Combined Package- Providing intermediate tower between T.Nos 06-09 in existing 66KV Jalamangala- Melehalli SC line, 66kV Kanakapura-Chikenahalli-Channapatna SC line between T.Nos 43-44 and 66kV Kothipura-Ramanagara SC line (proposed 220/66KV MCMV line to Kothipura) between T.Nos 09-10 using 66kV KPTCL designed Narrow based tower with COYOTE ACSR conductor in TL&SS Division Kanakapura on TTK/PTK basis
KPTCL/2024-25/TL/WORK_INDENT930
KPTCL/2024-25/TL/WORK_INDENT930
Open
Transmission Line
Two Tender Document System(Two Cover)
KPTCL SEE Transmission And Mantainance Ramanagara Circle
4 documents required · 0 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Should have carried out erection of all connected equipments of (01) One Transformer Bay/ erection of One Transmission line tower / One Terminal Bay of 110/66KV class or above voltage class on Total Turnkey or Partial Turnkey basis, which shall be in satisfactory service for a period of One year prior to date of submission of the Bid
others
The bidder shall enclose audited annual turnover statement certified by CA not less than. Rs.1,16,62,310/- during the preceding three years
₹1,460
₹58,315
4 Jul 2024
4 Jul 2024
29 Jul 2024
11 Jul 2024
Combined Package- Providing intermediate tower between T.Nos 06-09 in existing 66KV Jalamangala- Melehalli SC line, 66kV Kanakapura-Chikenahalli-Channapatna SC line between T.Nos 43-44 and 66kV Kothipura-Ramanagara SC line (proposed 220/66KV MCMV line to Kothipura) between T.Nos 09-10 using 66kV KPTCL designed Narrow based tower with COYOTE ACSR conductor in TL&SS Division Kanakapura on TTK/PTK basis
Fabrication,Galvanising and Supply of Tower Parts 66KV DC Narrow Based Tower KPTCL Design-DD+0-1no 2) DD+6-2nos -Total Weight of Towers including stub.(Note:22/66KV MCMV-MA+3 VTP design will be s...
Galvanized bolts & nuts for above
Suplly of Number Plates
Suplly of Danger Boards
Suplly of Circuit plate
Suplly of Phase plate (set of 6 per tower)
Suplly of Earth bond 450 mm long
Supply of ACSR Conductor as per KPTCL Specification-COYOTE ACSR
Supply of 66kV Polymer Disc Insulator
Supply of Double Tension clamps along with hardware for coyote ACSR and arcing horn
Supply of Single Tension clamps along with hardware for coyote ACSR and arcing horn
Supply of Single Tension clamp (bolted type) suitable for Ground conductor
Supply of M S C Joints suitable for Coyote ACSR
Supply of Vibration dampers for Coyote ACSR conductor
Supply of C type fire wedge connector suitable for Coyote to Coyote
Supply of Ground conductor
Supply of PG Clamps suitable for Ground ACSR
Supply of Single Suspension clamps along with hardware for coyote ACSR and arcing horn
Check survey using ther own equipment for 66kV Plain terrain
Assembling and erection of towers including tightning of bolts and nuts ( including loading , unloading at store and site)
Sorting of tower parts made out of fabricated angle iron
Setting of stub templates and aligning dismantling and transportation of templates from one location to another location for 66kV
Supplying and fixing GI angle 450 x 450 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5 mts length each at inner and outer surface of tower to facilitate running of b...
Supplying and fixing Barbed wire
Fixing of Number Plates
Fixing of Danger Boards
Fixing of Circuit plate
Fixing of Phase plate (3 Nos/Set)
Earthing :- Grounding of tower including cost of 40mm dia 2.5mm Thick class GI pipe of 3 mtr length as per specification with 50x6 mm GI flat 3 mtr long salt, charcoal , including excavation charges
Supplying and fixing of counter poise earthing with GI standed wire where hard rock is enclundted as per
Tack welding of Bolts and Nuts (No of tower x 500)
Dismantling of existing Towers
Loading and Unloading of released materials
Transportation of above released materials to Stores, Peenya using 10MT lorry
Stringing of Coyote ACSR conductor plain terrian
Stringing of Ground conductor plain terrian
Stringing of Ground conductor plain terrian
Releasing & restringing of the Coyote ACSR conductor in the existing line
Releasing & restringing of the Ground conductor in the existing line
Releasing & restringing of the Ground conductor in the existing line
Releasing of Coyote conductor in the existing line
Releasing of Ground conductor in the existing line
Releasing & restringing of the OWL ACSR conductor in the existing line
Excavation of earth as per specification & approved drawing for the tower foundation (DFR/SR) by mechanical means for all works & depth upto 3 metres as per drawing and techical specifications
Excavation of earth as per specification & approved drawing for the tower foundation (in all types of soils with watery condition) by mechanical means for all works & depth upto 3 metres as per drawin...
Concreting of 1:1.5:3(M20) with formbox to be supplied by the contrctor. M20 design Mix using 20mm norminal size graded crushed coarse aggregates .
Concreting of 1:3:6(M10) with formbox to be supplied by the contrctor. M10 design Mix using 20mm norminal size graded crushed coarse aggregates .
Steel fabrication: Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, striaghtening, cutting,bending, hooking, laping/weld...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Combined package-TLM.zip
Tender Document • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].