Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-Finance | ₹1.9 Cr | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹2.0 Cr+₹9.6 L (4.97%)Accepted-Finance | ₹2.0 Cr+₹9.6 L (4.97%) | L2 | Accepted-Finance L2 Bidder |
| 3 | L3₹2.1 Cr+₹14.2 L (7.39%)Accepted-Finance | ₹2.1 Cr+₹14.2 L (7.39%) | L3 | Accepted-Finance L3 Bidder |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-1. MSE submitted in irrelevant field for Tender Fee.
2. MSE submitted in irrelevant field for EMD
3. Bid Security submitted but tampered and backdated.
4. Financials not signed by Directors.
5. Blacklisting submitted backdated. |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Technical capacity documents not meeting the criteria. |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
9 Jul 2024, 4:00 pmClosed
CEO, Srinagar Smart City Ltd
1st Floor Budshah Building, Lal Chowk, Srinagar.
Electric Cabling, etc. of Maharaj Bazar Street and Goni Khan Market in Srinagar City-Cabling Work
2024_SSC_251544_1
E-N.I.T NO- 08-SSCL of 06-2024-25 DT- 28-06-2024
Open Tender
Electrical and Maintenance Works
Item Rate
75 days
Goni Khan and Maharaja Bazar Market
Refer to Bid Document
3 documents required · 3 mandatory
₹3,000
Yes
CEO Srinagar Smart City Ltd
₹5.0 L
Yes
13 Aug 2024
29 Jun 2024
10 Jul 2024
29 Jun 2024
9 Jul 2024
29 Jun 2024
Amount
Electrical Work
11KV Single core 400 sqmm Aluminium round wire Armoured XLPE Cable, FRLS (One spare cable)
11KV Single core 120 sqmm Aluminium round wire Armoured XLPE Cable, FRLS (One spare cable)
400 sqmm 11 KV Grade XLPE insulated FRLS 3.5 Core Armoured Cable Aluminium stranded conductor
185 sqmm 11 KV Grade XLPE insulated FRLS 3.5 Core Armoured Cable Aluminium stranded conductor
95 sqmm 11 KV Grade XLPE insulated FRLS 3.5 Core Armoured Cable Aluminium stranded conductor
50 sqmm 11 KV Grade XLPE insulated FRLS 4 Core Armoured Cable Aluminium stranded conductor
25 sqmm 11 KV Grade XLPE insulated FRLS 4 Core Armoured Cable Aluminium stranded conductor
16 sqmm 2 Core XLPE Service cable Armoured with Aluminium stranded conductor
25 sqmm 2 Core XLPE Service cable Armoured with Aluminium stranded conductor
3 phase 415V 1 No of 250Amp incommer 3 TP MCCB 25KA fitted with outgoing 1 No 100Amp 3 Pole MCCB, 11 No 63Amp DP for outgoing LT service lines, Distribution feeder pillar suitable for outdoor installation, made out of CRCA 2mm/1.6mm sheet painted through 7 tank process with PU painted Aluminium busbars 4P, Aluminium with heat shrinkable sleeves and adequate capacity complete with all accessories 12 way Distribution Feeder pillar, 630Amp main busbar for loop in loop out and 250Amp Aluminium busbar for service line connections.
3 phase 415V 1 No of 250Amp incommer 3 TP MCCB 25KA fitted with outgoing 1 No 100Amp 3 Pole MCCB, 3 No 63Amp DP for outgoing LT service lines, Distribution feeder pillar suitable for outdoor installation, made out of CRCA 2mm/1.6mm sheet painted through 7 tank process with PU painted Aluminium busbars 4P, Aluminium with heat shrinkable sleeves and adequate capacity complete with all accessories 4 way Distribution Feeder pillar, 630Amp main busbar for loop in loop out and 250Amp Aluminium busbar for service line connections.
Factory made CPRI certified with latest amended IEC approved by PDD, wall mount Outdoor/Indoor type LT panel of size 900x900x300 mm suitable for 415 V, 3phase, 4 wire,50 HZ,AC supply system having 1 No 400 A 36 KA 4P MCCB, 1 no Aluminium Busbar 400 A .The panel shall be dust and vermin proof IP 44 made out of 1.6 mm CR sheet, powder coated not less than 80 micron , including RYB indication and all other wiring as required.
Factory made CPRI certified with latest amended IEC approved by PDD, wall mount Outdoor/Indoor type LT panel suitable for 415 V, 3phase, 4 wire, 50 HZ, AC supply system having 1 No Aluminium Busbar 250 A.The panel shall be dust and vermin proof IP 44 made out of 1.6 mm CR sheet, powder coated not less than 80 micron , including RYB indication and all other wiring as required.
Outdoor Cable termination kits for 400,185,95,50,25 sqmm XLPE 3.5 Core cables
Outdoor Cable termination kits for 400,120 sqmm 11KV XLPE Single Core cables
Route Marker
Warning Tape
Excavation in any type of soil, backfilling, sand for cushioning, reinstatement of the excavated patch, restoring to its original position
Earthing complete by GI pipe 40mm or GI rod 20mm 3mtr long through GI strip (25x3) mm
Support Galvanised angle frame with dimensions (50mmx50mmx6mm) with leg height 1 Mtr for distribution feeder pillars @4.50kg/mtr
Cement grouting for supporting angle legs
HDPE 110mm
HDPE 50mm
Thimbles for 400,185,95,50,25,16 sqmm cables, cable glands, Steel cable tray, PVC channels/Cable tray for service lines, skirting for feeder pillars, nuts bolts and other allied accessories
Shifting of 11/0.433 KV,630KVA 3 phase distribution transformer to adjacent location using 4 No 9 mtr poles ST -410 SP 33, 11KV GO, AB Switch, Surge arrestor, LA, Horn Gap, Fuse set, 400/300 sqmm 1.1 KV single core XLPE FRLS Unarmoured cable, LT Distribution box with 400/250Amp MCCB for 4 outgoing LT circuits with suitable Aluminium busbars, Disc insulators, GI Channels, Galvanised Nuts and Bolts, Pin insulators, PG Clamps, Danger plates, barbed wire, Cement bottoming, earthing of poles, painting and all accessories(Complete Job) as per the direction of Engineer Incharge
Shifting of 11/0.433 KV, 400KVA 3 phase distribution transformer to adjacent location using 4 No 9 mtr poles ST -410 SP 33, 11KV GO, AB Switch, Surge arrestor, LA, Horn Gap, Fuse set, 400/300 sqmm 1.1 KV single core XLPE FRLS Unarmoured cable, LT Distribution box with 400/250Amp MCCB for 4 outgoing LT circuits with suitable Aluminium busbars, , Disc insulators, GI Channels, Galvanised Nuts and Bolts, Pin insulators, PG Clamps, Danger plates, barbed wire, Cement bottoming, earthing of poles, painting and all accessories(Complete Job) as per the direction of Engineer Incharge
Shifting of consumer Meter/ (Conventional / Smart) from existing pole to LT Feeder Pillars (including connectioning & proper arrangement)
PART-2 LIGHTING FIXTURES
Post top fixture- Supply installation testing & commissioning of exterior rated posttop of system lumen output should not be less than 2000 lumen (Tolerance ±15%), the power consumption should not be more than 50 watts, 360° symmetrical optics, CCT 3000K. Single piece with circular shaped plant made of die cast aluminum using pressure die-casting process,with a decorative Top luminaire which is also made of die cast aluminum using pressure die-casting process, fixed on the top.Auxiliary and optical compartment can be accessed by tilting the top frame. Bottom frame in single piece, made of die cast aluminum using pressure die-casting process with a three curved uprights decorated which is also made of die cast aluminum using pressure die-casting process, fixed at the bottom with a hole (28 mm) for fixing to support. Frosted Screen made of polymethylmethacrylate (PMMA) moulded in a single piece using Injection moulding process. Screen's Impact resistance: IK06. Pure polyester powder coating in the same color as of the pole/as per the lighting consultant. Optical Compartment IP Rating - IP 66. Height – 800mm, Dia. - 400mm, Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 4kv(an additional surge protection device of 10kV also provided in-built the fixture). Modular (2 X 2) refractive lens in PMMA with Type-II/III/IV photometric distribution options. protection screen in extra-clear tempered glass with impact resistance IK 08.LM80 (All the technical parameters of luminaire need approval from lighting designer)
Pos top pole- Supply and erection of 5000mm high decorative pole made out MS Pipe Ø76.1mm confirming to YSt 210 and facilitating the luminaire mounting at the top. The pole shall be surface mounted on a concrete foundation. The base plate of the of the pole shall be E 250 grade MS 200 mm x 200mm, 12mm thick confirming to IS2062:2011 shall be facilitated with elongated slots to suit the 300mm, J-type, M16 bolts, Grade 4.6 that shall be provided with suitable nuts and plain washers. The structurally sound pole emerging out of the base plate shall be architecturally designed with a decorative cast aluminium causeway base cover minimum Ø330mm x 500mm (H), above which the leaf decoration cast aluminium structure Ø 150mm is aesthetically positioned. Mounted flower pot. The grade of pressure diecast material shall be ADC12. A GDC embellishment is provided at appropriate height enhancing the decorative outlook of the pole. The grade of gravity die cast material shall be LM6. The Pole welding shall be done with certified welders using a V groove technique with a high end MIG welding process. A base compartment with a die cast aluminium door contoured to the poles's shape housing the gear tray, prewired with 2 way connector. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thoroughremoval of impuritise like, rust, oxides and other unwanted particles from the suface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating or epoxy zinc phosphate primer followed by the environmentally stable Polyurethane based paint. Pole must be connected to earthing. (All the technical parameters of luminaire need approval from lighting designer)
Providing and erecting galvanised 1000mm double armed sword type decorative bracket MS zinc coated
Supply installation testing & commissioning of exterior-rated architectural surface mounted IP67, neon flex in alluminum profile with mounting brackets/clamps (as per application). The power consumption should not be more than 5 watts per meter, System lumen output should not be less than 300 lumens per meter (Tolerance ±15%), diffused, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of exterior rated 1000mm long floor recessed marker light IP68, (as per application). System lumen output should not be less than 250 lumens (Tolerance ±15%), The power consumption should not be more than 20 watts, diffused , CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of exterior-rated architectural wall mounted IP67, led up & down light fixture with brackets/clamps (as per application). The power consumption should not be more than 2 x 5 watts, System lumen output should not be less than 2 x 300 lumens (Tolerance ±15%), up & down 30 degree beam angle, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of exterior rated pole mounted flood light IP67, (as per application). System lumen output should not be less than 1800 lumen with snoot (Tolerance ±15%), The power consumption should not be more than 30 watts, 30°/10° beam angle with tolerance of ±15%, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be included non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP67 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supply and erection of 10 meter high pole made out MS Pipe Ø76.1mm confirming to YSt 210 and facilitating the luminaire mounting at the top. The pole shall be surface mounted on a concrete foundation. The base plate of the of the pole shall be E 250 grade MS 200 mm x 200mm, 12mm thick confirming to IS2062:2011 shall be facilitated with elongated slots to suit the 300mm, J-type, M16 bolts, Grade 4.6 that shall be provided with suitable nuts and plain washers. The structurally sound pole emerging out of the base plate shall be architecturally designed with a decorative cast aluminium causeway base cover minimum Ø330mm x 500mm (H), above which the leaf decoration cast aluminium structure Ø 150mm is aesthetically positioned. Mounted flower pot. The grade of pressure diecast material shall be ADC12. A GDC embellishment is provided at appropriate height enhancing the decorative outlook of the pole. The grade of gravity die cast material shall be LM6. The Pole welding shall be done with certified welders using a V groove technique with a high end MIG welding process. A base compartment with a die cast aluminium door contoured to the poles's shape housing the gear tray, prewired with 2 way connector. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thoroughremoval of impuritise like, rust, oxides and other unwanted particles from the suface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating or epoxy zinc phosphate primer followed by the environmentally stable Polyurethane based paint. Pole must be connected to earthing. (All the technical parameters of luminaire need approval from lighting designer)
Supply installation testing & commissioning of interior rated ceiling surface mounted led light IP54, (as per application). System lumen output should not be less than 1500 lumens (Tolerance ±15%), The power consumption should not be more than 18 watts, diffused, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be anthracite gray where the luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, and SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, connectors are inclusive. Minimum IK06. The operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware for the successful operation of the luminaire. (All the technical parameters of the luminaire need approval from the lighting designer)
Supply installation testing & commissioning of exterior rated architectural floor/wall mounted IP66, 1000mm long linear light complete with visor and adjustable mounting brackets/clamps (as per application). The power consumption should not be more than 18 watts, System lumen output should not be less than 1500 lumen (Tolerance ±15%), 10°x25° beam angle with tolerance of ±15%, CCT 3000K. The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80, SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. Leader cables, jumper cables, IP66 connectors are inclusive. Minimum IK06. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. All mounting accessories shall be stainless steel (Minimum -316) for all lighting fixtures. The luminaire should be BIS certified. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the luminaire. (All the technical parameters of luminaire need approval from lighting designer)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as Required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Siingle pole)
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. 63A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Group A
Group B
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
2 pairs
Cat-6 cable
TZ Engineering Works
M/S R R ELECTRICAL SERVICES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .