| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.2 L+₹67,549 (1.85%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹38.1 L+₹1.6 L (4.38%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹38.3 L+₹1.8 L (5.06%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹38.6 L+₹2.1 L (5.72%)Rejected-Finance AKASHGANGA SUKANTA MARG MONIRAMPORE BARRACKPORE WEST BENGAL 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
22 Jul 2023, 6:00 pmClosed
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/MAINTENANCE OF VARIOUS TYPE OF SUMMER AND WINTER APPLIANCES, FAN, GEYSER, WATER COOLER, REFRIGERATOR AND INTERNAL ELECTRICAL FITTING, SUB MAIN WIRING, DBS, MCCBS, EARTHING AND MISC B/R WORKS AT CH (EC) UNDER GE ALIPORE KOLKATA
2023_MES_607339_1
GE/ALP (8263B) KOLKATA OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ALIPORE KOLKATA
Class D and category b (i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹70,000
Yes
GE ALIPORE KOLKATA
19 Sept 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
22 Jul 2023
15 Jul 2023
30 Jun 2023 - 7 Jul 2023
8 Jul 2023
Amount
Taking down shutter exc 1.0 sqm but not exc 2 sqm each and refixing in same opening complete all as specified and directed.
Resuring, easing /adjusting without taking down shutter from the frame ,size of shutter exc 1.0 sqm but not exc 2 sqm each complete all as specified and directed..
Taking down aluminium door(any size) and refixing in same position ,change of pivot, beading, gasket, setting of door and change of damaged style /rail any length in aluminium section thickness not less 1.50 mm match with existing anodised /powder coated complete all as specified and directed .
S&F for floor door stopper of overall length of cover plate in 150mm aluminium alloy body abd tonuge with hard drawn steel spring complte all as specified and directed.
M&L for preparing old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and directd.
M&L for preparing of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and directd.
S & F in repairs aluminium body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851-1000 mm in width & weight between 61 to 80 Kg complete all as specified and directd.
S&F in repair 5 mm thick beveled edge best quality looking mirror of size 600x450 mm fixed with screws complete all as specified and directed.
S&F in repair stainless steel soap dish fixed in wall with screws complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid, joint free, coloured ceramic tiles 6-7mm thick (square/rectunglar),area of each tile exc 0.11 Sqm but not exc 0.18 Sqm. as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles,over and including 15mm thick screed bed in CM (1:4) complete all as specified and directed .
M&L for coloured, glazed ceramic tiles size 450x300x 6-7mm thick, in dado/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10 mm thick rendering in CM (1:3) complete all as specified and directed .
M&L for light shade vitrified ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry and pointed in white/colour cement to match over and including bedding screed bed 15 mm thick in CM 1:4
M&L for granite(of any type) 18-20 mm thick for slab machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15 mm thick screed bed in cement mortar 1:4 including grinding & polishing fixed in slab/steps complete all as specified and directed.
Demolition of PCC in ground floor and pavings not exc 15 cm thick below or above ground level complete all as specified and directed.
M&L for 50 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
S&F in repair sinks without drainage board made of stain less steel 1mm thick kitchen with plugs, washer and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe bowl size 410mmx330mmx160mm complete all as specified and directed.
S & F in repair stainless steel toilet paper holder fixed with CP screws in wall ,complete all as specified and directed.
S & F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as spd and directed.
S & F in repair 110/125 mm floor trap fixed in floor with grating including jointing with solvent cement concrete 1:2:4 complete all as specified and directed
S&F fixed in repairs 32 mm dia waste pipe for wash hand basin and urinal down pipe complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan ( padestal pattern) including PVC seat cover , (excluding fixing bolts, flushing cistern and flush pipe) , including connection to drain ( or outgoing pipe) and to flushing pipe etc. complete complete all as specified.
S&F in repair PVC valveless, symphonic action low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white, flat back, size 550mm x 400mm, excluding chain and plug and porcelain stopper but including cutting for and pinning in ends and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.
S&F in repair 15mm bore CP angular valve,with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F in repairs 15 mm dia CP bib taps, with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore pillar taps, chromium plated, with capstan heads, chromium plated, fancy type screwed down for pipe, high pressure , with or without 'lettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified and directed.
S&F in repair 600 mm long PVC connection 15 mm size with PTMT nut complete all as specified and directed .
S&F in repair 20 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor (concealed ), ceiling or laying in floors complete all as directed .
S&F in repair 25 mm bore (Outer dia) CPVC pipes of SDR 13.5 and plain CPVC SDR 11 fitting fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and directed.
M & L in repairs hospital curtain track system using hindalco/Jindal powder coated aluminium sections with fabric quality 180 GSM complete all as specified and directed. (Note : All accessories required for fixing /installation of curtain track system shall be provided by the supplier)
S&F in repair 50 mm bore (outer dia) UPVC pipes of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and directed.
S&F in repairs towel rail 600 mm long of brass chromium plate 20mm dia fixed with and including chromium plated brass screws & wooden/plastic cleats complte all as specified and directed.
Cleaning and dusting of GI pipes line 15 to 25 mm dia by GI wire and pressure pump and washing down whole GI line complete all as specified and directed.
S&F in repair PVC health faucet with all necessary fittings complete all as specified and directed.
S&F in repair 15 mm bore CP Pillar cock cliical faucet complete all as specified and directed.. (Make : Cera cat No F9030101 or equivalent as approved the GE)
S&F in repair 15 mm bore CP surgical elbow operated tap with 200mm lever handle screwed down for iron pipe and fixed complete all as specified and as directed.
S&F in repair 15 mm bore CP shower rose fancy type 150mm long neck complete all as specified and directed.
M&L for L-shaped rubberised corner guard for sharp vertical edges of length 1000mm, width 100 x 100mm reflective type of thickness 10mm complete all as specified and directed.
Taking down ceiling fan of any type, any make and any sweep for repairing,opening the body and blade, checking for repalcement of unserviceable spares,cleaning, overhauling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same complete all as specified and directed. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Rewinding of ceiling fan, 1200mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper/manllex paper with cotton binding, heat varnished and including flexbile cable for electric connection complete all as specified and directed.
All as per item No 41 here-in-before but for 1400mm sweep.
Supply only ball bearing of size 6201/6202/6203
Supply only metal bush bearing suitble for ceiling fan 1200/1400 mm sweep of any type and size complete all as specefied and directed.
Supply only capacitor for ceiling fan 2.25 MFD complete all as specified and directed.
Supply only capacitor for ceiling fan 2 MFD complete all as specified and directed.
Supply only fan blade (3 Nos blade is one set) 1200 mm sweep suitable for Make: USHA/Havells /Bajaj or equivelent make complete all as specified and directed.
Supply only fan blade (3 Nos blade is one set) 1400 mm sweep suitable for Make: USHA/Havells /Bajaj or equivelent make complete all as specified and directed.
Supply only stepped type electronic fan regulator existing phenolic laminated sheet of AC 120/280 volt complete all as specified and directed.
Supply and fix as in repair of MS clamps made out of 50 x 6mm flat iron suitable for hanging of ceiling fan on pipe including necessary cutting, threading, drilling, fixing arrangement split pin, nuts, bolts washer etc complete all as specified and directed.
M&L in replacement of fan hooks, hold fasts for suitable for hanging of ceiling fan complete make good complete all as specified and directed.
M&L in replacement of GI tubing 15 mm bore 'light grade',galvanised, (down rod) with all fitting; suitable for hanging of ceiling fan as required complete all as specified and directed.
Material and labour for painting of ceiling fan complete, in situ of size 1200/1400mm sweep with down rod upto 2.00 mtr long with two coats of synthetic enamel white paint including preparation of old painted surfaces including writing of MES No with letters n. exc 15mm height complete all as specified and directed.
Taking down exhaust fan/wall mounted fan of any type, any make, by opening of body carefully checking for repalcement of unserviceable spares, including replacement of spares by new one, re-assembling of all components in original position, cleaning, oiling greasing, testing and fixed in original position Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Rewinding of exhaust fan, 300mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished and all as directed.
All as per item No 55 here-in-before but for 350 mm sweep.
All as per item No 55 here-in-before but for 450 mm sweep padestal fan.
All as per item No 55 here-in-before but for wall mounting fan 400 mm sweep complete all as specified and directed.
Supply only capacitor for exhaust fan 4.00 MFD complete all as specified and directed.
All as per item No 59 here-in-before but 3.15 MFD complete all as specified and directed.
Material and labour for preparation of exhaust fan/wall mounting fan and applying one coat of grey synthetic enamel paint by spraying using spray gun with filling cavities including writing of MES No, taking down and refixing complete all as specified and directed.
Rewinding of padestal fan, of size 450 sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished complete all as specified and directed.
Rewinding of wall mounting fan, of size 400mm sweep with super enamelled copper wire and insulation of starter with polyster paper/manllex paper with cotontak binding, heat varnished complete all as specified and directed.
Supply & fix in repair loovers of exhaust fan, 300mm sweep with fixing arrengment complete all as specified and directed.
Supply & fix in repair loovers of exhaust fan, 350mm sweep with fixing arrengment complete all as specified and directed.
Supply & fix in repair loovers of exhaust fan, 400mm sweep with fixing arrengment complete all as specified and directed.
Supply & fix in repair loovers of exhaust fan, 450mm sweep with fixing arrengment complete all as specified and directed.
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity. Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
Supply only heating elements of 2 KW 230 V suitable for water heater of any type including connection with suitable cable all as directed
All as per item No 69 here-in-before but of 1.5 KW complete all as specified and directed .
Supply & fix in repair thermostat switch of geyser 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater.
Supply & fix in repair indicating lamp, 230 V, flush type, rectangular, red and green indicator suitable for water heaters.
Supply & fix in repair PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser.
Supply only 450mm long brass CP connection with 2 nuts without nipple suitable for geysers. Make : Jaquar Cat No 805B or equivalent approved by GE.
Material and labour for preparation to old painted surface of storage water heater and painting of geyser 25 ltr capacity with two coats of synthetic enamel paint (white) by using spray gun completye all as specified and directed.
All as per item No 75 here-in-before but for 35/50 ltrs capacity.
Supply and fix as in repair for split cover made out of 22 guage sheet duly painted with synthetic enamel paint suitable for water heater of 25 ltr capacity.
All as per item No 77 here-in-before but for 35/50 ltrs capacity.
Supply and fixing as in replacement patented nano polymer coated steel inner tank of 25Ltr capacity geyser suitable for model of make: Cromption/Usha/Bajaj complete all testing and make good in disturbed surface at existing location and all as specified and as directed.
All as per item No 79 here-in-before but for 50 ltrs capacity.
Supply and fix as in replacement nono polymer coated steel inner tank of 25 Ltr capacity geyser suitable for model of make Usha/Bajaj/Cramption complete all as specified and directed.
Supply and fix as in repair for non return valve, 15mm bore, screwed down high pressure, cast copper alloy, chromium plated.
Supply and fix as in repair for pressure release valve 15mm bore 'T' type at inlet/ outlet or dead weight type heavy duty.
Supply and fix as in repair for apparatus plate , including suitable for water storage heater type 25 ltrs capacity.
Supply and fix as in repair for fusible plug , calibrated 95 deg to 100 deg C suitable for water heater.
Supply and fix as in repair for glass wool , between the inner and outer vessel of water heater any type and capacity.
Supply and fix as in repair for PVC insulated flexible copper conductor cable (FRLS) 4 Sqmm 3 core , 1100 Volts grade conforming to IS 694.
Supply and fix as in repair 15mm dia GI nipple, 2" long including GI socket.
Supply and fix as in repair rubber gasket for appratus plate any type/capacity all as specified and directed.
Material and labour for replacement of 80-100 mfd starting capacitor for water cooler of capacity 80/ 150 ltrs, make : Sarda/ Power or equivalent approved by GE.
Material and labour for replacement of running capacitor 10 mfd for water cooler of capacity 80/ 150 ltrs, make : Sarada/Power or equivalent approved by GE..
Material and labour for replacement of 15mm bore chromium plated push cock suitable for water cooler of any capacity as per existing shape and make.
Material and labour for replacement of thermostat switch for water cooler, make : Indfoss or equivalent approved by GE.
Material and labour for replacement of ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of size 15 mm
Disconnecting defective sealed compressor unit of water cooler upto 150 ltrs capacity from the water cooler and fixing repaired/ reconditioned sealed unit compressor in original position all as specified and directed.
Material and labor for replacement of door gasket for 150 ltrs capacity water cooler
Material and labor for replacement of door gasket for 80 ltrs capacity water cooler
Material and labour for replacement of starting relay suitable for water cooler 80/ 150 ltrs capacity
Material and labour for replacement of overload protector suitable for water cooler of capacity 150 ltrs
Material and labour for replacement of overload protector suitable for water cooler of capacity 80 ltrs
Material and labour for replacement of starting relay box type for refrigerators of capacity upto 315 ltrs
Material and labour for replacement of capillary copper tube of size 0.36 mm for refrigerators of capacity upto 315 ltrs
Material and labour for replacement of freezer door for refrigerators of capacity upto 315 ltrs
Material and labour for replacement of thermostat switch (Make : Indfoss/Kelvinator) for refrigerators of capacity upto 315 ltrs
Material and labour for replacement of chill tray for refrigerators of capacity upto 315 ltrs
Disconnecting defective condensor coil of refrigerators upto 315 ltrs capacity and replacing the same with new condensor coil and fixing in original position as per existing
Material and labour for replacement of inner lights for refrigerators of capacity upto 315 ltrs
Disconnecting defective sealed compressor unit of refrigerators upto 315 ltrs capacity and fixing repaired/ reconditioned sealed unit compressor in original position all as specified and directed.
Material and labour for replacement of door switch for refrigerators of capacity upto 315 ltrs
Material and labour for replacement of 5 Amps, 230 Volts Plug Top Make : Anchor or equivalent approved by GE..
Supply and fixing digital thermometer LCD (Hygrometer ) for indoor humidity and tempratuer sensor all as specified and directed.
Supply and refill for suitable gas for refrigrator up to 315 Ltr all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down carefully sub main wiring of size upto 16 sqmm including making good disturbed surfaces of walls, ceilings etc all as specified and directed .
Material and labour for surface type point wiring for one light/fan point controlled by one way switch,with 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade ,controlled by one way switch drawn through and including appropriate size of PVC casing caping with all accessoriese for surface wiring including 1.5 sqmm PVC insulated un shealthed copper cable (FR-LSH) multistrand conductor 1100 Volts grade for continuity earth wire connected to each point and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick PVC laminated/bakalite sheet cover all as specified and directed.
All as per item No 115 here-in-before but for 3 Pin socket outlet 5 Amps same board with other switches with cable 1.5 Sq mm size
All as per item No 115 here-in-before but for 3 pin 5 Amps independent board
All as per item No 115 here-in-before but for 3 pin 5 Amps independent in the same vertical plane/below the switch board of light/socket points with cable,1.5 Sq mm size.
All as per item No 115 here-in-before but for 5 pin 15 Amps switch socket combination on independent board with 2.5 Sqmm cable.
All as per item No 115 here-in-before but for power supply unit consisting of starter or 5 pin 15Amps switch socket combination on independent board with 4.0 Sqmm cable.
M & L for socket outlet 2 in 1,3 pin, 5 Amps, 240 V on same board all as specified.
M & L for switch socket combination 3 pin 15 Amps, 240 V flush type, all as specified and directed.
M & L for switch socket combination 5 pin 16 Amps, flush type, 240 Volts, universal all as specified and directed.
Materials & labour for power supply unit consisting of starter with 20 amps over load protection, MCB-20 amps, 2 pin & earth plug socket including MS/PVC box & top cover for AC (Make: Crabtree or equivlent make approved by GE.
S & F for switch piano type 5 Amp single pole one way all as specified and directed.
S & F for ceiling rose surface backelite 65 x 50mm three terminal all as specified and directed.
Supply and fixing for stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc including taking down old unserviceable regulator all as specified and directed.
Supply and fixing in repair for socket outlet 2 in 1,3 pin, 5 Amps, 240 V on same board all as specified and directed.
Supply and fixing in repair for switch socket combination 3 pin 15 Amps, 240 V Flush type, all as specified and directed.
Supply and fixing in repair for power supply unit consisting of starter with 20 amps over load protection, MCB-20 amps, 2 pin & earth plug socket including MS/PVC box & top cover for AC after taking down old one (Make: Crabtree or equivlent make.
Supply and fixing in repair for switch piano type 5 Amp single pole one wayall as specified and as directed.
Supply and fixing in repair for buzzer call bell AC 230 Volt single pole. all as specified and directed.
Supply and Fixing in repair of for bell push 5 Amp all as specified and directed.
Supply and fixing in repair for ceiling rose surface backelite 65 x 50mm three terminal all as specified and directed.
Supply and fixing in repair for Switch piano type 5 Amp two way all as specified and directed.
Supply and fixing in repair of MCB, single pole, 240 Volts, of capacity (6-32 Amps) as ordered breaking capacity 10 KA. Make-Legrand Cat No-4085-87 to 4085-95 or equivalent grading ISI marked.
Supply and fixing in repair MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as specified and directed. Make-Legrand Cat No-4086-18 to 4086-20 or equivalent grading ISI marked.
Supply and fixing in repair MCB TPN, 63 Amps, 240 Volts , breaking capacity 10KA complete all as specified and directed. Make-Legrand Cat No-4087-02 or equivalent grading ISI marked.
Supply and fixing in repair MCCB TPN, 160 Amps, 240 Volts , breaking capacity 25KA complete all as specified and directed .Make-Legrand Cat No-4200 57 or equivalent grading ISI marked.
Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Supply and fixing as in repair MCB DB SPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed .
Supply and fixing as in repair MCB DB SPN (double door) 2 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Supply and fixing as in repair MCB DB TPN (double door) 4 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed.
Material and labour for sub main wiring for main DBs to sub DBs with standard copper conductor 1100 volts grade of size 4 sqmm two runs of multistrand unsheathed PVC insulated cable (Red colour cable used for live connection & Black colour cable used for neutral connection) and 4 sqmm copper multistrand conductor 1100 volts grade multistrand un-sheathed PVC insulated (Green colour cable used) cable for earth continuity wire connected from main earth through PVC conduit / casing caping of size 25mm for including of all accessories complete all as specified and directed. Note : Two runs of 4 sqmm and one run of 4 sqmm cable with PVC conduit shall constitute one unit.
Supply and fixing as in repair sub main wiring(surface type) for main DBs to sub DBs with PVC insulated & unshaethed four two runs of 6 Sqmm single core multistrand copper conductor cable, 1100 Volts grade alongwith one run of 6 sqmm PVC insulated & unshaethed copper conductor cable, 1100 Volts grade, connected to common earth dolly as earth continuity conductor, with PVC conduit / casing caping of size 25mm for including of all accessories complete all as specified and directed. Note : (a) two runs of 6 sqmm and one run of 6 sqmm cable with PVC conduit/caping casing shall be constitute one unit.
M & L for sub main wiring as in repair wiring ( surface type) for main DBs to sub DBs with PVC insulated two runs of 10 sqmm single core multistranded copper conductor cable , 1100 volts grade, along with one run of 10 sqmm PVC insulated & unsheathed copper conductor cable, 1100 Volts grade, connected to common earth dolly as earth continuty conductor , through PVC conduit / casing caping of as required for including of all accessories complete all as specified and directed. Note : Two runs of 10 sqmm and one run of 10 sqmm cable with conduit pipe / casing caping shall be considered as one unit.
Supply and fixing as in repair sub main wiring(surface type) for main DBs to Sub DBs with PVC insulated & unshaethed four runs of 16 Sqmm single core multistrand copper conductor cable, 1100 Volts grade alongwith two runs of 16 sqmm PVC insulated & unshaethed copper conductor cable, 1100 Volts grade, connected to common earth dolly as earth continuity conductor, with PVC casing capping/PVC conduit of suitable size including of all accessories complete all as specified and directed. Note : (a) Four runs of 16 sqmm and two runs of 16 sqmm cable with PVC conduit/caping casing shall be constitute one unit.
Materials and labour as in repair earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50 mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 500 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Supply and fixing for earth continuity conductor of 25x4 mm galvanised iron strip with saddle and fixing screw for conductor above ground, complete all as specified and directed.
Supply & fixing for electronic LED light fitting driver up to 36 watt
S&F in repair main terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing main switch board of any size (housing of switches, sockets outlets, regulators etc) complete including making good with existing colour of disturbed surfase of wall complete all as specified and directed.
S&F in repair GI terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing size housing of at least one switch sockets outlets15 Amps etc complete including making good with existing colour of disturbed surface of wall complete all as specified and directed.
S&F in repair GI terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing size housing of at least one switch sockets outlets 5 Amps etc complete including making good with existing colour of disturbed surfase of wall complete all as specified and directed.
S & F in repair bakelite laminated sheat top cover 3mm thick of existing size main switch board (mounting of switches,sockets outlets,regulators etc) complete including refixing seviceable switches, switch sockets and regulators etc complete all as specified and directed.
S & F in repair bakelite laminated sheet top cover 3mm thick of existing size for mounting of ,switch sockets outlets 15 amp, etc complete including refixing seviceable switch sockets etc complete all as specified and directed.
S & F in repair bakelite laminated sheet top cover 3mm thick of existing size for mounting of switch sockets outlets 5 Amp etc complete including refixing seviceable switch sockets etc complete all as specified and directed.
Supply & fixing for LED Spot light deep recessed antigare LED Spot down light for gerneral accent light 10 make Havells cat No - UNECOBRITER 10WLED827S24 or equvalant in Philips/Havells/Magik Century
Supply and fix in repair 2'x2' energy efficient recess mounting 30 watt LED lumanaries fixing for POP ceiling housing including LED lamps other accessories and necessary electric connection after and including taking down old unserviceable fittings complete all as specified and directed.Make : CROMPTON,Cat No-LCTLRNE-30-FO-CDL or equvalant in Philips/Havells/Magik Century
R.R.ENTERPRISE
ARATI TRADING CO
KWALITY CONSTRUCTION
SREE GURU CONSTRUCTION CO
JOY-EN-JOY
MS JYOTI INDUSTRIES
NUPUR CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .