Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹8.7 L+₹34,050 (4.09%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance not lowest | |
| 3 | L3₹9.0 L+₹62,555 (7.51%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-Finance not Lowest | |
| 4 | L4₹9.3 L+₹94,665 (11.4%)Rejected-Finance NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L4 | Rejected-Finance not Lowest |
Tender Value
₹10.0 L
EMD Value
₹19,940
Closing Date
14 Jun 2023, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI
REPAIR AND MAINTENANCE OF DUCTABLE ACS, PLANT PUMPSET VALVES STARTERS AND CONNECTED WORKS AT CVRDE AVADI
2023_MES_596325_1
8558/E8
Open Tender
Civil Works
Item Rate
240 days
AVADI
As per Tender Documents
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,940
Yes
20 Jul 2023
18 May 2023
16 Jun 2023
18 May 2023
14 Jun 2023
1 Jun 2023
Amount
M&L for general service of package/ cassette type AC unit up to 4.0 Ton capcity installed installed in any position and location by cleaning outdoor and indoor unit area by blower, cleaning of condersor coil unit, Indoor cooling coil unit with suitable cleaning agents/chemicals, cleaning of filters, cheking electrical wiring, tighting wires apply proper tags, replace copper lugs, insulation tape over bare terminal and trouble shooting for any gas leakage with nitrogen and arresting leakage, recharging with required qty of refrigerant gas, replacement of copper pipe incl necessary brazing works to maintain required temperature and testing complete all as specifed and directed. Note: (i) Servicing of Acs shall be carried once in three month per AC Unit. (ii) Serive record to be submitted for claming payment and rate incl of service slip etc. (iii) Refrigerant Gas for filling, Copper pipe will be measured and paid separately.
supply only R22 gas refrigerant
supply only R-410a/R-407 gas refrigerant
supply only copper pipe 1/4 22 SWG
supply only copper pipe 1/2 22 SWG
supply and fix, testing condensate drain pump operating on single phase 230 V AC, 50 Hz suitable for cassette AC 4/3 Ton including miscelenious items required at site complete all as specifed.
supply and fix copper cooling coil suitable for R22 gas 50-90 degree, rated working pressure 150-300 PSI, suitable for cassette AC 4.0 Ton capacity complete all as specifed.
supply and fix copper condensor coil suitable for R22 gas rated working pressure 150-300 PSI, 50-90 degree suitable for cassette AC 4.0 Ton capacity complete all as specifed.
supply and fix fan blade suitable for 4Ton casstte AC outdoor unit .
supply and fix fan blade suitable for 3Ton casstte AC outdoor unit .
supply and fix Indoor unit blower motor suitable for cassette AC 4 Ton complete all as specifed.
supply and fix indoor unit fan motor suitable for cassette AC 3 Ton complete all as specifed.
supply and fix Outdoor unit motor suitable for cassette AC 4 Ton complete all as specifed.
supply and fix Outdoor unit fan motor suitable for cassette AC 3 Ton complete all as specifed.
supply and fix in repair power contactor 3 Pole 40 A capacity complete.
supply and fix copper cooling coil suitable for R22 gas rated working pressure 150-300 PSI, 50-90 degree suitable for cassette AC 3 Ton complete all as specifed.
supply and fix copper condensor coil suitable for R22 gas rated working pressure 150-300 PSI, 50-90 degree suitable for cassette AC 3.0 Ton complete all as specifed.
supply and fix sensor for 3.0/ 4.0 ton cassete type cooling coil control.
supply and fix sensor for 3.0/ 4.0 ton cassete type room temperature control
supply and fix sensor for 3.0/ 4.0 ton cassete type float and manual mode control
supply and fix three phase bakalite cable connector 10 way 40 Amps capacity.
supply and fix PCB suitable for 4.0/3.0 Ton cassete type AC suitable for as per site requirement all as directed
supply and fix replacement running capacitor 50mfd 415 Volt all as directed.
supply and fix starting capacitor 80/100mfd 415 Volt all as directed.
supply and fix starting relay suitable for 3.0 /4.0 Ton cassete type A/C all as directed.
supply and fix thermostat for 3.0/4.0 Ton Cassete type AC all as directed.
supply and fix wiring kit suitable for 3.0 / 4.0 Ton cassete type A/C all as directed
supply and fix discharge valve for 4 TR cassete type Air conditioner
supply and fix discharge valve for 3 TR cassete type Air conditioner
supply and fix Suction valve for 4 TR cassete type Air conditioner
supply and fix Suction valve for 3 TR cassete type Air conditioner
supply and fix expansion valve for 4 TR cassete type Air conditioner
supply and fix expansion valve for 3 TR cassete type Air conditioner
supply and fix driyer unit for 4 TR cassete type Air conditioner
supply and fix driyer unit for 3 TR cassete type Air conditioner
supply and fix filter unit suitable for Indoor unit cassette type 3/4Ton complete.
supply and fix and fix Pvc pipe size 25mm suitable for cassete type AC drain all as directed
supply and fix and fix NUF insulation for copper tubing suitable for cassete type AC all as directed
S&F in replacement PVC cable 4 core PVC insulated 2.5 Sqmm copper conductor 1100V all as directed.
S&F in replacement MCB three Pole 40 Amps 415Volt 3 phase all as directed.
M&L for taking down u/s Scroll compressor 4Ton capacity incl disconnect suction and discharge connections, transporting to workshop dismantle the unit by welding cut the outer frame, remove the burnt winding and rewind with super enameld copper wire incl insulation varnishing etc assemble the outer frame by welding,brazing and testing unit tranporting fixing in outdoor unit and testing the AC unit complete all as specifed and as directed.
M&L for removing old paint and apply one coat of primer & two coat of synthetic enamel paint outdoor unit as exiting colour incl writing letters/marking arrow discharge/suctiuon line ,Indoor cassette unit all as specifed
M&L for for water leak in the indoor unit of AC unit incl all accessories complete all as specifed and as directed.
M&L for submain wiring with PVC insulated, PVC unsheathed cable, single core, stranded, copper conductor cable 4 x 6.0 Sqmm size, 1100V FRLS grade, drawn into rigid non-metallic PVC conduit 25mm pipe ISI marked with 6.0 Sqmm unsheathed, stranded copper 1100V FRLS grade cable for continuous earth wire, including taking down the old wiring from control panel to Cassete AC outdoor unit main supply and fix wiring.
RK ENTERPRISES
SAMYDOSS CONSTRUCTIONS
G.L.THIRUMALAI NAIDU AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .