GE (Utilities) Udhampur PO-Garhi , Pin-182121
Repair/Maintenance of Air conditioner, Deep Freezer, Winter appliances alongwith connected accessories under GE (Utilities) Udhampur
2025_MES_694572_2
GE/U-73/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
As per NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampurl
₹50,000
27 Mar 2025
4 Mar 2025
22 Mar 2025
4 Mar 2025
18 Mar 2025
4 Mar 2025
Amount
M&L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacturer with high pressure pump of 1.0/1.5/2.0 ton capacity complete all as specified and directed by Engr-in-Charge.
M&L for detection/rectification of leakage of gas by vacume the system, charging with Nitrogen gas and vacume the system after detaction of lekage and gas charging in the system with appropriate quantity of gas as per OEM Recomentation including testing for smooth functioning of Split type/ Window type AC of capacity 1.0/1.5/2.0 Ton complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-22 in Split/Window air conditioner,of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-32 in Split/Window air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant gas R-410A in Split air conditioner of capacity 1.5/ 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and topping up of refrigerant Hydrocarbon gas ( R-600a) in refrigerantor (Each Can 200g) complete all as specified and directed by Engr-in-Charge.
Supply only Butane Gas (Each can 225 g) suitable for torch complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new indoor unit of split AC of capacity 1.5 ton with compitable for existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new indoor unit of split AC of capacity 2.0 ton with compitable for existing out door unit from authorized dealers of company complete all as specified and directed by Engr-in-Charge.
Repair/replacement PCB for any make and model window/Split type AC 1.5 ton / 2Ton capacity complete all as directed by Engr-in- charge .
Repair/replacement inverter technology PCB complete with indoor /outdoor unit and sensor for any make and model split type AC 1.5ton/2Ton cap complete all as directed by Engr-in- charge .
Supply and fix in replacement coil senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr –in – charge.
Supply and fix in replacement heating senser of existing shape and size suitable for 1.5/2 Ton Split Type AC complete all as specified and directed by Engr –in – charge.
Supply & fixing in replacement of thimble brass suitable for all type of AC,Water cooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in- charge.
S&F in replacement blower motor of Split type AC 1.5/2.0 Ton of existing make & model complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement blower(plastic body) of 1.5/2.0 Ton Split/Window type AC complete all as specified and directed by Engr-in- charge.
Supply and fix in replacement cooling coil of existing shape and size suitable for 1.5/2 Ton Split/Window type AC all as specified andcomplete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement condenser coil of existing shape and size suitable for 1.5/2Ton Split/Window type AC complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement & testing of Fan Motor of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motor of capacity 1/8 HP double shaft for 1.5 /2.0 Ton window type AC including base, frame, side clamps complete in all respect. Make: Air master/ Crompton.
Description same as Srl item No 19 Fan motor 1/7 HP of split type AC any make & model complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG Make complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton
Supply and fix in replacement front show grill for LG/Voltas /Sidwal/Godrej window type AC 1.5 Ton complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of unsv Reverse cycle valve for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr –in –charge.
Supply & fixing flexible drain pipe for Window type/Split Type AC of any capacity complete all as specified and directed by Engr-in- charge.
Supply and fix in replacement swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge. Make:- LG/Voltas/Hitachi/Godrej.
Supply and fix in replacement Fan Blade of 1.5/2 ton window type AC of any capacity complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Fan Blade of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement discharge valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement suction valve of 1.5/2 ton split type AC of any capacity complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement bush of 1.5/2 ton split type AC .of any capacity makle LG/ Voltas complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement capillary of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement dead nut of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement NRV of 1.5/2 ton split type /window type AC .of any capacity complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement of unserviceable remote control unit Suitable for 1.5 / 2.0 Ton split/window type AC complete all as specified and directed by Engr-in- charge.
Supply & fix in replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge.
Taking out old existing unserviceable foam insulation and supply and fix new foam insulation of 1.5 / 2 ton split type /window type AC of any capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement new rotary type AC compressor of existing split type/window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge.
All as per serial item No.36.00 here-in-before but of size 2.0 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement new Reciprocating type AC compressor of existing split type /window type AC with New compressor from authorized dealers of OEM capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge.
All as per serial item No.38.00 here-in-before but of size 2.0 ton capacity complete all as specified and directed by Engr-in-Charge.
Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract.
Supply and fix in replacement Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts complete all as specified and directed by Engr-in- charge.
Supply and fixing in replacement MCB SPN 32 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB SP 20 to 32 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
S&F in replacement Sub main wiring with two single core PVC insulated FRLS unsheathed copper conductor multistranded cable 1100 volts grade 6 sqmm size in PVC Conduit heavy duty ISI marked with 6sqmm PVC insulated FRLS copper coductor multistranded cable as earth lead to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
S&F in replacement Wiring for connection between outer and inner unit of split AC with four single core PVC insulated FRLS unsheathed copper conductor multistranded cable 1100 volts grade 2.5sqmm size in PVC conduit heavy duty ISI marked with 2.5 sqmm PVC insulated FRLS copper conductor multistranded cable as earth lead/single to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement overload/PTC relay for water cooler ,Deep freezer and referigerator supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigerator satisfactory performance commissioning acomplete all as specified and directed by Engr-in-Charge.
Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA,5KVA,2KVA,1KVA,0.5KVA thoroughly checking,cleaning all parts by brushing and assembling after repalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair / replacement of components as below:-
M&L rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA complete all as specified and directed by Engr-in-Charge.
Description all as per ser item No.48 here - in-before but of capacity 5KVA complete all as specified and directed by Engr-in-Charge.
Description all as per ser item No.48 here - in-before but of capacity upto 2KVA complete all as specified and directed by Engr-in-Charge.
M&L in replacement of relay for 7.5KVA & 5KVA,30amp 24volts DC complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Step down transformer 24 volts 2Amp for 7.5 KVA & 5KVA complete all as specified and directed by Engr-in-Charge.
M&L in replacement of circuit plate with connection wire complete all as specified and directed by Engr-in-Charge.
M&L in replacement of relay for 0.5KVA, 1KVA & 2KVA,16amp 24volts DC complete all as specified and directed by Engr-in-Charge.
M&L for Refrigerator/deep freezer any make and capacity finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confroming no leakage . The reassembling the same deep freezer by provinding proper insulation m+B59aterial at the disturbed area all as per entire satisfaction complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Fan motor with fan suitable for any make & model refrigerator 286ltr / 310 Ltr complete all directed by Engr-in-Charge
Description all as per srl item No 56 above but suitable for 165 to 195 litre Refrigerator complete all as specified and directed by Engr-in- Charge .
Description all as per srl item No 56 above but suitable for 320 litre Deep freezer complete all as specified and directed by Engr-in- Charge .
Taking out old unserviceable Condensing coil for 165/170 to 310 Litre Referigerator and supply and fix new condenser coil of existing make shape and size complete all as specified and directed by Engr-in-Charge.
Supply and fix new thermostate for Refrigerator/Deep freezer of any capacity any make complete all as specified and directed by Engr –in- charge.
S&F in replecement new sealed compressor suitable for Deep Freezer of single phase, 230 Volt, 50 Hz of Deep Freezer of any Size in and including refrigerant gas filling up to required level complete all as specified and directed by Engr-in-Charge.
S&F in replecement new sealed compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refigerator of any Size in and including refrigerant gas filling up to required level complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement Capacitor of capacity 50+6 mfd for window /split type AC complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Capacitor of capacity 36+6 mfd for window /split type AC complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement Capacitor of capacity 80+100 mfd for split/window ac complete all as specified and directed by Engr –in- charge.
Supply and fix in replacement diffrerent make and size shelf of refrigerator omplete all as specified and directed by Engr –in- charge.
M&L for periodical repair / overhauling of Steam Boiler of 400 Kg capacity (Make : Thermax RXD) - 03 Nos by engaging sufficient man power and suitable T&P to ensure safety of boiler plant as well as working persons including disconnecting of water / steam / electric connections, dismantling of boiler plant by unscrewing/cutting of screws, nuts & bolts etc, taking out complete coil assembly and other major parts from the boiler etc, replacing all defective spares parts, cleaning / De Scaling/ servicing of coil assembly incl electrical control panel board, all machine works i.e. welding, cutting, drilling/ lathe etc as and when required and reassembling all dismantled part/items after carrying out necessary repair as required, other material, cleaning, servicing, oiling, greasing etc, making all steam / water connection and electrical connection, leak testing at desired pressure, with and including testing, commissioning of complete boiler plant in original location for smooth and trouble free operation, to entire satisfaction of Engr-in-charge, complete all as specified and directed by Engr-in-Charge.
Note : The entire work incl spare parts / items, shall be got executed through OEM i.e. M/s Thermax Ltd only. The contractor shall submit the record of overhauling / periodical/preventive maint services carried out by M/s Thermax Ltd. The boiler plants will be handed over to contractor in as and when condition and cost of all kind of repair incl minor items i.e. wire, lugs, nut, bolts, screws etc, other than mentioned in here-in-after is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract. Cost of transportation is also deemed to be incl in quoted rate.
Supply only limit switch suitable for Steam Boiler of 400 Kg capacity complete all as directed complete all as specified and directed by Engr-in-Charge.
Supply only water level switch suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only Sequence controller suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only Burner Rod suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only SS diffuser plate 132 mm suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only steam temprature controller TC 513 complete all as specified and directed by Engr-in-Charge.
Supply only electronic sequence timer suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only thermocouple (TC) K type SS310 for Primary chamber suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only safety relief value suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only blow down value suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only photocell suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
S & F PRV (Pressur reducing valve ) including fixing arrangement , welding , brazing and taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Supply and Fix Boiler Optimizer (Operation Performance Management for steem Plant) suitable for 400 Kg as per existing shape and size including taking down old unserviceable one acomplete all as specified and directed by Engr-in-Charge.
Supply and Fix Boiler Economiser (Energy improving device) suitable for 400 Kg as per existing shape and size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Supply only Resin T-40 NA all as directed complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, of RTD PT-100 temperature sensor output, complete all as directed complete all as specified and directed by Engr-in-Charge.
S&F, in replacement, of RTD temperature controller 0-1200ºC, K type input, complete all as directed complete all as specified and directed by Engr-in-Charge.
Supply only oil filter suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only ignition electrode suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only photo ignition sensor suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only Fuel pump AJ6AC suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only Valve seat assembly for triplex pump suitable for Steam Boiler of 400 Kg capacity complete all as specified and directed by Engr-in-Charge.
Supply only Maxclean 05 descaling chemical for boiler plant complete all as specified and directed by Engr-in-Charge.
Supply only Hardness kit for testing of water complete all as specified and directed by Engr-in-Charge.
Supply only TDS meter for testing of water complete all as specified and directed by Engr-in-Charge.
Supply only PH meter for testing of water complete all as specified and directed by Engr-in-Charge.
S&F in replacement of electronic Microprocessor Based controller Display suitable to 60Kg Water extractor controlls & commands of 60 Kg water extractor with programming all listed parameters as per recommendation including testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water solinoid valve 40 mm for 60 Kg water extractor complete all as specified and directed by Engr-in-Charge.
S&F in replacement of hose pipe 40mm 1.2 m long for 60 Kg water extractor complete all as specified and directed by Engr-in-Charge.
S&F in replacement ofdoor lock assembly for 60 Kg water extractor complete all as specified and directed by Engr-in-Charge.
S&F in replacement of electronic Microprocessor Based controller Display suitable to 100 Kg Water extracor controlls & commands of 100 Kg water extractor with programming all listed parameters as per recommendation including testing complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of power contactor of 25 Amp AC3 rating, 03 pole, 415 V, ML 1.5 2NO+2NC contacts with and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of power contactor of 25 Amp AC3 rating, 03 pole, 415 V,ML3 1 2NO+2NC Aux contacts with and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of over load relay MN2 range 20-33 Amps, with built in single phase preventer, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as specified and directed by Engr-in-Charge.
Supply Only metalic hose pipe pump to optmizer complete all as specified and directed by Engr-in-Charge.
Supply Only steam flexible pipe (PVC) for flat work ironer (single/double Rollers) complete all as specified and directed by Engr-in-Charge.
Supply Only steam pressure gauge suitable for 400 kg boiler complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-62 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-65 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-70 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-72 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-80 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-85 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-86 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement V belt B-92 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement belt B-107 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement belt B-118 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement belt B-640 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement belt B-655 Make: Fenner/Powerfix/Dunlop complete all as specified and directed by Engr-in-Charge.
Supply Only in replacement of V-belt of size B-128 complete set (05 Nos) suitable for Washer Extractor of 120 Kg capacity complete all as directed.
S&F RCBO double pole, 240 Volts , 50 Hz 10 Ka, 40 Amps, 30mA complete all as specified and directed by Engr-in-Charge.
S&F and fixing 415V 10KA 'C' mainature circuit braker of TPN 40 to 100 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of unsv Resistance for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton complete all as specified and directed .
Supply and fix in Split ac outer unit stand complete with nut and bolts for outer unit 1.5 Ton /2.0 Ton complete all as specified and directed by Engr-in-Charge.
Dimantling,lifting ,shifting and insattation of VRF outoor unit 16/20 HP with complete LT Panel board with all electrical connection and testing and commissioning complete all as specified and directed by Engr-in-Charge.
Diconnecting all electrical and copper tubing connection,taking down carefully,shifting and installation of VRF indoor unit 1.5/2.0 TR Make-Carrier complete all as specified and directed by Engr-in-Charge.
Dimantling and taking down carefully all electrical connection, copper tubing with 'Y' joint ,PVC connection and MS Channel and re-installed at Comminity Centre near Command library complete new electrical connection between inner unit and outer unit of VRF and copper tubing with using of old and new tubing with insulation with Y joint, as per site requirment and drain pipe for inner unit connection complete complete all as specified and directed by Engr-in-Charge.
Supply & fixing inverter of rating 800 VA with input AC voltage + 150V to +280 Volts and output AC voltage 230V + 10% operating Sine waves of alternating current while DC input voltage 12V of battery complete all as specified and directed by Engr-in-Charge. Make:- EXIDE/SU-KAM/LUMINOUS
M/S M P Construction Co (BID ID -3260544)
VARDHMAN INTERNATIONAL (BID ID -3265770)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .