Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹12.6 L+₹61,661 (5.16%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.8 L+₹4.9 L (40.7%)Rejected-Finance H NO 1 24 48 VENKATAPURAM PO TIRUMALGIRI SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
9 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME Secunderabad
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
PROVN OF CERTAIN SANCTIONED WORK IN RECOVERY CAMP AREA UNDER GE MCEME SECUNDERABAD
2020_MES_403337_1
GE/MCEME/29 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
Class E Category a(I)
6 documents required · 6 mandatory
₹500
GE MCEME Secunderabad
₹23,000
Yes
4 Mar 2021
14 Dec 2020
12 Jan 2021
14 Dec 2020
9 Jan 2021
26 Dec 2020
60 days
Amount
Demolition of brick work or stone masonry of any description and in any situation built in cement mortar complete all as specified and directed.
Excavation in trenches n exc 1.5m in deepth and 1.5m in width and getting out in hars/dense soil complete all as specified and directed.
Ditto as per item no. 2 above but in hard rock complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm. complete all as specified and directed.
M&L for Anti Termite Treatment in Treating the top surface of filled earth at rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for Anti Termite Treatment in Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L Reinforced cement concrete (nominal mix 1:1.5:3)in using 20 mm graded stone aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
M&L reinforced cement concrete(nominal mix 1:1.5:3)in using 20 mm graded stone aggregate in Columns, pillars, piers,posts and struts etc complete all as spd and directed.
S&F mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking bending and binding with mild steel (annealed) wire not less than 0.90mm dia.complete all as specified and directed.
Form work to side of concrete fdn, flooring base, base of columns, side and soffits of plinth beam and simillar work rough finished surfaces complete all as specified and directed.
Form work to side of columns fair finished surfaces complete all as specified and directed.
S & F for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes, Fe 290 (Gde-E-165) ,etc complete all as spd and directed.
M&L for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) in foundation, mass concrete and filiings all as specified and directed.
M&L for PCC 100mm thick type D2 1:4:8 40 mm graded stone aggregate as in sub base complete all as specified and directed.
Dismantling of asbestos cement (corrugated,semi corrugated etc.) sheets in roof coverings complete all as specified and directed.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed.
S&F of Mild Steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties;complete all as specified and directed.
S&F for Framed work such as in Mild Steel grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L reinforced cement concrete(nominal mix 1:1.5:3)in using 20 mm graded stone aggregate as in beams, cantileavers, bressummers, lintels over 1.5 clear span etc complete all as spd and directed.
S&F in repairs Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, etc complete all as specified and directed.
S & F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240,etc complete all as spd and directed.
Fabrication and fixing only for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240,etc complete all as spd and directed.
S & F for Welded steel wire fabric supplied and fixed complete to wood or steel members, Weight per square metre exc 4 kg,etc complete all as spd and directed.
M & L Preparation of steel surfaces or iron based material of any description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over and including cement screed base 15mm thick in 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed.
M&L for Machine cut cudappa stone slab 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed.
M&L mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape requred, including cranking bending and binding with mild steel (annealed) wire not less than 0.90mm dia complete all as specified and directed.
M&L mild steel TMT bars 6 to 10mm dia as in stirrups, spacers and binders including binding with mild steel (annealed) wire not less than 0.90mm diacomplete all as specified and directed.
Form work to side and soffits of lintel, shelves for fair finished surfaces complete all as specified and directed.
Formwork to ,rough finished surfaces of flat concrete,soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping),etc complete all as spd and directed.
Formwork to,rough finished surfaces of concrete, edges of concrete flats, treads, breaks in floors, window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,etc complete all as spd and directed.
M&L 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement as in plinth protection complete all as spd and directed.
M&L Damp proof course 25mm thick in cement concerte 1:2:4,type B0 using 12.5mm graded stone aggregate to horizontal or vertical surfaces including necessary formwork etc.complete all as spd and directed.
M&L Brick work with fly ash old sized bricks straight or curved on plan exc 6M mean radius built in CM 1:6 complete all as specified and directed.
M & L Brickwork in cement mortor 1:4 with fly ash old sized bricks, straight or curved on plan to any radius in half brick thick walls built in etc complete all as spd and directed.
M&L for rendering 15mm thick on brick/concrete surface in cement mortar 1:4 finished even and smooth with using water proofing compund as per manufacturer instruction complete all as specified and directed.
M&L for rendering 15mm thick on brick/concrete surface in CM 1:6 to wall finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in ceiling in cement mortar 1:3 finished even and smooth complete all as specified and directed.
M&L for two coats of oil bond distemper on cement plaster over a coat of primer over and including 3 mm thick Birla wall care putty after preparation of surface on wall complete all as specified and directed.
M&L for painting to cement plaster surfaces with two coats of cement base paint over a coat of alkali resistant primer after preparation of surface complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Spreading and levelling earth filling in floors in layers and well ramming including watering as required (soil obtained from item No 1) complete all as specified and directed.
M&L for Hardcore of broken stone guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface.complete all as specified and directed.
M&L providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) , 75mm thick as in sub base in floor/paving etc complete all as specified and directed.
M&L providing cement concrete 1:2:4 type A1 (Using 20mm graded stone agg) , 25mm thick as in sub base in floor/paving etc complete all as specified and directed.
M&L coloured ceramic glazed tiles 450x300x7mm thick on vertical surfaces such as skirting, dados and rises to steps etc set in jointed in neat cement sluury over and including cement plaster 10 mm thick in CM 1:3 and pointed to match the colour of tiles complete all as specified and complete.
S & F for Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc., size of frame 125 x 60 mm complete, as specified and directed.
M&L filling in frame of door cement concrete type A-0 1:1.5:3 (12.5 mm greded aggregate) complete all as specified and directed.
M&L Mild Steel hold fasts, wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercials type on both sides complete all as specified and directed.
S&F factroy made glazed/guage 2nd Class hardwood 35mm thick skelton shutter open rebated and prepared to receive glass, guage etc divided in to suare wth sash bars plain chamferedor rounded, mitred and rebated sash bars complete all as specified and directed.
M&L preparation of new wood surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specifed and directed.
S&F butt hinges medium weight, cold rolled aluminium 100mm long complete all as specified and directed.
S&F in repairs 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fix clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n exc 15cm thickness built in cement mortar complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 ltrs including dismantling old RCC tank of any capacity complete all as specified and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Supply and fix 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
S&F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed as in repairs complete all as specified and directed.
M & L for cement mortar 1:4, Flush pointing to squared rubble masonary coursed or uncoursed etc complete all as specified and directed.
M&L PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/ bed block including form work complete all as specifed and directed.
Supply and fixed 15 mm bore Bib taps, fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F Tubes, ‘Medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors of 15mm bore complete all as specified and directed.
S&F sink with drainage board made out of stainless steel (Non megnatic)1mm thick sheet for kitchen with plugs, washers and waste pipe including cast iron cantilever brackets and connecting union to waste pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified and directed.
S&F Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls,ceilings or in floors etc.,, Bore of pipes in 40 mm, etc completed all as spd and directed.
S & F 110 mm bore PVC (SWR) pipe single socketed,in any length with rubber ring joints, laid in trenches or in floors incl taking down existing u/s pipe complete all as specified and directed.
S & F for PVC (SWR) bends any radius, bore of pipe in 110 mm, etc complete all as specifed and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas & depth not exceeding 1.5 M deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas & depth exceeding 1.5 M and not exceeding 3 M deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas & depth exceeding 3.0 M and not exceeding 4.5 M deep and getting out in hard / dense soil complete all as specified and directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
M&L for use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves incl supports etc for rough finished surface of concrete complete all as specified and directed.
M&L for reinforced cement concrete (Nominal mix) type B1 1:2:4 (20 mm graded aggregate) in lintel bands, roof beams and cantilevers etc.complete all as specified and directed.
M&L for salt glazed stone ware drain pipes laid in trenches and jointed as specified of dia150mm internal bore complete all as specified and directed.
S & F for PVC (SWR) vent cowl, bore of pipe in 110 mm, etc complete all as specifed and directed.
M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150 mm dia SWG pipe/pvc PIPE 110 mm dia complete all as specified and directed.
M & L for plain Cement Concrete Type C1 1:3:6 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded complete all as specified and directed.
S & F for rungs, bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, hains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.complete all as specified and directed.
M&L for reinforced Cement Concrete 1:2:4 20 mm graded aggregate nominal mix for slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 using 20 mm graded aggregate as in Cover slab for manholes etc set in cement mortor 1:4 including use and waste foam work (reinforced shall be measured and paid seprately) all as specefied complete all as specified and directed.
M &L for brick bats filling around the soakage pit all as specified and directed by Engineer In Charge
M&L for Cement concrete type D2 1:4:8 (40 mm graded stone aggt) 150 mm thick as in sub base to flooring complete all as specified and as directed by Engineer in charge
M & L 100 mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) hard standing, finished even and smooth with out using extra cement complete all as specified and directed.
S & F 5000 ltr capacity of rotational moulded PVC water storage tank (cylindrical vertical with closed top) hoisted and fixed in position (including PCC 1:3:6 bedding apprx dia 2.00 m apprx and thick 100 mm ) including float valve 150 mm dia and brass fittings complete all as specified and directed.
M & L for Point wiring on concealed conduit with 1.5 Sq mm copper conductor single core PVC insulated unsheathed 1100 V grade multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and factory made Powder coated steel terminal boxes including fixing/grouting sunken/ surface as per site requirement and covered with 3 mm thick laminated sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets etc all as specified for: (a) One light point/one ceiling fan point/One exhaust fan point controlled by one controlled by one, one way switch 5 A, SP
(b) One 3pin 5amps switch socket outlet piont controlled by one switch on independent board
(c) One 3pin 5amps switch socket outlet piont controlled by one switch on same board
Description all as per item No 89 here-in-before but using 2.5 Sq mm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps switch socket combination point including running of 2.5 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dollycomplete all as specified and directed.
S & F Switch piano type single pole one way 6 Amps capacity 230 volts complete all as specified and directed.
S & F Switch piano type single pole one way 16 Amps capacity 230 volts complete all as specified and directed.
S & F socket 6 amps -2/3 pin 2 module of capacity 230 volts complete all as specified and directed.
Supply and fix socket type multipurpose 2/3 pin combined 16 Amps, 230 Volts complete all as specified and directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed.
S and F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 Volts double door with locking system complete all as specified and directed.
Supply & Fix MCB SPN 240 volts C' series suitable for fixing on MCB DB's of capacity 32 Amps,C series 10 KA breaking capacity complete all as specified and directed.
Supply & Fix MCB SP 240 volts suitable for fixing on MCB DB's of capacity 6 to 32 Amps 10 KA breaking capacity complete all as specified and directed.
S & F building security light of capacity 45 watt including suitable GI bracket along with clmps,nuts and bolts etc all as specified and directed. Make: Crompton Cat No.LSTP-45-CDL or equivalent of Philips/Havells
Supply & Fixing LED batten of capacity 18 watts,indoor decorative Polycarbonate housing extruded and integrated type complete with all accessories , prewired fixed to wall/ceiling with 2 Nos PVC round blocks with necessary hanging/fixing arrangements & connecting to the point wiring with necessary flexible copper conductor of multisranded three core of suitable length from fitting to the ceiling rose complete all as specified. Make Crompton Cat No.LCTL-18-CDL or equivalent of Havells/Philips
S & F Supply & fix exhaust fans AC single phase 230/ 240 V of size 450 mm sweep with louver and connecting up with and including provision of PVC insulated copper flexible cord of size 23/0.019, 3 core from ceiling rose to connection of exhaust fan complete all as specified.
Supply & Lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with stranded aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 3 C X 10 Sqmm complete all as specified and directed.
Supply, spread approval river sand in cable trenches for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid.
Supply & Lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead 4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earth elelctrode to DBs/main switch incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of SSR Part-I and connection point complete all as specified and directed including testing on completion. Note :- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 4mm size and protection pipe of 15mm bore GI light grade.
VACON INFRASTRUCTURES
Sri Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .