| 3 | L3₹40.0 L+₹1.2 L (3.21%)Rejected-Finance C O PULOKE NEOGI SURYA SEN PALLY PO KADAMTALA 734011 DIST DARJEELING WB | KADAMTALA | DARJEELING | WEST BENGAL | 734011 | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹40.3 L+₹1.5 L (3.93%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹40.6 L+₹1.8 L (4.62%)Rejected-Finance 16 APC SARANI WARD NO 30 DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 WB | SILIGURI | DARJEELING | WEST BENGAL | 734004 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
19 Oct 2021, 6:00 pmClosed
GE (AF) BAGDOGRA
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
IMPROVEMENT OF AIRMEN MESS, SNCOS MESS, DSC MESS AND BILLETS ,PROVN OF WASHROOM BESIDE STATION BRIEFING HALL,PROVN OF 62.5 KVA DG SET FOR STN SECURITY, PROVN OF 02 EARTH PIT IN OPS ROOM BUILDING AT 273SU AT AF STN UNDER GE (AF) BAGDOGRA
2021_MES_478143_1
8401/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BAGDOGRA
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) BAGDOGRA
₹73,000
Yes
13 Nov 2021
28 Sept 2021
21 Oct 2021
28 Sept 2021
19 Oct 2021
12 Oct 2021
Amount
Demolition of brick work built in cement morter or cement lime mortar incl all quoins, arches, pillar etc complete all as specified and directed.
M&L for brick work with sub class 'B' brick, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n.exe. 15 cm thickness (below or above ground level).
M&L for 100mm thick PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in sub base.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection.
M&L for maching cut kota stone slab 20 to 25mm thick as in flooring over screed bed 15mm thick in CM 1:6 laid & jointed with cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified.
M&L for maching cut kota stone slab 20 to 25mm thick as in riser of steps, skirting , dado and pillar laid over cement 10mm thick cement rendering in CM 1:4 and jointed with ditto cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified.
Taking down cement plaster of any description of brick work or stone masonry walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 10mm thick rendering on brick work or concrete surfaces in cement mortar 1:6 finish even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying three coats of white wash complete all as specified and directed.
Demolition of stone slab and tiles of any description laid, bedded and pointed in any mortar or thickness in floor apron etc.
M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types incl 15mm thick screed bed in CM 1:6.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out soft /loose soil.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass-concrete.
M&L for brick work with sub class 'B' brick, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of external surfaces walls of buildings and preparation of newly plastered external surface & applying two coat of cement base paint over one coat of primer on wall/roof complete all as specified.
S&F for TMT bars 10mm dia and over, cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed ) not less than 0.9mm dia or securing with clip.
All as per items No 19 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in slab supported on wall and columns in floors, roofs, landings balconies, canopies, deck slabs.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates ) as in slab supported on wall, roofs, landings over 1.5m span
S&F for 25mm GI tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F for 20mm GI tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F for 15mm GI tubes, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors.
S&F for PVC water storage tank cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 1000 ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including removing from site complete all as specified and directed.
S&F for 25mm dia gun metal gate valve with iron wheel haeded screwed both ends to iron pipe and fixed complete all as specified and directed.
S&F for 20mm dia gun metal gate valve with iron wheel headed screwed both ends to iron pipe and fixed complete all as specified and directed.
Dismantling floor, hearth or wall tilling, stone slab etc including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed.
M&L for granite (of any type) tiles 20mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shad of granite stone including cutting and polishing types incl 15mm thick screed bed in CM 1:6.
M&L for glazed ceramic coloured tiles 200x300x7mm in vertical surfaces over and including 10mm thick rendering in cement mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B1 (20 graded aggregate ) as in sub base of floors etc complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile 0.16 sqm over and including 15mm thick screed bed in cement mortar (1:6) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
S&F in repair white vitreous china squatting pan "Orissa pattern" long pan of size 580x440 mm with and including 100mm bore 'P' or 'S' trap and integral foot rest and PCC 1:5:10 type E-2 all as specified.
S&F in repair PVC flushing cistern low level 10 ltr capacity of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as specified and directed.
S&F in repair vitreous china WHB white with flat back of size 550x400mm with bracket including CP waste coupling and 32 mm PVC waste pipe complete all as specified and directed.
S&F in repair white vitreous china wash down water closet pan (Pedestal Pattern) incl 100mm dia 'P' or 'S' trap but excluding flucing cistern and flush pipe.
S&F in repairs plastic water closet seat, closed pattern with flat bottom with cover and mild mild steel cromium plated or aluminised hinging device.
S&F in repair PVC jet fixed to water closet pedestal pattern complete all as specified and directed.
S&F in repairs vitreous china bowl urinal flat back, size of 465x355x265 mm white (minimum), with grating and union for discharge pipe, complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S&F in repair 15mm bore pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm - 110gms)
S&F in repairs PVC connection suitable for 15mm bore fitting 600 mm long brass nuts and adaptors complete.
S&F in repair 15mm bore bib tap standard or PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm 90gms).
S&F in repair swivel shower of PTMT any colour for fixing with 15mm pipe (Minimum weight 40gms)
S&F in repair shower arm 15mm size 195mm long with bend of 45 degree with flange of PTMT any colour (Minimum weight 40 gms)
S&F in repair angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm -90gms)
S&F for 15mm bore stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm - 90gms / 20mm - 112gms)
S&F for 32mm dia flush pipe of polyethylene of low or high density for low level cistern.
Taking down chowkhat or frame of any description n. exc 1.5 Sqm each (with out taking of shutters from the frame) and removing from site complete all as specified.
S&F for solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube.
S&F for factory made solid PVC moulded door shutters 28 to 30 mm thick with particle board core (stile), with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plan colour PVC sheet on back face complete all as specified.
S&F for MS butt hinges medium weight 100mm size fixed with MS screws.
S&F for aluminium anodised barrel tower bolt extruded section 200mm long and fixed with MS screws.
S&F for 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with MS screws.
S&F for pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete size of frame 105mm x 60mm.
S&F for 35mm thick plain framed, panelled shutter (two panel ) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part -I) kiln seasoned and chemically pressure treated.
S&F for 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and staples.
Preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer.
Dismantling timber scantling (unframed) 40 sqcm and over in section in any position.
S&F for roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc confirming to Fe-290 (Gde E-265).
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings confirming to Fe-290 (Gde E-165).
M&L for two coats of synthetic enamel painting over a coat of zinc crome on steel surfaces over 10cm width or girth incl preparation of new surface.
Dismantling AC corrugated or semi corrugated sheets including ridges as in roof and segregating serviceable sheet for reuse and removing unserviceable from site complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated or semi corrugated steel sheet 0.50 mm thick (BMT) of any colour having tensile strength of 550Mps as in roof covering /cladding to wall fixed with self tapping screws all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (BMT) of any colour having tensile strength of 550 Mps as in roof ridge, covering /cladding to wall fixed with self tapping screws or "J" hook all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs etc any thickness including cover fillets complete all as specified and directed.
S&F for powder coated galvanised iron snap grid frame work of size 600 x 600mm for false ceiling comprising of main runner 'T' section of size 38mm x 24mm x 0.40mm thickness, cross 'T' of size 29mm x 24mm x 0.3mm thickness and wall angle of size 24mm x 24mm x 0.43mm thick suspended with 4mm dia GI wire from purlin @ 1.20m c/c and fixed with 4mm thick designer ceiling boards complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base etc. complete all as specified and as directed.
M&L for pre polished chemically treated chequered cement concrete coloured tiles 25mm thick, set jointed and pointed with grey cement and pigments in neat cement slurry laid over 20mm thick screed bed in CM (1:6) in floors, confirming to IS 13801.
M&L for vitrified ceramic dark shade tiles 10mm thick (Square /Rectangular) polished area of each tiles n exc 0.36 sqm as in floor laid over 15mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
Returning and filling in with soil obtained from excavation in laying n exc 25cm thick including watering ramming etc.
Moorum filling in floors or pavings laid in layers n.exc 15 cm thick, pread and levelled and rammed including watering.
Spreading, levelling in layers n. exc 25cm thick and well ramming including watering as required all as specified.
M&L for 20mm thick damp proof courses to horizintal or vertical surface including necessary formwork in cement mortar 1:2.
M&L for 100mm thick plain cement concrete Type D-2,1:4:8 (using 40mm graded aggregate) as in sub base of floor complete all as specified.
M&L for 40mm thick Plain cement concrete Type B-1,1:2:4 (using 40mm graded aggregate) as in floor finished even and smooth without using extra cement.
M&L for Hard core of broken stone boulders gauge n exc 63mm deposited,spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface.
S&F for Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frame at site as per specification & drawing.
S&F for Aluminium anodized barrel tower bolts of extruded section and fixed 150mm
S&F for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt,welded tubes conforming to IS 1161-1979 grade ST-240.
Supply and fixed for 15mm bore Bib taps chromium plated (Long Body), with wall flange, screwed down, screwed for GI pipe or brass ferrule complete all as specified and as directed .
Supply and fixed for 15mm bore Pillar taps, long neck cast copper alloy with capstan head, chromium plated, screwed down, high pressure with long screwed shanks, fly-nuts, with screwed for 15mm bore GI pipe complete all as specified and as directed.
Supply and fixed for 15 mm bore Angular Stop cocks, chromium plated (concealed type), screwed down, high pressure, screwed both ends for 15mm bore GI pipe or for union complete all as specified and as directed.
Supply and fixed for Vitreous china wash hand basin, flat back, white of size 630x450mm including cutting for and pinning in ends of brackets with and including brackets and 32mm bore 1.50m long DPE waste pipe complete all as specified and as directed.
Supply and fixed in repairs PTMT Grating doom 125 mm dia with waste hole of having minimum weight 40gms complete all as specified and as directed.
S&F PVC connection 15 mm dia and 450 mm long with synthetic metal nut complete all as specified .
Cutting into existing manholes for connecting new drains, making good to pipe 150mm dia & rendering, cutting out existing benching channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished & reforming benching as required.
M&L for preparation of new plastered surfaces.of any description on walls applying two coat of white wash on wall all as specified and directed.
150mm dia SGSW pipes excavation in ordinary soil at average depth 1.5M inclusive of Man holes RCC precast man holes cover having 6mm plate embedded all round. Fibre reinforced cover with angle iron/pipes laid on PCC bedding incl packing under and haunching against sides etc grade 'A' laid in trenches and jointed with cement as specified.
M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaries/ fan at other end complete as per site requirement and all as specified & directed by Engr-in-Charge for the following:- (a) One light point or one fan point controlled by one switch with cables 1.5 sqmm size . Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
All as per ser item No. 90 above but for One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No. 90 above but for One 5 Amp 5 pin socket outlet point on independent board.
All as per ser item No. 90 above but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes.
Supply and fixing in replacement switch piano flush button 5 Amp single pole one way 230 volts white finish all as specified & directed.
Supply and fixing of socket outlet flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
Supply and fixing of switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/ 2pin 5 Amp plug top white/ivory finish.
Supply and fixing of switch socket combination multipurpose flush type 2 in 1 type (3 and 5 pin) 5/15 Amps, 230V, AC.
Supply and fixing ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish.
Supply & fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required all as specified and directed of approved make.
Supply & hanging of ceiling fan 1200 mm Sweep, single phase, BEE star rating/ energy efficient, white/ brown/ Ivory colour, 240 Volt, 50 Hz complete with making electric connection to ceiling rose with using three core copper cable of 1.5 Sqmm all as per site requirement and as directed. Note :- Fixing/hanging arrangement for ceiling fan such as making of hook with 10mm MS bar, nut bolt washers etc to be made within the quoted rate.
Supply and fixing surface and wall mounted LED batten luminaries 20 watt - 4Ft White with comprises of extruded channel in thermally conductive material, High translucent serrated milky white diffuser is used to get glare free and smooth light distribution and having efficacy not less than 100 lumen/watt all as specified and directed.
S & F of lamp holder Angle/Batten Type bakelite insulated body with back plate suitable for batten fitting with LED Lamp 9/10Wats all as directed. Make : Cona/Havells/SSK
Supply and Fixing of MCB SP 6 - 32 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series all as specified & directed.
Supply and Fixing of MCB SPN/DP upto 32 Amps, 230 Volts, 50 Hz with 10 KA ,'C' series all as specified & directed.
Supply and fixing distribution board sheet metal enlosure double door shutter type factory made fixed flush on wall surface suitable for mounting MCB's & isolators, 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 6 ways all as specified & directed.
Supply and fixing of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits not less than 25mm, including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main. (ii) PVC conduit and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
Supply and fixing surface and wall mounted LED batten 10 watt - 2Ft White with Aluminium housing & integrated electronic driver and all as specified and directed.
Supply and fixing of Exhaust fan metallic body, 300 mm sweep,1400 RPM, 230Volts, AC, Single phase with louver shutter including making holes for fixing of exhaust fan and making surface complete with all fixing accessories all as per site requirement and as directed.
Supply and fixing of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 4 Sqmm drawn through in and including rigid PVC heavy duty PVC casing caping or PVC conduit upto 25mm on wall surface/ recessed as required at site including 4 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates.
Supply and fixing distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways all as specified & directed.
Supply install testing and commissioning auto mains failure, silent type Diesel Engine Generating set 415 Volts 62.5 KVA,83 BHP , 3-Phase 0.8 power factor 50 Hz, 1500 RPM self exicite self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at Siliguri(WB) and conforming to condition and shall also be suitable for the temperature below 10 degree celsius under IS-10002, 13364 Part-II 1992, BS 5514/2613/5000 with following:-
(i) The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS standards design. (ii) Alternator-Standard design alternator rated at 62.5 KVA at 0.8(lag) power factor AC, 3 Phase, 4-Wire 415 Volts 50 Hz, 1500 RPM. Self excited self regulated screen protected drip proof brushless design with willing in pole faces, insulting class 'H' and voltage regulation of +1% at rated voltage from no load to full load. The alternator shall be conforming to BS-2613/5000,IS-13364 and shall be in position to generate supply with frequency regulation with +1% tolerance. The alternator will be suitable for tropical climate and shall generally conforming to BS- 2613/5000/IS-4722 (a) Insulation class-'H' (b) Temperature rise Class-'H' (c ) Excitation : Self Excited (d) Regulation performance: The voltage is kept constant with +1%m manual voltage adjustable within +5% (e) Frequency regulation +1%
(iii) Diesel Engine: Diesel Engine water cooled to drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multo stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- (a) Fly wheel with housing (b) Cooling system :- Moulded radiator with fan & belts (c) Cooling water pump :- Centrifugal type belt driven (d) Fuel system :- Fuel injection system with fuel injection fuel injection solenoid switch controlled by governor electric operated for 1% speed/frequency regulation (i) Fuel filters (ii) Fuel hoses (e) Lub oil system:- Lubricating oil filter, Lubricating pump (f) Air intake system:- Sir intake manifold, Air cleaner dry type (g) Governor electronic type (h) Starting System :- Electric self starter 240 Volts with and including batter charging alternator (j) Batteries:- Batteries of maintenance free dry type of capacity 12 Volt 100 AH-01 No complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite complete all as specified.
(k) Start and stop push button (l) Ignition key/switch (m) Radiator with blower fan (n) Corrosion inhibitor coolant (o) Fly wheel housing and fly wheel (p) Generator minitoring panel :- Comprising of all standard items as mentioned under this schedule as per standard practise/OEM standard specification Ignition key switch and start/stop arrangement, indicator for Engineer parameters, hour run meter, RPM meter, Engine Oil pressure indicator, water/coolent temperature indicator, Battery volt display as per standard manufacturing. (q) Safety controls :- Engine low lubricating oil pressure high water temperature and over speeding of engine. (r) Coupling arrangement:- Flexible coupling, fly wheel to suit flexible coupling as per manufacturing guidelines. (s) Accessories:- AVM Pads built or separately mounted to base frames as per manufacturer guidelines. (t) Base Frame:- Made out of ISMC of study design made of MS channel with necessary reinforcement and predetermined holes as per standard manufacturing (u) Fuel Tank:- Size and design as per standard manufacturing as per OEM with minimum capacity for 08 hrs operation.
(iv) AMF Panel:- Factory made indoor type micro processed based panel(fabricated from CPRI approved manufacturer), conforming to relevant IS, CPRI type test approved. Made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 115 Volts, 3-Phase 4-Wire AC 50 Hz, including powder coated painted, copper bus bar of TPN, 100 Amps complete with internal wiring with PVC insulated single core copper conductor multistranded wire of 1100 volts grade of suitable capacity, fuses, named 25 KA 03 Nos and contactors of capacity 100 Amps, 25 KA-02 Nos as recommended by the manufacturer alongwith single set Gen set controller viz binary inputs/outputs 7/7 anolog inputs 3, AMF function/MF function/MRS function input and output configuration voltage measurement Gen/mains 3 Phase current measurement 3 Phase IDMT over current, KW/KWH/KVA measurement, Generator protections, CAN-J1939 interface and auto temperature test heating/cooling as per manufacturer instructions, Detachable cable gland plates, all controls, indicators and standard fittings complete all as per manufacturer's instructions and as directed by Engineer-in -Charge
(v) Civil Works: All civil works including PCC platform and related to foundations including of panel and equipments including making good and existing structure of disturbed during installation and commissioning of Gen set is to be deemed to be quoted rate. The depth of the foundation and PCC shall be recommended by the manufacturer. (vi) Rubber matting of LV Grade 19mm thick of suitable size chequered type ISI marked to be laid in front of control panel should be provided All.
(vii) Acoustic Enclosure:- Manufactured by OEM suitable for 100 KVA DG Set (a) NAL approved as per CPCB (b) It should be as per latest rule and regulation of ministry of environment and forest and pulloution control board (c) The generating set batteries and control panels should be inside the enclosure (d) Fuel tank should be inside the enclosure (e) Construction details/specifications are as follows :- (f) Outer body:- CRCA sheet of 1.6 mm thick (g) Doors :- CRCA Sheet of 1.6 mm thick (h) Sound insulation:- 100mm thick rock wool (minimum density 64 Kg/Cum) Suitable foam insulation as per OEM to achieve the desired Db level as per IS-8183 (j) The aucostic should be composite in construction and fully assembled integral unit. (k) The batteries should be placed inside the enclosure beside the DG set on a suitable insulated platform. (l) The DG set should be provided with external emergency stop push button. (m) The enclosure should be suitably illuminated by CFL/FTL lamp fittings. (n) The noise level should be 75 Db at 1m under free field conditions (o) The aucostic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.
Note- (i) The complete DG set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE. (ii) Anything missed out above but technically required for efficient working of DG set is deemed to be included in quoted rates (iii) The quoted rate shall be deemed to be inclusive of first fill of engine oil and final successful acceptance test. (iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS in presence of E/M Offr detailed by accepting officer, all testing arrangements/equipments shall be made available by the contractor for tests)
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x60 cm x6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized earth lead strip of size 32 x 6 mm by mean of bolts , nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate no 3 of SSR part I 2009 connected to earthing test point all as specified complete with excavation and earth work PCC pit with 50 mm thick RCC cover (grade M-15) having suitable handle (10 mm MS Rod) 20 mm dia GI medium grade watering pipe with GI funnel with wire mesh 40 mm bore GI Pipe (medium grade) for protection of earth strip conductor all as directed and testing on completion.
M&L Galvanised iron stip 32 x 6 mm burried in ground all as specified and directed by Engr-in-charge
M&L for LT underground Cable XLPE insulated, heavy duty armoured sheathed 1100 volts grade 25 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete with all as specified.
M & L for LT underground Cable XLPE insulated, heavy duty armoured sheathed 1100 volts grade 50 Sqmm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete with all as specified.
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
M&L Sub class 'B' bricks well burnt perpendicular to the axis for the cable in trenches for protection to cable complete.
Supplying & Laying in trenches Clear Sand for cushioning under ground cable 8cm below and 15 cm above complete in level all as specified.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all complete as specified and described.
Supply and fix sheet metal enclouser indoor type including MCCB 100 Amps, four pole, 415 volts, 50 Hz, 25 KA breaking capacity complete all specified and as directed.
Supply and installation of encapsulated compound based CPRI tested and maintenance free pipe-in-pipe technology upgraded (Zinc/Alloy coated, 80-100 mocrons, Chemical Earthing System confirming IS 3034 ASEEL-39.The outer and inner pipe dia should be 76.3 mm and 41.9 mm dia with length 3 mtr zinc coated with additional alloy coating of 300 mm on the top side for additional protection of the terminals. The annular space between the pipe being filled of up with Crystalline Conductive Compounds. The Compact fill compounds which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity. The job incudes digging the pits and refilling the same by back filled compound(Ground enhancer), the BFC should be eco friendly it should not contain any environmentally hazardus material/metal having certification from NABL accredited lab. The earth should be provided with the masonry enclosures with FRPP pit cover for protection and safe guard of terminals.(In areas where soil condition is poor, good earth to be arranged to fill the excavated puts by mixing the same with BFC)1 bag BFC extra per pit/unit.(All the above dimension may vary ± 1 mm) Make: Ashlok(SEE) / JMV or equivalent .
Supply, fixing and testing of earthing improving Back fill compound (Conductolite) of 25 Kgs bag for improving earthing result by excavation till 30 cm from the top edge of the earthing electrode both side and filled with Back Fill Compound (Conductolite) complete and making good as per the existing one as before execavation. Testing and writing the result on wall/test result plate all complete as specified and as directed. Make : ASHLOK Back Fill compound ( Conductolite).
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specified & directed.
Material & Labour for earth result marker board of MS sheet 3.15 mm thick with suitable size of MS angle iron of 25 x 25 x 3mm thick and 0.8 mtr long and 0.3 mtr below ground level after proper grouting in ground with suitable PCC work and painting with suitable colour including taking down complete all as specified and as directed. Note :- Shapes , size and colour of paint as per existing or as directed.
S & F porcelain ridge insulator suitable for earthing strip with 01 No. GI bolt including nut & washer and 02 Nos GI bolt including nut & washer for holding /fixing copper/GI / Aluminium strip on roof/wall complete all as specified and directed.
Supply, fixing and brazing in replacement of Earth continuity conductor with adequate size insulator fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required 32mm x 6mm GI strip complete all as specified and directed.
M&L for fresh agriculture soil and fred from stone particle any impurities all as specified and directed
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule A notes for details.
M/S SUNNY ENTERPRISE
SHRI P P SHARMA
NIRANJAN SARKAR
SUNIL DAS AND CO
M/S MANAS MITRA
M/S P K ROY AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .