Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | ₹20.0 L | L1 | Accepted-AOC Lowest Tender |
| 2 | L2₹20.1 LRejected-AOC | ₹20.1 L | L2 | Rejected-AOC Second Lowest Tender |
| Sl No | Description | Qty | Unit | BHARAT CORP L2 | Vignesh Air conditioners L1 |
|---|---|---|---|---|---|
| 1.00 | A)Renewal by Supply of 5.5 TR norminal capacity Floor Mounted ductable air conditioner with the following components.. 5.5 TR capacity Floor Mounted Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower. power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector, Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor. | 2 | Nos | 3,36,500 ₹6.7 L | 3,36,400 ₹6.7 L |
| 1.01B)Renewal by Supply of 5.5 TR capacity Floor Mounted ductable air conditioner high tech Outdoor unit internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3phase motor with protection.Condencing temperature 130' F for the system operations. | |||||
| 2.00 | A)Renewal by Supply of 11.0 TR norminal capacity Floor Mounted ductable air conditioner with the following components.. 11 TR capacity Floor Mounted Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower. power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector, Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor. | 2 | Nos | 3,86,000 ₹7.7 L | 3,81,400 ₹7.6 L |
| 2.01B)Renewal by Supply of 11.0TR capacity Floor Mounted ductable air conditioner high tech Outdoor unit internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3phase motor with protection.Condencing temperature 130' F for the system operations. | |||||
| 3.00 | Renewal by Supply and filling of R-22Refrigerant gas. | 20 | Kg | 515 ₹10,300 | 515 ₹10,300 |
| 4.00 | Renewal by Supply and fixing of hard drawn copper refrigerant piping of 1 1/8” dia interconnecting indoor and outdoor units with necessary fittings, supports etc., | 30 | Rmt | 1,800 ₹54,000 | 1,780 ₹53,400 |
| 5.00 | Renewal by Supply and fixing of hard drawn copper refrigerant piping of 5/8” dia interconnecting indoor and outdoor units with necessary fittings, supports etc., | 30 | Rmt | 1,000 ₹30,000 | 980 ₹29,400 |
| 6.00 | Renewal by Supply and fixing of flexible canvas connection between indoor unit and ducting and rubber pads. | 4 | No's | 2,800 ₹11,200 | 2,767 ₹11,068 |
| 7.00 | Renewal by Supply and fixing of suitable MS angle frame for mounding the outdoor unit | 4 | No's | 6,600 ₹26,400 | 6,590 ₹26,360 |
| 8.00 | Renewal by Supply and providing thermal insulation for Refrigerant Pipes and Drain Pipes | 30 | Rmt | 60 ₹1,800 | 58 ₹1,740 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
30 Jan 2026, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Renewal of Air Conditioning Ductable AC in OTs in Kasturba Gandhi Hospital for Women and Children, Chennai-05
2026_PWD_645959_1
PWD/BCMC1/107-1/2025-26
Open Tender
Electrical Works
60 days
KGH Women and Children
Refer Tender Condition
8 documents required · 8 mandatory
₹0
₹20,000
30 Mar 2026
27 Jan 2026
30 Jan 2026
27 Jan 2026
30 Jan 2026
27 Jan 2026
A)Renewal by Supply of 5.5 TR norminal capacity Floor Mounted ductable air conditioner with the following components.. 5.5 TR capacity Floor Mounted Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower. power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector, Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor.
B)Renewal by Supply of 5.5 TR capacity Floor Mounted ductable air conditioner high tech Outdoor unit internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3phase motor with protection.Condencing temperature 130' F for the system operations.
A)Renewal by Supply of 11.0 TR norminal capacity Floor Mounted ductable air conditioner with the following components.. 11 TR capacity Floor Mounted Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower. power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector, Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor.
B)Renewal by Supply of 11.0TR capacity Floor Mounted ductable air conditioner high tech Outdoor unit internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3phase motor with protection.Condencing temperature 130' F for the system operations.
Renewal by Supply and filling of R-22Refrigerant gas.
Renewal by Supply and fixing of hard drawn copper refrigerant piping of 1 1/8” dia interconnecting indoor and outdoor units with necessary fittings, supports etc.,
Renewal by Supply and fixing of hard drawn copper refrigerant piping of 5/8” dia interconnecting indoor and outdoor units with necessary fittings, supports etc.,
Renewal by Supply and fixing of flexible canvas connection between indoor unit and ducting and rubber pads.
Renewal by Supply and fixing of suitable MS angle frame for mounding the outdoor unit
Renewal by Supply and providing thermal insulation for Refrigerant Pipes and Drain Pipes
Renewal by Supply and providing of control supply for indoor to out door unit HP and LP cut outs for 1.5sqmm copper flexible cable.
Renewal by Supply and providing of 10 sq.mm. 4 Core copper flexible cable
Renewal by Supply and Erection of Scaffolding works charges for the Ground Floor to Terrace
Copper Pipe line welding and N 2 gas for leak testing, leak arresting work Labour charges.
Renewal by Supply and Installation of 2.0 TR capacity 3 star rated energy efficient Hi wall mounting Split type Air Conditioner unit consisting of out door condensing unit complete with hermetically sealed Air compressor with R 22 refrigerant air cooled condenser, fan etc., and 1No Indoor Hi wall mounted 2.0 TR capacity evaporator unit complete with cooling coil, blower motor and connected accessories, control etc, with 3 metre copper refrigerant piping and chord wire connecting indoor and out door unit with drain pipe suitable for operation on 230V+ 10% 50 HZ single phase AC supply.(Make: Carrier/Equ)
Renewal by Supply and fixing of 5 KVA Automatic voltage stabilizer with time delay arrangements for operation on 230V 50C/S AC supply (Make V-Guard/Equ)
Renewal by Supply and laying of 5/8” and 3/8” copper with insulation etc., ( beyond the standard length of 3mts)
Renewal by Supply and fixing of out door base stand for split AC unit
Renewal by Supply of 3 core 2.5 sqmm copper cable (MR)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_774993.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Ackghschcondition.pdf
Tender Documents • 0.74 MB
BOQ_774993.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid