Loading…
Loading…
Tender Value
₹20.5 Cr
EMD Value
₹11.8 L
Closing Date
23 Jul 2025, 3:00 pmClosed
Secunderabad Division Electrical Maintenance Department - SW - I SC- Upgradation of existing PRS Data Centre at Secunderabad for hosting Disaster Recovery site of Next Generation e-Ticketing (NGeT) System. SW- II - Replacement of Automatic Fire Alarm and Fire Protection system and Rodent Repllent system at DRDC centre- PRS/SC.
E-M-SC-23-OT-2025-26
E-M-SC-23-OT-2025-26
Open
6 Months
Hyderabad, Telangana
₹0
₹11.8 L
19 Jun 2025
19 Jun 2025
Repllent system at DRDC centre- PRS/SC.
Supplying, laying, testing & commissioning of Cable with aluminium conductor, XLPE insulated,
extruded PVC inner sheathed ,FRLS outer sheathed armoured and PVC Sheathed overall 1.1 KV
Item- 9 grade The cables shall conform to IS 7098 part-II (latest edition). Providing end Termination of
cables with supply of brass, Double compression cable glands, Solderless crimping type copper/
aluminium sockets for aluminium cables respectively.Rate shall exclude cost of cable tray."
S No. Item Description of Item Unit Qty Rate Amount
SECUNDERABAD DIVISION-ELECTRICAL/SOUTH CENTRAL RLY
"HYDRANT SYSTEM : Supply, erection, testing and commissioning of Galvanized 'C' class M.S pipes
(as per IS 1239) The pipes shall be fixed on walls or suspended from ceiling with necessary
specials. such as bends, reducers, orifice plates, if any, tees, flanges, C.I tapers etc. The rates shall
include the cost of consumables for cutting and welding, painting with a coat of red oxide and two
coats of post office red colour or with colour as specified by the consultant and Supplying and
Item- 10 wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4
mm thick polymer corrosion resistnt tape as per IS : 10221 with 15 mm overlap as per
specifications. The entire piping system in part or as a whole has to be tested to a hydraulic test
pressure of 1.5 times the rated pressure for a period of not less than 24 hours. the piping shall be
concealed after satisfactory testing of the system. The contractor shall make all arrangements for
water for testing."
S No. Item Description of Item Unit Qty Rate Amount
Supply, installation, testing and commissioning of Landing Hydrants comprising of the following in
S No. Item Description of Item Unit Qty Rate Amount
1 a Single headed hydrant valve as per IS: 5290, Numbers 12.00 9386.90 112642.80
made of SS with 63 mm dia instantaneous two
outlets and 100 mm dia flanged inelt, Blank
caps, chain and hand wheels etc., all complete
as per specifications and direction of Engineer-
2 b 2 lengths of 15 M long, 63 mm dia RRL hose Numbers 24.00 7666.46 183995.04
with instantaneuos couplings and Hoses shall be
stored in side the hose cabinet etc., all complete
as per specifications and direction of Engineer-
3 c 1 no. SS short branch pipe with nozzle (Material- Numbers 12.00 3725.26 44703.12
Copper) all complete as per specifications and
direction of Engineer-In-Charge.
4 d Hose reel drum of swinging type with 19 mm dia Numbers 8.00 13470.88 107767.04
Rubber braided hose of 36.5 M. length with
25dia Ball valve ( upstream) and Shut off nozzle
of jet and spray type, etc.,all complete as per
specifications and direction of Engineer-In-
Item- 15 Supplying, installing and commissioning Portable Fire extinguishers of following type and capacity.
S No. Item Description of Item Unit Qty Rate Amount
1 a ABC type fire extinguisher of 2.0 Kgs. Capacity, Numbers 10.00 6950.20 69502.00
with initial filling in brand new cylinder with
powder coated finish, fitted with SS union, high
pressure CO2 gas cartridge, discharge hose, wall
mounting bracket etc. complete, confirming to
2 b Fire extinguisher 4.5Kgs CO2 capacity, with Numbers 120.00 8885.40 1066248.00
initial filling in brand new cylinder with powder
coated finish, fitted with SS union, high pressure
CO2 gas cartridge, hose and ABS type branch
pipe and wall mounting bracket etc., complete,
conforming to IS:15683
SECUNDERABAD DIVISION-ELECTRICAL/SOUTH CENTRAL RLY
3 c 9 Ltr Water type Fire Extinguisher, Stored Numbers 5.00 4657.46 23287.30
Pressure Type, Pressure Gauge, Gross Weight
14.6Kg, empty Weight 5.6 Kg, Can Height
611MM, Diameter 175MM, Discharge Time less
than 120 Secs,Controllable discharge
mechanism, Range minimum 6 Meters,
applicable on Class A Fire, A Rating 13A,Can
Construction : Deep drawn & Mig welded, Valve
Construction : Forging & Machining,
InternalCoating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyester
Powder coating, Sheetmetal thickness : 2.0MM,
ISI and EN Approved, Hileum Leak Detection
tested, 1 Year Warranty
4 d ABC type of fire extinguisher of 6kgs. capacity Numbers 120.00 4728.26 567391.20
fitted with SS cap high carbon dioxide cartridge,
with suitable wall mounting brackets etc.,
complete, conforming to IS:15683
Item- 16 ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM
S No. Item Description of Item Unit Qty Rate Amount
1 a Supplying, installing, testing and commissioning Numbers 1.00 206384.36 206384.36
of Analog Addressable Fire Alarm Control panel
with battery back up for 8 hours normal
operation and 15 minutes alarm operation. The
control panel, battery charger, etc, software for
programming, The panel shall be 2 loop panel
expandable additional 2 loops capacity. The
panel shall consisting with 80 character LCD
display and RS 485 for networking.(The software
shall consisting with facility like Upload / down
load of information's to FACP, Graphics
compatible to AutoCAD, Detectors information
with change in address / sensitivity etc as
required.) Multiple loop capacity can acceptable.
( EN54 approved)
2 b Supplying, installing, testing and commissioning Numbers 160.00 3670.98 587356.80
of Analogue Addressable Smoke detector with
programmable for timed automatic sensitivity
selection with base, Junction box and other
accessories as required.
3 c Response indicator for all detectors located Numbers 50.00 185.26 9263.00
above false ceiling
4 d Supplying, installing, testing and commissioning Numbers 30.00 3797.24 113917.20
of Analogue Addressable Rate of Rise Heat
sensor detector with standard base Junction box
and other fixing accessories as required.
5 e Supplying, installing, testing and commissioning Numbers 12.00 5660.46 67925.52
of Analogue Addressable Fault isolator module
capable of monitoring shorted loop circuit and
automatically restore communications when
shorted conditions are corrected
6 f Supplying, installing, testing and commissioning Numbers 18.00 8885.40 159937.20
of Addressable Horn / Strobe wall mounted type
rated at 82 dBA @ 3m for Audible annunciation
and 75cd flashintg at 1 Hz for visual indication
along with control module etc. complete.
7 g Supplying, installing, testing and commissioning Numbers 18.00 7451.70 134130.60
of Addressable Single action Manual call point
(Break Glass Type) with back box, Back box will
be flushed on wall, having an integrally
mounted addressable module that monitors and
reports contact status.
8 h Supplying, installing, testing and commissioning Metre 3000.00 177.00 531000.00
of 2 Core X 1.5 sq. mm PVC ARMORD insulated
copper CABLE confirming to IS standards and
specifications. (Armoured Type)
SECUNDERABAD DIVISION-ELECTRICAL/SOUTH CENTRAL RLY
9 i Supplying, installing, testing and commissioning Metre 200.00 339.84 67968.00
of 4 Core X 2.5 sq. mm PVC ARMORD insulated
copper CABLE confirming to IS standards and
specifications. (Armoured Type)
10 j "CABLE TRAY Supplying and fixing of FRP Metre 150.00 730.42 109563.00
perforated cable tray with cover and necessary
angle iron suspension supports, GI anchor
fasteners etc. complete. Maximum height of
suspension shall not exceed 500 mm. Size of the
tray shall be suitable for laying the above
mentioned cables. 150 mm x 50 x 50 x 2 mm
Item- 17 RODENT REPELLENT SYSTEM (SERVER ROOM)
S No. Item Description of Item Unit Qty Rate Amount
1 a Supply, installation, testing and commissioning Numbers 2.00 27660.38 55320.76
Of Master Console panel Networking controllers
ultra VHFO console to be staked one above
other and the support to be fixed to the wall.
2 b Supply and installation Transducers monuted at Numbers 20.00 3582.48 71649.60
strategic locations and shall be communicated
copper wires in FRLS conduits of 20 mm dia, laid
on ground / wall / ceilings with propoer saddling
/ junction boxes etc.
4 d Supply and installation of Supports like stand / Job 1.00 2148.78 2148.78
brackets for fixing controllers on wall / ceiling
suspended as per site condition.
Item- 18 FM-200 GAS SUPRESSION SYSTEM
S No. Item Description of Item Unit Qty Rate Amount
1 a Supply and installation of 140 Lt PESO approved Numbers 5.00 183593.84 917969.20
Cylinder assembly
3 c Electric Cum Manual Actuator for Primary Numbers 1.00 45001.66 45001.66
4 d 1.5" Discharge Hose Flexible for Primary Numbers 1.00 17770.80 17770.80
5 e Warning Sign for Primary Cylinder Numbers 1.00 2721.08 2721.08
6 f Pressure operated control head for Secondary Numbers 3.00 10675.46 32026.38
7 g 1.5" Discharge Hose Flexible for Secondary Numbers 3.00 14904.58 44713.74
8 h Flexible Actuation Hose for Secondary Cylinder Numbers 3.00 9028.18 27084.54
9 i Tee connectors for Secondary Cylinder Numbers 3.00 2721.08 8163.24
10 j Pressure operated control head for Tertiary Numbers 1.00 10675.46 10675.46
11 k 1.5" Discharge Hose Flexible for Tertiary Numbers 1.00 14904.58 14904.58
12 l Flexible Actuation Hose for Tertiary Cylinder Numbers 1.00 9028.18 9028.18
13 m Master Cylinder Adaptor kit for Tertiary Cylinder Numbers 1.00 9887.22 9887.22
14 n Elbow connectors for Tertiary Cylinder Numbers 1.00 2721.08 2721.08
15 o Manifold check valve, 1.5" for Tertiary Cylinder Numbers 5.00 28161.88 140809.40
16 p Discharge Nozzle for Tertiary Cylinder Numbers 14.00 7021.00 98294.00
17 q Cylinder Strap for 140 Lt Cylinder for Tertiary Numbers 10.00 1862.04 18620.40
18 r Manifold Discharge Pressure Switch for Tertiary Numbers 1.00 23786.44 23786.44
19 s Cylinder Low Pressure Supervisory Switch for Numbers 5.00 24076.72 120383.60
Tertiary Cylinder
SECUNDERABAD DIVISION-ELECTRICAL/SOUTH CENTRAL RLY
"VESDA FOR SERVER ROOMS : Supply, installation, testing and commissioning of followings: System
shall be BMS compatible for remote monitoring, including Air Termination (Nozzles)"
S No. Item Description of Item Unit Qty Rate Amount
2 b Power Supply Unit for above Detection system Numbers 2.00 6734.26 13468.52
Download all tender documents and submit your bid