| Sl No | Description | Qty | Unit | Raj Engineering Co. L1 |
|---|---|---|---|---|
| 1.01 | Renovation of LT Panel with allied works at Sarita Vihar SPS with following works:-
Dismantling of old Components from existing Panel, removing of all cable connection after taking shut down Dismantling of old Power contactor,MCCB & other accessories i.e. amp/volt meter ,indicating light from existing Panel ,removing of all cable connection ,damaged wiring | 1 | Job | 13,500 ₹15,930 Lowest |
| 1.02 | Power contactor 220V TP 550Amp. Make: L&T/Any DJB approved make | 2 | Nos. | 1,34,000 ₹1,58,120 Lowest |
| 1.03 | Under voltage Release Make L&T/Any DJB approved make | 1 | No. | 2,900 ₹3,422 Lowest |
| 1.04 | MCCB 3 pole 50ka 630Amp. Make: L&T/Any DJB approved make | 3 | No. | 57,900 ₹68,322 Lowest |
| 1.05 | MCCB 3 pole 50ka 100Amp. Make: L&T/Any DJB approved make | 5 | Nos. | 26,500 ₹31,270 Lowest |
| 1.06 | MCCB 3 pole 50ka 63Amp. Make: L&T/Any DJB approved make | 3 | Nos. | 15,900 ₹18,762 Lowest |
| 1.07 | Providing /fixing and making connection of bus bar 630 Amp. to connect MCCB size suitable for 630 Amp. Current carrying capacity. including links, bends aluminum bus bar will be of electrolytic grade conductivity or as per relevant IS having sufficient cross section area insulated with heat shrinkable PVC sleeve in phase color identification. The bus bar support insulator shall be of class F insulation. All hard ware for connection/joints shall be in high tensile. | 3 | Jobs | 12,900 ₹15,222 Lowest |
| 1.08 | Providing /fixing and making connection of bus bar up to 100 Amp. to connect MCCB size suitable for 100 Amp. Current carrying capacity. including links, bends aluminum bus bar will be of electrolytic grade conductivity or as per relevant IS having sufficient cross section area insulated with heat shrinkable PVC sleeve in phase color identification. The bus bar support insulator shall be of class F insulation. All hard ware for connection/joints shall be in high tensile. | 3 | Jobs | 9,900 ₹11,682 Lowest |
| 1.09 | Making by P/F of incoming & out going cable termination link for 400Amp. MCCB duly sleeved with heat shrinkable sleeve with hard wares | 3 | JObs | 7,500 ₹8,850 Lowest |
| 1.10 | Cleaning through CRC & insulation on bus bar by PVC tapping on horizontal & vertical bus bar | 1 | Job | 6,500 ₹7,670 Lowest |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
4 Jul 2025, 11:00 amClosed
EE SDW V
Ring Road Andrews Ganj New Delhi 110049
Renovation of LT Panel with allied works at Sarita Vihar SPS.
2025_DJB_274591_12
N.I.T. No. 03 2025 26
Open Tender
Miscellaneous Works
Works
15 days
Ring Road Andrews Ganj New Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹14,000
7 Aug 2025
28 Jun 2025
4 Jul 2025
28 Jun 2025
4 Jul 2025
28 Jun 2025
Renovation of LT Panel with allied works at Sarita Vihar SPS with following works:- Dismantling of old Components from existing Panel, removing of all cable connection after taking shut down Dismantling of old Power contactor,MCCB & other accessories i.e. amp/volt meter ,indicating light from existing Panel ,removing of all cable connection ,damaged wiring
Power contactor 220V TP 550Amp. Make: L&T/Any DJB approved make
Under voltage Release Make L&T/Any DJB approved make
MCCB 3 pole 50ka 630Amp. Make: L&T/Any DJB approved make
MCCB 3 pole 50ka 100Amp. Make: L&T/Any DJB approved make
MCCB 3 pole 50ka 63Amp. Make: L&T/Any DJB approved make
Providing /fixing and making connection of bus bar 630 Amp. to connect MCCB size suitable for 630 Amp. Current carrying capacity. including links, bends aluminum bus bar will be of electrolytic grade conductivity or as per relevant IS having sufficient cross section area insulated with heat shrinkable PVC sleeve in phase color identification. The bus bar support insulator shall be of class F insulation. All hard ware for connection/joints shall be in high tensile.
Providing /fixing and making connection of bus bar up to 100 Amp. to connect MCCB size suitable for 100 Amp. Current carrying capacity. including links, bends aluminum bus bar will be of electrolytic grade conductivity or as per relevant IS having sufficient cross section area insulated with heat shrinkable PVC sleeve in phase color identification. The bus bar support insulator shall be of class F insulation. All hard ware for connection/joints shall be in high tensile.
Making by P/F of incoming & out going cable termination link for 400Amp. MCCB duly sleeved with heat shrinkable sleeve with hard wares
Cleaning through CRC & insulation on bus bar by PVC tapping on horizontal & vertical bus bar
Replacement of Amp .meter digital with adaptor plate complete wiring with copper control wire in LT panel
Replacement of volt meter digital with adaptor plate complete wiring with copper control wire in LT panel
Auxiliary contactor block 2No+2NC
Replacement of indicating lights RED in LT panel & HT Panel 220VAC with element block contact & making wiring in copper wire, lugs etc.
Replacement of indicating lights GREEN in LT panel & HT Panel220VAC with element block contact & making wiring in copper wire, lugs etc
Replacement of indicating lights YELLOW in LT panel & HT Panel 220VAC with element block contact & making wiring in copper wire, lugs etc
Replacement of indicating lights BLUE in LT panel & HT Panel 220VAC with element block contact & making wiring in copper wire, lugs etc
Servicing/overhauling & checking of control wiring of ACB incomer & bus coupler & other components, cleaning/greasing of contact parts, decarbonizing the contact. & re-fitting of the components at their respective space.
Fixing of the 100 Amp & 63 Amp.. MCCB in the existing L T Panel Board including Modification in base plate for fixing of MCCB, connection with bus bar links incoming & out going.
Fixing of the 550 Amp. Power contactor in the existing L T Panel Board including Modification in base plate for fixing of contactor, connection with bus bar links incoming & out going.
Fixing of the 630 Amp. MCCB in the existing L T Panel Board including Modification in base plate for fixing of MCCB, connection with bus bar links incoming & out going.
Loading, Unloading, Cartage and Transportation charges for the above Panel up to the site including charges of heavy labour etc.
Testing & commissioning of MCCB & other allied accessories ,as per required parameters with relevant IS .testing of the panel prior to switching on as follow i) Continuity and earth testing ii) Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth. iii) checking for all tightness of nut and bolts iv) Alignments of doors etc. v) Interlocking tests. vi) All function tests Testing on NO LOAD and then ON LOAD as per the satisfaction of engineer in charge
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .