Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹11.5 L+₹59,672 (5.49%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.8 L+₹1.9 L (17.7%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹13.0 L+₹2.1 L (19.6%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹14.7 L+₹3.8 L (35.0%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | M/s Devendera construction L1 | KUNAL ENTERPRISES L2 | P S TRADERS L5 | FOUJI ELECTRIC WORKS L3 | BHATIA ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks, DB, MCB etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed by Engineer-in-Charge. | 227 | PER POINT | 5 ₹1,135 | 7 ₹1,589 | 10 ₹2,270 | 5 ₹1,135 | 1 ₹227 Lowest |
| 2.00 | All as per item No 1.00 (here-in-before) but excluding existing concealed conduit. | 1,295 | PER POINT | 2 ₹2,590 | 7 ₹9,065 | 5 ₹6,475 | 5 ₹6,475 | 1 ₹1,295 Lowest |
| 3.00 | Material and labour for point wiring for one light point controlled by one, one way switch with multistrand 1.50 Sqmm unsheathed copper conductor PVC insulated FRLS cable including continuous earth wire 1.5 Sqmm in green colour unsheathed copper conductor PVC insulated FRLS cable connected to common earth dolly in PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS in on New wooden boards fixed on wall for mounting switch, socket, regulators etc with and and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed.
(Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).' | 100 | PER POINT | 185 ₹18,500 | 217 ₹21,700 | 150 ₹15,000 | 285 ₹28,500 | 110 ₹11,000 Lowest |
| 4.00 | All as per item No 3.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch. | 35 | PER POINT | 185 ₹6,475 | 217 ₹7,595 | 150 ₹5,250 | 285 ₹9,975 | 120 ₹4,200 Lowest |
| 5.00 | All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board. | 30 | PER POINT | 185 ₹5,550 | 227 ₹6,810 | 150 ₹4,500 Lowest | 285 ₹8,550 | 170 ₹5,100 |
| 6.00 | All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board. | 35 | PER POINT | 50 ₹1,750 | 27 ₹945 | 150 ₹5,250 | 100 ₹3,500 | 20 ₹700 Lowest |
| 7.00 | All as per serial item No. 3.00 (here-in-before) but for one bell/buzzer point controlled by one bell push. | 2 | PER POINT | 185 ₹370 | 217 ₹434 | 150 ₹300 Lowest | 300 ₹600 | 180 ₹360 |
| 8.00 | All as per srl item No. 3.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge. | 25 | PER POINT | 200 ₹5,000 Lowest | 277 ₹6,925 | 200 ₹5,000 Lowest | 400 ₹10,000 | 220 ₹5,500 |
| 9.00 | M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed
(Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ). | 850 | PER POINT | 150 ₹1,27,500 | 187 ₹1,58,950 | 90 ₹76,500 Lowest | 195 ₹1,65,750 | 110 ₹93,500 |
| 10.00 | All as per item No 9.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch. | 130 | PER POINT | 150 ₹19,500 | 187 ₹24,310 | 90 ₹11,700 Lowest | 195 ₹25,350 | 120 ₹15,600 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
6 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE HISAR
GE HISAR
REPAIR / REPLACEMENT TO E/M NATURE WORKS IN CENTRAL AMENITIES, KLPs AND ILPs AT HISAR MIL STN UNDER GE HISAR
2025_MES_734867_1
GE(H)-52/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
3000 days
GE HISAR
AS PER NIT
6 documents required · 6 mandatory
₹500
Yes
GE HISAR
₹50,000
Yes
11 Dec 2025
13 Oct 2025
14 Nov 2025
13 Oct 2025
6 Nov 2025
28 Oct 2025
Amount
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks, DB, MCB etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 1.00 (here-in-before) but excluding existing concealed conduit.
Material and labour for point wiring for one light point controlled by one, one way switch with multistrand 1.50 Sqmm unsheathed copper conductor PVC insulated FRLS cable including continuous earth wire 1.5 Sqmm in green colour unsheathed copper conductor PVC insulated FRLS cable connected to common earth dolly in PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS in on New wooden boards fixed on wall for mounting switch, socket, regulators etc with and and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No 3.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per serial item No. 3.00 (here-in-before) but for one bell/buzzer point controlled by one bell push.
All as per srl item No. 3.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No 9.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 9.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board from DB.
All as per item No. 9.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per srl item No. 9.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F bell push flush type, 5 Amp 240 Volts.
S&F Bell ding dong type, AC, 230 Volts, single pole.
S&F sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating Aluminum bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S&F sheet metal enclosure distribution board SP&N, 12 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating Aluminum bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S&F sheet metal enclosure distribution board TPN, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating Aluminium bus bar, complete all as specified & directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F MCB SPN, 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 29.00 (here-in-before) but cable of size 6 sqmm drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
All as per item No 29.00 (here-in-before) but cable of size 4 sqmm drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
All as per item No 29.00 (here-in-before) but cable of size 1.5 sqmm drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
Supply and fixing LED lights fitting (Cool day / warm white) 1x 40W, 220V, AC wall mounted LED batten with Aluminium housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting (Cool day / warm white natural white) 1x 10W, 220V,AC wall mounted LED batten with aluminium housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
S&F in replacement LED lumianire 600mm x 600mm, capacity 35/36 Watt,(warm white / cool day light/ natural light) 220 V AC, surface mounted type with high efficiency PMMA diffuser soft glase free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core flrxible copper conductor of suitable size complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, (warm white / cool day light / natural light) 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED luminaire 1Ft x 1Ft , 24 watt, (warm white / cool day light / natural light) 220 V AC surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S&F sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB 'C' curve complete all as specified.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
S&F in replacement street light LED light fitting 20 Watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 25mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed.
S&F in replacement rigid non-metallic PVC conduit 25mm dia with fittings like tees , bends, elbow, reducer, bell mouth tube ends and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete fixed on wall / ceiling all as specified and as directed.
S&F in replacement PVC casing and caping of 25mm width all tees, bends, elbows, reducers, bell mouth, tube end and fixing all accessories as specified and directed.
S&F Square shape 18 watt 220 volts downlight round with high efficiency of >100lm/W, die cast aluminium housing and high efficiency arylic diffuser ACsurface mounted type PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flixible copper conductor cable of suitable size complete.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
KUNAL ENTERPRISES (BID ID -3468756)
FOUJI ELECTRIC WORKS (BID ID -3468523)
BHATIA ENTERPRISES (BID ID -3468609)
P S TRADERS (BID ID -3473434)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
TENDERDOCUMENTSGE52.pdf
Tender Documents • 2.82 MB
BOQ_822872.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .