Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAccepted-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | ₹4.7 Cr | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹4.9 Cr+₹13.7 L (2.90%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹4.9 Cr+₹13.7 L (2.90%) | L2 | Rejected-Finance OTHER THAN L1 BIDDER |
| 3 | L3₹4.9 Cr+₹15.5 L (3.27%)Rejected-Finance 54 AKASH DEEP COLONY CHAKRATA ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹4.9 Cr+₹15.5 L (3.27%) | L3 | Rejected-Finance OTHER THAN L1 BIDDER |
| 4 | L4₹5.3 Cr+₹57.5 L (12.1%)Rejected-Finance | ₹5.3 Cr+₹57.5 L (12.1%) | L4 | Rejected-Finance OTHER THAN L1 BIDDER |
| 5 | L5₹5.5 Cr+₹78.9 L (16.6%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹5.5 Cr+₹78.9 L (16.6%) | L5 | Rejected-Finance OTHER THAN L1 BIDDER |
Tender Value
₹5.4 Cr
EMD Value
₹6.0 L
Closing Date
4 Feb 2025, 6:00 pmClosed
CHIEF ENGINEER
HQ CHIEF ENGINEER BAREILLY ZONE BAREILY
PROVN OF 19 X OR MD ACCN FOR 1201 DSC PL ATT TO DCN SUB GP DABATHWA AT MEERUT
2024_MES_690131_1
CEBZ/MRT/T-26 OF 2024-25
Open Tender
Civil Works
Lump-sum
365 days
DABATHWA
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE U E M MEERUT
₹6.0 L
Yes
19 Apr 2025
23 Dec 2024
11 Feb 2025
23 Dec 2024
4 Feb 2025
28 Jan 2025
Amount
SCHEDULE A PART-I (BUILDING WORK)
Construction of 19XOR Md Accn with Permanent specification complete all as specified and shown on drawings as following:-
(a) Block of 04 X OR Md Accn
(b) Block of 03 X OR Md Accn and Car & Scooter Shed
Construction of Car Shed with Permanent specification complete all as specified and shown on drawings.
Construction of Car and Scotter Parking Shed with Permanent specification complete all as specified and shown on drawings.
SCHEDULE A PART II A (Internal Water Supply) for details refer Sch A in pdf folder
SCHEDULE A PART II 'B' (Internal Water Supply)
S&F 15mm dia brass chromium plated 2 in 1 wall mixer fancy type with arrangement of L Bend for mixing hot or cold screwed for iron pipe suitable fpr 15 mm bore pipe complete all as specified and directed.
S&F 15mm dia brass chromium plated central hole wash basin mixture fancy type with or without lettered hot or cold with long screwed shanks and lfy nut capstanhead scewed for 15 mm bore pipe fix etc complete all as specified and directed.
S&F 15mm dia brass CP sink mixer swinging spout (wall mounted model) with connecting legs and wall flanges screw down for iron pipe and fix complete all as specified and directed
SCHEDULE A PART III 'A' (Internal Electric Supply) for details refer Sch A in pdf folder
SCHEDULE A PART III 'B' (Internal Electric Supply)
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk 1.8 mm (ISI marked) thick pressed steel zinc coated terminal box for mounting fittings i.e, modular switch / sockets incl cover plate & inner plate with frame including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - Note: Rates is included with modular plate and frame.
(a) One light point point /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch.
(b) One three pin 5 Amp socket on same board with other switches.
(c) One three pin 5 Amp socket on independent board.
(d) All as per above but for two way wiring.
All as per item No-12 here-in-before above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
All as per item No-12 here-in-before above but for one geyser point wiring with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm.
Supply and fix one module modular switch 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.
Supply & fix one module modular switch 05 / 06 Amps single pole, two way 240 volts complete all as specified & directed.
Supply and fix two module modular socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed.
Supply & fixing of two module modular socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed .
Supply and fix in one module modular switch 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.
Supply and fixing two module modular bell push flush type , 5 amps , 240 volts complete all as specified and directed.
Supply and fix ding dong bell,AC , 230 volts ,Single pole complete all as specified and directed.
Supply & fix lamp holder (Angular / Straight), insulated body, with back plate complete all as specified and directed.
Supply & fix modular step type Fan step regulator, 120W - 2 module complete all as specified and directed.
Supply and fix modular blanking plate on the existing modular plate & switch box excluding modular plate as required complete all as directed.
Supply and fix ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified
Supply and fixing of MCB TPN, 100 Amps, 415 Volt,10 KA 'C' curve complete all as specified and directed.
S&F DB TPN, 415 volt with 250 amps rated copper bus bar for double door 4 way IP-54, IK-09 suitable for one MCB TPN as incoming and outgoing MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 12 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 04 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F MCB SP, 40 Amps,240 Volt 10 KA 'B' curve conforming to ISI marked complete all as specified & directed .
S&F MCB SP, 5 to 32 Amps,240 Volt 10 KA 'B' curve conforming to ISI marked complete all as specified & directed .
S&F MCB SPN, 40 to 63 Amps,240 Volt 10 KA 'B' curve conforming to ISI marked complete all as specified & directed .
S&F MCB SPN, 32 Amps,240 Volt 10 KA 'B' curve conforming to ISI marked complete all as specified & directed .
Supply & fix LED light fitting 1x20 watt, 220 volt AC decorative box type 4 feet wall mounted high output diffuser integrated type, minimum 120 Lumen/ Watt (6000-6500 K) aluminium suitable surge protection Power factor > 0.9, IP-20 with driver, holders, including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.
Supply & fix LED light fitting high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type wall mounted high output diffuser integrated type, minimum 100 Lumen/ Watt (6000-6500 K) aluminium 3.5 KV voltage surge protection Power factor > 0.9, IP-20 with driver, holders, including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed.
Supply & fix LED lamp 12 watt, 220 volt AC decorative type Polycarbonate body and aluminium heat sink, frosted glass. CCT (6000-6500 K) minimum > 100 Luman/Watt PF>0.9, IP-20 complete all as specified and directed.
Supply and fix exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades and frame and louvers
Supply and fix exhaust Plastic body AC single phase 230 V of size 250 mm sweep with blades and frame and louvers
Supply and fix BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep, min air delivery 245 CFM five star rated with squirrel cage induction motor complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC Pits with cover iron cover inside edge and RCC cover with iron body edge in PCC (1:2:4) type B-1 and necessary earth work in any type of soil, medium grader GI watering pipe 20 mm dia with wire mesh and 15mm bore GI pipe light grade protection pipe upto last point incl charcol, common salt surrounded with 15cm all around the plate at alternate stage all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Supply, fix, connecting and testing building LED security light fitting 35 W with pressure die cast aluminium housing, heat resistant toughened glass with optic lens IP 66 protection and impact resistance of IK 07 with 10KV Built-in Surge Protection Device, PF>0.9, better optics for uniform distribution compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting including 32 mm bore GI light grade bracket upto 1 mtr for fixing of light with connected accessories on wall complete all as specified and directed.
SCHEDULE A PART IV 'A'(Site Clearance and Development) for details refer pdf folder
SCHEDULE A PART IV B (Site Clearance and Development)
SCHEDULE A PART V 'A' (Road, Path and Culvert) for details refer pdf folder
SCHEDULE A PART V B (Road, Path and Culvert)
S&F cat eye solar reflective type of metal body alloy of size 100mmx100mmx20mm with PAMA striplens reflector of model No DA 972.0 fixed with and incl MS stud of suitable size as per manufacturers instructions all as specified and directed.
S&F metal tubular dealineator made our of ABS round body fitted with 2 Nos 65mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600mm height duly powder coated and thermo plastic elasomer 3 bands of green, red and yellow reflector radium tape of 25mm wide strips with anti theft steel net for reflector protection including embeeding in PCC 1:2:4 (150x150x300) type B-1 complete all as specified and directed.
M&L for preparing bituminous surfaces of road and marking 2.5mm and 100 mm wide thick centre lines, stop lines, dashes, arrows etc and the like on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufactures instruction complete all as specified and directed.
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder
SCHEDULE A PART VI B (Sewage Disposal)
Construction of RCC septic tank fo 100 User excavation in any type of soil foundation in PCC 1:2:4 RCC wall and slab covers including RCC precast manhole covers having 6 mm plate embeded all around / fabric reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified and directed.
M&L for soakage well excavation in ordinary soil foundation in PCC 1:3:6 walls of honeycomb masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick massonary in CM. RCC cover shelves in M-25/SFRC cover interconnecting pipe of RCC/ DWC complete filled with brick bats of size 2.40x6.00m complete all as specified and directed.
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder
SCHEDULE A PART VIII (Fencing / Gate/ Compound wall) for details refer pdf folder
SCHEDULE A PART IX A (Hot Water Supply) for details refer pdf folder
SCHEDULE A PART IX B (Hot Water Supply)
Supply, installation, testing and commissioning of water heater storage type BEE five star rating electric suitable for single phase, 50 HZ, AC supply, stainless steel inner assembly, 1.5 KW heating element, Twin thermostat for water temperature and safety thermostat stove enamel outer body with digital temperature indicator including minimum 1 M of three core 2.5 Sq mm twisted copper conductor cable PVC sheathed three pin plug top, polyethylene pipe connection piece 450 mm long of 6 kg/ sq cm with two sets of chromium plated adopter at each end suitable for 15 mm bore GI Pipe at cold water inlet and copper tubing connection with chromium plated adopter at each end washer at hot water outlet, with safety fusible plug NRV confirming to relevant IS of 25 hrs capacity.
Supply and fixing of sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one singlke pole MCB 20 amps complete all as directed.
SCHEDULE A PART X A (External Water Supply) for details refer pdf folder
SCHEDULE A PART X B (External Water Supply)
Material and labour for construction of brick massonery valve pit of size 1 Mtr X 1 Mtr X 1 Mtr (Internal dimensions ) including all excavation and earth work in any type of soil and disposal of soil to a distance of not exciting 50mtr and depositing all as directed including 10mm plastering internally in CM 1.4, PCC type 1:2:4 ratio and 100mm thick at bottom and top of valve pit, including and MS Sheet cover of 3.0mm thick with angle iron frame 35X35X5mm and 40X40X5mm at bottom for minting and MS sheet cover inlet handle inlcuding two coats of synthetic enamel paint over a coal of red oxide primer on steel surface complete all as specified
SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder
SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY)
Supply, installing, testing and commissioning, factory made and tested . LT feeder pillar box (KIOSK) 1000mmx800mmx400mm size, outdoor type, (U shape) platform mounted in suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 600 Amps rating installed on porcelain insulators having statndard size 80x10 mm. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indiated in Hindi and English with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directedincluding connections of all out going/in coming existing cables of size 25/35/50/95/120/ 150 sqmm by drawing /digging out cable from loops in trenches out side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size copper lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, . Contd...
All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint and taking out of old skelton type panel with control switches complete all as specified and as directed Engr-in-Charge , The scope of work includes the following:- Note: Rate of items No. 71 to 78 are to be included in this item
Incoming MCCB 4 Pole thermal magnetic siting, overload & short circuit protection, 415V, 250 Amps, with rupturing capcity 35 KA Nos -1
Outgoing MCCB 4 Pole, 415V, 63 Amps thermal magnetic siting, overload & short circuit protection, 50 Hz with rupturing capcity 25 KA Nos-6
Busbar aluminium 600 Amp with air insulated for TPN mounted on porcelain insulator one set
Digital Voltmeter 3 Phase program type 0-500 V-01 & Digital 3 phase perfromable type Ampere meter 0-500 Amp suitable CT's-01 No
RYB Phase indicating lamp LED type - 03 Nos
Panel wiring with 2.5 sqmm copper cable PVC single core
Fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure with all concerned accessories as required.
PCC of platform with foundation 1:2:4 Job
Supply and erecting in true vertical position tubular swaged poles type 410 SP-31 (9 Mtr long) complete with CI base plate goose neck bracket, finial taper plug, bolt, nuts and screw and painting internal surface with anti-corrosive paint and external Painting of poles with one coat of red oxide primer and two coat of aluminium synesthetic paint before fixing and one coat of aluminium synesthetic paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of Green & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m heightcomplete all as specified and directed by Engr-in-Charge. Note: Excavation and earth work and concrete foundation and pedestal shall be measured and paid for separately
Supplying fixing in repair connecting and testing of energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium with toughened glass cover housing, 70 watts LED to achieve electrical safety class 1, CRI>70 colour temperature 5000k to 6000k with LED working life time >50000 burning hours with integrated constant current electronic driver, nominal volatge 240V, AC,50 Hz, operating voltage range 120-280V, suitable for ambient environmental condition of station, TDH<10%,, Pf >0.95, lumens >80 lm/W, Ingress protection not less than IP65, driver and luminaire shall comply not less than LM-79 or IS 16106 of 2012 including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with Two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers or providing reducers and GI pipe of size suitable for exixting top fixed bracket duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed. Note: LM-79 & LM 80 Test report with more than 50000 burning hrs LED light from NABL lab shall be provided.
M&L for Weather proof flat twin core aluminium cable conductor of size 2.5 Sqmm for connection of Securiry light to OH or Pole Box all acomplete as specified and directed.
M& L for pole box fabricated out of PVC 1.8 mm thick MS Sheet having for out door installation having 3 nos busbar 50 Amp Aluminium bus bar conductor mounted on insulators, one no 20 x 3 mm aluminium bus bar with 2 clamps of aluminium strip for earthing of the armoured of cable complete. making connection of cables etc nuts bolts etc size of box 250 x 150 x 100 mm front openable hinged cover suitable for mounting on steel tubular poles using clamps nut bolt etc , PVC adopters and PVC hose pipe upto cable trench for incoming and outgoing cable , MCB SP 6 Amp , factory made duly painted powder coating process complete all as specified and directed.
Supply and errecting in vertical position steel tubular pole swaged type 11.0 Meter long, type 410 SP-55, IS-2713 marked complete with M&L for mild steel base plate (fillet welded to poles), pole cap/final taper plug, bolts, nuts, washers etc. Internal surface painted with anti- corrosive paint and Paint of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of black & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m heightcomplete all as specified and directed by Engr-in-Charge. Note: Excavation and earth work and concrete foundation and pedestal shall be measured and paid for separately.
Supply, installation, testing and commissioning outdoor type platform mounted step down transformer of capacity 160 KVA, 11 KV/415 Volts (at NO load), AC 3 Phase, 50 HZ, core type double copper wound, oil immersed, naturally cooled, oil natural-Air natural (ON/AN) with external cooling tubes, delta connection on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn-11 with Neutral brought out on secondary side (LV side) and having tapings at (-)5% and 5% on 5 step on HV side to be changed by means of hand operated OFF load tap changer gear and transformer should conforming to level-2 of IS-1180 : 2014. The maximum temperature rise should not exceed 45 degree celsius with including construction of transformer platform as per OEM recommended in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 degree celsius. Transformer shall comprise of the following item No. 80 to 89
(a) One cable box LT side (secondary side) consisting of four Nos porcelain bushing with copper rods complete with nut & washers with one No cable gland suitable for reception/ taking out of 240 Sqmm 3 1/2 core LT 1100 Volts grade XLPE insulated and PVC sheathed heavy duty armoured cable including gland, joint & jointing material complete all as specified.
(b) HT side (primary side) consisting of three Nos porcelain bushing with copper rods complete with nut and washers with cable gland HT busing suitable for outdoor mounting transformer, 11000 Volts grade XLPE insulated heavy duty armoured cables including gland joint and jointing material complete
(c) Oil conservator with filter type drain valve and oil level guage complete
(d) De-hydrating breather with first fill of dehydrating agent (silica gel) complete
(e) Explosive vent & thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, air release valve plug and four Nos solid cast steel detachable rollers
(f) One 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device
(g) Four earthing terminals on tank cover to facilitate fixing of 32mm x 6mm galvanised iron earth strip for earthing of neutral & body
(h) Rating plate and terminal marking diagram plate
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthig for neutral.
(k) First filling of new and unused transformer oil IS-335 marked filtered and tested upto 60 KV dielectric strength at 2.5mm air gap between testing electrodes.
Supply and Install APFC Panel with MPPH capacitor and MCCB as incommer Cap:100 KVAR with 5 steps with relay & control device, contractor etc complete all necessary acessories as required capacity
M&L earthing of pole GOD and other equipments complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe medium grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:3:6 type C1 earth pit and Precast RCC cover 40 mm thick in plain cement concrete 1:2:4 type B1 duly reinforced with 8mm dia TMT bars @ 150mm c/c with 10mm dia MS round bar as in lifting handles, mild steel angle iron frame for pit cover made out of 40x40x5mm thick duly painted with two coats of ssynthetic enamel paint over a coat of priner , excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 03 of SSR Part I
All as per item no 96 above but using galvanized strip 32x6mm as earthing lead with GI Pipe protection 40 mm dia light grade and watering GI Pipe 20 mm medium grade and complete all as specified and directed.
M & L for boaring in any type of soil under road 1.5 Mtr below the top surface of road by conventional method complete for passing through 40mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed.
M&L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable) completed all as specified and directed. Note:- Punned thickness only will be considered for payment.
Supplying and laying un-reinforced precast concrete cable covers class HV, Type I, flat, size 300mm x 180mm x 40mm, ISI marked complete all as specified and directed.
M&L burnt clay fly ash Modular bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supply & fixing HT PCC cable route indicator of size 175mm x 150mm thick, 75 cm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel yellow and red paint along HT cable trench after every 100Mtr and corner & on any turnning, road crossing etc including planting in ground with PCC (1:3:6) type C-1 complete all as specified and directed.
S&F Lightning arresters expulsion type 11000 volt complete with all fittings, transmission class,discharge capacity 65 kilo amp.
Supply and fix HT 11 KV outdoor type gang operated air break switch suitable for vertical mounting complete with 9 insulator of rating 400 Amps.
S&F cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.
SCHEDULE A PART XII (Arboriculture)
Supply and plantation of green sapling of plants and shurbs of Gurhal 2' to 3' high incl preparation of compost of size 300mm x 300mm x 300mm by excavation, applying ATT, planting the trees / plants refilling the pit with compost manure sand and sweet earth in the ratio 1:1:4 breaking the clots, ramming and flooding with water and filling with more compost earth if necessary, fine dressing incl removal of rubbish / unserviceable material. ATT shall be in form of 200 gms Neem cake mixed with every cum of compost followedby dursban 20 EC applied at 2ml/litre in the first watering of 20 ltr per pit. As per user requirement :
-ditto- as above but Guava
Supply and plantation of green sapling of plant and shurbs of Areca 2' to 4' high incl preparation of compost of size 300mm x 300mm x 300mm by excavation, applying ATT, planting the trees / plants refilling the pit with compost manure sand and sweet earth in the ratio 1:1:4 breaking the clots, ramming and flooding with water and filling with more compost earth if necessary, fine dressing incl removal of rubbish / unserviceable material. ATT shall be in form of 200 gms Neem cake mixed with every cum of compost followedby dursban 20 EC applied at 2ml/litre in the first watering of 20 ltr per pit all as specified and directed. As per user requirement
SCHEDULE A PART XIII (PC Sum) (Refer Sch XIII)
Supply & Fixing Fountain having dia 3.00 mtr, 1.50m depth including Excavation, RCC Water Tank, RCC Pardi as retaining wall, Water Proofing to Water tank , fixing glazed ceramic tiles in water tank , providing Pump 7.5 Hp and Necessary elcrification and necessary plumbing work costing to Rs. 357500.00 will be added in Quoted amount. (One Job)
Sudhir Sharma Associates (BID ID -3230776)
M/S SURAT SINGH AND SONS (BID ID -3231325)
CHITTER MAL & CO (BID ID -3226608)
imran construction company (BID ID -3231321)
m/s gupta construction (BID ID -3227780)
M/s Arihant Builders (BID ID -3229204)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .