| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC being a 1st lowest | |
| 2 | L2₹8.1 L+₹13,468.75 (1.69%)Rejected-Finance HOUSE NO 66 GALI NO 3 ARJUN NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Higher side quoted amount | |
| 3 | L3₹8.2 L+₹28,844.25 (3.63%)Rejected-Finance | L3 | Rejected-Finance Higher side quoted amount | |
| 4 | L4₹8.5 L+₹56,399.25 (7.09%)Rejected-Finance | L4 | Rejected-Finance Higher side quoted amount | |
| 5 | L5₹8.8 L+₹81,144.25 (10.2%)Rejected-Finance 6 GURU GOBIND SINGH NAGAR DHAKOLI DHAKOLI PATIALA PUNJAB 140602 | PATIALA | PUNJAB | 140602 | L5 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹21,920
Closing Date
4 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(WEST)Pathankot
GE(WEST)Pathankot
SPL REPAIR TO BLDG No. NP-30 AT MIL STN PATHANKOT UNDER GE (WEST) PATHANKOT
2024_MES_657693_1
GE/PKT-05/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
Pathankot
As per tender and NIT doc
9 documents required · 9 mandatory
₹500
GE(WEST)Pathankot
₹21,920
31 Aug 2024
4 Jun 2024
11 Jul 2024
4 Jun 2024
4 Jul 2024
19 Jun 2024
Amount
Sch 'A' Part-I B/R work:- Taking down Chowkhats or frames exc 1.5 Sqm but not exc. 4 sq. m each (without taking off shutters from the frames) complete all as specified and directed.
S&F factory made Pressed steel frame of size 165x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete and including back filling of hollow portion of frame, fixing of hold fast with plain cement concrete type B-0, 1:2:4 using 12.5 mm graded crushed stone aggregate. Pressed steel frames shall be painted with two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as spd and directed
S&F Factory made 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates powder coated (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m powder coated (minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directd by Engr-in-Charge.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m powder coated (minimum thickness of powder coating 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F Anodised designer grill (weight of grill shall not less than 2.00 KG/Sqm) of 07mm dia and aperture of 75mmx75mm fixed with and including aluminum flat section of size 50 x 1.5 mm fixed to aluminium windows Complete all as specified and as directed.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing in aluminium shutter in square not exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing in aluminium shutter in square exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
S&F 2 levers brass Mortice lock, vertical type, size 100 mm complete all as specified and directed by Engr-in-Charge.
S&F in repair aluminium(extruded section body) door closer hydraulically regulated, designation No. 1, universal type, suitable for door shutters upto 700 mm in width and of weight 350 kg and fixed complete all as specified and directed by Engr-in-Charge.
S&F 100mm long butt hinges, medium weight, cold rolled mild steel
S&F in repair Floor door stopper 140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engr-in-Charge.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified .
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy.
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised
Demolition of existing roof treatment of any description such as worm out tarfelt, mortar of any description & any thickness, shrubs/roots ,vegetation, tree, terracing pcc/brick tiles, concrete bedding etc as directed and Cleaning of all foreign material debris etc by brushing and dusting, washing down with water etc and surface shall be leveled with a layer of 20 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions and applying roof treatment with 03mm thick APP modified membrane with non-woven polyster reinforcement(center core) with thermal insulation with white mineral gravel finish on upper side of weight not less than 3.5 kg/sqm , laid by torch application method with overlap 100 mm on length side and 100 mm on the width side as per manufacturer's instructions over one coat of approved cold applied bituminous oil based primer (IS-3384) @0.30 litre/sqm complete all as specified and directed
M&L for Rendering 10 mm thick on other than fair face of brick work or concrete/stone surfaces in CM 1:6 finished even and smooth without using extra cement including taking down of old plaster complete all as specified.
M&L for Rendering 15 mm thick on fair face of brick work or concrete/stone surfaces in CM 1:4 finished even and smooth without using extra cement including taking down of old plaster complete all as specified.
M&L for preparation of newly plastered surface and finish the surfaces of wall with one coat of wall care putty and applying two coat of oil bound distemper on walls complete all as specified and as directed by Engr-in-Charge.
M&L for preparing new plastered surfaces and applying two coat of cement base paint over a coat of Chalk whiting on walls complete all as specified and directed by Engr-in-charge.
M&L for preparation of old plastered or unplastered of wall washing, rubbing down and stoping of distempered and painted surfaces and applying two coat of distemper oil emulsion complete all as specified and directed.
M&L for preparation of old plastered or unplastered of wall washing, rubbing down and stoping of painted surfaces and applying two coat of cement base paint complete all as specified and directed.
M&L for preparing old steel surfaces of any description over 10cm width/girth and applying one coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Disconnecting existing tanks of capacity exc 250 ltr & n exc 500 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.
S&F in repair 15mm dia bore GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor including testing complete all as specified and directed by Engr-in-Charge.
S&F in repair 20mm dia bore GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor including testing complete all as specified and directed by Engr-in-Charge.
Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing serviceable like to store and rubbish off the premises, complete all as specified and directed by Engr-in-Charge
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over backing layer of 10mm thick of cement mortar 1:4 all as specified and directed.
Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) bends any radius of 110mm bore complete all as specified and directed by Engr-in-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
S&F for suspended false ceiling system using chicago metallic (E grid) exposed supended system, grid section size 600mm X 600mm comprising of GI powder coated Main Runner of dimensions 39 mm X 24mm X 0.8mm (thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of runner 1.35 kg for 3600 mm length) Cross Tee of dimensions 29mm X24mmX 0.8mm thick and wall angle 22.2mmX22.2mmX0.65 mm thick ( thickness comprising of GI/0.35+ PPPCGS/0.3mm & weight of angle 0.70 kg for 3050mm length)with and including 4mm thick HPSC(High pressure steam cured) pre-primed, self embossed. textured designer board, water resistant termite resistant, fire resistant for insulation to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed purlins of the roof with butterfly clips(Wt-0.007 Kg/clip)hold down clips (Wt-0.0035 Kg/clip) complete all as specified and directed.
Sch 'A' Part-II E/M work:- Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC rigid concealed conduit heavy duty suitable size with all accessories having thickness not less than 1.8 mm including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked for switches and sockets , including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed.
All as per Srl item No 39 here-in-before but for 5 pin 5 amps socket outlet on independent board complete all as specified and directed.
All as per Srl item No 39 here-in-before but for 5 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistrand copper conductor FRLS cable with in and including PVC concealed conduit heavy duty suitable size having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed.
S&F in repair switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S&F in repair switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S&F in repair ceiling rose 65 x 50mm three terminals complete all as specified and directed.
S&F in repair ceiling fan regulator electronic socket type 5 stage speed variation.
S&F in replacement sleek LED Batten light fitting 4 feet long 1x20 W including LED tube 4 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed.
Taking down ceiling fan, by disconnecting electric connection, dismantling blades and removing fan from ceiling complete all as specified and as directed
Re-Hanging only ceiling fan (M.D. supply) and connecting up including provision of pvc insulated seathed copper cable 3 core 0.75sqmm from ceiling rose or connector to fan including minor repair such as replacement of locking pin, reel insulator, bolts, nut etc. including Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
S&F in repair distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface complete all as specified and directed
S&F in repair MCB SP 6-40 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repair MCB SPN 40 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in replacement sub Main Wiring with two Run of single core PVC insulated unsheathed multistrand FRLS flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. Note:-Two run of submain wire (phase and neutral) and one run of earth wire including PVC conduit and accessories will be measured as one run.
S&F in replacement bldg secuirty light fitting energy saving high efficiency LED street light fitting 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length not less than 0.9 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 05 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted).
S&F LED luminarie 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete 6000K/3000K with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S&F in repair energy saving 120 watt highbay LED light with PDC aluminium housing with PC lens cover & mounting eye bolt with IP65 protection, ceiling (surface/suspended) mounting with system efficacy upto 110Lm/W complete all as specified and directed.
S&F in replacement vertical distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way with 415 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, triple pole and neutral 415 volts, 3 phase 50Hz, mechnical strength as IK-09, with one MCCB 3 pole 415V 100 Amp , 16KA(adjustable thermal and adjustable magnetic release) and 12 x MCB's SP 40 Amps C series as outgoing of the same make as of distribution board flush to wall / fixed on surface and making good the disturbed surface as per existing complete all as specified and directed
S&F air circulator fan metal body (industrial type) 230 Volt single phase oscillating 450mm sweep suitable for wall mounting having not less than 1400 RPM/min including fixing on wall and connection complete all as specified and directed
Supply, installation and testing all weather split AC units indoor and outdoor of 1.5 Ton capacity BEE 3 star rating with EER not less than 3.2 complete with cordless remote control unit, inbuilt anti-microbial air filtration for better indoor air quality including copper piping of suitable size with insulation, PVC drain pipe, mounting plate for indoor unit and brackets of powder coated GI steel for outdoor units and mounting with suitable size of anchor bolts and nuts including making hole of suitable size on wall for passing wire and copper pipes complete all as specified and as directed.
Supply, laying and testing in repair LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq. mm 4 core complete all as specified
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for laying of pipes/cable etc and not exceeding 10 sqm on plan for manholes etc and getting out in any type of soil, complete all as specified. and directed by Engr-in-Charge.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I complete all as specified and as directed by Engr-in-Charge. Note:-Punned thickness will be measured and paid
M&L for brick covering with width equal to length of brick as mechnical protection to cable with well burnt sub class 'B' bricks laid as directed.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Removal to excavated material (Soil) to a distance not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for GI tubing light grade 80mm bore for cable protection laid in tranches or in road crossing or fixed to wall/pole including all fittings complete all as specified and directed by Engr-in-Charge.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 11,551.00 and any other reduction if any from quoted amount.
ADVAIT CONSTRUCTION CO
M/S Raghuvanshi Builders
OMKAR SHARMA AND CO
JP AND CO.
M/S SATYA SAI CONSTRUCTION
GANDOTRA CONSTRUCTION CO
DABGOTRA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .