Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | ₹15.0 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹17.9 LRejected-Finance SKALZANGLING AIR PORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | ₹17.9 L | L2 | Rejected-Finance Being other then L1 bidder |
| Sl No | Description | Qty | Unit | PADMA ENTERPRISES L2 | Mehar Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | M&L for Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified and as directed by Engr-in-Charge. | 37.25 | Sqm | 250 ₹9,312.50 | 33 ₹1,229.25 |
| 2.00 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits,manholes, pier holes, etc, n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil, complete all as specified and as directed by Engr-in-Charge | 63.77 | Cum | 400 ₹25,508 | 260 ₹16,580.20 |
| 3.00 | M&L for Removal excavated material n,exc 50m and depositing where directed at a Cum level n.exc 1.5 m above the startig point, complete all as specified and as directed by Engr-in-Charge | 30.7 | Cum | 100 ₹3,070 | 66 ₹2,026.20 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge | 33.07 | Cum | 100 ₹3,307 | 110 ₹3,637.70 |
| 5.00 | M&L for PCC 1:4:8 Type D2 (using 40mm graded crushed stone aggregate) as in foundaion, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge | 5.1 | Cum | 6,000 ₹30,600 | 5,600 ₹28,560 |
| 6.00 | M&L for RCC M25 design mix Foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc., basement slabs. under-reamed piles and mass concrete, complete all as specified and as directed by Engr-in-Charge. | 13.51 | Cum | 10,000 ₹1.4 L | 8,660 ₹1.2 L |
| 7.00 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter, complete all as specified and as directed by Engr-in-Charge. | 62.76 | Sqm | 1,500 ₹94,140 | 330 ₹20,710.80 |
| 8.00 | M&L for RCC M-25 design mix as in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engr-in-Charge. | 3.68 | Cum | 10,000 ₹36,800 | 8,800 ₹32,384 |
| 9.00 | M&L for Formwork to sides and Formwork to sides of pillars, posts, struts, piers, columns and stanchions beam haunchings, girders, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc. complete ail as specified and as directed by Engr-in-Charge | 42 | Sqm | 1,500 ₹63,000 | 360 ₹15,120 |
| 10.00 | M&L for RCC M-25 design mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engr-in-Charge | 6.2 | Cum | 10,000 ₹62,000 | 8,860 ₹54,932 |
Updated dates
Tender Value
₹18.4 L
EMD Value
₹36,900
Closing Date
9 Mar 2026, 6:00 pmClosed
GE 865 EWS
GE 865 EWS PIN-913865 c/o 56 APO
PROVN OF TOILET AND BATH FACILITY WITH ALLIED INFRASTRUCTURE FOR TROOPS AT MAIN GATE GUARD ROOM IN BRAVO ENGR REGT UNDER GE 865 EWS LEH
2026_MES_751188_1
865/EWS(NIT-111)/2025-26
Open Tender
Civil Works
180 days
GE 865 EWS
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹36,900
Yes
30 Mar 2026
4 Feb 2026
11 Mar 2026
4 Feb 2026
9 Mar 2026
18 Feb 2026
M&L for Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified and as directed by Engr-in-Charge.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits,manholes, pier holes, etc, n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil, complete all as specified and as directed by Engr-in-Charge
M&L for Removal excavated material n,exc 50m and depositing where directed at a Cum level n.exc 1.5 m above the startig point, complete all as specified and as directed by Engr-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge
M&L for PCC 1:4:8 Type D2 (using 40mm graded crushed stone aggregate) as in foundaion, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge
M&L for RCC M25 design mix Foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc., basement slabs. under-reamed piles and mass concrete, complete all as specified and as directed by Engr-in-Charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter, complete all as specified and as directed by Engr-in-Charge.
M&L for RCC M-25 design mix as in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engr-in-Charge.
M&L for Formwork to sides and Formwork to sides of pillars, posts, struts, piers, columns and stanchions beam haunchings, girders, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc. complete ail as specified and as directed by Engr-in-Charge
M&L for RCC M-25 design mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engr-in-Charge
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) complete all as specified and directed by Engr-in-Charge.
S&F for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Reinforcement 10 mm and over, complete all as specified and as directed by Engr-in-Charge
S&F for mild steel TMT bars up to and including 6 to 8 mm dia in stirrups, spacers and binders as in columns and beams etc., complete all as specified and as directed by Engr-in-Charge
M&L Precast cement concrete 1:3:6 Type C1 (using 20mm graded crushed stone aggregate) block masonry with solid blocks exc 10cm in width and setting in CM 1:6 complete all as specified and directed by Engr-in-Charge
M&L for 5mm thick rendering on ceiling surfaces in Cement morter 1.3 finish even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick rendering on fair or other than fair faces of brick work or concrete surfaces in cement mortar 1:6 finish even and smooth without using extra cement, complete all as specifeid and as directed by Engr-in-charge.
M&L for rendering 15 mm thick in CM 1:4 on fair/unfair faces of brick work or concrete surfaces finishing even and smooth without using extra cement and mixed with liquid WPC 200 ml per bag of cement on walls (WPC shall be measured and Paid separately) complete all as specified and as directed by Engr-in-Charge.
Supply only water proofing compound liquid, complete all as specified and as directed by Engr-in-Charge.
M&L for 2nd class Hard wood plain, solid, straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed by Engr-in-Charge
S&F 2nd class hard wood 30mm thick panelled shutters plain, framed, panelled shutters (any number of panels) with panels of timper feather edged teak wood planks supplied and fitted to chowkals, complete all as specified and as directed by Engr-in-Charge
S&F 30mm thick glazed 2nd class Hard wood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), supplied and fitted to chowkat, complete all as specified and asdirected by Engr-in-Charge
S&F 4,80 mm thick sheet glass, ordinary quality in square or rectangular not exc 0.50 Sqm in each pane fixed as per instructions of anufactures, complete all as specified and as directed by Engr-in-Charge.
S&F framed work such as Grills, grating etc with ends of bars shouldered and or revited or forged into spiles framed guard bars barred iron doors ladders framed balusters walk ways railings etc confirming to Fe 290, Gde E-165, complete all as specified and as directed by Engr -in- Charge.
M&L for Band straps, hooks, pintle hinges, large hasp and staples, chains hand made sliding bolts clamp, hold fasts, any type of angles, wall ties etc, complete all as specified and as directed by Engr -in- Charge.
M&L for two coats of synthetic enemal paint over a coat of red oxide zinc chrome primer on steel surfaces of any description including preparation of surfaces, complete all as specified and as directed by Engr-in-Charge
M&L for three coat of white wash on ceiling incluiding preparation of surface, complete all as specified and as directed by Engr-in-Charge
M&L for two coat of oil bound distemper over a coat of primer Incluiding preparation of new surfaces of walls, complete all as specified and as directed by Engr-in-Charge.
M&L for two coat of cement base paint over a coat of primer complete Incluidng preparation of new surfaces of wall complete all as specified and directed by Enar-in-Charge
M&L for two coats of synthetic enemal paint over a coat of pink primer on wooden surface of any description including preparation of surfaces, complete all as specifeid and as directed by Engr-in- Charge
S&F 200mm long aluminium anodised barrel tower boit of extruded section, complete all as specified and as directed by Engr-in-Charge
S&F 100mm long aluminium anodised barrel tower bolt of extruded section, complete all as specified and as directed by Engr-in-Charge
S&F Aluminium alloy, anodised, sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and as directed by Engr-in-Charge.
S&F aluminum door handle cast type 150 mm, complete all as specified and as directed by Engr-in-Charge.
S&F aluminum door handle cast type 100 mm, complete all es specified and as directed by Engr-in-Charge.
S&F 100mm long mild steel medium weight but hinges cold rolled, complete all as specified and as directed by Engr-in-Charge
S&F 75mm long mild steel medium weight but hinges cold rolled, complete all as specified and as directed by Engr-in-Charge
M & L for hardcore of brocken stone gauge n,exc 63mm deposited spreed and leveled in layers n,exc 15cm thick including watering and rammed to true surfaces, complete all as specified and as directed by Engr -in-Charge.
M&L for 100 mm thick Cement concrete type C-2, 1:3:6 (40mm graded crushed stone aggregate) as in sub base, complete all as specified and as directed by Engr-in-Charge
M&L for 25 mm thick PCC Cement concrete type B-1, 1:2:4 (20mm graded crushed aggregate complete all as specified and directed by Engr-in-Charge
M&L for 7 to 8 mm thick non skid coloured ceramic tiles (area of each the exc 0.11 and n. exc 0.18 sqm) etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge.
M & L for Glazed ceramic coloured tiles in vertical surface 450x350x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering i cement mortor 1:4 for dado/skirting, complete all as specified and as directed by Engr-in-Charge.
Material & Labour for 75mm thick PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in plinth protection and finished concrete surface even and smooth without using extra cement including making proper joints with bitumen mastic with sand as per specification at an interval of 3m, complete all as specified and as directed by Engr-in-Charge.
S&F 25mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings like elbow, socket, FTA, MTA etc fixed to walls, ceilings or in floors etc., complete all as specified and asdirected by Engr-in- charge.
S&F PVC (SWR) pipe 110 mm bore single socketed in any length with rubber RM ring joints laid in trenches or in floors, complete all as specified and as directed by Engr-in- charge.
S&F PVC (SWR) 110mm bore bends any radius, complete all as specified and as directed by Engr-in- charge
S&F PVC (SWR) 'S' trap 110mm bore for EWC/IWC, complete all as specified and as directed by Engr-in- charge
S&F viterous China squatting pan or Orissa pallen 580 x 440 mm white with integral foot rest (excluding cistern) with front or back inlet ant pattern including bedding with p.c.c type B-1 1:2:4, using 20 mm graded crushed stone aggregate, complete all as specified and as directed by Engr-in-Charge.
S&F, 10 ltrs capacity incl PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets & flush pipe, complete all as specified and as directed by Engr-in-Charge.
S&F 20mm bore bib taps fancey type chromium plated with capstan head chromium plated screwed down screwed for iron pipe or brass ferrule (Minimum wt 350 Gms), complete all as specified and as directed by Engr-in-Charge.
S&F 20mm bore stop cock fancy type chromium plated cast copper alloy screw down under high pressure with crutch or butter fly handle screwed both ends for iron pipe or brass ferrule, complete all as specified and as directed by Engr-in-Charge,
S&F Soap dish fixed with and incl CP brass screws, complete all as and as directed by Engr-in-Charge
S&F PVC connections 15mm size with CP nuts of length 600mm, complete all as specified and as directed by Engr-in-Charge
S&f 75mm bore PVC (SWR) pipe bends any radius, complete all as specified and as directed by Engr-in-Charge.
M&L 75 mm bore PVC (SWR)) multi floor trap with grating including jointing with solvent cement, complete all as specified and as directed by Engr-in-Charge,
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and as directed by Engr-in-Charge.
S&F Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and as directed by Engr-in-Charge
S&F concealed 20mm bore stop cock fancy type chromium plated cast copper alloy screw down under high pressure with crutch or butter fly handle screwed both ends for iron pipe or brass ferrule, complete all as soecified and as directed by Engr-in-Charge
S&F 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as soecified and as directed by Engr-in-Charge.
S&F Towel rail with accessories, complete all as specified and as directed by Engr-in-Charge.
S & F Vitreous china wash basin white flat back size 550 x 400 mm including including CI brackets of irosn 65 x 65 x 6mm embeded in PCC block with PCC 1:2:4 type B-1 & CP grating with holes fixed, complete all as specified and as directed by Engr-in-Charge.
S&F PVC waste pipe 32mm bore with cup and washers, complete all as specified and as directed by Engr-in-Charge
S&F 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and as directed by Engr-in-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and as directedby Engr-in-Charge.
M&L for PCC type B1 (1:2:4) using 20 mm graded crushed stone aggregate as in coping, Complete all as specified and as directed by Engr-in-Charge.
M&L for Cement concerete bed to drain pipes incl packing under haunching against the sides of pipes after they are laid tested in 1:3: 6 type C-2 using 40 mm graded crushed stone aggregate for bore of pipe upto 200mm, complete all as specified and as directed by Engr-in-Charge
S&F 200mm dia bore (inner dia) double wall corrugated HDPE pipe (SN-8) in any length including all fitting and jointing with eastomeric rubber link and cuppler/other jointing material laid in trenches are in floors, complete all as specified and as directed by Engr-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stopped ends etc.complete all as specified and directed by Engr-in-Charge.
M&L for Type B-1 1:2:4 (20mm grade aggregate ) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs including necessary formwork and in shelves, complete all as specified and as directed by Engr-in-Charge
M&L for soakage well of 1.80 mtr dia having min 3.0 mtr depth of 380 mm thick random rubble uncoursed stone masonary wall in CM 1:6 with 150 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) below stone masonary at bottom and RCC slab using nominal mix M-25 with reinforcement 10 mm dia bars @ 150 mm c/c bothways cranked at 1/4 th of the span including arrangenment for manhole oening and manhole cover, inlet for 100/150 mm dia pipe and rest all as specified as per Drg No CESZ/TD-1078/2011 sheet 1/1 Note :- The rate includes excavation in hard/dense soil and construction of soakage well as per drawing connection of inlet pipe, 100 mm dia PVC vent pipe with cowl, returning, filling and removing of surplus soil to a distance exc 50 mtr but not exc 100 mtr from site for any issues regarding drawing decision of Engr-in-Charge shall be final during execution.
M & L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable, complete all as specified and as directed by Engr-in-Charge Note : For payment purpose punned thickness shall be measureed and paid for.
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other, complete all as specified and as directed by Engr-in-Charge
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 50 Sqmm 3.5 Core, complete all as specified and as directed by Engr-in-Charge.
Supply and fixed gun metal globe or gate valve of 40 mm, complete all as specified and as directed by Engr-in-Charge.
M&L for excavation and tapping from existing line of dia 80 mm by means of weding and including all necessary materials required for the work, complete all as specified and as directed by Engr-in-Charge.
S&F 40 mm bore tube medium grade galvanized with all fitting and fixed to wall, ceiling or laid in floor and trench, complete all as specified and as directed by Engr-in-Charge.
Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead complete all as specified and as directed by Engr-ih-Charge for the followings:-
One light/fan point controlled by one way switch complete all as specifieed and as directed by Engineer-in-Charge.
One socket outlet 5 Amps, 230 volts point on independent board complete all as specifieed and as directed by Engineer-in-Charge.
One socket outlet 6 Amps, 230 volts on same board complete all as specifieed and/or directed by Engineer-in-Charge.
All as item No 77 above, but using cables 4 Sq mm size complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix switch piano flush button single pole 6 Amps 230 volts one way complete all as specifieed and as directed by Engineer-in-Charge.
Supply and Socket out let two in one 5 pin 6 Amps flush type.230 volts complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix Ceiling rose, surface Bakelite three terminals complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 04 way complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix MCB SPN 40 to 63 Amp 240 Volts AC ISI marked complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix MCB SP 6-32 Amps. 240 Volts 50 HZ complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix LED light fitting 1X20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifieed and as directed by Engineer-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specifieed and as directed by Engineer-in-Charge.
Supply, install, testing complete water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 Litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc. complete all as specifieed and as directed by Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
TENDERNIT111.pdf
Tender Documents • 1.48 MB
BOQ_841323.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid