Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC PLOT NO 594 2922 GADAMAHAVIR LANE GARRAGE CHACK BHUBANESWAR 751002 | KHORDHA | ODISHA | 751002 | ₹2.8 Cr | L1 | Accepted-AOC QUALIFIED BIDDER |
| 2 | L2₹3.4 CrRejected-Finance AT PLOT NO 373 LANE NO 7 JAGANNATH VIHAR BARAMUNDA BHUBANESWAR 751003 | BHUBANESWAR | KHORDHA | ODISHA | 751003 | ₹3.4 Cr | L2 | Rejected-Finance DUE TO L2 BIDDER |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non submission of adequate turnover as per DTCN Cl. No. 12 and 110(j) and Sch G as per DTCN Cl. 12 and 110(j). |
| 4 | Rejected-Technical AT JAGANNATH NAGAR ROAD NO 11 GGP COLONY BHUBANESWAR 751025 | BHUBANESWAR | KHORDHA | ODISHA | 751025 | - | - | Rejected-Technical Non securing qualifying marks in the Point of Presentation as per DTCN Cl.110(m). |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non securing qualifying marks in the Point of Presentation as per DTCN Cl.110(m). |
Tender Value
₹3.4 Cr
EMD Value
₹3.4 L
Closing Date
11 Feb 2026, 5:00 pmClosed
CHIEF ENGINEER OPHWC
OPHWC BHUBANESWAR
Building Work
2026_OSPHW_124974_6
25/OPHWC/2025-26
National Competitive Bid
Civil Works - Buildings
365 days
Bhubaneswar
Please refer Tender documents.
3 documents required · 3 mandatory
₹11,800
₹3.4 L
Yes
24 Mar 2026
22 Jan 2026
12 Feb 2026
22 Jan 2026
11 Feb 2026
22 Jan 2026
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor
50000076 Plinth protection with side brick masonry wall (1:4) inside sand filling over which 100 mm thick cement concrete using 40 mm coarse aggregate in prop (1:3:6) and over that, 50 mm thick cement concrete using 12mm to 19mm coarse aggregate in prop (1:2:4) with cement plastering (1:4) in proper slope. Ground Floor
50000488 Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and Plinth Ground Floor
50000738 Providing and laying plain cement concrete 1:3:6 (1 cement: 3 sand: 6 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor
50000964 Providing and Fixing of Granite Flooring in floors, Treads and Landings over 25mm thick bed of cement mortar 1:1 jointed with neat cement slurry mixed with pigment to match the shades of the Granite including cleaning etc. Ground Floor
50001703 Providing and laying 60 mm thick Factory made cement concrete interlocking Paver block of M30 grade made by block making machine with strong vibratory compaction and approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coares sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-In-Charge. Ground Floor
50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. Ground Floor
50002518 Providing & Cutting bushes and leveling the grounding by back end loader (JCB), shifting the debaries 5 km from the site and as per the instruction of EIC. Ground Floor
50003689 Providing & applying Sika Cool Coat White Two Coats with Glass Fiber Cloth(single component ,Acrylic Based flexible,waterproofing,Micro fibre reinforced,heart reflecting-cum-temperature reducing coating system) @ 105kg/sqmt. After one coat of Sika cool coat primer @0.2kg/sqmt.After surface preparation means clean the existing surface with water jet,air blower etc.& a coat for Sika Raintite with cement mix slurry coat@1:1 ratio to make uneven surface to even,smooth surface,including cost conveyance,T&P,Sundries, all material labour etc.complete in all respect. Make : Sika/Fosroc/MYK . (N.S.W.I) Ground Floor
50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor
50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor
50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor
50010767 Supplying, Fitting and Fixing of 10 mm thick Digital Glazed Vitrified Tile on floor of size 600mm x 600mm of approved shade laid on 25 mm thick cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T and P etc. required for the works all complete (For new work only). [NSWI] Tile make:-NITCO/RAK/VARMORA , Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout). Ground Floor
50010813 Supplying, Fitting and Fixing Industrial Parking Vitrified Floor Tile of 10mm thick (SIZE 300X 300MM)on parking of approved shade laid on 25 mm thick cement mortar (1:1) and filling joints with epoxy grout (2mm) of approved quality including cost of all materials, labour T and P etc required for the works all complete. (For new work only) [NSWI]. Tile make:-NITCO/RAK/VARMORA , Epoxy Grout make:- ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout). Ground Floor
50010827 Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia. of 2mm thick circular pipe with Balustrade of size 38mm x 38mm x 2mm @ 900mm C/C, stainless steel square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification and the entrance newel post will be 100mm dia. of 750mm height with top bulb, buffing, polishing etc. with cost, conveyance, labour, T and P etc. required to complete in all respect. [NSWI] Stainless steel Brand:- JINDAL/NIPPON STEEL. Ground Floor
50011579 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB) Ground Floor
50011616 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING) Ground Floor
50011700 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS). Ground Floor
50013548 Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. Ground Floor
10000556 Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200cfm/300psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories,tools and plant and consumables etc for lowering of 200mm dia PVC pipes for housing fitted with socket and with or without well screen as per tenecessity for soft,medium,hard and boulder formation (PVC casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and with drawing after completion of the tube well).(Icluding both LABOUR FOR DRILLING 200MM DIA UPTO 30 MTR. & LABOUR FOR DRILLING 150MM DIA FROM 30 MTR TO 150 MTR including all.) CONSIDER FOR 150 MTR DEPTH. Ground Floor
10000564 Lowering 200mm dia. PVC pipes with or without slotted pipes as per the necessity from ground level with fitting and fixing the same in a perfectly vertical position. This includes cutting, threading pipes/slotted pipes with providing and fixing of required jointing materials, tools and plant etc. complete and keeping the top of the casing pipe threaded including plugging tube wells so as to prevent entry of foreign materials from above. (FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG). Ground Floor
10000570 Cleaning and developing 200mm dia. tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour .(FOR HAMMER DRILLING RIG/ COMBINITION DRILLING RIG). Ground Floor
10000583 Supplying and fixing of control panel board with all accessories. (UPTO 3HP SINGLE PHASE) Make: KSB Ground Floor
10000588 Supplying and fixing of HDPE Pipes 32/40 mm (High Density Polyethylene pipes having inner dia. 32mm and outer dia. 40mm) 6Kg/Sq. cm With IS specification.(32MM NOMINAL BORE SIZE). Make Finolex/Oriplast/Supreme. Ground Floor
10000594 Supplying and fixing of PVC coated steel rope including cost of material, labour etc. complete. Make-Mahdev/Aerolex Ground Floor
10000596 Supplying and fixing of Finolex/L&T/Cable 4 Sq. mm (3core copper wire flat cable with PVC insulation). Ground Floor
10000600 Supplying and fixing of accessories like Nipple, Bore cover, MS clamp, Nut Bolt, Stainless steel nipple, Short piece, GI bend, Socket etc. complete. Ground Floor
10000602 Installation charges pump set with all accessories including transportation etc. Ground Floor
10000962 Supply, fitting & fixing of 3 HP,3-Phase Submersible Pump (KSB Make, 7C/15, 80M Head ) including cost of all labour, material , transportation & excluding GST complete in all charges & installation as per direction of EIC. Ground Floor
10001184 Supplying of 200mm inner dia. PVC casing pipe for deep bore well CD (deep well casing) type basing on IS-12818-2010, wall thick ness 13mm to 14.8mm with One end of the pipe is male-threaded whereas the other end is a female-threaded socket. Threads are either V-type or trapezoid-type, and protection caps are provided on the threads to protect the threads in transit. With pressure ratings ranging from 7.5 to 20 bar (PN). Make: ORIPLAST/SUPREME/FINOLEX Ground Floor
50015838 Supply and installation of Starting Blocks stand in SS304 with FRP top 700mm height, with a base plate to be bolted on the RCC platform. Price to include 4 nos SS anchor bolts 12" ht x 1/2" dia (1 no at both ends), including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015840 Supply and installation of Lane dividers with plastic antiwave rings 150mm dia, in 2 colors for 5m each end in SS rope 50m length, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015842 Supply and installation of SS Lane tightener including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015844 Supply and installation of SS rope tightener, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015846 Supply and installation of SS anchor cup, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015848 Supply and installation of False start Indicator posts in SS 304 of 38mm dia with Rope and flag, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015850 Supply and installation of Back Stroke Indicator posts in SS 304 of 38mm dia with Rope and flag, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015852 Supply and installation of Lifeguard Chair in SS 304, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015854 Supply and installation of Divider lanes Rollers in SS 304. Each roller to take 3 nos, 50m lanes, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015856 Supply and installation of Shepard Hook with telescopic rod - 2.4m to 4.8m, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015858 Supply and installation of Lifebuoy rings for adults with 20m PP rope, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015860 Supply and installation of 2000mm dia filter in FRP complete with Laterals and inlet and outlet flange connections of 150mm with a flow rate of 125 cum /hr. (Aquafine) including labour and materials cost etc. complete. (Make- Aquafine) Ground Floor
50015862 Supply and installation of 5-valve battery in PVC of 6" dia, including pressure gauge, butterfly valves, flanges, SS nut bolt complete (Standard Brand), including labour and materials cost, etc. (Make- Aquafine) Ground Floor
50015864 Supply and installation of a Filter pump of capacity 35 LPS @ 10m head with pre-filter (3 working + 1 standby) (Kirloskar / Crompton), including labour and materials cost, etc., complete. Ground Floor
50015866 Supply and installation of Quartz sand - filter media, including 4 grades (pebbles, coarse, medium, and fine grade) 4950 kgs per filter (Standard Pebbles & Quartz Sand), including labour and materials cost, etc., complete. Ground Floor
50015868 Supply and installation of Control Panel, with Phase Indicator & Overload control, Voltage Control (Standard Brand), including labour and materials cost, etc., complete. Ground Floor
50015870 Supply and installation of Support brackets in MS, including U clips (Standard Brand), including labour and materials cost, etc., complete. Ground Floor
50015872 Supply and installation of Main Drain plate 450 x 450mm in SS304 of Nippon/Jindal made, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015874 Supply and installation of Floor filter water Inlets in ABS @ 3cum/hr, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015876 Supply and installation of Overflow grating 12" including labour and materials cost, etc. complete. (Make- Aquafine) Ground Floor
50015878 Supply and installation of Ladder for pool inn SS 304 (Jindal/Nippon) delux model 5 step including labour and materials cost, etc. complete. (Make- Aquafine) Ground Floor
50015880 Supply and installation of SS body 12V, 36W LED lights, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015882 Supply and installation of SMPS driver 230V to 12V for lights (1no for 2 lights), including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015884 Supply and installation of Panel for light Driver for lights, AC to DC current of capacity 12V, complete with MCB switch (1 switch for 2 lights), including labour and materials cost, etc. complete. (Make- Aquafine) Ground Floor
50015886 Supply and installation of Vac Head - 1 Meter (To be Operated by Rope) including labour and materials cost etc. complete. (Make- Aquafine) Ground Floor
50015888 Supply and installation of 11/2" Hose pipe 30m, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015890 Supply and installation of Self-Priming Pump, Trolley Mounted, with Starter & Cable 30m, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015892 Supply and installation of 18" Curved Brush, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015894 Supply and installation of Algea Brush 18" with Alu handdle including labour and materials cost etc. complete. (Make- Aquafine) Ground Floor
50015896 Supply and installation of Test Kit, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015898 Supply and installation of Telescopic pole 2.4m - 4.8m, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015900 Supply and installation of PP rope for the suction head, including labour and materials cost, etc., complete. (Make- Aquafine) Ground Floor
50015902 Supply and installation of all interconnecting pipes and fittings in PVC with a pressure rating of 10kg/cm2(Make: Prince / Supreme). The various pipe sizes shall be designed to achieve the velocities of flow, such as a) Return Line: 1.8 - 2.1m/sec. b) Suction Line: 1.2-1.5m/sec. c) Overflow Line: 0.6-0.8m/sec. Estimate to include the elbows, tees, and other fittings, including labour and materials cost, etc., complete for inside the pool. Ground Floor
50015904 Supply and installation of all interconnecting pipes and fittings in PVC with a pressure rating of 10kg/cm2(Make: Prince / Supreme). The various pipe sizes shall be designed to achieve the velocities of flow, such as a) Return Line: 1.8 - 2.1m/sec. b) Suction Line: 1.2-1.5m/sec. c) Overflow Line: 0.6-0.8m/sec. Estimate to include the elbows, tees, and other fittings, including labour and materials cost, etc., complete from the Pool to the plant room. Ground Floor
50015906 Supply and installation of all interconnecting pipes and fittings in PVC with a pressure rating of 10kg/cm2(Make: Prince / Supreme). The various pipe sizes shall be designed to achieve the velocities of flow, such as a) Return Line: 1.8 - 2.1m/sec. b) Suction Line: 1.2-1.5m/sec. c) Overflow Line: 0.6-0.8m/sec. Estimate to include the elbows, tees, and other fittings, including labour and materials cost, etc., complete. The work inside the plant room with the required regulation materials Ground Floor
50015908 Supply and installation of Flexible cable and conduit for lights and pumps, including labour and materials cost, etc., complete for light: 3 x 2.5 sqmm, Flexible cable. (Make: -Polycab) Ground Floor
50015910 Supply and installation of Flexible cable and conduit for lights and pumps, including labour and materials cost, etc., complete for pumps - 4 x 6 sqmm, Armoured cable. (Make: -Polycab) Ground Floor
50015912 Supplying of chemicals for commissioning Alum Rock, including labour and materials cost, etc., complete. Ground Floor
50015914 Supplying of Chemical for commissioning TCCA 90, including labour and materials cost, etc., complete. Ground Floor
50015916 Labor for Supervision, testing, commissioning, including staying, fooding, inspection, etc., complete. Ground Floor
40000946 Recessed wiring to Angle Holder Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havells/V guard/KEI) Make-switch /Angle holder-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40000949 Recessed wiring to Tube Light Point ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V one way modular switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection. ( Make of wire Finolex / Anchor / Havels/ V guard/KEI)(Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40000973 Recessed wiring to Exhaust fan Point ( MODULAR)with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS Box having front bakelight cover of suitable size, MS Box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/ceiling rose-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40000982 Point wiring for 5/ 6 amp socket outlet ( MODULAR) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 5 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40000988 Point wiring for 15/16 amp socket outlet ( MODULAR) with 4.0sq.mm FR PVC insulated single core multistrand copper conductor ISI marked in recess 20 mm dia non metalic PVC flexible conduit with 15/16 Amp, 250 V modular type switch & socket , phenolic laminated sheet suitable size ISI marked MS Box & earthing Point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc . (Make of wire Finolex / Anchor / Havels/ V guard/KEI) Make-switch/Socket-Legrand /Wipro-North West /Anchor-Panasonic/ havells)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40001000 Recessed wiring to submain in 2 x 2.5 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.2)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40001003 Recessed wiring to submain in 2 x 4 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.3)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40001006 Recessed wiring to submain in 2 x 6 sqmm FR PVC insulated single core multistarnd copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 2.5 sqmm FR PVC insulated single core multistrand copper conductor as earth wire as required (Make of wire Finolex / Anchor / Havells/ V guard/KEI) CSR SL .No- 1.8.4)(Make of PVC pipe-AKG/NORPACK) Ground Floor
40001024 Supply and laying of 6 sq.mm 2 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/ Polycab/KEI) Ground Floor
40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor
40001129 Supplying and fixing of 6"X4" 16/18 swg,2 " deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-National / Royalam) Ground Floor
40001132 Supplying and fixing of 8"X6" 16/18 swg,2 " deep G.I box of following size on surface / recesss with suitable size of 3mm thick phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required.(csr s l.no-1.24.5)(Make-(National / Royalam) Ground Floor
40001145 Supplying and fixing of 4 modular GI Box 18 swg with Modular base & cover for 4 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor
40001148 Supplying and fixing of 6 modular GI Box 18 swg with Modular base & cover for 6 module (Sl. No- 1301,1421)(Make-Legrand/Wipro/ Anchor-Panasonic/ havells) Ground Floor
40001157 Supply and Fixing of 32 amp. DPMCB – 01 no wth 32 amp. 240 volt cutout – 02 nos with copper bus bar & indicator etc.including all accessories and connections . [Make-(a) MCB/MCCB- Legrand/L &T/ABB/SCHNEIDER(b)- Voltmeter, Ammeter-AE/CAPPA (c) ALL OTHER ACCESSORIES ISI MARK] Ground Floor
40001187 Supply and fixing of 8 way , Double Door MCB Box with 1 No 32 Amp. DP MCB & 6 Nos of 20 Amp. SPMCB with sheet steel encloser , distribution board, on surface/ recess, complete with tinned copper bus bar , neutral bus bar, earth bar, din bar , detachable gland plate, interconnection , phosphate and power painted including earthing etc as required.( Sl. No- 2.3.6,2.7, )Make-MCB-(Legrand/L&T/ABB/SCHNIDER) Ground Floor
40001193 Blanking Plate(Make-Legrand /Wipro-NorthWest /Anchor-Panasonic/ havells) Ground Floor
40008124 Supply & fixing of 400mm (16") wall mounted fan with complete accessories[brown/white].including hanging and connections [MAKE- USHA MODEL-MIST AIR DUOS/ CROMPTON MODEL-TROPEDO HI SPEED//HAVELLS/V-GURAD MODEL-PETAL WF 17/ANCHOR) Ground Floor
40008126 Supply and fixing of 250 mm sweep air ventilating fan with Louvers (PVC BODY) fan with connecting wire and all accessories including fixing and connections . [MAKE- USHA MODEL-CRISP AIR VX/CROMPTON MODEL-VENTILUS/HAVELLS/ANCHOR) Ground Floor
40008291 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing) Ground Floor
40008393 Supply and fixing of 9 WT. LED Bulb installred at angle holder/ batten holder.(Make- CROMPTON/ PHILIPS(MODEL NO-AceSaver 9W)/WIPRO(MODEL NO-N09001) Ground Floor
40008397 Supply and fixing of 4 FT 20 W LED Tube light fitting with lamp including fixing and connections (Make- CROMPTON(MODEL NO-CCS-102- 20-65-SL-DP-NWH/ PHILIPS(MODEL NO-SLIMLINE NEXT 4'/ WIPRO(MODEL NO-LL20-221-XXX-65NE3) Ground Floor
MIS-CVL-5MTRWIDEVD
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000488 Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and Plinth Ground Floor
50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor
50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor
50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor
50011101 Providing and laying in position 200mm thick Tremix/VDF flooring P.C.C. M-30 grade concrete using 20mmnominal size HBG down graded chips for plain cement concrete work using cement content 400kg/cum as per approved design mix having continious agitated mixer,mis design of specified grade for reinforced cement concrete work and for VDF floorng using screed board vibrator,placing of filtermat(nylon cloth to act as very fine filter),top mat (large single PVC sheet),Vaccume process using vaccume pump about 0.08MPA which ruduces water content about 15-20% ,power trawelling,brooming,T&P Charges including power,loading,unloading and hire charges,making grooves of 6mm wide and 25mm deep @ 1.5m C/C both ways ,filling the joints with sealing compound of approved quantity"Grade-A"(Ref:DSR-SH 16.46.1) with cost of material ,labour,conveyance,royalty etc. complete basing on IS 256:2000 minimum slump is 25mm to 75mm and minimum thiockness is 125mm . Ground Floor
50011105 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using Hot applied thermoplastic compound conforming to ASTM: D36 or BS 3262 (Part-I) by fully/ semi automatic Thermoplastic paint applicator machine fitted with profile shoe, Reflectorising glass beads conforming to BS:6088 and BS 3262 (Part-1) dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour,T&P,cleaning the road surface of all dirt,seals,oil,grease and foreign material etc.complete and accordance with applicable specifications Ref: DSR-16.62.[NEW-NSWI] Ground Floor
50011883 Construction of Granular Sub-Base (Gr-IV) by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401of MoRT&H specifications for Road & Bridge Works (4th Revision). Vide AR-2006, Page-160,Item-39 . Ground Floor
50013578 Providing, Laying, spreading & compacting graded stone aggregate of to W.M.M. specifications including premixing material with water at OMC in mechanical mix plant and carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with VRR to achive the desired density as per Clause 406 of MoRT&H specifications for Road & Bridge Work (4th Revision).(AR-P-166/42). Ground Floor
MIS-CVL-BRICKMASON
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000488 Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and Plinth Ground Floor
50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor
50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor
MIS-CVL-DISMENTALI
50000082 "Dismentalling of brick/stone masonary in cement motar including stacking the useful materials for reuse and removing the debries with in 50 mtr lead. " Ground Floor
50000084 "Dismentaling of R.C.C.columns,beams,slab,staircase,landing and lintels including stacking the useful materials for reuse within 50 mtr.lead. " Ground Floor
50002518 Providing & Cutting bushes and leveling the grounding by back end loader (JCB), shifting the debaries 5 km from the site and as per the instruction of EIC. Ground Floor
50010877 Supplying, filling or Spreading of filling sand by mechanical means including cost of all labour,material T & P etc. complete as per the direction of Engineer-in-charge. Ground Floor
MIS-CVL-DRAIN
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor
50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor
50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor
50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor
MIS-CVL-INSPECTION
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000488 Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and Plinth Ground Floor
50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. Ground Floor
50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor
50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor
MIS-CVL-PUMPHOUSE
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000019 "25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. " Ground Floor
50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor
50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000023 "Priming one coat with any approved primer on new work to give an even shade including scaffolding and cleaning the surface before application etc.complete. "(FOR OUTSIDE) Ground Floor
50000025 "Wall painting two coats with plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. " Ground Floor
50000032 "12mm. thick cement plaster with cement mortar 1:4 and punning two coats and bitumen painting over top of the wall for Bearing Plaster. " Ground Floor
50000057 Drip course mould plaster 1:4 (1:cement :4sand) including necessary scaffolding curing etc. complete at all depth and height. Ground Floor
50000076 Plinth protection with side brick masonry wall (1:4) inside sand filling over which 100 mm thick cement concrete using 40 mm coarse aggregate in prop (1:3:6) and over that, 50 mm thick cement concrete using 12mm to 19mm coarse aggregate in prop (1:2:4) with cement plastering (1:4) in proper slope. Ground Floor
50000490 Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure. Ground Floor
50000742 "Painting two coats of Anti-fugal weather coat water proofing paint including scaffolding and cleaning the surface before application. " Ground Floor
50000884 "Enamel painting two coats including cost of all materials cleaning,brushes,putty etc. " Ground Floor
50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor
50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor
50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor
50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor
50010815 2.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete. Ground Floor
50011579 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC ROOF SLAB) Ground Floor
50011592 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC COLUMNS) Ground Floor
50011616 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,<(>,<)> including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR COLUMN FOOTING) Ground Floor
50011628 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work,including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR LINTEL BEAM). Ground Floor
50011640 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC CHHAJA & SHELVES). Ground Floor
50011652 "Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC STAIRCASE). Ground Floor
50011676 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability. Without cost of reinforcement(FOR RCC FLOOR BEAMS). Ground Floor
50011700 Providing and laying in position R.C.C. M-25 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix, having continuous agitated mixer, mix design of specified grade for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismentalling then after casting at all depth and height, cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability.Without cost of reinforcement (FOR RCC WALLS). Ground Floor
MIS-CVL-SEPTICTANK
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000018 "4"" thick dry brick rammed khoa well watered and fully consolidated complete,including cost of all materials as per direction of Engineer-in-charge. " Ground Floor
50000019 "25mm. thick A.S. Flooring with cement concrete 1:2:4 including punning using 12mm. size hard granite chips including cost of all materials T & P etc complete. " Ground Floor
50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000488 Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and Plinth Ground Floor
50000495 Fly Ash brick masonry in cement mortar 1:4 (1 cement:4sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75 kg per sq. cm with dimensional tolerance +/-2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure. Ground Floor
50001719 12mm thick cement plaster 1:4 overbrick work with cement punning for skirting. including cost of labour, material, T&P etc. all complete. Ground Floor
50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor
50010420 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC CHHAJA and SHELVES) Ground Floor
50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor
MIS-CVL-TOILETANDC
50000001 Earthwork in stoney earth and gravel mixed stone and boulder not exceeding 0.014 cum in volume within 50 m. initial lead and 1.5 m. initial lift including rough dressing and breaking clods to maximum 5 cm. to 7 cm. and laying in layers not exceeding 0.3 m. depth. Ground Floor
50000003 Providing and laying plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curing, shuttering etc. complete at all depth and height. Ground Floor
50000017 Supplying of filling sand in foundation and plinth including watering, ramming, consolidating and dressing, labours, tools all complete. Ground Floor
50000020 12mm thick cement plaster in cement mortar 1:6 (1cement:6sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000021 6mm thick cement plaster in cement mortar 1:4 (1 cement:4 sand) to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment with necessary scaffolding, curing etc. all complete at all depth and height for inside and outside surfaces. Ground Floor
50000022 16mm thick cement plaster in cement mortar 1:6 (1 cement:6 sand) including necessary scaffolding curing etc. all complete at all depth and height. Ground Floor
50000044 Providing anti-termite treatment including labour and materials etc complete.(As per specification confirming to IS Code 6313-3(2001)part-3 ). Ground Floor
50000488 Fly Ash brick masonry in cement mortar 1:6:(1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Foundation and Plinth Ground Floor
50000490 Fly Ash brick masonry in cement mortar 1:6 (1 cement:6 sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75kg. per sq. cm with dimensional tolerance +/- 2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure. Ground Floor
50000495 Fly Ash brick masonry in cement mortar 1:4 (1 cement:4sand) using Fly Ash bricks of 25cm x 12cm x 8cm having crushing strength not less than 75 kg per sq. cm with dimensional tolerance +/-2% including watering, curing and cost, conveyance, royalty of all materials and cost of labour etc. complete. In Superstructure. Ground Floor
50000964 Providing and Fixing of Granite Flooring in floors, Treads and Landings over 25mm thick bed of cement mortar 1:1 jointed with neat cement slurry mixed with pigment to match the shades of the Granite including cleaning etc. Ground Floor
50010360 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC ROOF SLAB) Ground Floor
50010372 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC COLUMNS) Ground Floor
50010396 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR COLUMN FOOTING) Ground Floor
50010408 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR LINTEL BEAM) Ground Floor
50010444 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR TIE BEAM) Ground Floor
50010446 Providing and laying in position R.C.C. M-20 grade concrete using 20 mm nominal size HBG down graded chips for reinforced cement concrete work using cement content as per approved design mix specified for reinforced cement concrete work, including the cost of Rigid and smooth centering and shuttering using ply, levelled works and dismantling the same after casting at all depth and height. (Excluding cost of reinforcement). (FOR RCC FLOOR BEAMS) Ground Floor
50010470 Cutting, bending, binding and placing in position of reinforcement steel for R.C.C. work including the cost of 16 S.W.G. binding wire, steel, labour tools etc. Steel Brand:-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER)/Shyam Steel. Ground Floor
50010554 Providing, supplying and fixing of UPVC Glazed Fixed Louvered Ventilator of size 600 mm X600 mm made out of multi chambered UPVC of DUROPLAST / SIMTA ASTRIX / NCL VEKA having isolated drainage, holes about 8 mm dia. to be provided @ 300 mm C/C outer side of lower sashes and reinforced with Galvanized Iron profiles throughout the window with Fan(185mm)of USHA / CROMPTON/Havells/Anchor. The outer frame having an overall size of 39 mm x 39 mm x 2.2 mm thickness with reinforcement of 1.2 mm . Ventilator shall be provided with 4 mm Pin Head glass, standard hardware. Wall thickness of frame and Mullion shall be 2.4 mm, including cost and conveyance of all materials, accessories, labour charges for transportation, erection at site complete for finished item of work with transportation and wastage. Ground Floor
50010572 Providing and Priming one coat of approved wall primer over interior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Interior cement based wall primer of premium quality.Interior Primer :- ASIAN PAINTS(Trucare interior-WT)/ BERGER (BP White Primer)/DULUX(Professional interior sealer-A500) Ground Floor
50010584 Providing and Priming one coat of approved wall primer over exterior work to give an even shade including scaffolding and cleaning the surface before application etc. complete. Exterior cement based wall primer of premium quality Exterior Primer :- ASIAN PAINTS (Trucare exterior-WT)/ BERGER (Walmasta Primer)/DULUX (Professional exterior sealer-E900) Ground Floor
50010596 Providing and Painting two coats of Anti-fungal weather coat, water proofing paint including scaffolding and cleaning the surface before application. [NSWI] Weather Coat :- ASIAN PAINTS (ULTIMA PROTEK) / BURGER (LONG LIFE-7 FLEXO) / and DULUX (PROFESSIONAL WEATHER SHIELD ELASTOMERIC). Ground Floor
50010608 Providing and painting two coats of plastic emulsion paint of approved shade including scaffolding and cleaning the surface before application. [NSWI] Plastic Emulsion Paint :- ASIAN (Premium Emulsion)/BURGER (Easy Clean)/DULUX (Super Clean). Ground Floor
50010620 Providing and Finishing wall surface with Acrylic Interior wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging charges with cost of all materials, labour T and P etc. complete. [NSWI] INTERIOR ACRYLIC WALL PUTTY:- (BIRLA WHITE/JK WALL PUTTY) Ground Floor
50010644 Providing and painting two coats of Enamel paint over wood/Iron surfaces including cost of all materials,labour, cleaning, brushes, putty etc. Enamel paint :- Asian (AP Apcolite Gloss Enamel PO RED/Berger (Luxol HI Gloss Enamel PO RED)/Dulux(Gloss Premium Enamel). Ground Floor
50010656 Providing and Priming one coat of primer over new wood/Iron work including cost of all materials,labour,cleaning, brushes, putty etc. Wood/Iron Primer brand:- ASIAN PAINTS (Trucare wood primer pink)/BERGER (Parrot wood primer pink)/DULUX(Dulux wood pink) Ground Floor
50010668 Providing and Fixing of Factory made WPC Door Frame of size 125x65 provided with plug-in socket arrangement and joined together by screws. The finished door frame units to be of approved colour using high quality pigments complete in all respect as per specification. [NSWI] WPC Frame make:-Century/Green Ground Floor
50010704 Providing and Fixing of Single leaf solid WPC door shutter of 30 mm thick compacted with wood grain finished with 2 Nos SS Handles (150 mm), 2 Nos SS Tower Bolt (250mm x 10mm), 4 Nos. SS Butt Hinges (125mm x 8.5mm x 5.5mm ) with all necessary fittings Complete with approved colour . [NSWI]Make:- WPC Door(Century/Green), Hard ware fittings (Godrej). Ground Floor
50010716 Supplying, fitting and fixing of MS. grill,MS louvred ventiletors (make-SAIL/VIZAG/TATA TISCON/RINL/JINDAL STEEL(PANTHER))including cost of labour ,material, transportation etc. as per the specification provided in Drawing. Ground Floor
50010741 Providing, Fixing and Fitting Ceramic glazed tiles on wall of size 300mmx450mm of approved shade on 12mm thick cement mortar of mix (1:3) and grouted with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties of all Materials, cost of all Labour, Sundries, T and P required for the work, etc. complete in all respect. [NSWI] Tile make:-VARMORA/ NITCO / RAK Ground Floor
50010753 Providing, Fixing and Fitting Anti-skid vitrified floor tiles of size 300mm x 300mmx9mm laid over 25mm thick Cement mortar (1:1) laid in proper slope and filling joints with epoxy grout including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T and P required for the work, etc. complete in all respect. [NSWI] Tile make:-NITCO/RAK/VARMORA , Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout). Ground Floor
50010767 Supplying, Fitting and Fixing of 10 mm thick Digital Glazed Vitrified Tile on floor of size 600mm x 600mm of approved shade laid on 25 mm thick cement mortar (1:1) and filling joints with epoxy grout of approved quality including cost of all materials, labour T and P etc. required for the works all complete (For new work only). [NSWI] Tile make:-NITCO/RAK/VARMORA , Epoxy Grout make: ASIAN PAINTS(code9660)/ BERGER (HS Tile grout)/DULUX (epoxy grout). Ground Floor
50010815 2.5cm thick grading concrete (1:2:2) on roof slab with 6mm of size hard granite chips with chicken welded mesh 25mmx25mm 11 gauge on new work including cost of labour, material, T and P etc. all complete. Ground Floor
MIS-INE-AREAILLUMI
40001027 Supply and laying of 10 sq.mm 2 core PVC Al. Arm Cableof 1.1 KV grade ISI Marked direct in ground including excavation , sand cushioning , protective covering and refilling the trench etc. as required. ( sl no- 5.1.1)(Make Cable- Finolex/ Havells/ Polycab/KEI) Ground Floor
40001126 providing and fixing 8 SWG(4mm)dia copper wire on surface or in recess for loop earthing as required (sl no-3.18) Ground Floor
40001319 Supply and fixing of 4sqmm service wire along with G.I wire for support of service wire including all acessories and connections from each quaters to energy meter(Make-Joshi/Multicab) Ground Floor
40002124 Supply & fixing of outdoor/indoor type 63A DPMCB panel having I/C-63 A DPMCB-01 No & 63 Amp 2P Change Over/rotary switch ,Outgoing -02 Nos 32 Amp DPMCB & 02 nos 32 A DP switch with powder coating all accessories & connectionMake a)MCB/MCCB-legrand/schnider/abb/,L&T/Anchor/Panasonic (b)Voltmeter/Ametre-AE/CAPPA Ground Floor
40002353 Supply and fixing of 1mtr. Long Galvanized deocartive single arm welded with top canopy at an angle of 120 degree with the pole.The outer dia of arms are 46mm,4 nutbolts suitable for 70mm Top. Ground Floor
40002355 Supply and fixing of 1mtr. Long Galvanized deocartive double arm welded with top canopy at an angle of 120 degree with the pole.The outer dia of arms are 46mm,4 nutbolts suitable for 70mm Top. Ground Floor
40003041 Supply, installation, testing and commissioning of GI coil earthing including excavation of earth pit in all kinds of soil/rock filling with charcoal & salt, connections to earthing stids/ bolt of the pole complete including all accesories and connections. Ground Floor
40008291 Supply and fixing of Earthing with GI earth pipe 3 meter long 40 mm dia Heavy Duty TATA make including accessories and providing masonary enclosure with cover plate having locking arrangement and water pipe etc with charcoal and salt as required.(Minimum 1.5 mtr distance from building & 3 mtr distance from earthing to earthing) Ground Floor
40008405 Supply & fixing of 90 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 having LM 79 LM 80 tested including bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire with all accessories . (Make- CROMPTON(MODEL NO-TRP-412-90-57-SL-LM-NSG)/PHILIPS(MODEL NO-BRP033 LED90S 90W 9000LM)/WIPRO(MODEL NO-LR08-102-XXX-57-XX ) Ground Floor
MIS-IPH-TOILET
10001056 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 mtr. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 20 mm outer dia CPVC pipes. Ground Floor
10001058 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 25 mm outer dia CPVC pipes. Ground Floor
10001060 Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS:15778,having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints should be at 430 Kg/Sq.Cm/1hr at 20 degree Centigrade complete. Make: ORIPLAST/SUPREME/FINOLEX (All SDR-13.5). 40 mm outer dia CPVC pipes. Ground Floor
10001064 Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method; water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid for separately). 110mm dia. SWR pipe of Single Socket Push fit of class-3 (6Kg/Sq.cm). Make:- ORIPLAST/SUPREME/FINOLEX. 110mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm). Ground Floor
10001066 Laying in trenches/fixing on walls UPVC pipes IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by push fit method with water tightness joint test 0.5Kg/sq.cm/15min as per specification complete. (Earth work in trenches to be measured and paid separately). 160mm dia. rigid UPVC SWR pipe Class- 3 (6Kg/Sq.cm). Make: ORIPLAST/SUPREME/FINOLEX. 160mm dia. UPVC pipe, Class-3 (6Kg/Sq.cm). Ground Floor
10001068 Providing and fixing on wall face PVC 110 mm dia. offset SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. offset PVC SWR type. Ground Floor
10001072 Providing and fixing on wall face 110mm dia. plain bend PVC SWR type moulded fittings / accessories for Rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Plain Bend PVC SWR type. Ground Floor
10001074 Providing and fixing on wall face 110mm dia. bend with door PVC SWR type moulded fittings / accessories for rigid UPVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. Bend with door PVC SWR type. Ground Floor
10001076 Providing and fixing on wall face 110 mm dia. cowel PVC SWR moulded fittings / accessories for PVC SWR pipes conforming to IS: 13592 Type B, including jointing with seal ring leaving 10 mm gap for thermal expansion. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. cowel PVC SWR type. Ground Floor
10001084 Providing and fixing 110 mm dia. PVC SWR P-Trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. Make: ORIPLAST/SUPREME/FINOLEX. 110 mm dia. P - trap PVC SWR type. Ground Floor
10001088 Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc. all complete as per specification with 1:4 brick work in cement mortar (1:4) and 12mm thick cement plaster. For 250mm thick wall. Ground Floor
10001094 Cutting holes in R.C.C floor and roofs up to 19cm thick for passing G.I/PVC pipes and fittings etc. and repairing the hole after insertion of pipes etc. with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm X 15cm X 25cm. Ground Floor
10001096 Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete, with cement concrete (1:3:6) and 12mm cement plaster (1:3) along with Cement punning. Ground Floor
10001106 Providing and fixing EWC with P-trap (180mm) Floor Mounted With PP soft close seat cover, hinges, dual flush cistern fitting, fixing of accessories set. Size: 410mmx660mmx810mm conforming to IS 2556: Part 8-2004, to the floor with rawl plug and chromium plated screws including jointing the trap with UPVC S.W.R pipe of Type B in white cement etc. all complete as per specification. (With Seat and cover). Make: JAQUAR(CNS-WHT-751P180SPPZ)/ KOHLER(K-2983IN-S-O) Floor Mounted with Cistern. Ground Floor
10001116 Providing and Fixing PVC LOW LEVEL CYSTERN conforming to IS 2556 : Part 3- 2004 SIZE 415X130X305mm.Make: Hindware SUPERB (CAT NO-50 8829)/Parryware SLIMLINE ECONOMY (E-8090).White Vitreous china 10 litre (full flush) capacity manually controlled low level flushing cistern with all fittings and fixtures. Ground Floor
10001122 Providing and fixing of Standing urinal including connecting the urinal with 32mm dia. PVC waste pipe by means of white lead mixed with chopped hemp,15mm dia. PVC Reinforced heavy duty connection pipe etc. all complete as per specification. (White vitreous china clay half stall urinal flat back size-355X345X535 mm. Make: JAQUAR(URS-WHT-13261). Standing Urinal 355x345x535mm. Ground Floor
10001124 Providing and fixing of 25mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 25 mm dia. CPVC Full Way Valve / Ball Valve. Ground Floor
10001126 Providing and fixing of 40mm dia. CPVC Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specif ication complete . Make: ORIPLAST/SUPREME/FINOLEX. 40 mm dia. CPVC Full Way Valve / Ball Valve. Ground Floor
10001132 Providing and fixing of 15mm dia. CP Screw-down two way Bib Cocks (Taps)polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux headand high quality). Make: JAQUAR( CON-041KN)/ KOHLER (K-25432IN-4-CP). 15mm dia. Two-way Short body bib cock. Ground Floor
10001134 Providing and fixing of 15mm CP dia. Screw-down long body Bib Cocks (Taps) polished bright with CP flange and CP extension piece of the following nominal sizes as per specification complete. (Delux Headand high quality). Make: JAQUAR( CON-107KN)/ KOHLER (K-27490IN-CP) 15mm dia. Long body bib cock. Ground Floor
10001136 Providing and fixing of 15mm dia. CP Screw-down angle Stop Cocks with flange of the following nominal sizes as per specification complete. (Deluxe Head and high quality). Make: JAQUAR (CON-059KN))/ KOHLER (K-11568IN-7B-CP). 15mm diameter Angle Stop Cock. Ground Floor
10001148 Providing and fixing Stainless Steel soap dish holder fixed to head less socket caps, wall plugs with CP brass screws as per specification. Make: JAQUAR (ACN-1131N))/KOHLER (K-10712D-CP). Stainless Steel Soap Dish Holder. Ground Floor
10001150 Providing and fixing of 600x120 mm glass Shelf with anodised aluminium angle frame with chromium plated brassbrackets and guard rails of required size complete, fixed to head less socket caps, wall plugs with chromium plated brass screws as per specification. Size 600x120 mm glass shelf. Make: AQUAR-(ACN-1171N)/ KOHLER(K5636IN-CP). 600mmX120mm Glass Self. Ground Floor
10001152 Providing and fixing standard sized stainless steel towel rail of 600mm long complete with Chromium Plated brass brackets; fixed to head less socket caps, wall plugs with Chromium Plated brass screws, complete as per specification. (Make: JAQUAR (ACN-1111SM)/ KOHLER (K-5630IN-CP),(Heavy quality). 25 x 600 mm long SS Towel Rail. Ground Floor
10001158 Providing and fixing 600 mm x 450 mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to head less socket caps, wall plugs and washers complete as per specification.(AR-2013,SL. NO.-3.4.26). Make: Mirror Glass (SAINT GOBIN/AIS(ASAHI)). 600mm x450mm Bevelled Edge Mirror (Heavy quality). Ground Floor
10001160 Providing and fixing Rotational moulded polyethylene cylindrical vertical water storage tank 3layer wall conforming to IS : 12701--1996 including cutting holes through the tank and fixing, fittings CPVC tubes and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting up to a height of 5 metres above ground level and placing the tank to the required position etc. all complete as per specification. Make: SINTEX/SUPREME/ORIPLAST. Triple Layer Cylindrical Vertical water storage tanks. Ground Floor
10001166 Fixing wash basins WITHOUT PEDESTALwith hole for pillar taps with 10mm dia M S rack bolt (JAQUAR MAKE) painted white including cutting holes in walls and making good the damages etc all complete, with fixing of 15mm dia pillar cock, as per specification.(Vitreous china flat back wash basin 550x400x200 mm)(CODE CNS-WHT-801 JAQUAR MAKE).Pillar cock(CON-021 JAQUAR)32mm full/half thread CP waste(ALD-705/709-JAQUAR), Rack bolt(ZPS-MST-RB03)Vitreous china flat back wash basin 550x400x200mm . Ground Floor
10001209 Providing and fixing curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish size H:900XW:450mm with stainless Steel brackets including cutting holes in wall and making good the damages etc. complete as per specification. Make: JAQUAR (JSE-CHR-110UC450X/110US450X). Curved/Rectangular shaped urinal partition with 10mm thick frosted glass chrome finish. Ground Floor
a) APPROVED MAKE /BRAND FOR CEMENT : ULTRATECH, NUVOCO, ACC, JSW (PSC),RAMCO(PSC),DALMIA(PSC),SAGAR(PSC)
APPROVED MAKE / BRANDS ARE TO BE UTILISED STRICTLY DURING EXECUTION OF ABOVE RELATED ITEMS OF WORK
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
DTCN6.pdf
Tender Documents • 1.38 MB
BOQ_577440.xls
BOQ • 0.74 MB
swimmingpool.pdf