Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.6 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹23.3 L+₹67,346 (2.98%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹24.8 L+₹2.2 L (9.64%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹27.5 L+₹4.9 L (21.8%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹30.1 L+₹7.6 L (33.5%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
30 May 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR AND MAINT OF COOLING APPLIANCES, CEILING FANS, EXHAUST FANS AND CONNECTED WORKS AND CERTAIN PETTY REPAIR TO E/M SERVICES TO VARIOUS BLDGS AT MIRAN SAHIB UNDER GE JAMMU
2023_MES_593117_1
GEJC-07/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹1 L
Yes
23 Jun 2023
4 May 2023
1 Jun 2023
4 May 2023
30 May 2023
18 May 2023
Amount
Charges for attending day to day / E/M petty complaint in respect repair / rectification of fault in electric fitting MCB DB's, internal wiring, LT Panel and fixture and rectify the faults and replacement of unserviceable any type of fitting / fixture, MCB's, any type, bakellite sheet restore the electric Supply and made the item functionable light point, fan point, socket point 5A/15A, switches, sockets, fan regulator, light fixtures any type of lamp, MCB DB's and all electrical accessories and day to day / door to door maintenance, making the points / accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 mtr) and other connected minor acessories. Work shall also include to check & removal of leakge in service connection/submains of houses as and as directed. The scope also include cutting of existing bakelite sheet to accommodate new wiring acessories all type electric fitting/fixture.
Note :Any other replacement of major items shall be measured & paid under respective items as Supply only. Fixing charge of fitting/fixture and MCB's of any type is deemed to be included in the above item.(a) Contractor representative/engineer will report to complaint cell for morning and afternoon to collect routine/urgent nature of complaint related to internal electric Supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower (two electrician and two helper) equipped with all sort of petty items such as insulation tape, galvanised screwes, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type od requisite T&P items to his tradesman. All routine/ urgent job received on job slip will be repaired & got signatue of user's and will be deposited to complaint cell with in 24hrs. In case of any delay in attending the complaint more than 12hrs after handing over of routine/urgent works, the contractor shall be liable to pay the penalty as per the item rate. (ii) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (iii) If the Contractor did not attend complaints a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount. (iv) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deems to included in the item for repairi.e. Electrician/Helper, as all the items of CA are to be Supply and fixed by the contractor. (v) Proper record (date wise) of complaints received & rectified by the contractor shall be produced for verification at the time of payment of each RAR/Bill. (vi) All the complaint slip,register and connected document will be provided by the contractor without any extra cost. (vii) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano, flush type single pole one way 5Amp, 240 volts ISI marked complete all as specified and directed .
Supply only Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed .
Supply only Switch socket outlet combined 5 pin 5 amp flush type , 240 volts ISI marked complete all as specified and directed.
Supply only Switch socket outlet combined 2 in 1 , 3 pin 5 amp and `15 amp flush type , 240 volts ISI marked complete all as specified and directed.
Supply only Socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed .
Supply only Ceiling Rose 3 terminal surface type complete all as specified and directed.
Supply only Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply only bell,AC 230Volts single pole complete all as specified and directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and directed.
Supply only holder any type for batten fitting ISI marked complete all as specified and directed complete all as specified and directed.
Supply only MCB SP 6 to 32 Amps,240 Volt B Series complete all as specified and directed.
Supply only SPN 32 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches,sockets, ceiling roses,bell push,bell electric,lamp holder,bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron,round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid/steel conduit and into existing CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per item No 19 here in above but One 5 pin socket outlet 5 amps on the same board complete all as specified and directed.
Description all as per item No 19 here in above but One 5 pin socket outlet, 5amps, independent complete all as specified and directed.
Description all as per item No 19 here in above but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into an including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including new CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per item No 23 here in above but 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per item No 23 here in above but socket outlet 5 Amps independent board complete all as specified and directed.
Description all as per item No 23 here in above but for one 6 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed.
Description all as per item No 23 here in above but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 5 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and directed.
Description all as per item No 23 here in above but drawn through an including new surface conduit PVC rigid non metalic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and directed.
Material and labour for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid/ 1.8mm wall thickness ISI marked including pressed steel with existing colour terminated boxes of Modular Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and directed. :- Note: suitable Module white cover sheets with frame as specified to be provided in replacement to MS/Galvanised sunken boxes and measured & paid separately as per relevant item. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.
Description all as per item No 29 here in above but 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per item No 29 here in above but socket outlet 5 Amps independent board complete all as specified and directed.
Description all as per item No 29 here in above but for one 6 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed.
Supply and fixing in replacement Modular switch 1 way 6A,1 module , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Modular switch 1 way 16A, 1 module , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Socket, 6A - 2/3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Socket 6A/16A - 2/3 pin combined 2 module, , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Fan step regulator, 120W 1 module , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Moduler white cover plate with frame 1 module complete all as specified , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Moduler white cover plate with frame 2 module complete all as specified , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Moduler white cover plate with frame 3 module complete all as specified , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Moduler white cover plate with frame 4 module complete all as specified , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Moduler white cover plate with frame 6 module complete all as specified , 240 volts ISI marked complete all as specified and directed
Supply and fixing in replacement Moduler white cover plate with frame 8 module complete all as specified , 240 volts ISI marked complete all as specified and directed
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as directed by Engr-in-Charge. Note:- Distribution board and MCBs should be same make.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed Note:- Distribution board and MCBs should be same make.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and directed Note:- Distribution board and MCBs should be same make.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed maganatic setting of cap 125 Amps 16 KA complete all as specified and directed
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed
Supply and fixing in repair SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing in repair 415V 10KA 'B' curve TPN 40 To 125 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing in replacement for switch piano, flush type single pole one way 5Amp, 240 volts complete all as specified and directed
Supply and fixing in repair for switch piano, flush type single pole one way 15 Amps, 240 volts complete all as specified and directed
Supply and fixing in replacement of Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed
Supply and fixing in repair for Socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and directed
Supply and fixing in replacement of Switch socket outlet combined 5 pin 5 amp flush type , 240 volts complete all as specified and directed
Supply and fixing in replacement Switch socket outlet combined 2 in 1 , 3 pin 5 amp and `15 amp flush type , 240 volts complete all as specified and directed
Supply and fixing in repair for bell push , flush type single pole , 5Amp, 240 volts complete all as specified and directed
Supply and fixing in repair Ceiling Rose 3 terminal surface type complete all as specified and directed
Material and labour in replacement for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed
Material and labour in replacement Self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and directed
Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95 , 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz. complete all as specified and directed
Supply and fixing in replacement Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing in replacement bulk head luminaries IP65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED Bulb complete all as specified and directed
Supply and fixing in replacement Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc.complete all as specified and directed
Supply and fixing in replacement Calling bell Ding Dong/buzzer AC 230 Volts, single pole complete all as specified and directed
Material and labour in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 4.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed Note : Wiring shall be done in proper colour coding.
Material and labour in replacement for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 4 Sqrmm for phase and neutral and one run of 2.5 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed Note : Wiring shall be done in proper colour coding.
Material and labour in replacement for Wiring for circuit with proper existing colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 1 run 2.5 Sqrmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall complete all as specified and directed Note : Wiring shall be done in proper colour coding.
Material and labour in replacement for Wiring for circuit with proper existing colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 1 run 1.5 Sqrmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall complete all as specified and directed Note : Wiring shall be done in proper colour coding.
Material and labour in replacement for Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed
Supply and fixing in replacement unsv wooden/CI Shunken box with new CRCA presseed steel terminal box of size 7X4' with cemented and patch work complete all as specified and directed
Supply and fixing in replacement unsv wooden/CI Shunken box with new CRCA presseed steel terminal box of size 4X4' with cemented and patch work complete all as specified and directed
Supply and fixing in replacement unsv wooden/CI Shunken box with new CRCA presseed steel terminal box of size 10X8' with cemented and patch work complete all as specified and directed
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (06 Nos each) of size 8''X5'' complete all as specified and directed
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (12 Nos each) of size 12''X10'' complete all as specified and directed
Supply and fixing in replacement Bakalite hylum Sheet 3 mm thick complete with cutting and making size for fixing switches (02 Nos each) of size 5''X5'' complete all as specified and directed
Supply and fixing in replacement plug top 15 Amps complete all as specified and directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar complete all as specified and directed Note:- (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCBs shall be measured and paid separately. (iii) TPN DB and MCCB should be of same make.
Supply and fixing in replacement PVC box (gang bx) surface mounted heavy duty 3 way complete with socket outlet 2 in 1 , 6 pin 5 amp 240 volt alongwith switch piano 5 amp 240 volt complete all as specified and directed
Supply and fixing in replacement PVC box (gang bx) surface mounted heavy duty 3 way complete with socket outlet 2 in 1 , 6 pin 5 amp 240 volt alongwith switch piano 15 amp 240 volts complete all as specified and directed
Notes :- (i) For Serial No 16 to 82 : The Contractor has to complete the work assigned for above items with in 72 hrs failing in which recovery at the rate 25 Rs. Per complaint per day. (ii) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deems to included in the item for repairi.e. Electrician/Helper, as all the items of CA are to be Supply and fixed by the contractor. (iii) Proper record (date wise) of complaints received & rectified by the contractor shall be produced for verification at the time of payment of each RAR/Bill. (iv) All the complaint slip,register and connected document will be provided by the contractor without any extra cost. (v) After any repair the site has to be cleaned and make the surface good.
Labour for repair/servicing of ceiling fan of any capacity complete with strip opening the ceilling fan for repair/washing/warnishing and removing of old lubricating sub Statance from bearing/bush using Kerosine oil, carying out fresh lubrication using grease and to make the ceiling Fan noise free for smooth funct ioing, including replacement of worn out/unserviceable minor spare parts split pin,fan body bolts,spring washer,fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire satisfication of engineer in charge and depositing in MES Store yard complete all as specified and directed (Replacement of Spares flexible wire etc/rewirding of ceiling fan/shall be measured and paid seperately under respective item for material and labour cost .)
Description all as per serial item No. 85 above but for exhaust Fan of any type mm sweep complete all as specified and directed
Description all as per item No. 85 above but for wall mounting Fan of any size/ type complete all as specified and directed
Rewinding of ceiling fan, of any make/type and size (1200/1400 mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection & testing complete all as specified and directed
Description all as per item No. 88 above but for exhaust fan of any make/type and size complete all as specified and directed
Description all as per item No. 88 above but for wall mounting fan of any make/type and size complete all as specified and directed
Labour for remetalling of worn out shaft of fan , cutting,brazing,machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer satifaction of engineer in change to ensure smooth and noise free operation complete all as specified and directed(bearing shall be measured and paid seperately )
Supply and fixing in repair ball bearing of any size and type, suitable for any type/make/size of ceiling Fan complete all as specified and directed
Supply and fixing in repair ball bearing for exhust fan of any type/make and size complete all as specified and directed
Supply and fixing in repair ball bearing for wall mounted fan of any type/Make and size complete all as specified and directed
Supply, fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and Rated capacity 2.5 MFD for ceilling fan,Exhaust Fan and Wall mounted Fan complete all as specified and directed
Description all as per item No. 95 above but of rated capacity 4.0 MFD for Exhaust Fan complete all as specified and directed
Supply and fixing in repair of PVC insulated, unsheathed multi stranded,three core twisted copper flexible cable of size 1.5 Sqmm as required complete all as specified and directed
Supply and fixing in repair only bush of suitable size for exhaust fan of any type/size as per existing type complete all as specified and directed
Description all as per item No. 98 above but suitable for wall mounted fan of any type/size as per existing type complete all as specified and directed
Supply and fixing in repair of PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and directed
Supply and fixing in repair of PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and directed
Supply and fixing in repair of GI/ MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole complete all as specified and directed
Supply and fixing in replacement MS clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts,split pin and washers suitable for housing ceiling fan complete all as specified and directed
Supply and fixing in replacement of ceiling fan down rod 12 mm dia and 30/45 cm long complete with MS Clamp Rubber reel,split pin nut bolts etc. complete all as specified and directed
Supply and fixing in replacement of louver shutter made of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made o MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground/first/second floor etc complete with using fastener bolt,driling,(spray painting) over a coat of primer for exhust fan up to 400 mm sweep complete all as specified and directed Note: Rates are deems to be including charges for hiring any type of T&P,Ladder,cutter etc (i) Contractor shell be responsible for life cover of staff deployed for fixing lover shutter.
Cleaning of ceiling fan assembly of any type/size and carrying out two coat of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint complete all as specified and directed
Description all as per item No.105 above but for exhaust fan upto 450 mm complete all as specified and directed
Supply and fixing in replacement PVC Canopy set of two pieces for ceiling fans of any size complete all as specified and directed
Repair to oscillation moving part of wall mounted fan including replacement of all wornout components, bearing , lubrication and assembling complete all as specified and directed
Supply and fixing in repair ceilling fan blades set of 3 pieces suitable for 1200/1400 mm sweep of white/brown/ivory colors complete all as specified and directed
Material and labour for repair/Maint to desert coolers complete with and including cleaning,scrapping/rubbing old rusted surface ,filling cavities and painting with two coat of high quality aluminium paint over a coat of red oxide primer externaly and black paint internally with synthetic enamelled paints complete with replacement of necessary nut,bolts,rubber pads for fan motors and writing MES No/unit name complete all as specified and directed
Supply and fixing in replacement of desert cooler fan motor 90 watt,1400 RPM,230 volt 50 Hz single phase conforming to ISI complete with fan blade and capacitor of sutitable size complete all as specified and directed
Supply and fixing in replacement of Desert Cooler submersible pumping set single phase 230 volt , 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead complete all as specified and directed
Supply and fixing in replacement of PVC accessories of desert cooler I.e. PVC pipe 20 mm dia heavy duty 2 mtr appx,PVC distributer 4 way with nut,bolts,PVC elbow-03 Nos,MS clamps etc complete all as specified and directed
Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from MS having duty complete with key bolt complete all as specified and directed
Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty MS Sheet and matching with the existing Desert Cooler body size complete with Khas Khas pads set of three peices complete all as specified and directed
Supply and fixing in replacement of Desert Cooler UNSV/leakage body made out from heavy duty MS Sheet bend to shape company manufacturer, complete with internal PVC accessories i.e. PVC elbow-03 Nos,PVC distributor 4 way-01 No, PVC distrbution pipe-2 mtr appx, Black painted internally, Aluminium painted externally complete with Provn of necessary arrangement for fixing front cover and fan motor complete all as specified and directed
Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 sqmm 3 core FRLS 230 volt,50 Hz conforming to ISI complete all as specified and directed
Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 sqmm 3 core FRLS 230 volt,50 Hz conforming to ISI complete all as specified and directed
Supply and fixing in replacement cable PVC insulated and sheathed of size 4.0 sqmm 3 core FRLS 230 volt,50 Hz conforming to ISI complete all as specified and directed
Supply and fixing in replacement of plug top 3 pin 5 Amp 230 volt 50 Hz complete all as specified and directed
Supply and fixing in replacement of PVC accessories of capacitor 2.5 MFD for Desert Cooler fan moter ,230 volt 50 Hz complete all as specified and directed
Supply and fixing in replacement of unsv Khas Khas/Glass wool for desert cooler Set of three peices complete all as specified and directed
Repair/Maint/Servicing to refrigerator/deep freezer/water coolers/AC's of any capacity and model by replacing capilary tubing,gas chargings,rectification of leakage in capillary tubing/Chiller plant/water tanks,condensing coils,repair to wiring,flushing/cleaning condensing/cooling coils/internal/External unit of split AC,greasing to blower motors,replacement of spare parts, fan belts and make refrigerator/deep freezer/water coolers/AC's in serviceable condition complete all as specified and directed Note:Spare/Gas charging paid seperatly.
Charges for fixing in replacement of unsv sealed seamless welding compressor unit company manufacturer of any capacity for AC's complete with initial filling/charging of refrigerant gas to meet the requirement complete with vibration rubber pads four nos each nut,bolts etc and testing on full load complete all as specified and directed (Spare parts shall be measured and pad seperatly under respective items) Note :- "Contractor Shall be responsible for all replacement of failed compressor and shall be accompanied by certificate from the original compressor to the effect that said compressor has been repaired at their authorised cervice center.Further, a warrenty of 12 month shall be provided on such replacement in writting."
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerent gas conforming to ISI as under:-
For refrigerator 165/286 Ltr capacity
For refrigerator 290/320 Ltr capacity
For Deep Freezer 100/200 Ltr capacity
For Deep Freezer 300/400 Ltr capacity
For Water Cooler 40/80 Ltr capacity
For Water Cooler 60/120 Ltr capacity
Split/Window AC 1.5 Ton Capacity
Split/Window AC 2.0 Ton Capacity
Supply and fixing in replacement of unsv/burnt condensing fan motor 1/35 HP Single phase 230 volt 50 Hz complete with blade,fan belts for water cooler of capacity 40/80 Ltr and 60/120 ltr complete all as specified and directed
Supply and fixing in repair of condensing fan motor 1/5 HP 1440 rpm Single phase 230 Volt 50 HZ with double blade and shaft end with fan belts for windows AC/Split AC conforming to ISI of capacity 1.5/2.0 ton complete with vibration parts etc complete all as specified and directed
Supply and charging refrigerant 134a/R-22 in sealed compressor unit of refrigerator/deep freezer/water coolers/AC's of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter,strainer complete all as specified and directed
Supply and fixing in replacement of following spare parts for refrigerator/deep freezer/water coolers/AC's of any capacity:
Starting relay
Overload protector
Thermostat switch
Defroz switch
Supply and fixing in replacement of following unsv spare parts of water cooler of any capacity
Starting capacitor 45 mfd
Running capacitor 60/120 mfd
Float valve PVC 15 mm dia with ball
Push cock chromium plated 15 mm with nipple 6'' long
Drain/Wash out flexible down pipe 40 mm dia
Water tank door gasket
Water drain tray of suitable size
Supply and fixing in replacement of unsv following spare parts of window/Split AC unit of capacity 1.5 to 2.0 ton
Starting capacitor 36/40 mfd
Running capacitor 100/120 mfd
PCB of Split AC
Front Grill cover for window AC 1.5 Ton
Condensing fan motor double shaft
Supply and fixing in replacement of PVC flexible braded pipe of 20 mm dia for Split AC water drain out all as specified and directed.
Supply and fixing in replacement of outer split AC condensing unit complete for Split AC 1.5 ton all as specified and directed.
Supply and fixing in replacement of inner unit of split AC complete with filters, blower motor etc for Split AC 1.5 ton complete with all accessories all as specified and directed.
Supply and fixing in replacement of copper capillary tubing 5/8'' for AC connection/repair complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular 10 sqmm
Supply and fixing in replacement of condensing unit of Refrigerator/Deep Freezer/Water Cooler of any capacity complete with cutting and brazzing work all as specified and directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 5 KVA complete all as directed .
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 3 KVA complete all as directed .
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 2 KVA complete all as directed .
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Vot of capacity 1 KVA complete all as directed .
Sarbat Construction Co
M/s Sahib Construction and engineers
M/S SALARIA ASSOCIATES
M/s Shakti Electric Works
M/S JIWANRISAM SERVICES PRIVATE LIMITED
G C BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .