| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.4 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹24.0 L+₹1.1 L (4.85%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹25.8 L+₹2.9 L (12.6%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹26.3 L+₹3.5 L (15.2%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹27.0 L+₹4.2 L (18.2%)Rejected-Finance HOUSE NO 165 A VILLAGE POST MORTA DISTT GHAZIABAD U P PIN 201003 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201003 | L-5 | Rejected-Finance L-5 |
Tender Value
₹43.2 L
EMD Value
₹86,400
Closing Date
25 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
GE (AF) FARIDABAD
ADDITION/ALTERATION TO AIRMEN MESS AT AF STN CHANDINAGAR UNDER AOR OF GE (AF) FARIDABAD
2024_MES_671687_1
GE (FBD)/AF-53/2024-2025
Open Tender
Civil Works
Item Rate
180 days
Chandinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹86,400
Yes
10 Dec 2024
4 Sept 2024
30 Sept 2024
4 Sept 2024
25 Sept 2024
18 Sept 2024
4 Sept 2024 - 11 Sept 2024
Amount
Taking down of old existing roof treatment of any description incl scrub and remove loose concrete, brick tiles, mud phuska, plaster, bitumen, oil grases and any other materials that might effect adhesion by wire brushing the surface and cleaning of the surface throughly with water and disposed off old materials from site complete all as specified and directed.
M&L for 50 mm thick Plain cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in padding/ base on roof complete all as specified and directed.
M&L for 20 mm thick plastering in Cement Mortar (1:4) on RCC roof slab, finish even and smooth to recieve Water proofing APP membrane, using WPC @ 3% by weight of cement complete all as specified and directed. Note : WPC will be measured and paid separately.
Supply only Integral water proofing compound complete all as specified and directed.
Dismantling water tank of capacity exc. 500 and n.exc. 1000 ltrs and removal to store complete all as specified and directed.
Supply and fixing for 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed.
Supplying and laying of CPVC pipes, SDR 11 of outer dia. 20 mm and plain CPVC SDR 11 fittings in trenches including taking down of old GI pipes complete all as specified and directed.
Supplying and laying of CPVC pipes, SDR 11 of outer dia. 25 mm and plain CPVC SDR 11 fittings in trenches including taking down of old GI pipes complete all as specified and directed.
Supplying and laying of CPVC pipes, SDR 11 of outer dia. 32 mm and plain CPVC SDR 11 fittings in trenches including taking down of old GI pipes complete all as specified and directed.
Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc complete all as specified and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in Cement Mortar (1:6) complete all as specified and directed.
Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick Cement Mortar (1:6) on fair faces of brick or concrete surfaces of walls, facia etc to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 15 mm thick Cement Mortar (1:4) on fair faces of brick or concrete surfaces of walls, facia etc to be finished even and smooth (without using extra cement) complete all as specified and directed.
M & L for preparation of new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of chalk whiting as a preparatory to distempering complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment and applying two coats of exterior acrylic emulsion water based (weather proof coat) paint on wall complete all as specified and directed.
M&L for Complete removal of existing treatment from walls, fins, chajja etc shall include brooming down or steel wire brushing, scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots and removing debris/ malba to low lying area out side of MOD land and applying 3 to 5 mm thick a layer of Birla white wall care water proof putty on scrapped/uneven surfaces to match with the existing surfaces before application of primer/distemper and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shuttters from frames) size exc 1.5 Sqm but not exc 4 sqm each each and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shuttters from frames) size n .exc 1.5 Sqm and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and directed.
S&F powder coated aluminium frame of standard section for doors, windows , ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, side hung type / sliding without sash bars, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber packing , anodised aluminum snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 Nos) & suitable handle (1 No), complete all as specified and directed.
Supply and fixing anodised aluminium door shutters, aluminium section weighting 0.55 Kg/ RM including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed.
Supply and fixing ordinary quality sheet glass 5mm thick n exc 0.5 sqm in each pane, for panels of aluminium door and window etc, fixed with aluminium clip and rubber beading complete all as specified and directed.
Supply and fixing ordinary quality sheet glass 5mm thick exc 0.5 sqm in each pane, for panels of aluminium door and window etc fixed with aluminium clip and rubber beading complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supplying and fixing for toughened glass frameless partition, 12 mm thick Toughened Glass partitions upto 3.00 M with proper machine edge finish in angle & fixed in the flooring with Aluminium 'U' channel & flushed with the ceiling. Glass panels to be formed as per approved modules 12 mm thick clear toughened glass edge polished and accurate designed holes to be installed by means of steel angle or spider fittings of an approved. The structural Glass walls system shall be complete with proper water tight silicon sealants /gaskets. M.S Brackets to support the structure system shall be hot dipped galvanized and slots in the brackets to be pre-drilled not flame cut. All bolts,nuts,washers shall be 300 series non magnetic stainless steel and lock washers to be provided at all bolting connections. All anchor fasteners shall be of Hilti/Fisher make. All structural silicon shall be of Dow Corning make. The Rates includes all material, Labour, Wastages, Cost of scaffolding,fixing & Finishing with frosted design film etc complete all as specified and directed.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Supply and fixing in repair for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring, joints, laid in trenches or in floors or fixed to wall complete all as specified and directed.
Supply and fixing in repair for 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring, joints, laid in trenches or in floors or fixed to wall complete all as specified and directed.
S&F in repair for 150 mm bore PVC (SWR) single socketed rain water pipe, in any length with rubber ring joints fixed to walls/roof incl brackets/clamps etc complete all as specified and directed.
Supply and fixing in repair 15 mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
Supply and fixing in repair 15 mm bore chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed.
Supply and fixing in repair 15 mm bore chromium plated Stop/ angle valves, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed.
Supply and fixing for Low density polyethylene (LDPE) pipes of pressure rating 2.5 Kgf/Sqcm, 45cm long with and including two brass union couplings, heavy duty, suitable for 15mm bore pipe, one on each end for connecting polyethylene pipe to GI pipe and fixed complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness in floors, approns etc laid, bedded and pointed in any mortar and removing rubbish off the premises complete all as specified and directed.
Material and labour for pre-polished granite tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types including 20 mm thick bedding layer in Cement Mortar (1:6), complete all as specified and directed.
Material and labour for pre-polished granite stone tiles dado 20mm thick machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing of mirror finish type including 15 mm thick screed in CM 1 :4 on brick or concrete surface complete all as specified and directed.
Material and labour for machine cut pre-polished Kota stone slabs flooring 18 to 22 mm thick over 20 mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for grinding/polishing to existing terrazo/kota flooring by mechanical machine method complete all as specified and directed.
Material and labour for 18 to 22 mm thick machine cut pre-polished Kota stone slabs in riser of steps, skirting, dado and pillar etc, laid over 10 mm thick screed bed in Cement Mortar (1:4), jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
Dismantling floor hearth or wall tilling including cement mortar bedding (but not backaing coat) removing serviceable tiles to store & rubbish off the premises complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces 300 x 200 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over & including rendering 10 mm thick in cement mortar (1:4) on brick or concrete surface of wall to receive glazed tiles, complete all as specified and directed.
M&L for Non-skid ceramic tiles, dark coloured, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Material and labour for 100 mm thick Plain Cement concrete, type B-1(1:2:4) using 20mm graded stone aggregate as in pavement, finished even and fair, complete all as specified and directed.
Material and labour for 75 mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
Material and labour for vitrified Ceramic tiles 10mm thick Dark shade (Square/ rectangular) polished, area of each tiles n. exc 0.36 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Material and labour for vitrified Ceramic tiles 10mm thick Dark shade (Square/ rectangular) polished, area of each tiles n. exc 0.36 Sqm in vertical surface such as skirting, dado and risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar (1:4) on brick or concrete surfaces of wall to receive vertical tiles complete all as specified and directed.
S&F 75mm size brass handles, cast type polished bright, complete all as specified and directed.
S&F magnetic catcher for wooden cabinate shutters, compete all as specfied and directed
M&L in repair for 12 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed.
M&L in repair for 18 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed.
Supply and fixing in repairs continuous (piano) hinges, mild steel bright finish or electrogalvanised 30mm flaps, complete all as specified and directed.
Material and labour for preparation of old treated plastered surfaces of ceiling by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment and applying two coat of oil bound distemper on ceiling complete all as specified and directed.
M&L for coloured Chequered cement concrete tiles 300x300x25 mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over and including screed bed 20 mm thick in cement mortar (1:6) complete all as specified and directed.
S&F Framed work such as grills, gratings, etc,with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L for preparation of new or previously untreated surfaces of steel of any description , over 10 cm in width or girth not otherwise described applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed.
M&L for preparation of old treated plastered surfaces of wall by brooming down or steel wire brushing scrubbing down smoke soot, moulds, moss and efflorescence salts and treating oil and greasy spots removing dust, dirt and all loose scales of existing treatment and applying two coats of exterior acrylic emulsion water based (weather proof coat) paint on wall complete all as specified and directed.
Taking down carefully aluminium point wiring (light, Socket or power) complete including fittings and fixtures such as switches, ceiling roses pendents, regulators, sockets etc including making good the disturbed portion/surface, complete all as specified and directed.
M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated and unsheathed size 1.5 sqmm (FRLS)with PVC concealed conduit medium grade IS marked (dia not les than 25 mm) with fixing accessories for one light /fan/bell point controlled by one switch with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet incl. contineous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly complete all as specified and directed.
All as per item No 61 above but for one 3/5 pin socket 5 Amp on same board.
All as per item No 61 above but for one 3/5 pin socket 5 Amp on independent board with 2.5 sqmmwire with 2.5 sqmm earth wire .
All as per item No 61 above but for 3 pins socket outlet 15 Amps independent with 4.0 sq mm incl contineous earthing with multistandred copper conductor PVC insulated unsheathed size 4.0 Sq mm complete all as specified and directed. Note:- (For item 61 to 64 ) Cost for making good disturbed surface below existing point wiring taken out vide item No 60 and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjacent surface conduit and all accessories as required for concealed point wiring vide item No 61 to 64 as applicable shall be deemed to be included in the unit rate quoted against these items.
S&F switch piano flush type 5 Amps, single pole one way 230 Volts AC complete all as specified and directed
S&F socket 3/ 5 pins, 6 Amp, flush type piano (multi purpose) 230 Volts AC complete all as specified and directed.
S&F Socket 15 Amps flush type,3/ 6 Pin, 230 Volts , AC complete all as specified and directed.
S&F switch 15 Amps flush type 230 Volts , AC complete all as specified and directed.
S&F ceiling rose, PVC / Polycarbonate isolated body ,surface backlite, 65x50mm, three terminals, 230 Volts , AC complete all as specified and directed.
S&F stepped type electronic fan regulator flush type 230 Volts , AC complete all as specified and directed.
S&F Batten holder PVC/Polycarbonate base / back suitable for LED lamp. 230 Volts , AC complete all as specified and directed.
S&F LED Bulbs 9/10W B-22 Pin type 230 Volts , AC completeall as specified and directed.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket with one single pole 20 amps MCB complete all as specified and directed.
S&F LED tube light fittings 20W (4 feet) wall mounted LED batten extruded PVC heat sink provided for efficient heat dissipation & integrated electronic driver optics diffused complete including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed.
S&F LED 6000K (2’ feet), 10W Decorative LED lighting fixture with extruded PVC . heat sink, environmental friendly, energy efficient ready to use pack, complete and including taking down existing fittings complete all as specified and directed.
S&F LED building secuity light 25 watt made up of pressure die cast aluminium housing with mid power LED as lightening source and PC cover having top opening inbuilt LED driver with IP66 protection and impact resistance of IK-07 complete including GI bracket with nut bolts, washers etc including electrical connection with copper cable from ceiling rose to fittings and including taking down existing fittings complete all as specified and directed.
M&L for submain wiring with 2X4.0 SQMM+1X4.0SQMM Earth Wire single core PVC insulated FRLS sheathed copper conductor cable connecting to common earth dolly in and including heavy duty PVC concealed Conduit medium grade, ISI marked not less than 20 mm dia and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed.
M&L for submain wiring with 2X10.0 SQMM+1X10.0SQMM Earth Wire single core PVC insulated FRLS sheathed copper cable connecting to common earth dolly in and including heavy duty PVC concealed Conduit medium grade, ISI marked not less than 20 mm dia and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed.
M&L for submain wiring with 4X6.0 SQMM+2X6.0SQMM Earth Wire single core PVC insulated FRLS sheathed copper cable connecting to common earth dolly in and including heavy duty PVC concealed Conduit medium grade, ISI marked not less than 25 mm dia and dismantling and taking down existing unserviceable wiring, all accessories complete all as specified and directed. Note for item No 77 to 79 : (i) Two/Four runs copper wire for phase & neutral and One/Two run for earth wire with PVC Conduit respectively shall be measured one unit length. (ii) Cost of making good disturbed surface below existing wiring and cutting chases and making good of disturbed surfaces by cement & sand mortar (1:3) and surface finish as per adjacent surface conduit and all accessories as required for concealed as applicable shall deemed to be included in the unit rate quoted against these items.
S&F in repairs VTPN 4 way double door prewired distribution board TPN-DPX 125 MCCB including one No MCCB 125 Amps, 25 kA, 4 pole as incomer and suitable SPN/TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete and including taking down VTPN DB's all as specified and all as directed. Note : Rates of MCCB and MCB SPN/SP/TP shall deemed to be included in the quoted rates.
S & F in repairs single pole and neutral sheet metal enclosures for Distribution board (DB's)suitable for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail 240 V, 50 Hz supply double door SP&N DB system 12 ways complete all as specified.
S&F RCBOs for earth leakage,over load & short circuit protection 2 pole ,25 Amp rating, 300 mA capacity suitable for 240 Volts and including taking down existing old/unsv, complete all as specified and directed.
S&F MCB SPN 40-63 Amps 240V incl all termnials, fitting etc. including taking down existing MCB, complete all as specified and directed.
S&F MCB SP 06 to 40 Amps 240V incl all termnials, fitting etc including taking down existing MCB, complete all as specified and directed.
M&L for Refixing carefully serviceable fans / geysers etc any type from site on completion of civil and E/& M works incl making necessary connection with suitable copper wire and testing and incl taking down complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
All as per item No 86 but exceeding 1.5 mtr deep but not exc 3.0mtr deep.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed.
M&L for sub class `B` bricks for cable protection complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate, as in wall, retaining wall, pole, pit, foundation etc, complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in mass filling and coping of pole and strut, stay around the pole etc complete all as specified and directed.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Supply and errection in true vertical position steel tubular swaged pole type 410 co SP-31 (9 mtr long) complete with cast iron base plate and final tape plug, bolts, nuts, washers and screws incl painting with synthetic enameled aluminium paint two coat over one coat or red oxide primer after errection and providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete and marking pole number on pole complete all as specified and directed. Note : (i) Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
S&F for LED Street Light Luminaries 90 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed.
S & F of hot pressed moulded SMC boxes with hinged door fixing of size 325x220x150 mm with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 15 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion complete all as specified and directed.
36SHRI RADHEY ASSOCIATES (BID ID -3112465)
Singh Associates (BID ID -3113310)
laxmi enterprises (BID ID -3110857)
NAVEEN KUMAR TYAGI (BID ID -3111331)
H.B. Traders (BID ID -3112826)
M/S Yamin (BID ID -3112229)
SHRUTKIRTI ENGINEERS AND CONSULTANTS (BID ID -3106102)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .