| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.1 LAccepted-AOC 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹33.7 L+₹80,561 (2.45%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹35.9 L+₹3.0 L (9.09%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹37.5 L+₹4.6 L (13.9%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹40.4 L+₹7.5 L (22.7%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
26 Nov 2020, 6:00 pmClosed
HQ CWE Agra
112 Taj Road Agra Cantt
REPAIR / REPLACEMENT OF WORN OUT INTERNAL ELECTRICAL WIRING, FITTING AND FIXTURE IN JCO/ORS MD ACCN, RRC, SLI, MH, 114 TA 431(I) ASC, MES STAFF MD ACCN AND OLD SF AREA AT FATEHGARH CANTT
2020_MES_390855_1
86065/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted in Class D category b(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE Fatehgarh
₹97,000
Yes
22 Feb 2021
29 Oct 2020
2 Dec 2020
29 Oct 2020
26 Nov 2020
12 Nov 2020
29 Oct 2020 - 5 Nov 2020
Amount
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and including taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders etc but excluding light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. Note :- Old Serviceable fittings shall be reused under item No.10,12,13 & 18 here in after)
Taking down carefully sub main wiring / service connections of any size including batten / conduit and making good the disturbed surfaces of wall / floor complete all as specified and directed.
M&L for concealed point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed, FRLS copper conductor multistranded cable in and including concealed PVC rigid conduit 20 mm dia 1.2 mm thick ISI marked with complete accessories including provision of PVC insulated cable of 1.5 sqmm size unsheathed copper conductor as earth wire through on the same conduit to common earth and connected to earth dolly including pressed steel galvanised terminal box of 1.5 mm thick of required size sunk type with top cover and 3 mm thick plastic laminated hylam sheet of required size ISI marked for mounting switches, sockets, regulators etc complete all as specified for the following :- One light / fan / exhaust fan point controlled by one switch 5 Amp SP one way.
All as per Srl item No. 3 here in above but point wiring for 3 pin / 5 pin switch socket combination point, 5 Amps on independent board complete all as specified and directed.
All as per Srl item No 3 here in above but point wiring for 3 pin / 5 pin switch socket combination point, 5 Amps on same board.omplete all as specified and directed.
All as per Srl item No 3 here in above but point wiring for one light point controlled by two Nos of two way switches, 5 Amps SP complete all as specified and directed.
All as per Srl item No 3 here in above but point wiring for one bell point controlled by one bell push switch, 5 Amps complete all as specified and directed.
All as per Srl item No 03 here in above but point wiring for one six pin socket combination, 15 Amps (independent) controlled by one switch with using 2.5 Sqmm FRLS (nominal area) multistranded copper conductor complete all as specified and directed. Notes for item 3 to item 8 here in below : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
Supplying & fixing for piano switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed.
Fixing only for piano switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified and directed. Note :- Old serviceable switch obtained from item No.1 shall be reused.
Supplying & fixing for switch socket combination 2 in 1, 5 pin and 5 Amp flush type complete all as specified and directed.
Fixing only for switch socket combination 2 in 1, 5 pin and 5 Amp flush type complete all as specified and directed. Note :- Old Serviceable switch socket obtained from item No.1 shall be reused
Fixing only for switch socket combination 5 in 1, 5 pin and 15 Amp flush type complete all as specified and directed. Note :- Old Serviceable switch socket obtained from item No.1 shall be reused
Supplying & fixing bell push, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for bell (Ding dong), 230 volts AC circuit complete all as specified & directed.
Supplying & fixing for lamp holder PVC / Polycarbonate type, insulated body with back plate suitable for batten fitting complete all as specified & directed.
Supply and fixing rotory 5 stepped type electronic fan regulator 100 watt 230 volts complete all as specified & directed.
Fixing only fan regulator already as obtained from item No.1 connection completewith all accessories and down rod complete all as specified and directed. Note :- Old Serviceable regulator obtained from item No.1 shall be reused
S&F ceiling rose PVC / polycarbonate isolated body three terminal AC 230 volts complete all as specified and directed.
S&F in replacement metal clad plug & socket with metal plug top enclosure with a two pin and earth plug top and socket suitable for one single pole MCB 32 Amp complete all as specified and directed..
Supply & fixing submain wiring with 6 sqmm 2 runs FRLS copper conductor of single core multi stranded PVC in related unsheathed cable 1100 volts with copper conductor drawn in and including PVC conduit (appropriate size) concealed in wall with all accessories such as tees, elbows, junction box reducers etc as required along with 1 run of 6 sqmm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion complete all as specified and directed. Note :- (i) Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length. (ii) The quoted rate is deemed included the cost of PVC conduit & cutting chases.
Supply and fixing in replacement MCB distribution board SPN 240 volt, 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
Supply and fixing in replacement MCB distribution board SPN 240 volt, 6 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
Supply and fixing in replacement MCB distribution board SPN 240 volt, 4 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 16-32 Amp 240 volt 'C' curve complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specified and directed.
Supply and fixing MCB in replacement of MCB SP 6 to 32 Amp 240 volts 'C' curve 10 KA complete all as specified and directed.
S&F LED batten fitting 18/20 watt surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, system efficiency of > 120 lumens / W, LED of make : Nichia / Cree / Everlite / Eclison / OSRAM / Lumiled, with LED binding as per ANSI Bin C78 377A, photo biologica safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI > 80, temp range 0 to 45 ºC, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM 70 & LM 80 certification complete all as specified and directed. Cat part No.LTD C 01220WLED/WD of Make C&S or equivalent model as specified make of Philips / Jaquar / Wipro as approved by GE.
S&F in LED T8 batten fitting 10 W 65000 K of , MS white powder coated with PC tube retrofit complete all as specified and directed. Cat part No.LTD C 01210WLED/WD of make C&S & Cat part No.LL20-111-XXX-65-NE of Wipro or equivalent model as specified make as approved by GE.
S&F LED security light 18 watt with aluminium pressure die cast housing, high purity PC fresnel diffuser with silicon gaskets for IP-65 protection, power consumption <20 W & luminaire lume > 2500lm and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia / Cree / Osram, CRI. 70, ambient temperature range 0-450C, THD < 10% colour temperature 5700 K, surge protection CM 3.5 KV 50000 burning hour as per L70 criteria, multi stage constant current constant voltage operated driver with range 150-270 V AC and safety extra low voltage safe level <60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall complete all as specified and directed. Wipro Cat Part No.LR-06-241-XXX-57-XX or equivalent make Philips / Jaguar/General Electric
S&F square slim surface mounted LED down lighter of capacity 15 watts, 240 volts, white powder coated pressure die cast aluminium housing and bottom frame with high transmitive LGP technology, high efficiency non yellowing PMMA diffuser, complete with LEDs driver and accessories pre-wired upto terminal block lumens wattage not less than 15 watts, luminaire lumen output >1500 Lm, ingress protection IP-20, ambient temperature 0-450 C driver efficiency more than 85% power factor above 0.95, Surge protection 3 KV multi stage isolated constant current and variable working votlage 15-0270 Volts complete all as specified and directed. C&S Cat Part No.LTESSE15W LED or equivalent make Wipro/Philips / Jaguar/General Electric
S&F LED wall light 12 W unbreakable poly carbonate suitable for mounting on wall / surface complete all as specified and directed. Cat part No.SLE WL 12W-GP-200 of make Surya and Cat part No. LW33-101-025-30-XX of make Wipro or equivalent model as specified make of Bajaj / Jaquar / Philips as approved by GE.
Supply and fixing in repair of VTPN DB suitable for mounting MCCB as incomer of rating 100 Amp vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including MCCB 100 Amp, 16 KA, 4 Pole complete electrical connection with aluminum thimbles as required complete all as specified and directed.
Supply and fixing in repair of VTPN DB suitable for mounting MCCB as incomer of rating 63 Amp vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including MCCB 100 Amp, 16 KA, 4 Pole complete electrical connection with aluminum thimbles as required complete all as specified and directed.
Disconnecting and taking down old existing UNSV tube light fitting of any description and in any position, including connection complete with all accessories and down rod all complete all as specified and directed.
Fixing only in repair electric meter, single phase any size and type including 2nd class hand wood plank of suitable size for base of electric meter and nuts & bolts necessary electric connection with single core 6 sqmm PVC insulated copper conductor of suitable length as per site requirement. The quoted rate in deemed to included with 2nd class hard wood & 6 sqmm copper cable complete all as specified and directed.
Fixing only ceiling fan already taken down with point wiring including connection complete with all accessories and down rod all complete all as specified and directed.
Supply and laying in repair cable XLPE insulated screened PVC bedded, galvanzied steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core complete all as specified and directed.
Supplying and fixing in repair of GI tubing, 40 mm bore, light grade as in sleeving/protection of cable etc laid in trenches/floor or fixed on pole / wall etc. with and including suitable size of MS clamp and nut, bolt ,washer etc complete all as specified and directed
Boring holes horizontally under road without damaging the surface of road (minium 1.0 metre below the road surface with the help of GI tubing not .exc. 80 mm bore dia for passing UG cable, complete all as specified and directed. Note :- GI pipe laid will be measured and paid separately under respective item.
M&L for brick work with sub class 'B' bricks, old size brick, straight orcurved on plan to any radius in half brick wall, built in CM 1:4 complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Supply and laying sand with approved fine grade around cable for cushioning and protection of under ground cable complete all as specified and directed.
M&L for old size sub class `B` bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed .
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed Note : (i) Excavation shall be made carefully in order. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed .
Removal of surplus excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L in repair for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Guru Ji Aura
S B ENTERPRISES
Anandeshar Enterprises
M/S RAJENDRA KUMAR AGARWAL
SRI SAI CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .