| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹8.6 L Quoted ₹9.5 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹12.1 L+₹2.6 L (27.1%)Rejected-Finance | ₹12.1 L+₹2.6 L (27.1%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹14.0 L+₹4.5 L (47.6%)Rejected-Finance | ₹14.0 L+₹4.5 L (47.6%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹14.2 L+₹4.7 L (49.5%)Rejected-Finance | ₹14.2 L+₹4.7 L (49.5%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹15.0 L+₹5.5 L (58.1%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | ₹15.0 L+₹5.5 L (58.1%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
14 Sept 2021, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
REPAIR REPLACEMENT OF CEILING FANS WALL MOUNTED FAN EXHAUST FAN AND ELECTRIC GEYSER SOLAR WATER HEATER AT AF STN BARNALA UNDER GE AF HALWARA
2021_MES_468582_1
GE/HAL-40/2021-22
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS E CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹30,000
Yes
13 Nov 2021
17 Aug 2021
16 Sept 2021
17 Aug 2021
14 Sept 2021
31 Aug 2021
Amount
Taking down carefully ceiling fan / exhaust fan/wall mounted fan of any sweep with frame and wire from cealing end and checking for unserviceable parts of the fan at site or at MES Yard including re-assembling & testing for smooth functioning etc, complete all as directed by Engineer- in- Charge. Note : Replacement of unserviceble parts will be measured and paid separately under relevant items here in after)
Rewinding of ceiling fan 1200 mm sweep with super enamelled copper winding wire of existing size and guage including insulating material varnishing, drying, baking, after opening up and cleaning the rotor bearing and bushes by K oil and providing fresh grease to all bearing and bushes including re-assembling & testing for smooth functioning complete all as directed by Engineer-in Charge.
All as per srl item No 2 here in before but 1400 mm sweep ceiling fan
Rewinding of exhaust fan 225/300/380/450 mm sweep with super enamelled copper winding wire with adequate size and guage including insulation material, varnishing, drying baking, assembling materials after opening up and cleaning the rotor bearing and bushes by K oil and providing fresh grease and bushes complete including re-assembling & testing for smooth functioning etc, complete all as specified and directed by Engineer-in-Charge.
Rewinding to Wall mounted fan/air circulator fan 300/450/600 mm with super enamelled copper winding wire with adequate size and guage including insulation material, varnishing, drying baking, assembling materials after opening up and cleaning the rotor bearing and bushes by K oil and providing fresh grease and bushes complete including re-assembling & testing for smooth functioning etc, all all as specified and directed by Engineer-in-Charge. Note for Sl Item No 2 to 5 Note : (i) Fan rewinding and repair work/painting shall be done at MES yard only, no items shall be issued to take outside MOD land for repair. (ii) Spare parts shall be measured and paid serparately as supply only under respective items of this schedule but the fixing of same is included in quoted rate of this item.
Supply only ball bearing of ceiling fan 1200 mm/1400mm / exhaust fan/wall mounting fan etc as per existing size
Supply and replacement of capacitor 415 volts, 50 Hz, 2.5 MFD, ISI marked
Supply only capacitor 415 Volts, 50 Hz, 3.15 MFD, ISI marked
Supply only capacitor dry type 4 MFD, 415 Volts, 50 Hz, ISI marked
Supply only gun metal bush suitable for ceiling / exhaust fan /Wall fan any sweep, ISI marked
Supply only wall fan mounting clamp with connect nut bolt & wahsers
S&F in repairs modular fan regulator 120 watt W-2 module complete all as specifed and as directed
S&F in repairs switch modular type single pole one way 6 Amps including suitable size of module cover with frame.
S&F in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. all as specified and as directed.
S&F in repairs plug top 15 A , 3 pin suitable all as per specified and directed.
S&F in repairs plug top 5 A . 3 pin suitable all as per spefied and directed.
S&F in repairs 2.5 Sq mm power cable 3 core suitable for geyser connection all as specifed and directerd
S&F in repairs Anti suicide type down rod for ceiling fan size 45 cm length with connected nut bolt washer , all as specifed and directed.
S&F in repairs wall fan blade guard any size suitable as per req all as specified and directred.
S&F in repairs 5 A , one way piano switch flush type single pole all as specified .
Supply only armature shaft of ceiling fan any capacity , ISI marked
Supply only rubber reel with clamps, nut bolts, washers and split pin of suitable size , ISI marked
S&F in repairs bottom & upper plastic canopy complete with screws suitables for ceiling fan 1200 / 1400 mm sweep all as directed by Engineer-in Charge.
S&F in repairs new blades for wall fans & Exhaust fan.
S&F in repairs new blades of ceiling fans any type any size all as specified and as directed.
S&F in repairs new louver shutter iron body for exhaust fan any size any type all as specified and directed.
Material and labour for spray painting to fans by applying one coat of superior quality synthetic enamaled paint (white) to steel surfaces of ceiling fan 1200/1400 mm sweep fan to make it good as original including preparation & cleaning of surface and writing the MES number with black paint on fans all as specified and directed by Engineer-in Charge.
Taking down carefully water geyser/solar geyser any capacity, cable sealing end and dismantling of heating element, thermostat etc and refixing after repairs, connecting up and testing for satisfactory heating of water complete all as specified and as directed. Note :- Spare parts shall be measured and paid serparately as supply only.
Supply only 2000 watts triangle type heating element
Supply only geyser inner assembly triangle type suitable for 25/50 Ltr
Material and labour for refixing for displaced solar plate by using angle iron stand, nut bolts washer,water connections and made it to be functional all as specified and directed by Engr-in-Charge.
Supply only 1500 watts triangle type heating element
S&F in repairs solar geyser heating element with new one of 1500 watts diagonal and thread type heating element
Supply only Termostate 7''/9" suitable for 25/50 ltrs capacity water geyser with automatic thermal cut out
M&L for Gas welding work for geyser brackets/inner tanks all as specified and directed.
M&L for replacement of broken and rusted geyser bottom plate with indicator lamp green and red LED as per existing size and shape complete all as specified and directed
S&F in repairs 15mm size PVC connection 750mm long for geyser with PTMT nuts complete all as specified and directed.
S&F in repairs solar flat plate collector type with heat exchanger of 300 ltrs per day capacity and size of collector 2112 X1035 X 101mm .
S&F in repairs of hose pipe as per existing size and length with connected fittings to at both ends for solar water heater to water line connection all as specified and as directed by Engr-in-Charge.
Supply only LT tape size 25 mm Width and length of 25 mtr ISI marked.
S&F in repairs felxible 20mm bore conduit with fixing clamp complete all as specified and directed
S&F in repairs 15mm dia bore angle /stop cock of CP Brass for geyser complete all as specified and directed
S&F in repairs 15mm dia bore gun metal globe valve complete all as specifed and as directed
All as per srl item No 43 here in before but 20mm
S&F in repairs socket 15 A, 5 pin flush type all as specified and directed.
S&F in repairs 5A socket ,5 pin all as spcified and directed .
Supply only L hook fastener size 10 mm dia and 10 cm long with connected washers fising on wall for hanging of geyser all as specified and as directed.
M& L for lagging to pipes size 20mm used in internal water supply or plumbing all round with, 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and directed.
M& L for lagging to pipes size 15 mm used in internal water supply or plumbing all round with, 25mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and directed.
M&L for solar water tank insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:-(a) M&L for cleaning the solar tank surface (to be insulated ) by scrapping carefully. completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all solar water tank joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
M & L for PCC 1:2:4 type B - 1 (using 20mm grade crushed stone aggregate) as in coping including necessary from work or in any situation complete all as specified and directed
S&F in repairs mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, dia meter of neck 11 to 15 mm , each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5 cm long all as specified and as directed.
S&F in repairs rolled section as in main cross beams, hip and jack rafters: purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates.rivets, nut bolts etc complete all as specified , confirming FE 410 W (Gde-E-250) Quality B coomplete all as specified and as directed.
M&L in repairs, wiring for circuit/submain wiring alongwith warth wire with the following sizes of FRLSH in PVC insulated copper conductor, single core cable in surface/recessed as required size of 2 X 2.5 sq mm and 1 X 2.5 sq mm as earth wire all as specified and directed.
S&F in repairs 1100 volts grade heavy duty multistradned copper cable PVC insulated with an inner sheathing of PVC tape unarmoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 Core
S&F in repairs MCB 6 to 32 Amp single pole ,240 V, 10 KA, 'B' Series all as specified and as directed by Engr-in-Charge.
S&F in repairs sheet metal enclosures factory made, ( single door) for DBs, single pole and neutral, 240 Votls, 2 way fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, testing and commssioning, complete all as specified.
Supply only Exhaust fan mounting legs and clamp any size any type with connected nut, bolts, washers, including grouting work as specified and directed.
Supply and fixing of inner tank copper body of Geysers 25/50 Ltrs capacity complete all as directed by Engr-in-Charge.
S&F in repairs MCB 32 Amp SPN single pole ,240 V, 10 KA, 'B' Series all as specified and as directed by Engr-in-Charge.
M/S ASHWANI SETHI
DHALIWAL CO.
M/s SHIVA BUILDERS
M/S SANGA SINGH AND CO
SANGAM ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .