Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.0 CrAccepted-AOC | ₹56.0 Cr | L1 | Accepted-AOC aoc |
| 2 | L2₹56.5 CrRejected-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹56.5 Cr | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹56.7 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹56.7 Cr | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹56.9 CrRejected-Finance | ₹56.9 Cr | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹56.9 CrRejected-Finance | ₹56.9 Cr | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹63.9 Cr
EMD Value
₹15 L
Closing Date
5 Sept 2024, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM
PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR SAILORS MCPOs CPOs AT NAVAL STATION BHEEMUNIPATNAM
2024_MES_655478_1
85432
Open Tender
Civil Works
790 days
VISAKHAPATNAM
AS PER NIT
11 documents required · 11 mandatory
₹3,000
GARRISON ENGINEER P NAVY KALINGA
₹15 L
VISAKHAPATNAM
29 Nov 2024
22 May 2024
12 Sept 2024
22 May 2024
5 Sept 2024
26 Jul 2024
22 May 2024 - 7 Jul 2024
12 Jun 2024
Amount
Schedule "A" Part – I (BUILDINGS & STRUCTURES)
Structural Design and Construction of one block for Sailors (MCPOs/CPOs) married accommodation (G+11) with RCC framed structure complete all as specified and as shown on drawings.
Structural Design and Construction of car parking shed (For 12 cars) of RCC framed structure complete all as specified and as shown drawings
Structural Design and Construction of pump house of RCC framed structure complete all as specified and as shown drawings
Structural Design and Construction of under ground sump of capacity 1,40,000 litres complete all as specified and as shown on drawings. .
Structural Design and Construction of under ground sump of capacity 75,000 litres complete all as specified and as shown on drawings.
Construction of RCC Septic tank for 300 users complete all as specified and as shown on drawing No.TD Drg No 389 (S) Sheet No. 1/3.
Construction of RCC filter bed with dispension trench for 300 users complete all as specified and as shown on drawing No.TD Drg No 389 (S) Sheet Nos 2/3 & 3/3 (2 Nos in use & 2 Nos in stand by).
Schedule "A" Part – II to Schedule "A" Part – XVII: NOTE: Schedule "A" Part – II to Part – XVII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "SITE CLEARANCE & AREA DEVELOPMENT/ EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "ROADS, PATH, HARD STANDING, CULVERTS", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "RETAINING WALL", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "FIRE ALARM", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "PVC CONDUIT", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "DG SET", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "SOLAR WATER HEATER", as listed in Schedule "A" Part – XVI
Lumpsum price worked out by the contractor for "LIFT", as listed in Schedule "A" Part – XVII
Schedule "A" Part - XVIII: (Miscellaneous Items) (Internal Electrification, Internal water supply, Sewage Disposal , External Water Supply, External Electrification, Road, Path, Hard standing, Culvert, Fire alarm system, Fire fighting system, lightening protection, PVC Conduit, Aviation Light, DG Set, Solar Water Heater, Lift )
Internal Electrification
S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc complete all as specified and as directed.
Internal Water Supply
S&F digital type water meter (electromagnetic type), flanged tye, MS body for smart metering of high accuracy, robust design, IP 67 enclosure, for residentail water supply, fixing to 150 mm dia GI pipe line with necessary nuts, bolts and washers and including connecting FRLS PVC insulated 3 core, PVC sheathed unarmourded copper wire through 20 mm dia GI pipe light grade complete as per site requirement all as specified and as directed
S&F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S&F 15 mm health faucet, chromium plated, fancy type with steel flexible pipe 1.5m long complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S&F brass IVC angular stop cock including connection complete all as per cat No. FLR-CHR-5053N of make Jaquar complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S&F Angle stop valve, chromium plated, fancy type, long shank and cup (concealed type), screwed down, high pressure screwed and fixed, suitable for 16mm outer dia CPVC pipes with and including chromium plated urinal water droper complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
SEWAGE DISPOSAL
M&L for pre cast SFRC manhole cover slabs for size 1.80x1.80m, and opening size of cover slab 600x600x70mm thick , MD-10 Grade, conforming to IS 12592-2002 complete all as specified and directed.
M&L pre cast SFRC manhole cover slabs for size 2.10x2.10m, and opening size of cover slab 600x600x70mm thick , MD-10 Grade, conforming to IS 12592-2002 complete all as specified and directed.
External Water Supply
M&L for laying of ductile iron pipe 100 mm dia, with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS -8329 including provision of special such as tees, elbow, bends reducers tapper pieces ( measure seperately) including testing and commissioning complete all as specified and directed.
M&Lfor brick masonary valve chamber of the size 1050x1050x1050 mm including necessary excavation, PCC foundation, brick work, plastering and MS Sheet cover of 6 mm thick including locking arrangement with two coats of red oxide primer and one coat of synthetic enamel paint of approved colour all as directed .
S&F CI foot valve flanged type of size 100 mm Complete all as specified and as directed
Supply and install energy efficient centrifugal pump set of minimum head 46 m and discharge is 416 LPM with motor complete electric driven supplied and installed complete inclusive of star delta starter of appropriate rating as recommended by OEM. PCC foundation for pump set and starter and angle iron base of suitable size for installation of the pump set also deemed to inclusive as recommended by OEM and suitable size of Copper cable for connection of pump (Starter should be fixed on panel)
S&F heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10kg/Sqcm comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank 150 Ltrs capacity, complete with mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV alogwith control panel for dosing Pump suitable for Model SSAPS/cdspt/25 made of powder coated MS Fabricated box consistting of LED indicator, digital volt meter, Amp meter, single phase prreventor, High Voltage, low Voltage protection. Make : Sathya SAI AQUA Pura SERVICES. Model No SSAPS/CDSPT/25/ST
External Electrification
Supply, fabricated, install test and commissioning LT Out door control panel weather proof, dust/vermin proof made out of 3.15 mm thick CRCA sheet double opeanable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system, 415 V 50 Hz, AC Supply with bus bar aluminium of rating 1000 Amps capacity including with PVC heat shrinkable sleeves RYB colours for phases identification, conforming to IP-62, and fixed on raised PCC platform with PCC 1:2:4 type B1 (20 mm graded aggregated) raised base with control wiring and compressing cable steel gland brass, Aluminium lugs of suitable size etc, and compressing the follwing items conforming to CPRI approved manufacturer complete all as specified and directed.
Supply, fabricate, install, test and commissioning LT indoor control panel weather proof dust/vermin proof, front and back openable made out of 3.15 mm thick CRCA sheet double openable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system, 415 V, 50 Hz AC Supply with bus bar aluminium 200 Amps capacity including with PVC heat shrinkable sleeves RYB colours for phases identification, conforming to IP-54, and fixed on raised PCC platform with PCC 1:2:4 type B-1 (20 mm graded aggregate) raised base with control wiring and compressing cable gland brass, aluminium lugs etc and compressing the following items conforming to CPRI approved manufactures:-
(Pump House Panel) (a) MCCB 4 Pole, 100 Amps, 25 kA - 01 (for incoming). (b) MCCB 3 Pole 32 Amps, 10 kA - 03 (for out going to Pumps for water supply and fire fighting) (c) 3 Phase multifunction energy meter (Voltage 0-500 V, Ampere 1-125A including CT's and PT's. Single phase preventer,Digital voltmeter,3LED phase indicator lamp (d) Electrolyte aluminium busbars, PVC colour sleeved 200 Amps capacity TP. (e) Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled red & white with words 'DANGER' 415 V Written in English, Hindi & local language, compulsory figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20x15 cm Size - 01 No. f) Provision for installing star delta starter -02 Nos (starter included with the pump set)
S&F HOT Junction box with front cover of size 250x250x100 mm (FRP) for street light pole with locking arrangement with IP 66 protection with 32 Amps 4 way heavy duty terminal block with 10 A MCB SP with two steel bracket to fix with pole and aluminium bus bar of rating 100 Amps complete all as specified and directed
M&L for MCCB of 4 pole 100 Amps ,415V,25KA with spreader terminals along with MS encloser for lift room main supply all as specified and directed.
M&L for MCCB of 4 pole 63 Amps,415V,16KA along with MS encloser for lift main supply all as specified and directed.
M&L for MCCB of 4 pole 200 Amps,415V,25KA along with MS encloser for busbar runing system switch gear all as specified and directed.
S&F timeline distrubution board 32A, 3 pole, 230 Volts Digital time switch and connector complete all as specified and directed.
ROADS, PATH, HARD STANDING, CULVERTS
M&L for Painting lines, dashes, arrows, letters, etc. on roads surface with hot applied retro reflective thermoplastic paint (min 2.5 mm thick) confirming to MORTH (clause 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 degree C , including cleaning & drying the road surfaces to ensure dust, oil, grease & moisture free surface before applying paint complete all as specified and directed.
S&F dual directional reflective cat eye (Road Glow Stud) of impact resistant ABS plastic 100x90x16mm, of ultra violet resistant yellow colour, having micro prismatic/cube corner reflectors suitable for fixing with epoxy/bitumen adhesive as per manufacturer's specification/instructions complete all as specified and as directed by the Engineer-in-Charge. Note: Appropriate epoxy adhesive on the road surface shall be provided as per manufactures specifications/ instructions before fixing the cat eye and the same is deemed to be included in the unit rate quoted.
FIRE FIGHTING SYSTEM/ FIRE ALARM SYSTEM
S&F 2 core 1.5 Sqmm FRLS armoured copper cable as per IS-1554 to wall/roof/false ceiling/floors all as specifed and directed
S&F LED Exit light double sided with battery backup to 2 hrs of operating Voltage 230 V, 50 Hz complete with all as specified and as directed.
S&F 200 mm dia foot valve conforming to IS 4038, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
S&F 100 mm dia foot valve conforming to IS 4038, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
S & F First Aid hose reel with MS construction spray painted in post office Red, conforming to IS 884 with up-to-date amendments complete with the following required: (a) 20 M long 25 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type 2 as per IS: 12585. (b) 20 mm (Nominal internal) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipment’s on wall. (d) Connection from riser with 25 mm dia stop valve (Gun metal) & MS Pipe.
M&L for masonry valve chamber of size 1050x1050x1050 mm (interanl dimensions) comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM 1:6 plastring internal surface 15 mm tick in CM 1:4, PCC 1:3:6 type B1 couping 50x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
S&F fire extinguishers of capacity 6.0 kg dry chemical powder (ABC) type consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and as directed.
S&F fire extinguishers of capacity 4.5 kg CO2 type (light weight squeeze grip type) consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and as directed.
S&F fire extinguishers of capacity 9.0 ltrs. water stored pressure type consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and as directed.
S&F fire extinguishers of capacity 9 Ltr mechanical foam type consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge complete all as specified and as directed.
S&F Fire Buckets complete all as specified and as directed.
PVC CONDUIT
S&F TV co-axial socket 1 module complete with all accessories all as directed
S&F factory fabricated GI Metal flush boxes suitable for 1-2 module complete all as specified and directed.
S&F of GI junction boxes of size 150x100x60 mm with cover plate Complete all as directed.
Aviation Light
S&F Aviation obstruction light LED type fitment-less bulb with 10 Watt bulb complete including standard fixing arrangement all as specified and directed.
S&F Cable PVC insulated LT 1100V grade with copper conductor of size 3core 2.5sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable clamps spacers bolts nuts etc all as specified and directed.
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit junction boxes of size 205x255x112mm for cable entry and exit combi climate cable glands of IP 66/IP67 for cable entry and grommets IP 65 for conduit of cable exit with MCB SP 6Amps, 10 kA, C curve over load and short circuit protection terminals as PVC connector heavy duty 32Amps, 4way for cable with necessary fixing arrangements with cable glands etc all as specified and directed.
S&F timer switches 250V single phase of 20 Amps rating with contactor fitted inside steel enclosure and suitable nut, bolts & washers for fixing complete all as specified and as directed.
DG SET
Supply, installation, testing and commissioning of silent Diesel Engine Generating set including accoustic enclosure as per CPCB norms-4, 415 Volts 100 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator with AMF panel of suitable rating, including accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS:10002,ISO-3046, BS-5514 and Alternator as per IS:4774, BS EN 60034-1 with the following accessories including necessary suitable size of PCC foundation,GI pipe for laying of cable,etc and Retroift emmision control system for 100 kVA DG set as per the latest CPCB norms all as per manufacturers instructions,complete all as specified and directed.
(i) Insulation class & Temparature rise class-H (ii) Excitation : self excited (iii) Regulation performance : The Voltage is kept constant with +/- 1% manual Voltage adjustment with in +/- 5% (b) Diesel Engine : Adequate capacity of Disesel engine as accepted by the accepting officer based on manufacturers technical details liquid cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant / ISI/BS 5514 with an overload capacity of 10% for half an hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- (i) Fly wheel with housing (ii) cooling system : Moulded radiator with fan & belts. (iii) Cooling water pump : centrifugal type belt driven
(iv) Exhaust system : Exhaust system complete with exhaust piping of suitable dia with MS pipe light grade upto & outside and 1 m away from the enclosure covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for sale exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charge type Exhaust manifold Silencer : Residual type (v) Fuel system : Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1 % speed / frequency regulations, fuel filters, fuel hoses. (vi) Lub oil system :- (a) Lubricating oil filter, (b) Lubricating oil pump (vii) Air Intake system :- (a) Air cleaner dry type, (viii) Governor : Electronic Governor (ix) Starting system : Electric self starter with maintenance free battery including battery charging alternator.
x) Batteries : Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key switch Handing and operation : Sailent features of accessories shall be as under : (aa) Radiator with Blower fan (ab) Corrosion inhibitor coolant (ac) Paper element filters for fuel, lub oil and by pass (ad) Electronic governor controlled direct fuel injection system (ae) Fly wheel housing and fly wheel (xi) Generator Monitoring Panel : Comprising of all standard item as mentioned under this schedule / asper standard practice ignition key switch and start/ stop arrangement, indications for Engine parameters hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temparature indicator, battary volt display. (xii) Safety controls : Engine low lube oil pressure high water temparature and over speeding of engine
(xiii) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories : AVM pads built or separtely mounted to manufacturer base frames. (xv) Base frame : Made out of ISMC 250 of sturdy design made of MS channel or as recommended by manufacturer. (C) AMF panel : Factory made indoor type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 volts 3 phase 4 wire A C 50 Hz, including powder coated, aluminum bus bar of one and half times the rated load of 100 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses name plates consisting of 4 pole MCCBs and contactors and relays of capacity as recommended by the manufacturer, detachable cable gland plates all controls, indicators and
(xv) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set green. The base frame should be painted with epoxy based black shade (xvi) Rubber matting of LV grade 19 mm thick of suitable size, chequered type, ISI marked shall be laid in front of control panel. (xvii) Testing : The DG set shall be tested for a period not less than 12 hours continuously out of which at least 1/2 hour on No Load and 2 Hrs of 25% load, 02 hours on 50% and 2.30 Hrs on 75 % of rated full load, 04 hours on rated full load and 01 hours on 110% rated full load. Necessary load shall be given on connected load. If the required full load for testing purpose is not available at the site, artificial load has to be arranged by the contractor for the testing. All instruments, consumable stores like engine oil, grease required for carrying out the tests including manpower shall be provided by the contractor. Contractor shall arrange DHPP for testing of DG set. Unit rate quoted shall deemed to include cost of the same.
Supply, fabricate, install, test and commissioning LT Outdoor control panel weather proof dust/vermin proof, made out of 3.15 mm thick CRCA sheet double openable door with angle iron frame and locking arrangement, including bus bar suitable for 3 phase 4 wire system, 415 V, 50 Hz AC Supply with bus bar aluminium 300 Amps capacity including with PVC sleeves/taps RYB colours for phases identification, conforming to IP-54, and fixed on raised PCC platform with PCC 1:2:4 type B-1 (20 mm graded aggregate) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc and compressing the following items conforming to CPRI approved manufactures:-
(a) MCCB 4 Pole, 160 Amps, 36 kA - 01 (for incoming). (b) MCCB 4 Pole 63 Amps, 25 kA -04 (for out going for lift and booster pump). (c) MCCB 3 Pole 32 Amps 25 kA - 02 Nos (For Water supply pump house) (d) LED Type Phase indicator with controlling fuses for RYB- 01 Set. (e) 3 Phase multifunction energy meter (Voltage 0-500 V, Ampere 1-125A including CT's and PT's. (f) Electrolyte aluminium busbars, PVC colour sleeved 300 Amps capacity TP. (g) Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled red & white with words 'DANGER' 415 V Written in English, Hindi & local language, compulsory figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 20x15 cm Size - 01 No. (h) ON load change over switch.
SOLAR WATER HEATER
S&F 20 mm dia froged bronze pressure reduce valve all as specified and directed .
SOLAR POWER FOR COMMON AREA
S & F sheet metal enclosure for DBs with MCB of 2 way for 240 V all as specified and directed .
S & F SPN MCB of 16A ‘C’ curve with 10 KA all as specified and directed.
M & L for sub main wiring for circuit along with earth wire FRLSH with 2 x 1.5 Sq.mm and 1 x 1.5 Sq.mm for earth wire including PVC conduit concealed PVC insulated copper conductor, single core all as specified and directed (for connected from solar system to each floor)
S & F all in one comprising of high efficiency LED 120W efficient mono crystalline solar panel, new age lithium ferro phosphate battery, silicon encapsulated high efficiency MPPT charge controller unique designed for better dissipation & strategically placed perforation allowing natural air passive circulation within & into the housing for improved thermal management of internal components, including mounting bracket, in-built PIR motion sensor of 15 watt, LEP battery 12.8V/18AH for 08-10 hours backup, solar panel 30WP mono crystalline all as specified and directed with 5 years warranty (For bldg light) Make : Crompton of cat CSADSMP15CDL-NC or Bajaj or equivalent.
(a) Fire man switch (b) Automatic rescue divide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funning the lift with full load. c) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting in false ceiling . e) One Sleek circular PVC heavy duty fan in false ceiling. Make for (c) & (d) : Philips / Bajaj / Crompton Greaves. f) Aluminum chequered plate (3 mm thick) as flooring joint in chequered plate should not more than one and top covering with PVC flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc., (overload protecting / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conforming to IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish.
l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Specification plate with complete details . o) Continuous earthling for machine and equipments. p) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. q) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breaks, control panel, locks, governor, car operational panel, power, control and trailing cables complete. r) Full length display indicator panel. s) Main drives and control shall be of latest, high effective and low power consumption. t) Suitable phase reversal relay shall be provided on the controller to protect lift/ equipment against phase reversal, phase failure and low voltage. u) Stainless steel front opening type landing door & car door with small opening for vision of size 200x800 mm with toughened glass not less than 8mm thick. Make of Toughened Glass : Safe / Saint Goblin Glass / Modiguard float glass / Kesar / Aashi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. v) Three-way Intercom connectivity i.e. Ground floor, security post, car cabin and machine room. w) Brail push button to be provided in the lift car.
All as per Serial Item No.75 above, but lift suitable for 13 passengers (884 Kgs)
SCHEDULE 'A' PART-XIX PHASE -IV OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 75 AND 76 DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
Outsourcing of electrically operated lifts by providing services of one lift operator (Semi Skilled) (Metric/SSC qualified with 2 to 3 years of relevant experience) for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XX PHASE -V OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 75 AND 76 DURING SECOND YEAR OF DEFECT LIABILTY PERIOD.
Outsourcing of electrically operated lifts by providing services of one lift operator (Semi Skilled) (Metric/SSC qualified with 2 to 3 years of relevant experience) for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XXI PHASE -VI COMPREHENSIVE MAINTENANCE AND OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 75 AND 76 DURING FIRST YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Outsourcing of electrically operated lifts by providing services of one lift operator (Semi Skilled) (Metric/SSC qualified with 2 to 3 years of relevant experience) for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year after expiry of Defect liability period complete all as specified and as directed.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+11 upper floors all as mentioned vide SI No. 76 of BOQ during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+11 upper floors all as mentioned vide SI No. 75 of BOQ during 1st year after expiry of defects liability period all as specified and directed
SCHEDULE 'A' PART-XXII PHASE -VII COMPREHENSIVE MAINTENANCE AND OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 75 AND 76 DURING SECOND YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Outsourcing of electrically operated lifts by providing services of one lift operator (Semi Skilled) (Metric/SSC qualified with 2 to 3 years of relevant experience) for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year after expiry of Defect liability period complete all as specified and as directed.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+11 upper floors all as mentioned vide SI No. 76 of BOQ second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+11 upper floors all as mentioned vide SI No. 75 of BOQ second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XXIII PHASE -VIII COMPREHENSIVE MAINTENANCE AND OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 75 AND 76 DURING THIRD YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Outsourcing of electrically operated lifts by providing services of one lift operator (Semi Skilled) (Metric/SSC qualified with 2 to 3 years of relevant experience) for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 3rd year after expiry of Defect liability period complete all as specified and as directed.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+11 upper floors all as mentioned vide SI No. 76 of BOQ third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+11 upper floors all as mentioned vide SI No.75 of BOQ third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Notes for manning: (i) The lift shall be operated daily in two shifts as directed.. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
Note for Comprehensive maintenance:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3086281)
SOOD ASSOCIATES PVT LTD (BID ID -3085685)
MUKUL BUILDERS LLP (BID ID -3085630)
K KUMAR RAJA PROJECTS P LIMITED (BID ID -3086425)
GOPAL TEKNOCON PRIVATE LIMITED (BID ID -3081305)
Aalaya Engineering Project Private Limited (BID ID -3078706)
Indus Projects Private Limited (BID ID -3081636)
TALWADEKARS INDIA BUILDCON (BID ID -3087308)
SRICO PROJECTS PVT LTD (BID ID -3087644)
jd constructions (BID ID -3086034)
RKEC Projects Limited (BID ID -3086436)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid