Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical C 6 5 RATAN TOWER FIRST FLOOR YOJNA 06 JAGRAITI VIHAR OPP MEDICAL COLLEAGE GARH ROAD MEERUT U P 250004 MEERUT UTTAR PRADESH 250004 | MEERUT | UTTAR PRADESH | 250004 | Accepted-Technical All document uploaded |
| 2 | Accepted-Technical | Accepted-Technical All document uploaded |
| 3 | Accepted-Technical NA | Accepted-Technical All document uploaded |
| 4 | Rejected-Technical | Rejected-Technical AUTRIZATION NOT UPLOADED |
| 5 | Rejected-Technical | Rejected-Technical AFFIDIVATE NOT SIGNED |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
28 Jan 2026, 5:00 pmClosed
Ex Engineer
EX ENGINEER OFFICE AT SPORTS HOUSE MA STADIUM
Construction of playground near Floriculture Garden Bagh-e-Bhour, Bhour Camp Satwari
2026_SPORT_300889_1
E NIT NO 73 OF 2025-26 DATED 19.01.2026
Open Tender
Civil Works
Percentage
365 days
BHAGE BHOUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,000
Ex Engineer CDJ
₹3.9 L
EX ENGINEER OFFICE AT SPORTS HOUSE MA STADIUM
22 Jun 2026
19 Jan 2026
29 Jan 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
22 Jan 2026
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. 100 sqm .
filling of good earth including diging, loading, unloading, royality, carriage & spreading in proper lines and grades and consolidation with power road roller complete.
Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge:1:3:6 mix
Dismantling steel work in built up sections in angles, tees, flats andchannels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead.
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil complete job.
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kind of Soil
Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)complete job.
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level using 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns complete job.
Centering and shuttering including strutting, propping etc. and removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form work for: Edges of slabs and breaks in floors and walls under 20 cm wide
Centering and shuttering including strutting, propping etc. and removal of form work for: Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge Made of G.I. wire of dia 4 mm complete job.
Applying priming coat With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work complete job.
Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m
12mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
Extra for pre finished nosing in treads of steps of kota stone/ sand stone slab.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2
Painting on G.S sheets with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer.
Providing and fixing of flags of Sating cloth of different colours including sewing and printing of logo. Complete job as per direction of engineer Incharge
Providing and fixing ACP main board 3mm thickness on 1 x 1 inch tubular frame with writing of Name of stadium etc as per direction of engineer incharge
40mm thick marble chips flooring rubbed, under layer 28mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 7 mm to 10mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix :3 marble chips) by volume including cement slurry and curing complete : Ordinary cement without any pigment.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing of cricket prctice pitch net as per direction of engineer in charge
Providing & fixing PVC Flexi Wickets 1 No. set of 3 wickets, 1 No stump on other side complete as per direction of engineer incharge
Treatment of soil under existing floors using chemical emulsion (Chlorophriphos/Lindane E.C. 20% with 1% concentration) @ one litre per hole, 300mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floor:
Consolidation of subgrade with power road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the subgrade
Providing, Laying, spreading and compacting RBM as per specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, watering and compacting to the required density
P/L and compacting stone agrregates of different sizes to form contour and elevation to the desired level as per the Drawing and instruction of Engineer Iincharge (size 40 mm /20 mm/10mm ) down black stone aggregate up to a depth of 300mm from below primary backing incl all carriage. Layers of stone to be rolled as per desired slope and compaction using 8-10 tonnes Road roller over open area & pitch roller over areas with drainage pipes.
Supply and installation of artificial UV resistanat polyethylene synthetic grass with rigid monofilment yarn, minimum 40mm pile height and 1250g/sqm pile weight with total carpet weight not less than 2500g/sqm and infiill in the ratio of 2:1 with sand(size of sand 0.2mm-1.0mm) 15mm (minimum)height and Rubber 8mm(minimum)height infill weight not less than 2.25kg/sft .The stitch rate per meter should be minimum of 285 All line marking shall be white, unless in the drawings. line marking shall be sitched 'tufted' material (painted lines are not acceptable) the carpet should be laid as per the manufacturers manual incl. All applicable taxes, Lavies, Octoria, transportation loading/unloading complete. (Including Maintenace of 3 years by way of brushing and adding infill as and when required)
Providing of Fixing Height Adjustable Fixed Volley Poles with Net and Anteena
Supply and laying of PVC insulated and PVC sheathed / xlpe aluminium power cable of 1.1 KV grade of following sizes on surface / direct in ground including sand cushioning protective covering and refilling the trench as required as per direction of Engineer Incharge 16 sq. mm 2 core
Supply and laying of PVC insulated unsheathed bright annealed bare copper industrial cable for voltage grade upto 1100V as per IS694:1990 3 core 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door SPN MCBDB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 32 Amp
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 63 Amp
Installation, Testing and commissioning IP 67 Flood lights 200 watt minimum Luminous flux of luminaire 120 Lm/w, Colour temperature of 5700K, Neutral white, CRI > 80, 50,000 operating hours with PCLens and necessary wire for connection and other accessories required for fixing lights on existing Poles. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty.
carriage of sand for a distance 20km by mt
carriage of Brick for a distance 25 km by mt
stage.html
html • 0.04 MB
tech_eval.pdf
cancelled_1.pdf
pdf • 0.44 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.91 MB
BOQ_976103.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .