Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC OFFICE NO 2 GROUND FLOOR CO OP HSG SOCIETY SBS ROAD COLABA MARKET MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹3.7 Cr Quoted ₹3.8 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹4.6 Cr+₹79.2 L (20.7%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | ₹4.6 Cr+₹79.2 L (20.7%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹4.7 Cr+₹85.7 L (22.4%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | ₹4.7 Cr+₹85.7 L (22.4%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹4.9 Cr+₹1.1 Cr (27.8%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹4.9 Cr+₹1.1 Cr (27.8%) | L4 | Rejected-Finance Other than being lowest |
| 5 | L5₹5.0 Cr+₹1.2 Cr (30.2%)Rejected-Finance | ₹5.0 Cr+₹1.2 Cr (30.2%) | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹5.5 Cr
EMD Value
₹6.0 L
Closing Date
10 May 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIRS TO R-19 BUILDING AT NAVY NAGAR , COLABA, MUMBAI
2025_MES_703623_1
8256/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
545 days
GE (NW) Navy Nagar
Class A
Category a (i)
8 documents required · 8 mandatory
₹3,000
GE (NW) Navy Nagar
₹6.0 L
Yes
7 Jul 2025
7 Apr 2025
12 May 2025
7 Apr 2025
10 May 2025
5 May 2025
7 Apr 2025 - 26 Apr 2025
Amount
SCHEDULE 'A' PART I Taking down carefully cement plaster (Chipping off ) Loose plaster (external) by low impact Hammer without damaging the structure of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for Chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure & cleaning and disposal of debris out side the MoD Land etc complete all as specified and directed by Engr-in-Charge. Note :i) Hard concrete should not be removed by force. ii)Work shall be carried out at G+14 bldg including roof top,parapet and shaft walls including scaffolding & safety measures
Dismantling/ Removing Carefullly Concrete of any description and position by low impact Hammer, Breakar without damaging the structure & cleaning and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Clean existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc. complete and providing, applying two coats of alkaline rust converting primer conforming to ASTMB- 117, on the existing rebars and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer , including cleaning the reinforcement,wirebrushing to remove loose rust spalls, with time interval of 1 hour between the coats complete all as per manufacturers instructions. Note :Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including scaffolding & safety measures
M&L for providing and fixing additional steel bar or stirrups of diameter in various structural elements like columns, beams and foundations including drilling, bending and fixing the bars with epoxy putty etc complete all as specified and directed by Engr-in-Charge . Note : Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including scaffolding & safety measures
M & L for providing and application of hitech concrete penetrating, water based, organic, Bi-polar, calcium nitrite free, migratory corrosion inhibitor on concrete surface having Ph 9.5 which migrates to a virtual extent of 100 mm inside concrete through pores, to inhibit the corrosion process on embedded steel at both anodic and cathodic ends by depassivating the Electro-chemical reaction in that region thereby protecting rebar on all sides complete all as per manufacturers instructions. Note :Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including scaffolding & safety measures
M & L for providing and application full and unbroken coating of anticorrosive protective zinc rich epoxy coating on expose reinforcement in two coats with time interval of minimum 1 hours between each coat including mixing of both componants by weight as per manufacturers specifications, brush application, curing to form a anticorrosive protective coating with high mechanical strength to cementitious repair works complete all as per manufacturers instructions. Note :Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including scaffolding & safety measures
M & L for mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per square metre on prepared concrete surfaces of parent material complete all as per manufacturers instructions. Note :i) Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including scaffolding & safety measures ii) SBR latex shall be measured and paid separately.
M & L for cutting out cracks to V-section in any structural agent , cleaning out all dust, wetting and applying polymer bonding agent followed by flexible polymer based putty and shall be filled properly in cut 'V' groove and finish using spatula complete all as specified and directed by Engr-in-Charge. Note :i) Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including scaffolding & safety measures
M & L for mixing and applying SBR latex modified cement mortar 30 mm average thickness in in proportion of 1:3 (1 cement and 3 quartz aggregate) with polymer admixed in proportion as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed Note : ii) SBR latex will be measured and paid separately ii) Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including steel scaffolding & safety measures
M & L for rebuilding the section of damaged RCC elements to required size avg thicknes 50 mm by providing and casting with microconcrete of grade M-40 and above including providing and fixing of water tight shuttering of minimun 12 mm thick with supporting framework,all lead lift, mixing, placing, deshuttering, levelling the surface by grinding off cementitious slurry or construction joint to the satisfaction of Engr -in- charge. Note - Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including steel scaffolding & safety measures
M & L for providing and Casting in position RCC design mix M30 Grade using clean sharp aggregates 10 mm down along with addition of Non shrink admixure including transporting, mixing, laying, curing, etc complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Drilling Holes of 10mm dia, upto 40mm deep in structural members at the interval of 300 to 500mm in staggered manner or along the crack as directed by the Engr-in-charge in RCC structural element including Cleaning of the holes by air blower and Inserting 10mm dia. Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system for min. 8 hrs before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface after completion of the work complete all as specified and directed by Engineer-in- Charge. Note : i) Drilling of hole shall be done by authorized applicator and the work shall be executed in the presence of company rep. ii) Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including steel scaffolding & safety measures
M & L for providing and fixing special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of formwork for beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies etc. complete all as specified and as directed. Note - Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including steel scaffolding & safety measures
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Supply only approved SBR Latex polymer. Note: Rate shall be in terms of solid contents of polymer.
M&L for demolition of existing water proofing treatment including PCC padding/ bricks bats coba /cement mortar of any thickness & any description in any position including cleaning of RCC roof slab with wire brushing, washing out with water and finally remove all dirt using air jet and removal of debries out side MD land complete all as specified and directed by Engr-in-Charge. Note :- Work shall be carried out above 14th and 15th floor.
Material & Labour for PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as a leveling course / padding on RCC roof top surfaces laid to slope and finished fair and even, roof kerbs or mud stops,rounded or chamfered on edges complete all as specified. Note :- Work shall be carried out above 14th and 15th floor.
M&L for 10mm thick rendering using factory manufactured pre mix / ready mix mortar mixed with and including WPC 100gm per 50Kg bag of mortar on fair faces of green/moist concrete surfaces complete all as specified and directed by Engr-in-Charge. Note :- Work shall be carried out above 14th and 15th floor.
Material and Labour for protecting the roof including parapet wall with water proofing coating complete as specified below :- Supply and applying high performance polyurea polyurethane elastomeric waterproofing coating cold applied by spray /brush , smart care ultron liquid membrance with an elongation of 600% and tensile strength not less then 6.0 N/Sqmm as per ASTM D 2370, crack briding ability of 3mm as per ASTM C 1305, shore a hardness of min 75 as per ASTM D 2240. The system included final base prepraration epoxy primer application and applying smart care ultron or approved equivalent in two coats at 1.2 kg/sqm each coat complete all as per manufacturer specification and instructions including water proofing treatment to rain water spouts of entire roof terrace by opening of all the existing failed loose pipes and its joints ( in old structure) , replaceing the same by an appropriate dia pipe ( not less then 110mm) followed by application of two coats polymer polyurethane elestomeric water proofing coating to ensure leakage free joints ( work included filling of mortar and marking good the same) and top surface finished with UV resistant top coat as per manufacturers instruction Note :- 1) The colour of each coat shall be as directed by GE. 2. The work shall be carried out by authorised applicator only 3. Water proofing to rain water spouts to be done as per manufacturer instruction 4. Work shall be carried out above 14th and 15th floor
M & L for providing and injecting chemical emulsion for post construction anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion at 2.25 litre per linear meter including drilling and plugging holes with white cement and match the surface to existing apron complete all as specified and directed by Engineer-in-Charge.
M&L for post construction anti termite treatment of soil under existing floors using chemical emulsion @ 1 litre per hole at 300mm center to center and 300mm deep including drilling and plugging 12mm dia holes with cement mortar 1:2 or white cement to match the existing floors complete all as specified and directed by Engr-in-Charge.
M&L for post construction anti termite treatment of voids in masonry using chemical emulsion @ one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors all as specified and as directed by Engineer-in-charge.
M&L for post construction treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same with sealing compound complete all as specified and directed by Engr-in-Charge.
M & L for providing and applying dubbing coat with forced application (guniting) method avg 20mm-30mm thick plaster with readymix prepacked proportioned dry mix mortar, blended with PP fibers, mixed with and including liquid water proofing compound on other than fair faces of brick wall or concrete surface complete including provn of chicken wire mesh at the junction of RCC and brick wall of 300 mm width on both side of junctions all as specified and directed by Engr-in-charge. Note :Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including steel scaffolding & safety measures
M & L for providing and applying 10mm thick plaster using prepackd factory manufactured ready mix mortar on external surface as in finishing coat mixed with and including WPC @ 200ml per bag of mortar on Brick or concrete surfaces with recrene finish complete all as specified and directed by Engr-in-Charge. Note :Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including steel scaffolding & safety measures
M & L for providing & applying anti algal water-based Elastomeric exterior wall finish on new plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area ) of Elastomeric exterior wall finish BY roller complete all as per manufacturers instructions. (Make- Dr Fixit Rain coat 601, Asian paints, Berger ) Note :Note :Work shall be carried out at G+14 bldg including roof top, parapet and shaft walls including steel scaffolding & safety measures
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for providing and applying 10mm thick plaster using prepacked dry mix ready mix mortar on fair faces of concrete in ceiling and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for preparation of old decorated surfaces of ceiling and applying two coats of white wash complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for providing and applying 15 mm thick plaster using readymix prepacked dry mix mortar on fair faces of brick work or concrete surfaces and finished fair and even complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for preparing new plastered surfaces of wall, applying one coat of wall care putty not less than 1mm thickness and making the surface even and smooth using emery paper and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for complete removal of existing treatment including washing, rubbing down and stopping of distempered and painted wall surfaces, filling holes and cracks with filling putty on wall and applying one coat of wall care putty not less than 1mm thickness and making the surface even and smooth using emery paper and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for Writing letter or figures n exc 30 cm high (Block,Roman, Italic or Indian) using two coats of thick acrylic emulsion paint complete all as specified and directed by Engr-in-Charge.
Dismantling of MS grill and MS steel door of any description and position complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for MS framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings etc conforming to Fe.290.Gde-E-165 complete all as specified
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repairs MS plain black sheet 1mm thick for covering to door shutters, covering to door chowkats (frames), chulla hood, water tanks, water troughts, ducts, cut to size edges bedded if directed, holes punched, including round headed scres, clouts nails or rivets and fixed to wood or steel members, etc with plain 40mm lap joints or welded/riveted seams including, turning up mitred angles, stopped ends, outlet etc fixed complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for Welding in repairs n.exc 2.5 cm in length thickness of metal to be welded Exc. 6mm but n.exc 9 mm complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for Preparation of new or previously untreated surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying one coat of red oxide primer and two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for preparation of old painted surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L in repairs anodised aluminium sheeting 22 gauge thick fixed in crumple section including necessary scaffolding and safety measures complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Demolition of lime concrete of any description and in any position not otherwise specifically provided for and removal of debris out of MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for plain cement concrete 1:5:10 type E2 (using 40mm graded stone coarse aggregate) for filling in sunken floor complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for treatment of sunken floor slab comprises of the following specifications : i) Cleaning of the sunken /lowered portion of the RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chiesel out any mortar sticking to the surface and brooming / washing completely. ii) Providing 50 mm bore and 350 mm long medium grade GI pipe spouts with GI wire mesh on inside mouth after removing existing pipe and sealed the surrounding of GI pipe and junctions with epoxy mortar. iii) All pipes laid in sunken portion shall be covered with 50 mm thick PCC 1:3:6 type C1 all around after painting with anticorrossive black japan paint. iv) Providing 40 mm thick avg PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in padding achieve proper slope v) Rendering on bottom and sides with 10 mm thick factory manufactured pre mix / ready mix mortar mixed with and including WPC of UltraTech WP+ 200 @ 200ml per bag of mortar and finished even and fair. vi) Fill the sunken portion with water and check dampness and seepage, where dampness and seepage noticed nozzles shall be fixed and grouting carried out. vii) All junctions points of side walls where CI/GI pipes are passing through shall be sealed with epoxy putty.
viii) After drying wash the slab and sides of sunken portion with water and make it clean and dry (ix) Applying two coats of polymer modified cementious water proofing coating as per manufactures instructions to bottom and vertical sides up to finished flooor level +100 mm height. The thickness of two layer shall be 1 mm. When the second layer is still sticky, coarse sand shall be speinkled on vertical and bottom surface of the sunken portion. (x) Rendering on bottom and sides with 20 mm thick factory manufactured pre mix / ready mix mortar mixed with and including WPC of UltraTech WP+ 200 @ 200ml per bag of mortar and finished even and fair including rounding of corners and junctions sloping towards spout. Note: i) Test the water proofed area (ponding test) by filling water for atleast 72 hours and tested for leakage seepage to the entire satisfaction of GE. If leakage/Seepage occured after filling water, the above treatment shall be re-done completely without any extra cost. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained duly signed by all. ii) The treatment shall be carried out through authorised applicators of chemicals and . iii) Work shall be carried out up to Height of 14th floor
Supply & Fixing in repair cast iron floor trap with CP grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1, diameter of outlet 75mm bore complete all as specified and directed by Engr-in-Charge .
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing debris outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for non skid digital coloured ceramic tiles 300 x 300 x 7 to 8mm thick laid in floor over and including 20mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for digital coloured glazed ceramic tiles, size 300x450 x 7-8 mm thick laid on vertical surfaces such as skirting/dado laid over and including 10mm thick backing coat in CM (1:4), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal of debris out of MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Enginner-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for Brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and directed by Enginner-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for double charge glazed vitrified coloured tiles 600 x 600 x 9-10 mm thick , laid in floor over and including 20mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for double charge glazed vitrified coloured tiles 600 x 600 x 9-10 mm thick laid on vertical surfaces such as skirting/dado laid over and including 10mm thick backing coat in CM (1:4), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for machine cut Kota stone (greenish colour, mirror polished) slab flooring 18-20 mm thick as in floors, laid over and including 20mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including rubbing, cutting and polishing as specified in SSR Part I complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M &L for machine cut Kota stone (greenish colour, mirror polished) slab flooring 18-20 mm thick as in vertical surfaces such as skirting/dado laid over and including 15mm thick backing coat in CM (1:4), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile including rubbing, cutting and polishing as specified in SSR Part I complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Dismantling stone slabs, pavers and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar including removal of rubbish out side MD land. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L machine cut Kota stone (greenish colour, pre polished) slab in one piece as in staircase treads 18-20 mm thick laid over and including 20mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including bull nosing, rubbing, cutting and polishing as specified in SSR Part I complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M &L for 18-20 mm thick machine cut Kota stone (greenish colour, pre polished) slab in one piece as in vertical surfaces such as risers laid over and including 15mm thick backing coat in CM (1:4), set and jointed in neat cement paste and pointed in white or coloured cement to match the shade of tile including rubbing, cutting and polishing as specified in SSR Part I complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for grinding and polishing with machine the existing Kota stone flooring and skirting after cleaning with mild acid/detergent solution and filling/pointing the joints of tiles with white cement mixed with pigment to match the colour of tiles as specified in SSR Part I complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for machine cut machine polished cudappah stone 20-25 mm thick in one piece laid over base, and jonted with grey cement slurry mixed with pigment to match the shade of the stone including rubbing, polishing and necessary hole for gas pipe complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L machine cut machine polished granite (of any type) slab 18 to 20mm thick as in kitchen plateform in one piece laid over and including 10mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile and making necessary hole for gas pipe complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F for 18-20 mm thick machine cut, machine polished kota stone single piece length as in jambs/cills of windows laid over and including 15mm thick screed bed/ backing coat in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed by Engr-in-Charge. (Note : Kota stone single piece of Cill will be fixed in two steps)
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for two Nos grooves 2mm x 2mm over stair case treads complete all as specified and directed by Engr-in-Charge.
M&L for cutting chases in brick walls pining in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of shelves etc. and making good disturbed surfaces, cutting not exc 10 cm width or girth complete all as specified and directed by Engr-in-Charge.
S&F in repair sink with drain board, made of stainless steel 1mm thick kitchen or laboratry with plugs, washers and wastes coupling fitting, including beading in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repair vitreous china wash hand basin with half pedestal white, size 470mm x 360 mm (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed by Engr-in-Charge. Make : Kerovit cat part No CROCK-KS215 or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 32 mm dia Waste fittings, brass chromium plated suitable for glazed ware sinks, wash basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repair pillar tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge. Make : Kerovit cat part No KB411001 or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 32mm dia LDPE PVC waste pipe of pressure rating 6 kgf/sqcm fixed complete to WHB and kitchen sink includding socket & screw complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 40mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm fixed to wall, laid in floors for drain out the waste water from Kitchen Sink, WHB etc complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S & F in repair vitreous china wash down water closet padestal pattern white (excluding fixing bolts, flushing cistren and flush pipe) with 'P' or 'S' trap complete all as specified and directed by Engr-in-Charge. Make : Kerovit cat part No Jupiter KS114 or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F Plastic water closet seat cover, closed pattern with flat bottom with cover and mild steel chromium plated or aluminisied hinges devices complete all as specified and directed by Engr-in-Charge. Make : Kerovit cat part No KS2100 or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repair PVC valveless, syphonic action type, flushing cistern, low level, white 10 ltr capacity with inlet, ball valve, float and handle including brackets and polyethylene flush pipe complete all as specified and directed by Engr-in-Charge. Make: Model 'COMPASS' CAT Part No. B1020106 of CERA or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F chromium plated telephonic health faucet shower with flexible tube of stainless steel, 1.0 Mtr long & hook, multi flow 15mm dia for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge. Make- Cera CAT Part No. F 8030106AB or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Supply & Fixing in repair fancy type CP Towel rack 60 cm long complete all as specified and directed by the Engineer-in-charge. Make:- Kerovit cat part KA980010 or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repairs Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Demolition of RCC of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition and separating, scraping and cleaning of reinforcement and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Demolition of brick work or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work & precast concrete articles including copings etc.and removing debris outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for brick work with subclass B bricks straight or curved on plan exc. 6m mean radius, built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for brick work with subclass B bricks straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof kerbs, or mud stops, levelling coarse of roof, rounded of chamfered on edge, average thickness not exceeding 75mm complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repairs 20mm bore stainless steel curtain rod thickness not less than 1.0mm made of SS-304 with a perfect glossy mirror finish as approved complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repairs stainless steel fancy types domes cum brackets suitable for 20 mm dia curtain rod as approved and fixed to both ends with the curtain rod complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Taking down chowkats or frame exc 1.5 Sqm but n exc 4 Sqm each complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Taking down chowkat with shutters (without taking off shutters from the frames) area n.exc 1.5 Sqm each complete all as specified
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Taking down chowkat with shutters (without taking off shutters from the frames) area exc 1.5 Sqm but n.exc 4 Sqm each.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Taking down shutters of any description n exc 1 sqm each complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for second class hardwood (SAL) plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for preparing surfaces of wood and wood based materials and treating back of chowkats with tar or coal tar black paint, area tarred exc 0.1 sq. m but n exc 0.5 sq. m each complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for preparing surfaces of steel and iron work, and treating small articles such as holdfast with tar or coal tar black paint complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for MS work as in holdfast and similar articles conforming to grade Fe 410-0 and Fe 310-0 complete all as specified
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for Providing PCC 1:2:4, type B1(using 20mm graded stone aggregate) as in bed blocks for fixing hold fasts including necessary formwork complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M & L for cutting holes in brick /stone walls in cement mortar exc half brick & n.exc. One brick depth of embedded portion of hold fast and making good in cement concrete 1:2:4 type B1 or in cement mortar 1:3 and finished surfaces feven and smooth complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in copings, bed blocks etc including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Material & labour for powder coated aluminium sections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such as glazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified Note: - (i) Glass panes will be measured & paid separately. (ii) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as required but shall not be measured for arriving of weight. (iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area. (v) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for aluminium anodised powder coated grill DG-102 (aparture 80 x 66 mm) of M/S Deco grill with and including suitable size aluminium anodised F/H section frame as per manufacturers instructions complete all as specified and directed by Engr-in-Charge
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium wire staples to aluminium shutters complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 4mm thick figured glass pin headed type and glazing with aluminium and neoprene beads in square not exc 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 4mm thick plain sheet glass ordinary quality and glazing with aluminium and neoprene beads in square n. exc 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Supply and fixing 35mm thick factory made moulded PVC door shutter with 2, 4 or 6 raised panel design consisting of solid core single leaf flush shutter of 30mm thickness, lipped with 15mm (5mmx3) thick on one stiles and top rails & 10mm (5mm x 2) thick on other rail stiles and bottom rails, front face laminated with 2mm thick prelam or walnut colour PVC sheet in moulded design with 2, 4 or 6 raised panel and 2mm thick prelam or walnut colour PVC sheet on other side. PVC sheet having density 600kg/Cbm and should be termite proof, water proof & fire proof and fixing with the frame at site as per manufacturer specifications and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Supply and fixing PVC door frame of size 100mm x 45mm with a wall thickness of 5mm, made out of extruded 5mm prelam PVC sheet of density 600kg/Cbm, meter cut at two corners and jointed with 4 Nos of 150mm long brackets of 15x15mm MS square tube. The two vertical door frame to be reinforced with 40x20mm MS tube of 19 gauge through out the frame and fixing in opening as per manufacturer instructions and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 35mm thick second class hard wood factory made plain framed panelled shutters (two panes) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board medium density with commercial veneering both face. The size of rail shall be as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S & F 40 mm thick factory made flush shutters, solid core constrution with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S & F 25 mm thick factory made flush shutters, solid core constrution with block board core and plywood face panels, commercial type on both side complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F Second class hard wood factory made glazed and skeleton shutters 35 mm thick, open rebatede and prepared to receive glass, gauze etc (without sash bars), edge of framing plain chamfered of rounded, fitted with cut and mitred beads for securing glass etc. size of members of shutters shall be as specified in SSR Part I, section 8.20 (a) complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repair 18/19mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work including 18/19mm wide and 6mm thick teak wood lipping fixed to exposed edge with nails and glue to board as in cup board shutter, CB shelves,kitchen cabinate and like similar work complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repairs aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, wooden beedings to doors complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 100mm size stainless steel butt hinges medium weight with stainless steel hinge pin, bright finished (ISI Marked) complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
'-Ditto- all as per item No 111.00 above but fixed in repair.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F extruded aluminium alloy handles, fabricated type, anodised 125 mm size, ISI marked.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
'-Ditto- all as per item No 113.00 above but fixed in repair.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F aluminium anodised barrel tower bolts of extruded section, 150 mm length, ISI marked.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
'-Ditto- all as per item No 115.00 above but fixed in repair.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy, 300 mm long , ISI marked.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
'-Ditto- all as per item No 117.00 above but fixed in repair.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F Floor door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140 mm complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Ditto- all as per item No 119.00 above but fixed in repair.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F magic eye fancy type of brass for door including drilling, cutting of holes and making good complete all as specified and directed by Engr-in-Charge.
S&F magnetic door catcher including letting complete all as specified and directed by Engr-in-Charge.
S&F Continuous (piano) hinges, mild steel, bright finish or electro galvanised, width of flaps when open 30mm complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 125mm size hasp and staple safety type, aluminium anodised, ISI marked, including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for Preparation of new or previously untreated surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying one coat of pink primer and two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
M&L for preparation of old painted surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 18 mm thick Rajshri Celuka ply or equivalent of Plain color fixed with screws, solvent cement/ adhesive to make kitchen cabinet, sides, top and bottom and shelves inside the cabinets complete as per manufacturers specifications and as directed by Engr-in-Charge. Note :- Work shall be carried out up to 14th floor.
S&F 18 mm thick Rajshri Celuka ply or equivalent of one side Prelam/Rigidlam and other side plain white colour to make kitchen cabinet Shutter/ drawer, Front shutters in double panel complete as per manufacturers specifications and as directed by Engr-in-Charge. Note :- Work shall be carried out up to 14th floor.
S&F auto closing hinges openable at 0/90 degree for kitchen cabinet shutters complete as per specifications and as directed by Engr-in-Charge. Make- Hettich, Ebco, Prime Note :- Work shall be carried out up to 14th floor.
S&F stainless steel handles 100 mm size complete as directed by the Engr-in-Charge. Make- Hettich, Ebco, Prime Note :- Work shall be carried out up to 14th floor.
S&F 40mm bore GI pipe medium grade with all fittings fixed in to walls and ceilings or laid in floors as sleeve/spout including making hole in wall/floor and sealing the sides with epoxy mortar complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Taking down CI soil/waste/vent/rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 100 mm bore CI soil/waste/vent pipe, sand cast, in any length with ears with cement joints fixed to walls with suitable size GI clamps spacing 1.5m c/c as per CE (Navy) mumbai TD No :TD/2023/01 complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 100 mm bore CI soil/waste/vent pipe, sand cast, in any length with ears with cement joints laid in trenches or in floors complete all as specified and directed by Engr-in-Charge.
S&F 100 mm bore CI bends (any radius) with oval access door, diminishing pieces or tapers fixed to walls with suitable size GI clamps complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 100mm bore CI branch pieces single 'Y', 'T' (equal or unequal) ordinary or inverted (spigot or socket type) with parallel branches with ovel access door complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 75 mm bore CI soil/waste/vent pipe, sand cast, in any length with ears with cement joints fixed to walls with suitable size GI clamps spacing 1.5m c/c as per CE (Navy) mumbai TD No :TD/2023/01 complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 75 mm bore CI soil/waste/vent pipe, sand cast, in any length with ears with cement joints laid in trenches or in floors complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 75 mm bore CI bends (any radius) with oval access door, diminishing pieces or tapers fixed to walls with suitable size GI clamps complete all as specified and directed by Engr-in-Charge.
S&F 75mm bore CI branch piececs single 'Y'.'T' (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F in repairs Salt-glazed stoneware gully traps, square or round mouthed 150mm x 100mm including jointing to pipe complete all as specified and directed by Engr-in-Charge.
S&F 75mm bore Cast iron vent cowls fixed with cement joints complete all as specified and directed by Engr-in-Charge. Note :- Work shall be carried out up to 14th floor.
S&F 100mm bore Cast iron vent cowls fixed with cement joints complete all as specified and directed by Engr-in-Charge. Note :- Work shall be carried out up to 14th floor.
S&F 75mm bore cast iron sanitary connection socket of suitable length to connect with Trap to out-let of pipe line complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
Taking down PVC rain water pipes including all fittings like shoes, bends, swan necks etc of any dia complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F PVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints fixed to wall with suitable size GI clamps & spacing 1.5m c/c as per CE (Navy) mumbai TD No :TD/2023/01 complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F 160 mm bore PVC (SWR) bends (any radius),diminishing pieces or tapers on walls complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F PVC covers to MS railings of stair case hand rail complete all as specified and directed by Engr-in-Charge.
S&F for stainless steel cloth hanger peg set of 6 of premium quality fixed with CP brass screws complete all as specified and directed by Engr-in-Charge.
Supply and fixing 04 piece pulley operated Cloths Drying system casting of Aluminium pipe of outer dia 22 mm inner dia 19.8 mm and channel pair of length 2.50 mtr with pulley made up of Devil mounted and fixed with self tapping screw. Rope shall be HDPE double core of 4 mm with rope Guide at locking system to hide rope, minimum weight of pipe shall not be less than 0.20 kg/Rm and maximum weight of pipe in one unit not less than 2 kg. Weight of rope shall be not less than 550 gms / mtrs. Make : Easy dry or equivalent.
S&F in repairs stainless steel kitchen plate rack made out of 0.63mm thick sheet of size 30" x 36" x 9" of approved pattern & make and weight not less than 8.0 Kg each fixed to wall with CP brass screws complete all as specified and directed by Engr-in-Charge.
S&F number plate made out of 3mm thick acrylic sheet of size 100mm x 180mm including 3 numeric letter of height not less than 65mm (colour, design & pattern as approved by EIC) fixed with CP brass screws complete all as specified and directed by Engr-in-Charge.
S&F prefabricated cast iron work grade FG 150, unmachined in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors. dampers, stop valve boxes, baluusters and similar works (weight of each articles exceeding 5 kg) complete all as specified and directed by Engr-in-charge.
M&L for Excavation in over areas and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
M&L for hardcore of broken stone or boulders of gauge n. exc 63mm, deposited, spread and leveled in layers n. exc 15cm thick watered and rammed to true surface complete all as specified.
M&L for 100mm thic PCC 1:3:6 type C2 ( using 40mm graded stone aggregate) as in sub base to floors, pavements etc complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete colour interlocking tiles 60 mm thick having glossy finish/(colour and pattern as approved by GE) strength not less than 350 Kg/ Sqcm laid over and including 50 mm thick dry sand cushioning and void filled with dry and compact, including compation by means of surface vibrator, complete all as specified and directed by Engr-in-Charge.
Taking down carefully existing FRP chajja 60cm to 120cm wide and refixing after repair work with and including through fastner of adequate size as approved by GE complete all as specified and directed by Engr-in-Charge.
M & L for providing & fixing factory made Fibre glass Reinforced Plastic (FRP) "chajja"- 4mm thick of "fibreways" brand in required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology available with laminated single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 Nos vertically and 1 No horizontally 50x2mm thick MS Flat with 12mm in built hole for grouting on the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete in one single piece casted monothically including all necessary fittings. Molded with unsaturated Polyster resin as per IS: 6746 duly reinforced with fibreglass chopped strand mat (CSM) as per IS: 11551. Available with protective gel coat U/V coating on top for complete resistance from the extreme of temperature, weather & sunlight fixed with and incl through fastner of adequate size (as approved by GE) complete all as specified and directed by Engr-in-Charge.
M & L for Structural auditing after repair work with photo graphy to assess the structural position, Non destructive test with Ultrasonic pulse Velocity test, Rebound Hammer test, cover meter test for RCC structure, chemical test, Half cell Potential and Carbonation Test , Core cutting & Compression test, Slab deflection Test, Verticality Check, stability checks , to check and confirm present status of structure on basis of NDT Results. The report alongwith photographs duly vetted by IIT/ government Engineering College shall be submitted to GE for records. Note : All tests shall be carried out by authorised firm /agency according to relevant IS and work has to be carried out up to G+14 floors
S&F Stainless Steel crome Finish Shop Dish wall mounted complete all as specified. Make : Kerovit cat part No KA670004 or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F Sheet Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F Sheet Corner Glass shelf assembly 8" x 8" (Oval Range ) with chromium plated bracket guard complete all as specified. Make : Kerovit cat part No KA920009 or any other equivalent makes mentioned in Particular Specifications.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall with suitable size GI clamps & spacing 1.5m c/c as per CE (Navy) mumbai TD No :TD/2023/01 complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wall with suitable size GI clamps & spacing 1.5m c/c as per CE (Navy) mumbai TD No :TD/2023/01 complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
S&F for 75 mm bore PVC (SWR) branch piece (Y or T),any radius, diminishing pieces or tapers complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
Height 5th floor to upto and including 8th floor.
Height 9th floor to upto and including 12th floor.
Height 13th floor to upto and including 16th floor.
SCHEDULE 'A' PART II (WATER SUPPLY) Taking up or down GI tubing including all fitting and fixtures fixed to wall including breaking the existing brick wall for complete all as specified and directed by Engineer-in-Charge. :-
80 mm bore
40/50 mm bore
25 mm bore
20 mm bore
15 mm bore
Supply and Fixing of steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall in shafts including up to 15 th floor in high rise buildings in short piece/any length, and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge. Note - Work shall be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length.
80 mm bore
50 mm bore
40 mm bore
25 mm bore
20 mm bore
15 mm bore
Supplying and laying of CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings in trenches including taking down of old u/s GI Pipe complete complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified and directed by Engineer-in-Charge.
15 mm bore
20 mm bore
40 mm bore
50 mm bore
80 mm bore
S & F in repairs 25 mm bore bronze, pressure, reducing valve screwed ends suitable for a maximum inlet pressure of 20 Kg/ Sqcm reduced to 0.5 to 5.5 Kg/Sqcm valves incorporates inherent design advantages like noise free working, an metal construction, reversible double re-inforced food grade EPDM rubber (Colour coding Black) Diaphram cover, stainless steel bolts etc valve are calibrated for a maximum inlet pressure of 20 Kg/ Sqcm complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs 15 mm bore Stop valves, cast copper alloy fancy type, chromium plated with long shank and cup washers (Concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 15 mm bore bib taps cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 15 mm bore bib taps cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed suitable for washing machine complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 15 mm bore Stop valves, cast copper alloy fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 15 mm bore two way bib taps cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs PVC loft tank (LDPE) of capacity 275 ltrs with complete fittings i.e 03 Nos adopter with washer for inlet/outlet,over flow as per manufactureres instructions including brass float valve 15 mm bore complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs PVC profile suitable for 275 ltrs loft tank including fixing of aluminium channel around the profile complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for .
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
S&F in repairs Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) Complete all as specified and directed.
Supply, Installation, Testing & Commissioning in repair Motor Actuated Ball Valve consisiting of suitable single phase Actuator and ball valve of size 40/50 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Material of Ball: Stainless Steel Limit Switches : 02 Nos.For open and close status Mounting :Direct on valve
Supply, Installation, Testing & Commissioning in repair Motor Actuated Ball Valve consisiting of suitable single phase Actuator and ball valve of size 80 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Material of Ball: Stainless Steel Limit Switches : 02 Nos.For open and close status Mounting :Direct on valve
Supply, Installation, Testing & Commissioning in repair Float type Point Level Sensor with the following specifications; Type: Magnetic, Magnet: Ring type, Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon
Supply, laying,connecting & testing in repairs 6 core x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper conductor cable laid in trenches / fixed on wall with suitable size GI clamps complete all as specified and directed by Engr-in-Charge.
Supply, laying,connecting & testing in repairs 5 pair 0.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper conductor cable laid in trenches / fixed on wall with suitable size GI clamps complete all as specified and directed by Engr-in-Charge.
Taking down carefully without any damage SCADA control panel-01 No, motorised valves-16 Nos before starting the special repair work and kept in safe custody and refixing at existing location as directed and testing after completion at site all as specified and directed.
M&L for taking down carefully and re-fixing after servicing of Motor Actuated Ball Valve consisiting of suitable single phase Actuator and ball valve of size 40/50/80 mm dia complete all as specified.
M&L for taking down and re-fixing after servicing Float type Point Level Sensor with the following specifications; Type: Magnetic, Magnet: Ring type, Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon
S&F in repairs SMC PANEL TANK ISI Marked and have ISI Logo with CML and Batch Number along with ISI Code (ISI 14399 Part-1 & Part-11-2006) of size 3000mm x 2000mm x 2000mm and capacity 12 KL.) Made out of HOT PRESS MOULDED SHEET MOULDING COMPOUND (SMC) Panels of size 1005mm X 1005 mm. The flange should be perpendicular to the main surface. The shape should be Trunk Type for extra strength and 90 degree flanges predrilled for bolting. All the Flanges of the Panel should have maximum 13 Nos. holes for fastening/joining the panels to one another. Hot Pressed Moulded SMC Pre Drilled Corner Pieces with built-in ribs of the size 75mm X 75 mm should be provided for 90 degree joints of tank walls or wall to base or wall to roof joints complete Hot Dipped Galvanized (HDG) hardware nuts, bolts and washers. Special sealant having excellent UV Resistance as well as suitable for portable water, complete with Top Covered construction having Man-Hole with Cover of Dia 600mm and internal FRP Ladder. The tank after erection and assembled as per Manufacturer Specification's shall be filled with water upto overflow level, which will be placed near the roof of the tank and test for leakages rectified any leakage found during the testing should be rectified to make it 100% leak proof complete as per direction of Engineer-in-Charge. (ISI Logo & CML number must be printed on all Panels). Make : Sintex Code No GS-PT-010-S2.5 or equivalent model of make in M/s BT composite Ltd / M/s Mahindra composite Ltd. NOTE: (i) Rate quoted shall deemed to be inclusive of internal and external ladder made out of GRP/ Pultruted Section and necessary modifications to RCC foundation. MS supporting channels and necessary PVC profile including foundation, grillage, unloading, shifting & other civil work as per manufacturers instruction..
S&F in repairs rotational moulded polyethylene water storage tank 1000 Ltr capacity, 3 layers, ISI marked (cylindrical vertical with closed top) including all connections for inlet, outlet, overflow and washout etc and hoisted and fixed in position over PCC 1:2:4 type B1 foundation not less than 30 cm height complete all as specified and directed
Supply and fix in repairs brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 50 mm bore including necessary GI fittings such as elbow, reducer, nipple etc. complete all as specified and directed
Supply and fix in repairs brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15 mm bore including necessary GI fittings such as elbow, reducer, nipple etc. complete all as specified and directed
Supply and fix in repairs 3-layer PP-R Polypropylene random copolymer) concealed pipes 110 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed to walls, ceilings with suitable size GI clamps or laid in floors complete all as specified and directed
Supply and fix in repairs 3-layer PP-R Polypropylene random copolymer) concealed pipes 50 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed to walls, ceilings with suitable size GI clamps or laid in floors complete all as specified and directed
Supply and fix in repairs of 3-layer PP-R Polypropylene random copolymer) concealed pipes 25 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings to walls, ceilings with suitable size GI clamps or laid in floors complete all as specified and directed
Supply and fix in repairs of 3-layer PP-R Polypropylene random copolymer) concealed pipes 20 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings ffixed to walls, ceilings with suitable size GI clamps or laid in floors complete all as specified and directed
Supply and fix in repairs PP-R gate valves 110 mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in repairs PP-R gate valves 50 mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in repairs PP-R gate valves 20 mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
SCHEDULE 'A' PART IlI (INTERNAL ELECTRIFICATION ) Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc removing and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed. Note: Serviceable tube lights shall be kept under safe custody and refixed as directed.
M & L for point wiring with 1.5 sqmm single core multistranded FRLS PVC insulated, sheated copper conductor cable,1100 volts grade conforming to IS- 694:1990 drawn through and including rigid non-metallic PVC conduit medium grade ISI marked with all accessories concealed in wall/ floor and terminated in and including concealed PVC modular metal box with modular white cover plate with frame of sutable size including one FRLS PVC insulated and sheathed multistanded copper conductor cable 1.5 sqmm as earth continuity conductor connected to common earth dolly for the following :- Note : - i) Circuit conductor from MCB DB to Switch boards shall not be less than 2.5sqmm for (a) swich boards having light/fan points and 6A socket in common circuit. (b) socket outlets 6A mounted on Independent switch board. ii) Modular metal flush box shall be measured and paid seperately under relevant items of this schedule. iii) In colum/beam/ceiling portion surface wiring should be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iv) The work shall be carried out conforming to IS-732:1989. v) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. vi) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
One light/Exhaust fan/Ceiling fan point controlled by one switch SP one way.
One light point controlled by two-way switch.
One 3 pin socket combination 6 Amps on same board.
One 3 pin socket combination 6 Amps on independent board.
One bell point controlled by one push button 6 Amps on independent board.
M & L for point wiring with 2.5 sqmm single core multistranded FRLS PVC insulated, sheated copper conductor cable,1100 volts grade conforming to IS- 694:1990 drawn through and including rigid non-metallic PVC conduit medium grade ISI marked with all accessories concealed in wall/ floor and terminated in and including concealed PVC modular metal box with modular white cover plate with frame of sutable size including one FRLS PVC insulated and sheathed multistanded copper conductor cable 2.5 sqmm as earth continuity conductor connected to common earth dolly for one 3 pin socket outlet 15 Amps on the independent board. Note:- i) Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. ii) Separate circuit shall be drawn from MCB. No taping from light circuit shall be allowed. iii) Modular metal flush box shall be paid separately under relevant items of this schedule. iii) In colum/beam/ceiling portion surface wiring should be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iv) The work shall be carried out confirming to IS-732:1989. v) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. vi) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
S & F modular switch, 6 Amps , One way, one module , ISI marked complete all as specified and directed.
S & F modular type bell push 6 amps 1 module, ISI marked complete all as specified and directed.
S & F modular switch, 16 Amps , One way, one module , ISI marked complete all as specified and directed.
S & F bell electric AC 230 Volts single pole ding dong with ISI marked complete all as specified and directed.
S & F modular socket, 6 Amps , 2/3 pin combined , two module , ISI marked complete all as specified and directed.
S & F modular socket, 16 Amps , 6 pin combined , two module , ISI marked complete all as specified and directed.
S & F modular socket, 10/20 Amps , 6 pin, two module , ISI marked complete all as specified and directed.
S & F modular DP switch, 20 Amps , One way,two module, ISI marked complete all as specified and directed.
S & F modular switch, 6 Amps ,two way, one module , ISI marked complete all as specified and directed.
S&F modular TV Socket including flush box and cover plate with frame
S & F ceiling rose surface bakelite with ISI mark , flush type three terminals complete all as specified and directed.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply & Fixing Retrofit LED lamp 12 Watts complete all as specified and directed by Engineer-in-Charge.
S & F modular stepped type fan regulators 2 module, 120 W, 230 volts ISI marked complete all as specified and directed.
S & F modular metal flush box of following modules flushed in wall and making good surface complete all as specified and directed.
1- Module or 2- Module
3- Module
4- Module
6- Module
8- Module
S & F modular white cover plate with frame of following modules complete all as specified and directed.
1- Module
2- Module
3- Module
4- Module
6- Module
8- Module
Supply and fixing integrated LED batten 20 Watt, not less than 120 watt/lumen, 4 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting alongwith provision of two Nos of PVC box of size 75 x 75 x 20mm for mounting light fittings complete all as specified and directed.
Supply and fixing integrated LED batten 10 Watt, not less than 120 watt/lumen, 2 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed.
S&F 10W LED batten with inbuilt smart motion sensor, not less than 120 watt/lumen, 230 Volt , 50 Hz , 2 feet, polycarbonate extruded channel, with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed.
S&F in repairs MCB DB SPN 12 way suitable for single phase AC supply, 230 V sheet steel powder coated enclosure double door type with minimum IP-43 degree of protection with built in 100 Amps copper bus bar, neutral link and earth link complete including flush off in wall with cutting and making good the disturbed surface including connection of circuits with copper pin terminals complete all as specified and directed. Note :- Blanking plate shall be used for blank places in DB.
S&F in repairs MCB SPN, 32 Amp, ISI marked, 30mA, 230V DP RCBO for AC applications, conforming to IS:12640 (Part2)-2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP20 protected lower terminals and sliding shutters complete all as specified and directed
S & F in repairs MCB, single pole, 6 to 32 Amp, 10KA, 230Volt, “C” curve.
M&L for submain wiring with PVC insulated, PVC sheathed, armoured, FRLS 1100 V grade, 3 core 6 sqmm stranded copper conductor fixed on wall/ roof/duct and connecting from meter to DBs with suitable size copper glands including taking out existing damaged cables complete all as specified and directed.
M&L for sub-main wiring with 2 runs of 4 Sqmm PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990, drawn through and including rigid non-metallic medium grade ISI marked PVC concealed conduit with accessories such as Bends, Tees, Elbows,coupler etc including one run of 4 Sqmm dia PVC insulated and unsheathed multi-stranded copper conductor cable (FRLS grade), 1100 volts grade, ISI marked conforming to IS- 694:1990 as earth dolly/mains connected with thimble from main DB to sub main DB including taking down existing submain wiring and making good distrubed surfaces as per existing complete all as specified and directed. Note: (i) 03 Runs x 4 Sqmm copper cable for phase, neutral & earth and 01 run of PVC conduit shall be measured as 01 RM. ii) In column/beam/ceiling portion surface wiring shall be considered with & including suitable size of casing capping as directed by Engineer-in-Charge. iii) The work shall be carried out conforming to IS-732:1989. iv) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green. v) Cutting chases, pinning in, making good to facings required for concealed conduit wiring shall be deemed to be included in rate quoted
Supply and fixing in repairs BLDC ceiling fans of latest valid lable period complete with blades, down rods and accessories , 230 volts, 50 Hz,1200mm sweep (48"), minimum air delivery 210 CFM with service value 6.0 BEE Five star rated with brushless direct current motor (BLDC) alongwith steel wire rope additional safety in ceiling fan including connecting up with three core flexible copper conductor cable for suitable size complete all as specified and as directed. Note :- Old ceiling fan shall be handed over to MES Stores.
Taking out unserviceable Exhaust fan and Supply and fixing Exhaust fan, metallic blade, heavy duty, double ball bearing, 230 Volts, 50Hz, 300mm sweep having power input 70W speed 1440 RPM including connection as required at site with flexible copper conductor cable of suitable size, complete all as specified and as directed. Note :- Old exhaust fans shall be deposited to MES Stores.
Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32mm x 6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, 50mm thick precast cement concrete cover 1:2:4 type B1 including XPM jali not less than 4Kg per Sqm as reinforcement with 6mm dia MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40mm x 40mm x 4mm, including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point complete all as specified including testing on completion. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point.
S&F in repairs PVC insulated armoured cable three core 4.0 Sqmm with aluminum conductor for connecion from DB/timer to connector of junction box for power supply to security light fittings fixed on wall using SS clamps/saddles at suitable intervals as directed by Engineer-in-Charge.
S & F in repair junction box of size not less than 100mm x 100mm with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified.
S&F in repairs security light bracket bend to shape as required of 32mm bore GI pipe light grade, 1.5 mtr length, fixed to pole/ Wall including using flat iron clamp with the help of nuts and bolts complete all as specified and as directed.
Supply and fixing in repairs LED street light fitting 35 Watt, not less than 125 lumen/ watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified.
M & L for snap-on PVC trunking system with cover, angles, bends and all accessories and fitting of size not less than 50mm x 80mm fixing on wall with suitable size CP screws complete all as specified and directed.
Supply and fix in repairs fixed type lours made out of 1.6 mm GI sheet with horizontal ventilation, bending to shape of size 45cm x 45cm(outer) complete by providing of fixing arrangement for louvers upto 15th floor complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by Engineer-in-Charge. Note :- Old exhaust fans handed over to MES Stores.
S & F in repairs Analog Timelite distribution board 16A, 3 pole, 230 Volt with contactor, relay and prewired with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as specified and directed
Taking out old unserviceable meter LT Panel and Supply, installation, testing and commissioning meter cabin panel mounted on angle iron frame 40 x 40 x 5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of CRCA sheet not less than 2 mm thick , vermin proof, factory fabricated, CPRI approved, front open hinged door with locking arrangement duly powder coated, individual compartment for MCCBs and 250 Amps rated copper bus bar alongwith compartment for fixing of 30 Nos electronic smart prepaid meters, top and bottom cable entry with suitable size copper glands including provisions of vision glasses for meter readings as directed. Meter cabin panel shall be comprising of the following :- (a) MCCB 4 pole, 160 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 No (Incomer) (b) MCCB 3 pole, 125 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 No (Outgoing for meter panel) (c) MCB SPN 32 Amps 10 KA - 31 Nos (d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH - 1 No. (e) Phase indicator lamp R,Y & B - (01 Set of three). (f) Copper Bus bar, 250 Amps Rated - R,Y,B & N - (01Set of four) including provision of new vision glasses-30 Nos. (g) Submain cable 3 core 6 Sqmm copper conductor from MCB SPN to electronic meter. (h) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel contractor has to take approval of drawing from GE (ii) All existing cable connections shall be disconnected from old Panel carefully and re-connected with new Panel by providing copper glands and thimble all as directed by Engineer-in-Charge. (iii) All existing meters will be disconnected & removed from old Panel carefully and refixed & re-connected in new Panel all as directed by Engineer-in-Charge.
Taking out old unserviceable meter LT Panel and Supply, installation, testing and commissioning of meter cabin panel mounted on angle iron frame 40 x 40 x 5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of CRCA sheet not less than 2 mm thick , vermin proof, factory fabricated, CPRI approved, front open hinged door with locking arrangement, duly powder coated, individual compartment for MCCBs and 200 Amps rated copper bus bar alongwith compartment for fixing of 29 Nos electronic smart prepaid meters, top and bottom cable entry with suitable size copper glands including provisions of vision glasses for meter readings as directed. Meter cabin panel shall be comprising of the following :- (a) MCCB 4 pole, 125 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 No (Incoming) (b) MCB SPN 32 Amps 10 KA - 30 Nos (c) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH - 1 No. (d) Phase indicator lamp R,Y & B - (01 Set of three). (e) Copper Bus bar, 200 Amps Rated - R,Y,B & N - (01Set of four) including provision of new vision glasses-29 Nos. (f) Submain cable 3 core 6 Sqmm copper conductor from MCB SPN to electronic meter. (g) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel contractor has to take approval of drawing from GE (ii) All existing cable connections shall be disconnected from old Panel carefully and re-connected with new Panel by providing copper glands and thimble all as directed by Engineer-in-Charge. (iii) All existing meters will be disconnected & removed from old Panel carefully and refixed & re-connected in new Panel all as directed by Engineer-in-Charge.
M & L for Rigid non-metallic medium grade PVC conduit ISI marked not less than 20mm dia concealed in wall inclusive of boxes (junction/ terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed. (For TV cable)
M & L for Rigid non-metallic medium grade PVC conduit ISI marked not less than 25mm dia concealed in wall inclusive of boxes (junction/ terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed. (For AC Socket Wiring From SPN DB to AC Socket)
SCHEDULE 'A' PART IlI (FIRE FIGHTING ) Supply, installation, testing & commissioning in repairs micro processor based 2 wire fault tolerant loop, required loop networkable type single loop (each loop accessing maximum 99 detectors & 99 modules upto 200 detectors ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address. The panel shall have rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address. The panel shall have a built in power supply and battery charger alongwith maintenance free 7.2 AH, 2x12 volt SMF lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required and as per specifications duly approved by EN 54 complete including of all 15 Amp power point connection from meter room to fire control panel complete all as specified and directed by Engr-in-Charge. Make : Morley-IAS by Honeywell model Name/Number DXc2/714-001-225 or Bosch model NO FPA-1000-V2/Schneider cat No FFSULH1002 Model No ESM, ULTIMA.
Supply & fix in repair single headed outlet hydrant valve 100mm, ISI marked, having 63mm outlet with lock pin wheel complete all as specified and directed.
Supply & fix in repair double headed outlet hydrant valve 100mm having 63 mm outlet with lock pin wheel, ISI Marked complete all as specified and directed.
Material and labour for factory fabricated Hose box made of 18 gauge MS Sheet of size 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge suitable for fitting two nos hose pipe of length 15 mtr each, branch pipe (nozzle) coupling etc duly painted with synthetic enamel paint fire red out side and brilliant white inside yard fixed on wall with necessary nuts/bolts or welding to existing MS pipe by supporting angle complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs branch pipe stainless steel nozzle of 20 mm x 63mm dia for canvas hose pipe conforming to IS 8090 complete all as specified.
Supply and fix in repair 63 mm dia 15 meter long hose pipe conforming to IS 636 with stainless steel male and female coupling conforming to IS 903 complete all as specified.
Supply & fix in repair hose Reel drum swivel type suitable for and including 30 mtrs X 20 mm dia rubber hose pipe conforming to IS-884 complete all as specified and directed.
Supply and fix in repairs branch pipe with nozzle (Shutoff ) of 20 mm dia for hose reel conforming to IS 8090 complete all as specified.
Supply & fix in repair detectors complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed. Note :- Loop cards, circuits as required to make functional is deemed to be included in the item rate and no extra will be paid to the contractor.
Supply and fix in repairs SS fire brigade inlet connection for connected external fire hydrant ring main consisting of two Nos 63 mm dia instantaneous type male coupling with built in check valves and 100 mm dia, flanged outlet complete with all accessories.
Supply, Installation,Testing & Commissioning in repairs Addressable Type Manual Call Point resettable type complete all as specified and directed.
Supply, Installation, Testing and Commissioning in repairs Addressable electronic sounder cum strobe complete all as specified and directed.
Supply, laying and testing in repairs PVC insulated, PVC sheathed cable galvanized steel strip or wire armed, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sq mm , 2 core, 1100 volts grade complete all as specified.
S&F in repair Sluice valves flanged end, cast iron body, flanged and drilled and rising type Steel spindle with nut, long body, class P N 1.6, 100 mm (4") size conforming to IS 14846 of 2000 for following sizes in any position/location including all flange joint with rubber or fiber board gaskets, bolts, nuts, washers, welding etc complete including pumping out accumulated water complete all as specified and directed. Note :- For Additional manpower, welding, chipping, plastering and any other item required for replacement of the item including making good the disturbed surfaces are deemed to be including in the item rate and no extra payment shall be paid.
-Ditto- all as per item no 257.00 but of size 150 mm (6”) dia
Supply and fix in repairs MS ERW flanged pipe 100mm NB heavy duty including all fittings such as elbow, bend, socket, tee, tail piece with welding work, threading including painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer inmulti storied building duly complete all as specified.
Supply and fix in repairs MS ERW flanged pipe 150mm NB heavy duty including all fittings such as elbow, bend, socket, tee, tail piece with welding work, threading including painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer inmulti storied building duly complete all as specified.
M & L for construction of brick masonry valve chamber of size 1200mm x 1200mm x 1200mm (internal dimension) (above GL 0.30 mtr) comprising of 15cm thick PCC 1:4:8 type D-2 foundation over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster, top of floor 15mm thick in cement and sand mortar 1:3 finished even and smooth without using extra cement, 5 mm thick MS plate cover over complete chamber fixed on 50mm x 50mm x 6mm MS angle frame welded to MS hold fasts embeded in 50mm thick 1:2:4 type B-1 coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including necessary excavation and earth work in any type of soil and demolition of existing valve chamber and removing debries outside MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
S& F rolled mild steel in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe 410-W(GdeE- 250) quality A complete all as specified and directed by Engineer-in-Charg. Note- Cost of making necessary holes in wall for fixing iron section and making good the disturb surfaces using cement and sand mortar (1:3) is deemed to be including in the rate quoted.
Excavating in trenches n exc 1.5m wide & n exc 1.5m in depth; for foundation, etc. or for manholes n.exc.10 Sqm on plan and n.exc.1.5m in depth and getting out in soft/loose soil complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified.
Removing excavated material exc 250 M but n.exc 500 M and depositing where directed complete all as specified.
Supply and laying in repair of spigot and socket ductile iron water tubing, class K-9, cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/ in trenches, cutting, jointing of colar/flange, welding (if required) with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed of following size .
150mm bore
100mm bore
80mm bore
ASHOK CONSTRUCTION (BID ID -3294404)
S S ENTERPRISES (BID ID -3292300)
AGRAWAL ASSOCIATES (BID ID -3293359)
Sunbud Multiventures Private Limited (BID ID -3293986)
Garima Construction Co (BID ID -3294443)
Shetty Construction Co (BID ID -3294540)
MUKESH CONSTRUCTION CO (BID ID -3294571)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .