| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 CrAdmitted-Finance 16 PRATAP NAGAR CHARBHUJA RAWATBHATA RAJASTHAN 323307 | RAWATBHATA | CHITTORGARH | RAJASTHAN | 323307 | ₹6.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.4 Cr+₹21.4 L (3.46%)Admitted-Finance | ₹6.4 Cr+₹21.4 L (3.46%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Gupta Construction Co. L1 | Umawala Engineers Pvt. Ltd. L2 |
|---|---|---|---|---|---|
| 1.00SUPPLY | |||||
| 2.00TOWERS | |||||
| 3.00 | Fabrication, Galvanising, Inspection & supply of 132KV DC tower including stubs, extensions & stub setting template, as per drawing & BOM. | 385 | MT | 2,54,58,125 ₹2,54,58,125 | 2,40,62,500 ₹2,40,62,500 Lowest |
| 4.00 | Fabrication, Galvanising, Inspection & supply of 132KV Narrow Base / MC type Tower including stubs, extensions & stub setting template, as per drawing & BOM. The tower contains HT & MS material. | 40 | MT | 31,55,200 ₹31,55,200 | 26,40,000 ₹26,40,000 Lowest |
| 5.00 | Fabrication, Galvanising, Inspection & supply ofspecial designed 220KV DC Ultra Narrow base tower having back to back (Maximum 3.8 Meter) including stubs, extensions, templates, etc. The tower contains HT & MS material. | 60 | MT | 47,28,000 ₹47,28,000 | 39,60,000 ₹39,60,000 Lowest |
| 6.00 | Hot dip galvanized, Hexagon, Round hexagon head transmission towers bolts, nuts & washers for above structure as per BOM. | 20 | MT | 18,53,600 ₹18,53,600 | 16,20,000 ₹16,20,000 Lowest |
| 7.00TOWER ACCESSORIES | |||||
| 8.00 | Number Plate | 86 | Nos. | 18,060 ₹18,060 Lowest | 22,360 ₹22,360 |
| 9.00 | Danger Plate | 86 | Nos. | 18,060 ₹18,060 Lowest | 22,360 ₹22,360 |
| 10.00 | Phase Plate | 86 | Nos. | 19,350 ₹19,350 Lowest | 31,476 ₹31,476 |
Tender Value
₹5.7 Cr
EMD Value
₹6 L
Closing Date
28 Oct 2020, 12:00 pmClosed
Superintending Engineer
Electricity Transmission Circle Agra Kakraitha Road, Near Amar Ujala Press, Sikandara , Agra
Supply and remaining work of 132 KV Shamshabad(220)-Shamshabad(132) SC Line under ETD-III Agra
2020_UPTCL_484164_3
ET_60_ETC_A_20 21
Open Tender
Electrical Works
Lump-sum
270 days
Agra
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
EE_ETD II Agra
₹6 L
21 Nov 2020
21 Aug 2020
29 Oct 2020
21 Aug 2020
28 Oct 2020
21 Aug 2020
SUPPLY
TOWERS
Fabrication, Galvanising, Inspection & supply of 132KV DC tower including stubs, extensions & stub setting template, as per drawing & BOM.
Fabrication, Galvanising, Inspection & supply of 132KV Narrow Base / MC type Tower including stubs, extensions & stub setting template, as per drawing & BOM. The tower contains HT & MS material.
Fabrication, Galvanising, Inspection & supply ofspecial designed 220KV DC Ultra Narrow base tower having back to back (Maximum 3.8 Meter) including stubs, extensions, templates, etc. The tower contains HT & MS material.
Hot dip galvanized, Hexagon, Round hexagon head transmission towers bolts, nuts & washers for above structure as per BOM.
TOWER ACCESSORIES
Number Plate
Danger Plate
Phase Plate
Pipe type earthing material for towers
120 KN Polymer Insulators for Tension Towers
70 KV Polymer Insulators for Suspension Towers
HARDWARE SUITABLE FOR ACSR PANTHER
Double Tension Fitting
Single Tension Fitting
Single Suspension Fitting
P.A.Rod
MS Hanger
Vibration Damper
M S Joint
Repair Sleeve
EARTHWIRE ACCESSORIES SUITABLE FOR 7/10 SWG EARTHWIRE
Tension Clamp
Vibration Damper
Suspension Clamp
Copper Bond
Mid Span Joint
a) Survey including prepration of profile & schedule of materials, marking of locations (Route Length)
b) Check survey & final peg marking. (Route length)
Cost of excavation of 132KV tower / gantry foundation pits including all earth work, back filling watering and leveling.
Cost of excavation of 132KV Narrow Base MC type towers foundation pits including all earth work, back filling watering and leveling.
Setting of stubs including all foundation work but excluding cost of concreting and excavation (Rate per location) for following 132KV D/C / Narrow Base MC type towers:-
Narrow Base / MC type towers
Gantry
Cost of Concreting for all types of 132KV D/C tower Gantry foundation including cost of cement coarse sand, stone grid, dewatering, shoring and shuttering, forming, curing but excluding cost of reinforcement bars with 1:2:4 mix concrete (RCC).
Erection of super structure of 132KV DA,DB,DC towers / Gantry / Narrow Base MC type towers and their extensions including all works above ground level and fitting of danger , number & phase plate, Bird guard etc but excluding hoisting of insulator, hardware & accessories.
Laying stringing, tensioning and clamping and jointing & jumpering etc. of ACSR Panther conductor including hoisting of insulators fitting of all necessary hardware and accessories on of 132KV SC line. ( On Live Circuit i.e 01 Circuit will remain charged)
Laying stringing, tensioning and clamping and jointing & jumpering etc. of ACSR Panther conductor including hoisting of insulators fitting of all necessary hardware and accessories on of 132KV SC line.
Laying stringing, tensioning and clamping and jointing etc of 7/10 SWG earthwire including fitting of all necessary hardware and accessories on 132KV Line.
Grounding work including all earth work etc. for pipe type earthing including cost of all materials except earthing pipe.
Installation of steel reinforcement bars in RCC foundation including cost of cutting, welding, binding and placing them in foundation pits.
Umawala Engineers Pvt. Ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_756431.xls
BOQ • 0.34 MB
Tech.pdf
Tender Documents • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .