Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.2 L+₹2.1 L (15.9%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹16.2 L+₹3.1 L (23.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹18.9 L+₹5.8 L (44.1%)Rejected-Finance HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
30 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
Repair/Maint of HT Poles and over head lines/HT Cables with connected accessories at Sector C and D under AGE EM I of GE 865 EWS
2021_MES_464459_1
138WE/L-50/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹40,000
Yes
17 Sept 2021
2 Aug 2021
6 Sept 2021
2 Aug 2021
30 Aug 2021
16 Aug 2021
60 days
Amount
Excavation in trenches not exc 1.5m wide and not exc 1.5 m in depth and getting out for laying of cable/pole in hard/dense soil complete all as specified and as directed by Engr-in-charge.
Excavation in trenches not exc 1.5m wide, exc 1.5m depth and not exc 3.0 m in depth and getting out for pole erection in hard/dense soil complete all as specified and as directed by Engr-in-charge.
Returing, filling in (soil) including spreading, leveling, watering and well ramming in layers not exc, 25cm, complete all as specified and as directed by Engr-in-charge.
Removing excavated material n. exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed by Engr-in-charge.
M&L for crushed stone sand cushioning to underground cables, provide with the layer 8cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and as directed by Engr-in-charge.
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x 180mm x 40mm placed perpendicular to the cable complete all as specified and directed by Engr-in-charge.
Supply and fix GI pipe light grade with all connected accessories of sizes 100mm dia complete all as specified and directed by Engr-in-charge.
Cutting of existing road not exc 1.5mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC/GI pipe under road making good in all respect to match with the existing surface all as specified by Engr-in-charge.
Supply laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, earthed system of size 3 core 95 sqmm complete all as specified and directed by Engr-in-charge.
S&F in repairs cable end joint boxes 95 Sqmm, 3 core XLPE 11KV HT Cable heat shrinkable indoor/outdoor type, complete all as specified and directed by Engr-in-charge.
S&F in repairs cable straight through joint 95Sqmm, 3 core XLPE 11 KV HT cable heat shrinkable complete including necessary excavation and earth work complete all as specified and directed by Engr-in-charge.
Removing the existing unserviceable neon indication lamps from cubical panel and supply and fixing neon indicator lamps assembly complete all as specified and directed by Engr-in-charge.
M&L for replacement of voltmeter 0 to 500 volts complete all as specified and directed by Engr-in-charge. Make : DIP/AE/IMP (Digital type)
M&L for replacement of Ammeter 0 to 1000 Amps 135mm x 135mm, complete all as specified and directed by Engr-in-charge. Make : DIP/ AE/ IMP (Digital type)
M&L for filtration of transformer oil to remove moisture, sludge, carbon particles and to achive dielectric strength/rupturing capacity of oil and topping up of oil to the required level of the transformer indicator level complete all as specified and directed by Engr-in-charge. Note :- (a) Oil topping up shall be measured and paid separately. (b) Filtration shall be done at site and on line. (c) BDV test shall be carried out before the filteration and after the filteration & results recorded in triplicate duly signed by the contractor, MES rep and Engr-in-charge. (d) Dielectric strength of the oil shall not be less than 50KV after filtration & the rate quoted for the items shall be deemed to include the filteration till the desired dielectric strength is achived complete all as specified and directed by Engr-in-charge.
Supply and fill new transformer oil topping up/change complete superior quality having di-electric strength not less than 60 KV and ISI marked of approved make. Complete all as specified and directed by Engr-in-Charge. Note : (a) The transformer oil shall be ISI marked, and brought at site in sealed container only. (b) Cost of collection of samples before and after topping up/changing including testing for dielectric strength etc complete including in the rate quoted for this item.
Disconnecting the transformer any type from HT/LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts of capacity 100 to 630 KVA transformer and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the HT/LT system complete all as specified and directed by Engr-in-charge. Note :- Defective parts replaced will be measured and paid separately.
Supply and fix in repair of LT bushings with brass studs complete all as specified and directed by Engr-in-charge.
Supply and fix in repair of top cover gasket set complete all as specified and directed by Engr-in-charge
Supply and fix in repair of radiator flanged gasket 6mm thick complete all as specified and directed by Engr-in-charge.
Supply and fix in repair of oil level indicator gasket set complete all as specified and directed by Engr-in-charge.
Supply and fix in repair of HT bushing with brass studs 11 KV complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of breather assembly transport plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement/capacity of transformer complete all as specified and directed by Engr-in-charge.
Supply and fix of gang operated air break switches HT 11KV grade outdoor type, triple pole of capacity 200 Amps rating mounted on polymer based 09 insulators fitted on steel frame horizontally mechnically operated mechanism from ground level including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of drop out fuse unit expulsion type for outdoor air break gang operated switch, single pole, mounted on polymer based insulators for 11 KV working pressure, fixed to and including MS channel with nuts, bolts, washers etc, synthetic bounded fuse carrying tube complete with line taps and suitable for current carrying capacity upto 25-50 Amps and connected with suitable size of ACSR conductor as jumper between GOD and DO fuse, with 11 KV HT PVC sleeve with all fittings/accessories etc, including taking down of only fuses complete all as specified and directed by Engr-in-charge.
Supply, fixing and connecting HT 11 KV outdoor expulsion type lighting arrestors with mounting accessories complete fixed on cross arms of 2 pole structure and connected with same size of ACSR conductor as O/H HT conductor with 11 KV KT empire tape insulation with all fittings, transmission class, having discharged capacity of 65 kilo amps and suitable for working pressure of HT 11 KV complete all as specified and directed by Engr-in-charge.
S&F in repair disc insulator porcelain vitreous brown 145mm high and 255 dia ball and socket type single disc assembly for tension with tension clampstor conductors working pressure 11000 volts complete all as specified and directed by Engr-in-charge.
S&F in repair pin/post type polymer based insulator 150mm height and 150mm dia suitable for 11KV grade insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and directed by Engr-in-charge.
M&L for stay assembly complete with 30x30x6mm thick plate and 20mm dia stay rod and stay insulators all as shown in electrical plate No 1 including necessary excavation, earthwork stay bow, stay wire and PCC complete all as specified and directed by Engr-in-charge.
S&F for aluminium tubing heavy duty of size 32mm outer dia, 20mm inner dia, 06mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators connection with jumpers including removal of unserviceable one complete all as specified and directed by Engr-in-charge.
S&F for aluminium strip of size 32mm x 10mm thick with necessary clamps, bolts nuts and washers of suitable size, mounted on polymer based 11 KV insulators with jumpers including removal of unserviceable one complete all as specified and directed by Engr-in-charge.
Supply erect steel tubular swaged poles complete with cast iron base plate, final taper plug bolts, nuts and screws as specified type 410 SP-55 (11.0 meters long) complete all as specified and directed by Engr-in-charge.
M&L for cement concrete (1:4:8) type D2 in foundation filing and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc complete all as specified and directed by Engr-in-charge.
M&L for cement concrete (1:3:6) type C2 in foundation filing and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc complete all as specified and directed by Engr-in-charge.
M&L for cement concrete (1:2:4) type B1 in foundation filing and mass concrete and coping of poles incl necessary form work using 20mm graded stone aggregate etc complete all as specified and directed by Engr-in-charge.
M&L for cross arms, bracings supports clamps and back plates fabricated from structural steel section including nuts bolts, washers welding, bending cold or hot, driling holes for bolts in any shape or size as indicated or directed and inclusive of two quotes of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-charge.
M&L in replacement for aluminium conductor, steel re-inforced all as specified and directed by Engr-in-charge.
M&L in replacement for Galvanised steel wire 3.15mm or 4.00mm dia complete all as specified and directed by Engr-in-charge.
Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, checknuts and washers etc made of GI and connected eathing test points all as shown in electrical plate No 5 of SSR Part-I of 2009 and as specified or indicated and testing on completion including excavation/earth work in any typ of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4kg/sqm) funnel with grade and lugs, including galvanised iron strip 32 x 6mm with GI protection pipe of 40mm medium grade 7.5 meter long, etc complete all as specified and directed by Engr-in-charge.
M&L for HT jumper with the help of Aluminium Conductor steel re-inforcement covered with insulating materail/sleeve and including lugs at both ends as suitable at site. The length of jumper shall not be less that 2.5 meter including connection with the help of connector on the HT pole complete all as specified and directed by Engr-in-charge.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge.
M&L for painting to existing HT pole 11 mtr long including cross arms/angle etc with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 feet of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
M&L for painting to existing HT 2 pole structure 11 mtr long including cross arms/angle etc with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 feet of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
M&L for painting to existing HT 4 pole structure 11 mtr long including cross arms/angle etc with one coat of aluminium paint including preparation of surfaces with new feeder name plate with zebra type painting upto 6 feet from bottom with alternate patch of size 1 feet of white and light blue colour paint complete all as specified and directed by Engr-in-charge.
Taking down old bus bar chamber, M&L for fabricating, supplying, installing, testing & commisioning of out door type CPRI approved factory made HT 11KV feeder pillar box of size not less than 165 x 80x 117cm with top cover 5cm projected alround made with 3mm CRCA sheet weather proof, vermin proof with double door, handle with locking arrangement, powder coated with 7 tank process including PVC insulated copper bus bar 3 Nos size of 130cm x 5cm x 0.5cm & mounted on HT 11KV insulators 9 Nos (three Nos per bus bar) insulators should be mounted on MS sheet with thickness 3mm made in shape including weather proof painting. The feeder pillar box should be mounted on MS Frame made up with MS angle of size 60mm x 60mmx 6mm duly covered with MS sheet 3mm thick on all sides about 35cm from the FPB & all side removeable type including two coats of synthetic enamel paint over one coat of red oxide primer including necessary excavation earth work in any type of soil, PCC block (1:3:6) of size 120x25x60cm - 02 Nos embedded in ground etc complete including writing name of feeders of FPB with size of letters not less than 10cm all as directed by Engr-in-charge.
R B TRADERS
M/S MALIK CHAND SIRI RAM
RND ENGINEERS & CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .