Loading…
Loading…
Tender Value
₹5.3 L
EMD Value
₹5,900
Closing Date
5 Aug 2026, 5:00 pm4d left
Divisional Officer
ROADS and BUILDINGS DIVISION NO. II, SAMBALPUR
SITC of Fire Fighting, Conventional Fire Alarm, Emergency Evacuation and Signage System at RDC Building VIMSAR, Burla Buildings.
2026_EICCL_137189_1
SE/R and B/SBP II/02/2026-27
National Competitive Bid
Electrical Works
Percentage
60 days
Sambalpur
2 documents required · 2 mandatory
₹4,000
₹5,900
Yes
27 Jul 2026
27 Jul 2026
6 Aug 2026
27 Jul 2026
5 Aug 2026
27 Jul 2026
27 Jul 2026 - 4 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Installing, Testing and commissioning of electrical motor driven booster pump of Monoblock type capable to deliver 450LPM at 35MWC. The pump shall be coupled to TEFC motor of suitable HP with speed of 2900RPM and complete set shall mounted on common base frame as per direction of engineer in charge.Make-Kirloskar/Wilo/Ksb. | 1 | nos | 58,570 | ₹58,570 |
| 2 | Control panel for fire pumps for auto action :Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge | 1 | nos | 31,440 | ₹31,440 |
| 3 | 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS, PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havels/KEI.3.5C x 16 mmsq | 30 | rm | 480 | ₹14,400 |
| 4 | 2 C x 1.5 mmsq | 30 | rm | 141 | ₹4,230 |
| 5 | G.I. earthing strip of size 25x3 mm shall be run for PUMPS to panel. | 30 | rm | 178 | ₹5,340 |
| 6 | Supplying, Installing, Testing and commissioning of waffer type C.I. Non-return valves as per with required flanges, nuts, bolts and gaskets etc. complete of size 100 mm nominal dia.as per direction of engineer in charge.Make-Zoloto/Leader/Audco | 2 | nos | 6,750 | ₹13,500 |
| 7 | Supplying, Installing, Testing and commissioning of CI butterfly valves (PN 10) as per BS 5155 slim seal standard lever operated type with required flanges, nuts, bolts etc. complete of size 100 mm nominal dia.Make-Zoloto/Leader/Audco | 2 | nos | 5,330 | ₹10,660 |
| 8 | Providing, installing and commissioning C.I. flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete..Make-Zoloto/Audco/Leader/Kartar.100 mm | 1 | nos | 9,870 | ₹9,870 |
| 9 | SITC of Gun metal chrome finished Ball valves with fittings of screwed end type.as per direction of engineer in charge of size 15 mm dia. | 2 | nos | 780 | ₹1,560 |
| 10 | Supply and installaion of pressure switches of suitable range for pump sets.as per direction of engineer in chargeMake-Indfos/Grandfos. | 1 | set | 3,267 | ₹3,267 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 1.54 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_603464.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].