Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹7.8 L+₹41,394 (5.64%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹9.9 L+₹2.5 L (34.6%)Rejected-AOC | L3 | Rejected-AOC L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
21 Apr 2022, 6:00 pmClosed
GE AF Amla
GE AF Amla, Betul Dist 460553 (MP)
UPKEEPING OF PUMP HOUSE FILTRATION AND BOREWELLS OF WATER SUPPLY INSTALLATION AT AFS AMLA
2022_MES_512654_2
8455/E8 of 2021-2022
Open Tender
Civil Works
Item Rate
GE AF Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹20,000
Yes
5 Jul 2022
31 Mar 2022
28 Apr 2022
31 Mar 2022
21 Apr 2022
7 Apr 2022
Amount
S&F in repair Aviation obstruction light on approx 80ft staging overhead water tank with all mounting arrangements, cementing etc., having LED 2 X 100W capacity in yellow painted die cast aluminium alloy housing red colour polycarbonate dome and accessories complete all as specified and directed.
Demolition brickwork built in cement mortar as in valve chambers including demolition of PCC coping and disposal of debris of the premises complete all as directed.
M&L for brickwork wih old sub-class 'B' bricks with straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified except bricks.
M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including necessary form work etc, complete all as specified & directed.
M&L for rendering 15 mm thick Cement Mortar 1:4 over brick or concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed.
Supply and fix in repairs cast iron foot valve ball type with synthetic nitrile rubber coated ball and seat ring, cast iron strainer flanged/ screwed at the end of the suction line including provision of nut, bolt, rubber gasket, washer etc., and taking down old unserviceable foot valve from UG sump complete suitable for the following sizes of pipes:- Note:- The rate quoted by contractor deemed to be inclusive of welding work if any required at site while fixing foot valve.
80 mm dia bore
100 mm dia bore
150 mm dia bore
S&F repairs LED flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 80 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed.
S&F repairs LED Flood light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 120 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed.
S&F repairs LED street light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 40 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including fixing on pole with suitable MS flat iron braket or GI pipe in angle complete all as specified and directed.
M & L for painting of Steel tubular poles 8.5 m to 9 m height of any size with two coats of aluminum paint including painting to cross arms and clamps etc including preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing complete all as specified and directed.
Supply and fix in repairs display board with dimension 1.5 m x 1.0 m X 0.3 m made up of wood/ plywood of thickness minimum 25 mm on all sides except front side. Front side shall be provided with sliding window openable type using plain glass of size 5 mm thick with aluminium guiding channel, roller clamp, handle knob etc., including fixing to wall with nut, screw fasteners complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for providing dry river sand as in sand cusioning for underground cable protection including punning down sand in layers complete all as specified & directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
M&L road cutting of size 30 cm width x 45 cm depth for laying of cables incl making good the road with necessary returning filling, ramming and bituminous portion shall be filled with PCC 1:2:4, type B2 for minimum 15 cm thick from top and matching the surfaces with existing complete all as specified and directed.
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables including taking down old U/s pipe complete all as specified and directed
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor, stranded, armoured, PVC sheathed, LT 1100-volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for the following sizes of cable:- Note :- (i) Earth work excavation, returning filling and disposal shall be measured & paid separately under respective items. (ii) The surface disturbed during dismantling/demolition shall be made good by contractor at his own cost by using 1:2:4 type B1 concrete (or) in CM 1:4 which deemed to be included in the contractor quoted rate.
25 sqmm, 3.5 core
16 sqmm, 4 core
16 sqmm, 2 core
10 sqmm, 2 core
M & L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.15mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to & including GI earth strip 25 x 4mm as earthing lead by means of bolts, nuts, and washers of galvanised iron or steel all as shown in electrical plate no. 3 of SSR Part I, connected to main switch board and testing on completion with and including necessary earth work in any strata, filling the pit with charcoal and common salt surrounding the earth plate , watering arrangements with 20 mm dia light grade GI pipe, GI funnel with wire mesh, PCC chamber with M-10 using 40mm graded stone aggregates with RCC cover, 550 x 550 x 50mm thick, with type B1, reinforced with 10mm CTD bars @ 150mm c/c, both ways with 2 nos drop handles of 10mm dia round bars 400m long, 40mm bore, medium grade GI pipe for earth lead protection pipe up to test point complete all as specified and directed. Note :- (i) Earthing resistance required in earthing shall less than 1.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engg-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision. (ii) Quoted rates shall be deemed to be included for earth strip with protection pipe up to 7.5 length.
S&F in repairs thermo plastic cable looping boxes, factory made, IP 66 sheet of size 210 x 155 x 92 mm with separate detached gland plate, including MCB TPN 20 A & bakelite connector 4-way 20 Amp with din rail, weather vermin proof front door opening with hinge and locking arrangement, fixed to pole all as specified and directed.
M&L in repair for wiring from junction box to street light fittings with approved colour coding as per IS with single core PVC insulated but unsheathed FR cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through through heavy duty ISI marked surface mounted ERW stove enamelled, steel conduit of size 20mm dia fixed on pole using clamps, including bends and elbows, couplers, bell mouth reducer, junction box all as per relevant IS all as specified complete for the following size:-
2 runs of 1.5 Sqmm size main cable and one run of 1.5 Sqmm size earth continuity conductor.
Supply and install wall mounted type First Aid Box of size 30cm x 30cm x 10cm with four shelf and front transparent acrylic glass door, including lock arrangement, made from high grade metal with powder coating for anti-rust proof long life, equipped with all medicines and equipments as required for first aid complete all as specified and all as directed.
M & L for scrapping down rusted, fallen paint from the Electrical LT Motor pannel of size approx.185cm x185cm x50 cm situated at pump house Area including rail/channel of base using mechanical scrapers, brushes, sand paper etc and removing the old paint to the complete outer surfaces and repainting external surfaces with black/yellow (strip) colour with applying a coat of red oxide zinc chrome primer on the both internal & external portion where base metal is exposed, painting spray one coat of synthetic enamel paint for indoor type panel including starter/ MCCB's specific cabinet complete all as specified all directed.
S&F in repairs MCCB, 3 pole of current rating 125 Amps thermal release and rupturing capacity 16 KA all as specified and directed.
S&F in repairs power contactor 70 - 100 Amps, 3 pole (1No + 1NC) with voltage 415 Volts AC and necessary auxiliary accessories all as per manufacturer complete all as specified and directed.
S&F in repairs Isolator TPN 40A 415 Volt all as specified and directed.
S & F in repairs Single phase preventer suitable for existing pannel
Dismantling of steel tubular\ RCC poles 9 mtrs long including demolition of PCC and necessary earth work and keeping in safe custody for reuse or for issue under schedule of credit.
Supply & install of steel tubular swaged poles complete with cast iron base plate 6mm thick of size 450mm x 450mm finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long) pole made out of ERW MS tubing confirming to IS 2713 / IS 1161 Part II including drilling of holes of required size and no’s for fixing of cross arms bracing support/ taking out of cables etc., and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embedded in concrete after taking down old one complete all as specified and as directed. Note: Excavation of earthwork, PCC concrete bed etc. will be measured & paid separately.
S&F in repairs Post of lantern light fittings with surge protector & Die cast aluminium housing with IP65 protection with LED as symmetric for 10 watt inclusive of LED lamp & suitable capacity of control gear box/driver and suitable flexible wiring with 0.5 sq mm PVC insulated copper cable through and including PCC block,Connector as stand necessary excavation , MS flat iron braket complete all as specified and directed.
M&L for fabric glow sign board both facing outdoor type with aluminium frame 2 mm thick of size 1.2 mtr X 0.75 mtr X 0.23 mtr with necessary cleats including two LED tube light fitting 20 watt and writing letters of figures approximate 80 No's ( Block , Roman , Italic or Indian ) n exc 20 Cm fixed on suitable number ofsteel angle/channel upto height 1.5meter with pcc block for grouting complete all as specified & directed .
M&L for fabric glow sign board both facing outdoor type with aluminium frame 2 mm thick of size 6 mtr X 0.5 mtr X 0.23 mtr with necessary cleats including four LED tube light fitting 20 watt and writing letters of figures approximate 100 No's ( Block , Roman , Italic or Indian ) n exc 50 Cm including fixing on existing steel structure/wall with necessary welding ,cutting grouting complete all as specified & directed .
S&F in repairs 50mm size cast iron Air Release Valve, flange ended, double orifice type with inbuilt isolating sluice valve suitable for pressure rating PN 1.6 Mpa, conform to IS: 14845 complete with all accessories including taking down old ARV all as specified and directed.
Supply , installing and testing of LT panel board indoor type, weather and vermin proof, having dimension minimum 1.8mX 2.5mX0.5m factory fabricated, cubical type, made out of CRCA sheet 02 mm thick suitable for 415 volt, 3 phase, 4 wire system with front openable each compartment and locking arrangement with PVC star screwing hinged arrangement, epoxy power coated , internal wiring complete with copper conductor cable for metering system and CT's complete including taking down old panel all as specified, comprising by providing of the following equipments /fitments complete:- a) DOL starter 5 HP- 5 No b) Star Delta starter Suitable for 45HP VT pump -3NOS c) Star Delta starter Suitable for Upto 12.5HP Submesible Pump -1NO d) Onload Manual Changeover switch 4 pole ,415 Volts,250 amps e) MCCB, 4pole , 415 Volts of current rating 250 Amps, thermal magnetic release rupturing capacity 25 KA- 01 No(For incoming) f) MCCB, 4pole , 415 Volts of current rating 100 Amps, thermal magnetic release rupturing capacity 16 KA- 01 No(for Street Light) g) MCCB, 3 pole of current rating 125 Amps thermal release and rupturing capacity 16 KA -03 Nos(for 03Nos VTpump Starter) h) MCB TPN 32 Amps -02 No j) MCB SPN 40 Amps -03 No k) Internal Control Wiring with PVC insulated copper conductor multi standard appropriate guage including all coper lugs,CTs and connection incoming/outgoing cable with lugs and cable glands ,connector etc. l) Digital Voltmeter digital (0-500Volt) m) Digital Ammeter(0-100Amps) n) Indicator Lamp LED type for incoming and pump/motor -10 Nos o) Start & Stop Push Button - 09 Nos p)Single phase preventor - 09 No q) Aluminium busbar suitable for three phase four wire system of current rating 600 Amps covered with coloured PVC sleeves as per colour code mounted on DMC insulators -01set
M&L for Rubber insulating mating of size 2 Mtr X 01 mtr X 10 mm thick as per IS all as per specified and directed.
M&L for Rubber insulating mating of size 2 Mtr X 01 mtr X 15 mm thick as per IS all as per specified and directed.
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Shri Sai Enterprises
M/s Vinod Yadav
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .