cement and sand mortar, provn of lime concrete bedding complete incl. valveless syphonic action type PVC low level flushing cistern with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete
Returning filling in including spreading levelling, watering and well ramming soil in layers n. exc. 25 cm thick complete all as specified.
Removing excavated materials/surplus soil beyond 50 m and up to total distance of 250 m complete all as directed by Engineer-in-charge.
M & L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in benching, copings, channels, slightly chamfered or rounded on edge including necessary use of form work complete all as specified & directed at site.
M&L cleaning, flushing of chocked and de-silting of outdoor sewage lines n.exc. 300mm internal diameter of any depth upto three meter . The cleaning shall be carried out with mechanized operation by means of diesel/electric operated vehicle mounted hydraulic operated high pressure suction cum jetting machines fitted with pump of requisite capacity and the sludge sucked out with super sucker machine of required capacity and sent to storage tanks for further disposal to the authorised disposal sites. The sludge deposited in the sewage line shall be fully cleaned and disposed off the same outside the MoD land at any distance and without any additional cost on the same day when it was taken out. The job shall be carried out with safety precaution equipment and with strict supervision complete all as directed. Note:- (a) The service provider/contractor during the mechanized operation shall be equipped with gas monitor, nylon rope ladder, torch light and compressor blower etc alongwith the sewage cleaning truck mounted suction/jetting machine. (b) Manual cleaning operation/scavenging is prohibited. (c) The unit rate quoted by the contractor shall interalia deem to include the cost of providing skilled driver and operator and supervising Engineer including provision of water for jetting and removal of sludge/silt/liquid/mud and sand (in foul position) etc (d) The effective length of pipe for the purpose of payment shall be excluding the length of manhole.
Desludging of existing chocked manholes of depth upto 2.5 m for liquid, solids and slurry material by mechanical means using hydraulic operated high pressure suction cum jetting sewer cleaning machine having jetting tank capacity of minimum 5000 Ltr and suction tank capacity of 300 Ltrs and 260 LPM with minimum 145 bar suction flow of 10200 LPM including skilled driver and operator and supervising Engineer including provision of water for jetting and removal of sludge/silt/liquid/mud and sand (in foul position) etc outside the MOD land/premises at any distance all as directed by Engr-in-Charge including loading, unloading, digging out pit of any size in any type of soil, slurring sludge/silt/spoil/mud etc into the pit and spraying bleaching powder over the entire surface complete including taking of the manhole cover for the entire process as above and replacing the manhole cover in its position. Note :- (a) The service provider/contractor during the mechanized operation shall be equipped with gas monitor, nylon rope ladder, torch light and compressor blower etc alongwith the sewage cleaning truck mounted suction/jetting machine. (b) The cleaning shall be carried out with mechanized operation by means of jetting machines and the sludge sucked out with super sucker machine of required capacity and sent to storage tanks for further disposal to the authorised disposal sites. (c) Manual cleaning operation/scavenging is prohibited. (d) The unit rate shall deem to include for all material, labour (skilled/unskilled), tools and plants and requisite quantity of water for the entire operation and transportation arrangements. (e) The sludge so removed shall include the cost of dewatering also.
Desludging of existing chocked manholes of depth upto 4.50 m for liquid, solids and slurry material by mechanical means using hydraulic operated high pressure suction cum jetting sewer cleaning machine having jetting tank capacity of minimum 5000 Ltr and suction tank capacity of 300 Ltrs and 260 LPM with minimum 145 bar suction flow of 10200 LPM including skilled driver and operator and supervising Engineer including provision of water for jetting and removal of sludge/silt/liquid/mud and sand (in foul position) etc outside the MOD land/premises at any distance all as directed by Engr-in-Charge including loading, unloading, digging out pit of any size in any type of soil, slurring sludge/silt/spoil/mud etc into the pit and spraying bleaching powder over the entire surface complete including taking of the manhole cover for the entire process as above and replacing the manhole cover in its position. Note :- (a) The service provider/contractor during the mechanized operation shall be equipped with gas monitor, nylon rope ladder, torch light and compressor blower etc alongwith the sewage cleaning truck mounted suction/jetting machine. (b) The cleaning shall be carried out with mechanized operation by means of jetting machines and the sludge sucked out with super sucker machine of required capacity and sent to storage tanks for further disposal to the authorised disposal sites. (c) Manual cleaning operation/scavenging is prohibited. (d) The unit rate shall deem to include for all material, labour (skilled/unskilled), tools and plants and requisite quantity of water for the entire operation and transportation arrangements. (e) The sludge so removed shall include the cost of dewatering also.
Desludging including dewatering of septic tank/soak well in dia/ depth and manholes above 2 mtr in depth for liquid and slurry material and removing the sludge from the tank by mechanical using hydraulic operated high pressure suction cum jetting sewer cleaning machine having jetting tank capacity of minimum 5000 ltr and suction tank capacity of 300 ltrs and 260 LPM with minimum 145 bar suction flow of 10200 LPM including skilled driver and operator and supervising Engineer including provision of water for jetting and removal of sludge/silt/liquid/mud and sand (in foul position) etc out side the MoD land/premises at any distance all as directed by Engr-in-Charge including loading, unloading digging out pit of any size in any type of soil, slurring sludge/silt/spoil/mud tec into the pit and spraying bleaching powder over the entire surface complete. Note:- (a) The service provider/contractor during the mechanized operation shall be equipped with gas monitor, nylon rope ladder, torch light and compressor blower etc along with the sewage cleaning truck mounted suction/jetting machine. (b) The cleaning shall be carried out with mechanised operation by means of jetting machines and the sludge sucked out with super sucker machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site. (c) Manual cleaning operation/scavenging is prohibited. (d) The unit rate shall deem to include for all material, labour 9skilled/unskilled) tools and plants and requisite quantity of water for the entire operation and transportation arrangements. (e) The measurement shall be included with depth of water and sludge/silt/mud.
MS framed brackets of angle iron or of flat iron with hold fasts etc as directed incl necessary welding etc complete for manholes and covers confirming to Fe-410-0 or Fe-310-0.
S&F precast polycrete plastic fibre reinforced concrete(PFRC) rectangular manhole cover (medium duty) with 60 to 75 mm thick, confirming to IS: 12592 and IS:1726, factory made area exc. 0.50 sqm but n exc. 0.75 sqm on any side complete all as specified and directed by Engr-in-charge.
S&F precast polycrete plastic fibre reinforced concrete(PFRC) circular/rectangular/square cover for gully traps (light duty) with frame of size exc. 350mm and 40 to 50 mm thick conforming to IS: 12592 and IS:1726, factory made complete all as specified and directed by Engr-in-charge.
Dismantling of cast iron or reinforced concrete drain pipe 100&75mm bore, jointed in cement motor and taking out of trenches if required
S&F Cast iron soil, waste and vent sand cast pipes in any length with or without ears, with cement joints, laid in trenches or in floors of size 100 mm bore
S&F Cast iron soil, waste and vent sand cast pipes in any length with or without ears, with cement joints, laid in trenches or in floors of size 75 mm bore
S&F Cast iron soil, waste and vent sand cast pipes in any length with or without ears, with cement joints, fixed to wall, of size 100 mm bore incl take necessary safety precaution during execution of the work up to 6 story buildings all specified and as directed.
S&F Cast iron soil, waste and vent sand cast pipes in any length with or without ears, with cement joints, fixed to wall, of size 75 mm bore incl take necessary safety precaution during execution of the work up to 6 story buildings complete all specified and as directed.
S&F Cast iron bends, tee (any radius) with ducks foot or heel rest of size 100mm bore of pipe complete all specified and as directed.
S&F Cast iron bends, tee (any radius) with ducks foot or heel rest of size 75mm bore of pipe complete all specified and as directed.
S&F PFRC circular manhole (medium duty) cover with frame of size 551 to 650 mm dia conforming to IS: 12592 and IS:1726, factory made complete all as directed and as approved by Engr-in-Charge
S&F cast iron branch piece, single ( equal or unequal) ordinary or inverted ( spigot or socket type) or with parallel branches, tee and similar items of 100 mm internal dia complete all as specified and directed.
S&F cast iron bends ( any radius) diminishing pieces or tapers ( larger bore measured) of 100 mm internal dia complete all as specified and directed.
M&L cement concrete type C-2, 1:3:6 ( 40mm graded stone aggregate ) , 75 mm thick as in plinth protection , finished cement concrete surface even & smooth without using extra cement complete all as specified and directed .
S&F stack clamps size 50mm x 5mm, flat iron and 16mm dia round iron stays, including bolt and nut and securing ends of stay to wall or roof 75mm bore pipe complete all as specified and directed.( Fixed in repair)
S&F stack clamps size 50mm x 5mm, flat iron and 16mm dia round iron stays, including bolt and nut and securing ends of stay to wall or roof 100mm bore pipe complete all as specified and directed.( Fixed in repair)
M&L cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished and reforming benching as required for 150 mm internal dia of pipes complete all specified and as directed.
M&L cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished and reforming benching as required for 200 mm internal dia of pipes complete all specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal to stores with all fittings for 15 mm bore GI tubings.
Taking up or down steel tubing and connections including cleaning for refixing or removal to stores with all fittings for 20 mm bore GI tubings.
Taking up or down steel tubing and connections including cleaning for refixing or removal to stores with all fittings for 25 mm bore GI tubings.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store with all fittings for 40 or 50 mm bore GI tubings.
S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 15 mm bore GI tubings.
S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 20 mm bore GI tubings.
S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 25 mm bore GI tubings.
S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 40 mm bore GI tubings.
Refixing old steel tubing and connections of 15 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified.
Refixing old steel tubing and connections of 20 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified.
Refixing old steel tubing and connections of 25 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified.
Refixing old steel tubing and connections of 40 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified.
S&F, in repair, gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed for 15mm dia pipe (ISI Marked)
-Ditto- as per item No-106 but for 20mm dia pipe.
-Ditto- as per item No-106 but for 25mm dia pipe.
-Ditto- as per item No-106 but for 40mm dia pipe.
Taking down eaves gutter, rain water and soil waste pipe ( any size or pattern), incl. all fitting, heads , shoes, bends, swan necks, incl cleaning for refixing or removal to store.
S & F in repair PVC (SWR) pipes single socketed, 110 mm bore in any length with rubber ring joints, fixed to walls .
S & F in repair PVC (SWR) pipes single socketed, 75 mm bore in any length with rubber ring joints, fixed to walls .
S&F PVC (SWR) bends and shoes of any radius of 110 mm bore.
S&F PVC (SWR) bends and shoes of any radius of 75 mm bore.
S&F PVC (SWR) branch piece, single (single Y) of 110 mm dia equal or unequal.
S&F PVC (SWR) branch piece, single (single Y) of 75 mm dia equal or unequal.
S&F PVC (SWR) 110 mm dia junction single (single T) equal or unequal.
S&F PVC (SWR) 75 mm dia junction single (single T) equal or unequal.
S&F PVC (SWR) 110 mm dia reducer.
S&F PVC (SWR) 110 mm dia vent cowl.
S&F PVC (SWR) 75 mm dia vent cowl.
S&F PVC (SWR) 125/110 mm dia 'P' trap
S&F PVC (SWR) 75 mm dia floor trap/nahani trap, plain with grating including jointing with solvent cement.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement.
S&F cast iron tee single or branch piece ( equal or unequal) ordinary or inverted of 75 mm dia complete all as specified.
S&F cast iron bend ( any radius) diminishing pieces or tapers ( larger bore to be measured) of 75 mm dia complete all as specified.
S&F cast iron shoes of 100 mm dia complete all as specified.
S&F cast iron shoes of 75 mm dia complete all as specified.
S&F , in repairs, cone cap cast iron cowls for 100mm bore pipe.
S&F , in repairs, cast iron cowls for 75mm bore pipe.
S&F, in repairs, 100mm dia cast iron sanitary connection- short connections pipe of length 300mm (ISI MARKED)
S&F in repairs, salt glazed stone ware gully traps square or rounded mouthed type P or S of size 150 x 150mm incl excavation earth work conc. in Beds, surrounds kerbs & CI grating etc complete.
Dismantling ceiling boarding, any description, fixed in any position with screw and removing rubbish out of MoD land complete all as complete all as directed.
M&L for Anodised aluminium snap grid frame work for false ceiling all as specified as directed
M & L for non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium frame work tiles for insulation and acoustic purposes, 6mm thick in any size on ceiling slope or flat, fixed with screw to Anodised aluminium snap grid frame work for false ceiling or with staples on snap grid all as specified as directed.
M&L for Glazed ceramic coloured walls tiles (300 x 200 mm/350x250mm/450x300mm/300x450), 6/7mm thick, for works on vertical surfaces such as skirting/dados of 1st quality , set and jointed in neat cement slurry and pointed in coloured cement to match including rendering 10mm thick on fair faces or other than fair faces of brick work in cement mortar 1:4, finished even and fair as in backing layer complete all as specified and directed.
M&L for Non skid ceramic floor tiles 7 to 8 mm thick (square/rectangular) coloured , area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, of 1st quality , set and jointed in neat cement slurry and pointed in coloured cement to match laid over screed bed or bedding layer in cement mortar 1:4, 15 mm thick for laying floor finishes complete all as specified and directed.
M&L for Non skid ceramic floor tiles 7 to 8 mm thick (square/rectangular) coloured tiles, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match laid over 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for Vitrified ceramic floor tiles light shade 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match laid over 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
S&F brass chromium plated toilet paper holder with flat recessed type stainless steel complete all as specified and directed
S&F in repairs stop valves, cast copper alloy, fancy type chromium plated of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete (fixed in repairs) .
S&F in repairs angle valve cast copper alloy, fancy type chromium plated with long shank and cup of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete (fixed in repairs) .
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm. (fixed in repairs)
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm. (fixed in repairs)
S&F for Plastic water closet seat, white , closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and jointing (fixed in repairs) complete.
S&F in repair vitreous china wash down water closet (Pedestal pattern) white complete including provision of lime concrete bedding, valveless symphonic action type PVC low level flushing cistern with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete with plastic water closet seat white closed pattern with flat bottom & cover & mild steel chromium plated or aluminium hinges device & flush pipe of polythene of low or high density of PVC 32mm dia for low level PVC cistern. (Make: HINDWARE/PARRY WARE/CERA) Ist quality.
S&F in repair water closet vitreous china squatting pan of ORISSA pattern size 580 mm X 440 mm white with integral foot rest incl setting the cast iron trap & pan into cement and sand mortar, provn of lime concrete bedding complete incl valveless symphonic action type PVC low level flushing cistern with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete
S&F in repair Classic wall mounted vitreous china wash down water closet squat pattern white incl white Hindwere concealed flush tank/cistern complete set valveless symphonic action type low level flushing cistern with inlet ball valve float & handle of 10 ltrs capacity complete with plastic water closet seat white closed pattern with flat bottom & cover & mild steel chromium plated or aluminium hinges device & flush pipe of polythene of low or high density of PVC 32mm dia for low level concealed PVC cistern. (Make: HINDWARE/PARRY WARE/CERA) Ist quality complete all as specified an as directed.
S&F in repair vitreous china wash basin white flat back size 550 x 400 mm including brass chromium plated waste coupling for WHB with long screwed and shanks and fly nuts, flanged end bedded in red lead and other end fixed, PVC waste pipe, 32mm dia ,med grade, pipe with fittings fixed in wall connected to floor trap for drain out, complete including provision of pair or bracket of angle iron 35x35x6mm duly painted with two coat of synthetic enamel paint over one coat of red oxide zinc chromate primer and embedded one end of bracket in PCC 1:2:4 type B-1 bed blocks and cutting for and pinning in ends of brackets in walls and making good all as specified.
S&F in repair vitreous china urinals, half stall type white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long bras screws pointing around urinal back in cement fixing automatic flushing cistern with brackets, flush pipe, gratings and union for discharge pipe complete all as specified.
S&F in repair vitreous china urinals, Ceramic Integrated N electronic inbuilt sensor, with screen mat lemon, urinals fixed with wall mounted for toilet white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long bras screws pointing around urinal back in cement fixing with brackets/screws flush pipe, gratings and union for discharge pipe complete all as specified. (Make: Parryware or equivalent)
S&F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 liters, low level, White with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete including taking down by dismantling the existing unserviceable cistern of any description complete all as specified and directed.
S&F brass chromium plated Health Faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repairs brass CP mixer (Central hole basin mixer) , for mixing hot & cold water screwed down for iron pipe 15 mm bore complete all as specified and directed. (fixed in repairs)
S&F in repairs PVC mirror cabinet of size 330 mm x 430 mm with openable single looking mirror with PVC inner & outer shelves of any colour, including taking down old looking mirror & wooden cupboard mirror complete (fixed in repairs) all as specified and directed.
S&F in repairs brass chromium plated soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed.(fixed in repairs)
M&L for Glass self assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.(fixed in repairs)
S&F , in repair, toughened corner glass shelf 6mm thick with brass chromium plated guard and fixing arrangements complete of size 300 mm complete all as specified and directed by Engr-in-charge .
M&L for Brass chromium plated shower rose with swivel joints, 125 mm dia with CP neck including fixing to steel pipe or union 15 mm nominal bore complete all as specified and directed. (fixed in repairs)
M&L cleaning sunken portion of slab (Bottom & sides) and providing water proofing treatment as under :- (a) Providing min 3" concave coving with PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate admixed with WPC conplast WL . Cement slurry admixed with bonding compound Nitobond AR to be used for bonding of coving with RCC member. Covering CI pipes with PCC 1:2:4 type B-0 using 20mm graded stone aggregate admixed with integral WPC conplast WL (Fosroc Chemicals India Ltd). (b) Drilling 50mm deep holes at a distance of 1m c/c and cleaned with water and air, fixing nozzles of 12mm dia on drilled holes, injecting non shrink cement slurry at a pressure of 40 psi and nipples plugged with quick setting compounds. (c) Applying 2 full coats of brush bond acrylic emulsion based elastomeric water proofing coating after the primer with a min time gap of 4-6 hrs between 1st & 2nd coat. (d) Applying 15mm thick plaster in CM 1:4 admixed with WPC conplast WL after ponding test for a period for 72 hours of sunken floor . (e)GI tubing 40 mm dia of medium grade for spout of 150 Cm long for each sunken floor. Note :- Plastered surface area shall only be measured for the purpose of payment.
M&L for lean concrete 1:4:8 type D2 using brick bats as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 75 mm thick 1:3:6 type C-1 (using 20mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for PCC 40 mm thick 1:2:4 type B-1 (using 20mm graded stone aggregate) as in flooring complete all as specified and directed.
M&L for PCC 40 mm thick 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) mixed with water proofing compound as per manufacture instruction as in sunken floor complete all as specified and directed. (Water proofing compound measured and paid separately)
S&F CI nahani trap with grating including jointing to waste pipe , dia of outlet 75mm fixed in PCC 1:2:4 type B1 all as specified and directed. (ISI Marked)
M&L for preparation of brick/concrete/existing roof treatment of roof surface by racking out joints of brick terracing tile and cleaning and washing down OR cleaning and washing down of concrete surface and make the surfaces free from dust and other contaminate and providing "Coral water seal-132 or equivalent of FOSROC water proofing treatment 3 to 5mm thick layers, trowel finished complete all as per manufacturer instruction and directed (application of treatment shall be done through application of the manufacturer) complete all as specified and directed (Make : Coral industries /FORSOC)
S&F in repair kitchen sink with drainage board made of stainless steel 1.00mm thick with plugs, washers & wastes in bedding in cement mortar to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm. ISI marked
S&F in repair kitchen sink sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified.
S&F in repair flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified.
S&F in repair 40mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified.
S&F in repair 32 mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified.
S&F plate rack as in repair of size 1000 X 750 X 250 mm stainless steel made out of 1.00 mm thick steel sheet fixed to walls incl rawl plugs, drilling etc complete incl taking down old wooden plate rack
S&F in repairs brass chromium plated sink mixer with regular swimming spouts suitable for kitchen ( wall mounted model with connecting legs/wall flanges) complete all as specified.
S&F in repair bib taps fancy type chromium plated 15mm bore dia of pipe with crutch or butterfly handle complete all as specified and as directed.
S&F in repair single level exposed shower mixer with provision of connection to exposed shower pipe with connecting legs and wall flange complete as wall mixer for mixing hot and cold water complete all as specified and directed of brass chromium plated all as specified and directed.
Dismantling of old PVC water tank of capacity exc. 250 & n. exc. 500 ltrs incl making connection with fitting for inlet & outlet pipe.
As per item no 177 above here in before but capacity exc. 500 & n. exc. 1000 ltrs incl making connection with fitting for inlet & outlet pipe.
As per item no 177 but capacity exc. 1000 & n. exc. 2000 ltrs incl making connection with fitting for inlet & outlet pipe.
S&F in repair rotational moulded polythene water storage tanks in double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 ltrs incl making connection with fitting for inlet & outlet pipe.
As per item no 180 above but capacity 1000 ltrs incl making connection with fitting for inlet & outlet pipe.
As per item no 180 above but capacity 2000 ltrs incl making connection with fitting for inlet & outlet pipe.
M&L for coloured granite( of any type and coloured) 18-20 mm thick table rubbed and polished as in Floor, cooking platform, and the like machine cut laid over and including 15 mm thick screed bed in CM 1:4, laid and jointed with grey cement slurry and incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade including cutting, making hole of 20 mm dia for gas pipe at suitable location as directed at site and polishing complete.
..Ditto .. All as per item No 183 above but as in vertical surfaces such as dado/skirting laid over and including rendering 10 mm thick in CM 1:4 jointed with grey cement slurry and incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including cutting and polishing complete.
M&L rounding to edges of stone slabs one edge such as steps, cooking platforms and other similar situations complete all as specified.
S&F, in repairs, brass chromium plated towel rail 600mm long D type fixed to wall with and including Chromium plated brass screws and wooden/plastic cleats.(Minimum weight 190gms)
S&F in repair vitreous china wash basin white oval type size 600 x 480 mm white in colour, fitted in counter platform of granite stone of 18-20 mm thick, of approved colour, area of granite slab exceeding 0.50 Sqm but not exceeding 1.00 Sq. m in single piece, corners/edges shall be rounded off, including provision of brass chromium plated waste coupling for WHB with long screwed and shanks and fly nuts, flanged end bedded in red lead and other end fixed, PVC waste pipe, 32mm dia ,med grade, pipe with fittings fixed in wall connected to floor trap for drain out, complete including provision of pair or bracket of angle iron 35x35x6mm duly painted with two coat of synthetic enamel paint over one coat of red oxide zinc chromate primer and embedded one end of bracket in PCC 1:2:4 type B-1 bed blocks and cutting for and pinning in ends of brackets in walls and making good all as specified.
S&F 6 mm thick mirror of size exc. 0.50 sqm but n.ec 4 sqm each fixed with 3mm PVC plastic sheet including stainless steel rounded bolts, rounded decorated edges of glass all as specified and as specified. (Make - Modi guard)
Cleaning and removing all scales and dirt etc from existing tanks and from mouths of circulating pipes etc for including 250 litres but not exceeding 500 Litres capacity of tanks complete all as specified and as directed.
Cleaning and removing all scales and dirt etc from existing tanks and from mouths of circulating pipes etc for exceeding 500 litres but n.exc. 1000 Litres capacity of tanks complete all as specified and as directed.
Cleaning and removing all scales and dirt etc from existing tanks and from mouths of circulating pipes etc for exceeding 1000 litres but n.exc. 2000 Litres capacity of tanks complete all as specified and as directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all type of fittings, fixtures for outer diameter 20 mm bore complete all as specified.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all type of fittings, fixtures for outer diameter 25 mm bore complete all as specified.
Safe for ball valve CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings for outer diameter 20 mm bore complete all as specified.
Safe for ball valve CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings for outer diameter 25 mm bore complete all as specified.
Safe for water tank cover including necessary fittings, nuts and bolts complete all as specified.
S&F in repair PTMT ball valves high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20mm dia.
M&L for manual Sealing of traps, WCs (manually) with neat cement paste after removal of water from it, to prevent or make up the leakage including cementing in cement mortar (1:3) from inside and outside both & refixing grating, plasters etc complete all as directed and as specified.
Ex Serviceman Enterprises
M/S Sunil Steel Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .