Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹43.8 L+₹14.2 L (48.1%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹45.0 L+₹15.5 L (52.3%)Rejected-AOC C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹48.4 L+₹18.9 L (63.8%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹51.2 L+₹21.6 L (73.1%)Rejected-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L5 | Rejected-AOC REJECTED |
| Sl No | Description | Qty | Unit | Commercial Traders L2 | M/S Satyam Associates L3 | M/S VEDHANT ASSOCIATES L4 | PARM BUILDERS L1 | BRIJ MOHAN LAL AND CO. L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Schedule-A | ||||||||
| 1.01M&L for monthly Inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintenance as directed. Monthly Service : (a) Checking engine oil level and topping up as and when required . Note : Oil shall be measures and paid separately (b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid separately (c) Checking of oil bath air cleaner level (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element (g) Checking engine alternator coupling, mounting bolts and alignment (h) Tighting all nuts, bolts, in alternator terminal block (i) Checking of alternator carbon brush and connections in alternator (j) Checking and tighting of all connection in DC control wiring. (k) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately (l) Checking and recording oil pressure, water and oil temperature (m)Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately (n) Checking throttle linkage (o) Checking battery for cell test, electrolyte level, gravity and topping up to required level (p) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. (q) Checking of AMF panel, all electrical connections etc. (r) Checking of earthing resistance (s) Cleaning of vegetation around the DG set up to 1.5 mtr area. | ||||||||
| 1.02 | 400 KVA Capacity, Location : Tech Area Power House (Total 01 Nos) | 9 | Per Month | 8,000 ₹72,000 | 5,000 ₹45,000 | 10,000 ₹90,000 | 3,100 ₹27,900 Lowest | 5,010 ₹45,090 |
| 1.03 | 82.5 KVA Capacity, Location : Radar Lab, New STP, LLLRW (Total-03 Nos) | 27 | Per Month | 7,000 ₹1,89,000 | 5,000 ₹1,35,000 | 9,000 ₹2,43,000 | 2,450 ₹66,150 Lowest | 5,010 ₹1,35,270 |
| 1.04 | 62.5 KVA Capacity, Location : Booster Pump House (Total-01 Nos) | 9 | Per Month | 6,000 ₹54,000 | 5,000 ₹45,000 | 8,000 ₹72,000 | 1,850 ₹16,650 Lowest | 5,020 ₹45,180 |
| 1.05 | 40 KVA Capacity, Location : Madhur Millan Pump House, L-2 Switch at Tech Power House, Guard Room-(Total-03 Nos) | 27 | Per Month | 4,500 ₹1,21,500 | 5,000 ₹1,35,000 | 5,000 ₹1,35,000 | 1,250 ₹33,750 Lowest | 5,023 ₹1,35,621 |
| 1.06 | 25 KVA Capacity, Location : AFNet Tech HQ Bldg, Domestic Power House, (Total -02 Nos) | 18 | Per Month | 4,500 ₹81,000 | 5,000 ₹90,000 | 5,000 ₹90,000 | 850 ₹15,300 Lowest | 5,099 ₹91,782 |
| 2.00B' Check once in Six month OR 250 Hrs running of DG set whichever is Earlier Material and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :- Repeat the activities of 'Á' Check (a) Replacement of of lubricant oil. (Note:- Lub Oil are Paid separately.) (b) Replacing lubricant oil filter element with 'O' ring (c) Replacing fuel filter element (d) Replacing coolant. (e) Replacing Governor oil Notes : B Check kit, coolant shall and Lubricant oil shall be measured and paid separately under relevant items | ||||||||
| 2.01 | 400 KVA Capacity, Location : Tech Area Power House (Total 01 Nos) | 2 | Each Job | 7,000 ₹14,000 | 45,000 ₹90,000 | 8,000 ₹16,000 | 3,950 ₹7,900 Lowest | 45,010 ₹90,020 |
| 2.02 | 82.5 KVA Capacity, Location : Radar Lab, New STP, LLLRW (Total-03 Nos) | 6 | Each Job | 6,000 ₹36,000 | 20,000 ₹1,20,000 | 7,000 ₹42,000 | 2,950 ₹17,700 Lowest | 20,030 ₹1,20,180 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jun 2026, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon-122005
CA NO. GE AF NO.1 / GUR-50 / 2026-27 REPAIR / MAINTENANCE OF DIESEL GENERATING SET, SERVICE MAIN CABLE AT TECH AND DOMESTIC AREA EARTHING AND OTHER MISC E/M WORKS AT 13 BRD AND 16 BRD UNDER GE (AF) GURGAON NO.1.
2026_MES_769911_1
GE(AF) No 1/GUR-50/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Gurgaon No 1
ALL AS PER NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹80,000
Yes
20 Aug 2026
5 Jun 2026
27 Jun 2026
5 Jun 2026
25 Jun 2026
18 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Schedule-A | |||||
| 1.01 | M&L for monthly Inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintenance as directed.
Monthly Service :
(a) Checking engine oil level and topping up as and when required . Note : Oil shall be measures and paid separately
(b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid separately
(c) Checking of oil bath air cleaner level
(d) Checking of exhaust system for leakage
(e) Draining of sediment from fuel filter and fuel tank
(f) Cleaning of air cleaner element
(g) Checking engine alternator coupling, mounting bolts and alignment
(h) Tighting all nuts, bolts, in alternator terminal block
(i) Checking of alternator carbon brush and connections in alternator
(j) Checking and tighting of all connection in DC control wiring.
(k) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately
(l) Checking and recording oil pressure, water and oil temperature
(m)Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately
(n) Checking throttle linkage
(o) Checking battery for cell test, electrolyte level, gravity and topping up to required level
(p) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit.
(q) Checking of AMF panel, all electrical connections etc.
(r) Checking of earthing resistance
(s) Cleaning of vegetation around the DG set up to 1.5 mtr area. | - | - | - | - |
| 1.02 | 400 KVA Capacity, Location : Tech Area Power House (Total 01 Nos) | 9 | Per Month | - | - |
| 1.03 | 82.5 KVA Capacity, Location : Radar Lab, New STP, LLLRW (Total-03 Nos) | 27 | Per Month | - | - |
| 1.04 | 62.5 KVA Capacity, Location : Booster Pump House (Total-01 Nos) | 9 | Per Month | - | - |
| 1.05 | 40 KVA Capacity, Location : Madhur Millan Pump House, L-2 Switch at Tech Power House, Guard Room-(Total-03 Nos) | 27 | Per Month | - | - |
| 1.06 | 25 KVA Capacity, Location : AFNet Tech HQ Bldg, Domestic Power House, (Total -02 Nos) | 18 | Per Month | - | - |
| 2B' Check once in Six month OR 250 Hrs running of DG set whichever is Earlier Material and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :- Repeat the activities of 'Á' Check (a) Replacement of of lubricant oil. (Note:- Lub Oil are Paid separately.) (b) Replacing lubricant oil filter element with 'O' ring (c) Replacing fuel filter element (d) Replacing coolant. (e) Replacing Governor oil Notes : B Check kit, coolant shall and Lubricant oil shall be measured and paid separately under relevant items | |||||
| 2.01 | 400 KVA Capacity, Location : Tech Area Power House (Total 01 Nos) | 2 | Each Job | - | - |
| 2.02 | 82.5 KVA Capacity, Location : Radar Lab, New STP, LLLRW (Total-03 Nos) | 6 | Each Job | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TenderDocument50.pdf
Tender Documents • 1.50 MB
BOQ_862182.xls
BOQ • 1.10 MB
CorrDate50.pdf
PDF • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .