Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | ₹8.2 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹8.2 LRejected-Finance | ₹8.2 L | L2 | Rejected-Finance quoting higher rate |
| 3 | L3₹9.3 LRejected-Finance | ₹9.3 L | L3 | Rejected-Finance quoting higher rate |
| 4 | L4₹10.0 LRejected-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | ₹10.0 L | L4 | Rejected-Finance quoting higher rate |
| 5 | L5₹11.3 LRejected-Finance | ₹11.3 L | L5 | Rejected-Finance quoting higher rate |
| Sl No | Description | Qty | Unit | HIMAYAN L5 | Scientific Refrigeration L2 | M.S. COOLING & ENGINEERING CO. L3 | Shinryo Suvidha Engineers India Pvt. Ltd. L4 | P. M. COOLING AND ENGINEERING CO L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery of Inverter type split Air-conditioner machine of Cooling Capacity- 6.5 kW (Minimum), 3/4 star rated, noise level not more than 51 db. This Split Air Conditioning machine should be fitted with Rotary/Scroll compressors, LCD remote & all other accessories suitable for Refrigerant- R32 having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (Make:- Mitsubishi Heavy Industries SRK24YYM-W6/ Mitsubishi Electric RJS22VF/O-General ASGG24CPAB-B (R-32) as approved by EIC) | 8 | nos | 78,000 ₹6.2 L | 59,400 ₹4.8 L | 61,500 ₹4.9 L | 62,000 ₹5.0 L | 68,225 ₹5.5 L |
| 2.00 | Supply & delivery of Inverter type split Air-conditioner machine of Cooling Capacity- 5.0 kW (Minimum), 3 star rated, noise level not more than 51 db. This Split Air Conditioning machineshould be fitted with Rotary/Scroll compressor, LCD remote & all other accessories suitable for Refrigerant- R32,having both condenser and cooling coils made of copper tube connecting chord with plug top of suitable capacity with indicator(brand approved by EIC) confirming to lS 1391 ( Part - I & Part - ll) with all amendments. (Mitsubishi Heavy Industries SRK 18YXP-W6/Mitsubishi Electric RJS 18VF/O-General ASGG18CPAB-B (R-32) as approved by EIC ) | 2 | nos | 65,000 ₹1.3 L | 48,900 ₹97,800 | 52,500 ₹1.1 L | 55,000 ₹1.1 L | 59,860 ₹1.2 L |
| 3.00 | Supply & delivery of inverter type split Air-conditioner machine of Cooling Capacity- 3.4 kW (Minimum), 3-star rated. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32, having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (O-General ASGG12CPAB-B(R32)/Mitsubishi Heavy Industries SRK 13YXP-W6/Mitsubishi Electric RJS 13VF as per approved by EIC) | 2 | nos | 60,000 ₹1.2 L | 38,900 ₹77,800 | 42,500 ₹85,000 | 45,000 ₹90,000 | 45,650 ₹91,300 |
| 4.00 | Installation, testing & commissioning of the above-said split ACs on wall with appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. | 16 | item | 2,000 ₹32,000 | 1,500 ₹24,000 | 1,750 ₹28,000 | 2,200 ₹35,200 | 1,500 ₹24,000 |
| 5.00SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleevessections of specified thickness as given below for suction andliquid lines, all accessories as per specification etc. as required. | ||||||||
| 5.01 | a) 5/8" (15.88 mm.) (for suction) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC) | 150 | Mtrs | 475 ₹71,250 | 410 ₹61,500 | 550 ₹82,500 | 650 ₹97,500 | 5 ₹750 |
| 5.02 | b) 1/4" (6.4 mm) ( for discharge) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC) | 150 | Mtrs | 240 ₹36,000 | 172 ₹25,800 | 350 ₹52,500 | 450 ₹67,500 | 5 ₹750 |
| 6.00 | Supply & Laying of 3 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.I.C) | 150 | Mtr | 165 ₹24,750 | 105 ₹15,750 | 150 ₹22,500 | 200 ₹30,000 | 5 ₹750 |
| 7.00 | Supply and laying 25mm PVC pipe (heavy type) for water drainage.(25mmOD, 1mm thick) with 6mm nitrile rubber insulation with proper support & bracket as per direction. (Make- Supreme/Oriplast). | 150 | Mtr | 220 ₹33,000 | 90 ₹13,500 | 85 ₹12,750 | 150 ₹22,500 | 5 ₹750 |
| 8.00 | Supply & fixing required necesssary arrangement of wooden frame made of ply of thickness- 19mm for fixing the AC machines incl. mending good the damages as per direction of E.I.C. | 12 | Job | 950 ₹11,400 | 1,200 ₹14,400 | 2,650 ₹31,800 | 2,800 ₹33,600 | 1,500 ₹18,000 |
Tender Value
Refer Docs
EMD Value
₹16,466
Closing Date
15 Dec 2025, 1:00 pmClosed
The Executive Engineer PWD,ECD
New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Construction of G V storied Modern Fire Station Building within the existing Tollygunge fire Station SITC of Air Conditioning System
2025_WBPWD_951773_1
WBPWD/EE-ECD/e-NIQ-39/2025-26
Open Tender
ELECTRICAL WORKS ORG
15 days
Tollygunge
please refer tender documents
5 documents required · 5 mandatory
₹16,466
O/O The Executive Engineer PWD ECD
17 Feb 2026
17 Nov 2025
17 Dec 2025
17 Nov 2025
15 Dec 2025
26 Nov 2025
17 Nov 2025 - 24 Nov 2025
24 Nov 2025
Amount
Supply & delivery of Inverter type split Air-conditioner machine of Cooling Capacity- 6.5 kW (Minimum), 3/4 star rated, noise level not more than 51 db. This Split Air Conditioning machine should be fitted with Rotary/Scroll compressors, LCD remote & all other accessories suitable for Refrigerant- R32 having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (Make:- Mitsubishi Heavy Industries SRK24YYM-W6/ Mitsubishi Electric RJS22VF/O-General ASGG24CPAB-B (R-32) as approved by EIC)
Supply & delivery of Inverter type split Air-conditioner machine of Cooling Capacity- 5.0 kW (Minimum), 3 star rated, noise level not more than 51 db. This Split Air Conditioning machineshould be fitted with Rotary/Scroll compressor, LCD remote & all other accessories suitable for Refrigerant- R32,having both condenser and cooling coils made of copper tube connecting chord with plug top of suitable capacity with indicator(brand approved by EIC) confirming to lS 1391 ( Part - I & Part - ll) with all amendments. (Mitsubishi Heavy Industries SRK 18YXP-W6/Mitsubishi Electric RJS 18VF/O-General ASGG18CPAB-B (R-32) as approved by EIC )
Supply & delivery of inverter type split Air-conditioner machine of Cooling Capacity- 3.4 kW (Minimum), 3-star rated. This Split Air Conditioning machine should be fitted with Rotary compressors, LCD remote & all other accessories suitable for Refrigerant- R32, having both condenser & cooling coil made of copper tube, connecting cord with plug top of suitable capacity with indicator(brand approved by E.I.C) conforming to IS:-1391(Part-I & Part- II) with all ammendments. (O-General ASGG12CPAB-B(R32)/Mitsubishi Heavy Industries SRK 13YXP-W6/Mitsubishi Electric RJS 13VF as per approved by EIC)
Installation, testing & commissioning of the above-said split ACs on wall with appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class -O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleevessections of specified thickness as given below for suction andliquid lines, all accessories as per specification etc. as required.
a) 5/8" (15.88 mm.) (for suction) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
b) 1/4" (6.4 mm) ( for discharge) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19mm thick insulation. (Make- Approved by EIC)
Supply & Laying of 3 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection between Indoor to Outdoor unit of Split type AC m/c (Polycab/Gloster/Finolex/Havells /RR Kabel as approved by E.I.C)
Supply and laying 25mm PVC pipe (heavy type) for water drainage.(25mmOD, 1mm thick) with 6mm nitrile rubber insulation with proper support & bracket as per direction. (Make- Supreme/Oriplast).
Supply & fixing required necesssary arrangement of wooden frame made of ply of thickness- 19mm for fixing the AC machines incl. mending good the damages as per direction of E.I.C.
Dismantling existing 4 nos Split type AC machines etc with owns tools & takles and with owns tools & takles incl. mending good damages and deposited the site as directed by EIC.
Supply & filling/poring rerigerant R410/R32 refrigerant gas for AC machines incl. testing and commissioning of complete machines with all indoors, outdoor units, electrical, remotes incl. pressure testing with nitrogen and vaccumiazation
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for installation, per storey of building per vertical run.
Scientific Refrigeration (BID ID -7644388)
M.S. COOLING & ENGINEERING CO. (BID ID -7644390)
Shinryo Suvidha Engineers India Pvt. Ltd. (BID ID -7644752)
HIMAYAN (BID ID -7617167)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.23 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2275522.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid