| 1 | L-1₹44.3 LAccepted-AOC 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-1 | Accepted-AOC ACCEPTED | |
| 2 | L-2₹45.2 L+₹24,799 (0.55%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L-2 | Rejected-Finance Being higher bid value | |
| 3 | L-3₹45.4 L+₹45,912 (1.02%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L-3 | Rejected-Finance Being higher bid value | |
| 4 | L-4₹46.4 L+₹1.5 L (3.30%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L-4 | Rejected-Finance Being higher bid value | |
| 5 | L-5₹46.6 L+₹1.7 L (3.77%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L-5 | Rejected-Finance Being higher bid value |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
9 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/ MAINT OF AC ALLIED WORKS AT DEFI TECH BLDG AT CH (EC), HQ BSA, IMH COMPLEX ETC UNDER GE ALIPORE KOLKATA
2023_MES_633546_1
GE/ALP(8289B) KOLKATA OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Alipore Kolkata
Class D Category c (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer Alipore
₹90,000
Yes
GE Alipore Kolkata
3 Feb 2024
19 Dec 2023
16 Jan 2024
19 Dec 2023
9 Jan 2024
2 Jan 2024
19 Dec 2023 - 26 Dec 2023
27 Dec 2023
Amount
Material and labour for replacement of 80-100 mfd Starting capacitor for water cooler of capacity 80/ 150 ltrs. (Make : Sarda/ Power or equivalent approved by Garrison Engineer
Material and labour for replacement of running capacitor 10 mfd for Water Cooler of capacity 80/ 150 ltrs. (Make : Sarada/Power or equivalent approved by Garrison Engineer
Material and labour for replacement of 15mm bore chromium plated push cock suitable for water cooler of any capacity as per existing shape and make or equivalent approved by the Garrison Engineer
Material and labour for replacement of Thermostat switch for water cooler. (Make : Indfoss or equivalent approved by the Garrison Engineer).
Material and labour for replacement of Ball brass valves 15 mm bore, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule.
Material and labour for replacement of Starting relay box type for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed
Material and labour for replacement of Capillary copper tube of size 0.36 mm for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Material and labour for replacement of Freezer door for Refrigerators of capacity upto 315 ltrs Complete all as specified and as directed.
Material and labour for replacement of Thermostat switch (Make : Indfoss/Kelvinator or equivalent approved by Garrison Engineer) for Refrigerators of capacity upto 315 ltrs
Disconnecting defective condensor coil of Refrigerators upto 315 ltrs capacity and replacing the same with new condensor coil and fixing in original position as per existing
Material and labour for replacement of Inner lights for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Disconnecting defective sealed compressor unit of Refrigerators upto 315 ltrs capacity and fixing repaired/ reconditioned sealed unit compressor in original position all as specified and as directed.
Material and labour for replacement of Door switch for Refrigerators of capacity upto 315 ltrs complete all as specified and as directed.
Material and labour for Dismantling the cover of Condensor and cooling coil, thoroughly cleaning the external surface (both side) of all the component including fins, base , discaling chemicals, water etc with the help of air blower, wire brushing and reassemble all the components plate, runner, fan blade etc in original position as and when directed for following capacity of Air Conditioners: -
Window Type Air Conditioner of capacity 1.5 TR
Window Type Air Conditioner of capacity 2.0 TR
Split type Air Conditioner of capacity 1.5 TR (1 x Indoor unit and 1 x Outdoor unit)
Split type Air Conditioner of capacity 2.0 TR (1 x Indoor unit and 1 x Outdoor unit)
Split type Air Conditioner of capacity 5.5 TR (2 x Indoor unit and 1 x Outdoor unit)
Split type Air Conditioner of capacity 7.5 TR (2 x Indoor unit and 1 x Outdoor unit)
Material and labour for repair of AC single phase 230 volt Printed Circuit Board for 1.5/ 2.0 TR capacity split type AC cooling unit of carrier/Voltas/LG/Amtex
Material and labour for repair of AC single phase 230 volt Printed Circuit Board for 5.5 TR capacity split type AC cooling unit of carrier/Voltas/LG/Amtex
Material and labour for repair of AC single phase 230 volt Printed Circuit Board for 7.5 TR capacity split type AC cooling unit of carrier/Voltas/LG/Amtex
Supply and fix as in replacement AC single phase 230 volts remote (Hand set) upto 7.5 TR capacity split type AC of carrier/Voltas/LG/Amtex complete all as specified and as directed.
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split/ Window type AC 1.5 TR capacity (Condensing unit)
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split/ Window type AC 2.0 TR capacity (Condensing unit)
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split type AC 5.5 TR capacity (Cooling unit)
Material and labour for replacement of Blower motor including replacement of bushes with same size and gauge of wire for Split type AC 7.5 TR capacity (Cooling unit)
Material and labour for replacement of Strainer for Split/ Window Type AC of any capacity.
Material and labour for replacement of 4 micro farad capacitor for blower moter of AC of any capacity. (Make: Sarda/ Power or equivalent approved by Garrison Engineer)
Material and labour for replacement of 6 micro farad capacitor for blower moter of AC. (Make : Sarda/Power or equivalent approved by Garrison Engineer)
Material and labour for replacement of 50-100 mfd Starting capacitor. (Make : Sarda/ Power or equivalent approved by Garrison Engineer)
Material and labour for replacement of 100-120 mfd Starting capacitor. (Make : Sarda/Power or equivalent approved by Garrison Engineer)
Material and labour for replacement of Thermostat switch for 1.5 TR capacity Window Type AC. (Make: Indfoss or equivalent approved by Garrison Engineer).
Material and labour for replacement of Sensor for 1.5/ 2.0 TR capacity Split type AC. (Make: Indfoss or equivalent approved by Garrison Engineer)
Material and labour for replacement of Sensor for 5.5 TR capacity Split type AC. (Make: Indfoss or equivalent approved by Garrison Engineer).
Material and labour for replacement of Sensor for 7.5 TR capacity Split type AC. (Make: Indfoss or equivalent approved by Garrison Engineer).
Material and labour for replacement of Fan Blade for 1.5/2 TR capacity Window type AC.
SMaterial and labour for replacement of Fan Blade for 5.5 TR capacity Split Type AC
Material and labour for replacement of Fan Blade for 7.5 TR capacity Split Type AC
Material and labour for replacement of Over load protector for Window/ Split Type AC of capacity 1.5/2.0 TR, make : Shriram/ Arbind or equivalent approved by Garrison Engineer
Material and labour for replacement of Over load protector for Window/ Split Type AC of capacity 5.5/7.5 TR, make : Shriram/ Arbind or equivalent approved by Garrison Engineer
Material and labour for replacement of Capillary copper tube of size 0.064 inch dia
Material and labour for replacement of Runner for 1.5/ 2.0 TR Window Type AC.
Material and labour for replacement of Runner for Indoor unit of 1.5/ 2.0 TR Split Type AC.
Material and labour for replacement of Runner for Indoor unit of 5.5 TR Split Type AC.
Material and labour for replacement of Runner for Indoor unit of 7.5 TR Split Type AC.
Material and labour for replacement of Starting Relay for window/ Split type AC of capacity 1.5/ 2.0 TR. (Make: Shriram/ Arbind or equivalent approved by Garrison Engineer)
Material and labour for replacement of Starting Relay for window/ Split type AC of capacity 5.5 TR. (Make: Shriram/ Arbind or equivalent approved by Garrison Engineer)
Material and labour for replacement of Starting Relay for window/ Split type AC of capacity 7.5 TR. (Make: Shriram/ Arbind or equivalent approved by Garrison Engineer)
Material and labour for replacement of Front cabinet for 1.5 TR Window Type AC
Material and labour for replacement of Air filter for 1.5/2.0 TR Window Type AC
Material and labour for replacement of Base tray for Window Type AC of 1.5/2.0 TR capacity
Material and labour for replacement of 16 Amps, 3 pin, 240 Volts Plug top. (Make : Anchor or equivalent specified in PS)
Supply and fixing in repair MCB SPN, 32 Amps, 240 Volts , breaking capacity 10KA complete all as directed. Make-L&T/Legrand/Havells.
Supply and fixing in repair MCB TPN, 40 to 63 Amps, 440 Volts , breaking capacity 10KA complete all as directed. MMake-L&T/Legrand/Havells.
Disconnecting defective sealed receprocating type compressor unit of 1.5/2.0 TR Split/ Window/ Package type AC from the system and fixing repaired/ reconditioned sealed unit compressor in original position all as specified and as directed
Disconnecting defective sealed receprocating type compressor unit of 5.5 TR Split/ Window/ Package type AC from the system and fixing repaired/ reconditioned sealed unit compressor in original position all as specified and as directed
Disconnecting defective sealed receprocating type compressor unit of 7.5 TR Split/ Window/ Package type AC from the system and fixing repaired/ reconditioned sealed unit compressor in original position all as specified and as directed
Disconnecting defective sealed rotary type compressor unit of 1.5/2.0 TR Split/ Window/ Package type AC from the system and fixing repaired/ reconditioned sealed unit compressor in original position all as specified and as directed
Supply and laying out of copper pipe (hard) 5/8" dia with PUF insulation CFC free etc as required at site complete all as specified and as directed by the Engr-in-Charge.
Supply and lay out of copper pipe (hard) 3/8" dia with PUF insulation CFC free etc as required at site complete all as specified and as directed by the Engr-in-Charge.
Cleaning the cooling coil and condensor with the help of compressed Nitrogen inner side of the copper tube for flushing out all sludge and oil deposited in the copper tube and materials and labour for charging of refrigerant R-22 as required including replacement of strainer and finding out the leakage, brushing the same, testing for following capacity of AC complete all as specified and as directed by the Engr-in-Charge:- (a) Split/Window type Air conditioner 1.5/ 2.0 TR capacity
All as per item No 58 above but capacity 5.5 TR
All as per item No 58 above but capacity 7.5 TR
Supply and fixing MCB protected Power Unit with 16 - 25 Amp MCB, Motor Starter, Socket and Plug Top with indicating light. (Make: North West/ Havells/L&T)
Material and labour for charging of Refrigerant R-22/32 / of suitable type (CFC based / non CFC based) in Split/ Window AC, Water Cooler and Refrigerator
All as per item No 62 above but Refrigerant R-134a/410
Material and labour for replacment of Drier of 5.5 TR Ductable AC Copper wire superior quawality with all necessary arangment complete all as specified and as directed by the Engr-in-Charge.
Material and labour for replacment of Drier of 7.5 TR Ductable AC Copper wire superior quawality with all necessary arangment complete all as specified and as directed by the Engr-in-Charge.
Dismantling and taking down from existing position window type AC 1.5 / 2 Ton capacity and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position with brick work, plastering etc and new position etc all as directed by Engr-in-Charge.
Dismantalimg and Refixing In anothed place with good making surface with servicing of Indoor Outdoor unit for 1.5/2 TR Split AC with all necessary arangment complete all as specified and as directed by the Engr-in-Charge.
Material and labour for painting with one coat of red oxide primer and two coats of black japan paint including preparation old/ new surface of steel of any description all as specifierd and as directed.
Supply and Fixing New Indoor unit with remote of 1.5 TR Capcity of existing. (Make of Voltas/ Carrier/ LG/ Blue star complete all as specified and directed).
Supply and Fixing New Indoor unit with remote of 2 TR Capcity of existing make of Voltas/ Carrier/ LG/ Blue star complete all as specified and directed).
Supply and fix as in repair for PVC insulated flexible copper conductor cable (FRLS) 2.5 Sqmm 4 core , 1100 Volts grade conforming to IS 694.
Supply and fix as in repair for PVC insulated flexible copper conductor cable (FRLS) 2.5 Sqmm 3 core , 1100 Volts grade conforming to IS 694.
Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. alongwith all accessories, clamp, bend, tee etc.
Providing maintenance services for summer appliances on daily basis by engaging Refrigerator Mechanic-1 No(Skilled) and Helper-01 No (Semi Skilled) for necessary servicing of Air conditioners, water cooler & Refrigerator and carryout necessary repair, filling of refrigerent gas, shifting of AC etc. all as specified and as directed by Engineer-in-charge. Note: (i) The above personnel shall have to be present at the MES service centre at HQ BSA to carryout the work in the same complex and gokhle road complex also. (ii) Any spare parts/Refrigerant required to be used by the above present shall be measured and paid seperately under "supply only of items" (iii) Daily Job card shall be issued to the above presonnel by thye concerned JE E/M as per requirment at site (iv) Necessary tools shall be provided by cotractor
Supply of AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit of carrier/Voltas/LG/Amtex complete all as specified and as directed.
supply of Strainer for Split AC of any capacity.
Supply of 4 mfd capacitor for blower moter of AC of any capacity. Make: Sarda/ Universal/Tibcon motor
Supply of 6 mfd capacitor for blower moter of AC of any capacity. Make: Sarda/ Universal/Tibcon motor
Supply of 36 mfd running capacitor of any capacity. Make: Sarda/ Universal/Tibcon motor
Supply of 40 mfd running capacitor of any capacity. Make: Sarda/ Universal/Tibcon motor
Supply of 50 mfd running capacitor of any capacity. Make : Make: Sarda/ Universal/Tibcon motor
Supply of 100-120 mfd Starting capacitor of any capacity. Make: Sarda/ Universal/Tibcon motor
Supply of Sensor for 1.5/ 2.0 TR capacity Split type AC complete all as specified and as directed.
Supply of Fan Blade for 1.5/ 2 TR capacity Split Type AC for condenser unit.
Supply of Over load protector for Split Type AC of capacity 2 TR complete all as specified and as directed.
Supply of Over load protector for Split Type AC of capacity 1.5 TR complete all as specified and as directed.
Supply of Capillary copper tube of size 0.064 inch dia complete all as specified and as directed.
Supply of Runner for Indoor unit of 1.5/ 2.0 TR Split Type AC complete all as specified and as directed.
Supply of Starting Relay for / Split type AC of capacity 1.5/ 2.0 TR complete all as specified and as directed. Make- Ranutrol/Amazor/Elkay/Real life/Uxcell
Supply of copper pipe (hard) 5/8" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) all as specified and as directed by the Engr-in-Charge.
Supply of copper pipe (hard) 3/8" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) all as specified and as directed by the Engr-in-Charge.
Supply of copper pipe (hard) 1/4" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) all as specified and as directed by the Engr-in-Charge.
SSupply of copper pipe (hard) 1/2" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) all as specified and as directed by the Engr-in-Charge.
Supply of Refrigerant of suitable type (CFC based/Non CFC Based) in Split/ AC, Water Cooler and Refrigerator complete all as specified and as directed.
Supply of PVC flexible hose pipe 20 mm for water drain out line dually clamped on wall as driected by engg-in-charge.
Supply Only modular type 32 A Motor starters (for AC) white clour, Make crabtree/Havells/Legrand/North west/Anchor (ROMA)
Material and labour for replacement of Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule of size 15 mm complete all as specified and directed. Make - Prayag/Polytuf/Stec
Disconnecting defective sealed compressor unit of Water Cooler 80/ 150 ltrs capacity from the water cooler and fixing of new compressor of same specification in original position all as specified and as directed. Make- Kirloskar/SP/RAM/Tecumsh
Material and labour of Door gasket for 150 ltrs capacity Water Cooler
Material and labour of Door gasket for 80 ltrs capacity Water Cooler
Material and labour for Starting Relay suitable for water cooler 80/ 150 ltrs capacityMake- Ranutrol/Elkay/Real Life/Uxcell
Material and labour for replacement of Overload protector suitable for Water Cooler of capacity 150 ltrs
Material and labour for replacement as in repair of Overload protector suitable for Water Cooler of capacity 80 ltrs
Material and labour for replacement of Starting relay box type for Refrigerators/deep freezer of capacity upto 400 ltrs. Make- Ranutrol/Elkay/Whirlpool/Uxcell
Material and labour for replacement of copper Capillary tube of size 0.36 mm for Refrigerators/deep freezer of capacity upto 400 ltrs.
Material and labour for replacement of Cooling coil for refrigerators/deep freezer of capacity upto 315 ltrs.
Material and labour for Freezer door for Refrigerators/deep freezer of capacity upto 400 ltrs
Material and labour for replacement of Thermostat switch for Refrigerators/deep freezer of capacity upto 400 ltrs. Make- Ranutrol/Indfoss/Kelvinator
Material and labour for Chill tray forRefrigerators/deep freezer of capacity upto 315 ltrs.
Disconnecting defective condenser coil of Refrigerators/deep freezer upto 400 ltrs capacity and replacing the same with new condenser coil and fixing in original position as per existing specification and size complete all as specified and directed.
Material and labour for Inner lights filament type/LED for Refrigerators/deep freezer of capacity upto 400 ltrs
Disconnecting defective sealed compressor unit of Refrigerators/deep freezerupto 400 ltrs capacity and fixing new hermitcially sealed compressor unit of same specificationas
Material and labour for Door switch for Refrigerators/deep freezer of capacity upto 400 ltrs
Material and labour for replacement of 5/15 Amps 3 pin 230 Volts Plug Top Make : Anchor/gold medal/havells/standard
Supply and fixing of AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit of carrier/Voltas/LG/Amtex complete all as specified and as directed.
M&L for replacement of AC single phase 230 volts remote control unit (Hand set) for 1.5/ 2.0 TR capacity for split type AC of carrier/Voltas/LG/Amtex complete all as specified and as directed by the Engr-in-Charge.
Re-winding Blower motor, including replacement of bushes, with same size and gauge of super enamelled copper wire for Split type AC 1.5 TR capacity (Condensing unit)
Re-winding Blower motor including replacement of bushes with same size and gauge of wire for Split type AC 2.0 TR capacity (Condensing unit) complete all as specified and as directed.
Re-winding Blower motor including replacement of bushes with same size and gauge of super enamelled copper wire for Split type AC 1.5/ 2.0 TR capacity (Cooling unit) complete all as specified and as directed.
Material and labour for replacment of 36 mfd running capacitor of any capacity. Make: Sarda/ Universal/Tibcon motor
Material and labour for replacment of 40 mfd running capacitor of any capacity. Make: Sarda/ Universal/Tibcon motor
Material and labour for replacment of 50 mfd running capacitor of any capacity. Make : Make: Sarda/ Universal/Tibcon motor
Material and labour in repair of 1/5 HP Blower motor complete all as specified and as directed. Make : American universal/ Air cool
Supply and fixing of rotary type compressor for Split type AC of capacity 1.5 TR complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing of rotary type compressor for Split type AC of capacity 2.0 TR complete all as specified and as directed by the Engr-in-Charge.
Supply and laying of copper pipe (hard) 1/4" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) all as specified and as directed by the Engr-in-Charge.
Supply and lay of copper pipe (hard) 1/2" dia with PUF insulation as per required length at site complete with flaring nuts of suitable size (brass) all as specified and as directed by the Engr-in-Charge.
Material and labour for taking out and dismantling the existing rusted unserviceable condenser coils from the existing system of 1.5/ 2.0 TR capacity of type split type AC unit after decanning refrigerent gas from the system to empty cylinder, disconnecting all electrical connection, flair nuts, valves and shut down all preventive valves properly, supply and replacing with new condenser coils as per existing size and specification including necessary fixing arrangement and connect all electrical and safety protection devices to the existing system and flushing the whole system by nitrogen, leak testing by 200 PSI nitrogen pressure holding of 48 hours, charging of decanning refrigerent to the system and charging of additional refrigerent as required, commisioning and testing complete all as specified and as directed by the Engr-in-Charge.
Material and Labour for disconnecting defective indoor unit of split AC capacity 2 TR and replacing the same with new indoor unit in position fixing in original position as per existing and compaitable to existing make complete all as specified and as directed.
Material and Labour for disconnecting defective outdoor unit of split AC capacity 2 TR and replacing the same with new outdoor unit including compressor in position fixing in original position as per existing and compaitable to existing make complete all as specified and as directed.
Material and Labour for disconnecting defective indoor unit of split AC capacity 1.5 TR and replacing the same with new indoor unit in position fixing in original position as per existing and compaitable to existing make complete all as specified and as directed.
Material and Labour for disconnecting defective outdoor unit of split AC capacity 1.5 TR and replacing the same with new outdoor unit including compressor in position fixing in original position as per existing and compaitable to existing make complete all as specified and as directed.
S & Fixing PVC flexible hose pipe 20 mm for water drain out line dually clamped on wall as driected by engg-in-charge.
RADHA ENTERPRISE
M/S J S ENTERPRISES
SUDHA ENTERPRISES
KWALITY CONSTRUCTION
INDIA ELECTRICAL EQUIPMENTS
M/s UNIVERSAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .