| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | ₹46.4 L Quoted ₹46.5 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹47.9 LRejected-Finance | ₹47.9 L | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹58.0 LRejected-Finance | ₹58.0 L | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S RAKESH TRADERS L3 | PRAGATI ELECTRICALS AND ELECTRONICS L2 | M/s H V Infra Projects L1 |
|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | ||||||
| 1.10 | Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with AMF panel with suitable size of double contactor, MCCB, Relay with Battery Charger and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB-IV+ norms and foundation etc. of capacity 15 KVA the Disel Engine comprsing followings:- | 1 | Each | 5,50,000 ₹5.5 L | 4,00,000 ₹4 L | 5,23,000 ₹5.2 L |
| 1.20(A) DIESEL ENGINE:- Three cylinders inline, Liquid Cooled, Turbo charged and Developing 20.5 hp @ 1500 RPM. Our Gas Engines are with Electric Start, Compression Ignition, 4 Stroke Cycle , Designed to run continuously at 1500 RPM . It confirms to IS 10002, ISO-3046, BS 5514 standards. All Gas Engines are comply with Latest CPCB IV+ norms. The Gas Engines are comprising of followings: - Radiator with Fan , Fuel Injection equipments with mechanical governor, dry type Air cleaner, exhaust silencer, Lube Oil filter (Spin On Type), Fuel Oil filter (Spin On Type), 12V Electric starting system, Battery charging alternator, Stop Solenoid, Cylinder Head temperature Gauge, Battery Voltage, First Fill Lube Oil | ||||||
| 1.30B) ALTERNATOR:- Alternator, suitable for continuous duty operations rated at 1500 RPM 415 V, 0.8 PF, 50Hz, 3Phase in SPDP Enclosure, Self- Excited & Self- regulated, Brush less, ‘H’ class Insulation, floor mounted with anti frication Shielded Ball Bearing on end. The alternator conforms to IS: 4722, BS EN 60034-1 suitable for tropical conditions. | ||||||
| 1.40C) BASE FRAME:- Suitable to couple above Engine & Alternator made from mild steel sheet with suitable thickness of sheet as per OEM recommended. | ||||||
| 1.50D) FUEL TANK :- Suitable to 12 Hrs stoarge capacity for continuous running, with Diesel fuel Inlet & Outlet, Air Vent & Drain plug arrangements. | ||||||
| 1.60E) BATTERY:- 1 No 12 V Battery 120 AH with Leads. | ||||||
| 1.70F) STANDARD GENSET CONTROLLER UNIT WITH CONTROL PANEL:- Genset Controller unit with totally enclosed, Steel Construction Control Panel suitable for indoor floor / wall mounting installation having following safeties and display parameters: - Phase Voltage, Line current, Frequency, Average Voltage, Average Current, Current , Phase kW & Total kW, kWH, kVA, kVAR, PF, Engine Temperature, Engine speed, Battery Voltage, Engine Hours, No. of Starts, Genset Under/Over voltage, Under/Over Battery voltage, Under/Over Frequency, Phase Failure, Phase sequence reverse, Over Current., Over kW, Phase Voltage, Low Lube oil pressure, High Lube oil Temperature, Start/Stop fail, Battery Charging Alternator fail. | ||||||
| 1.80Note:- (i) Provision of PCC Platform as per manufactureres guidelines/specifications and shall be of required size. The cost of PCC shall be paid and measured seperately. (ii) Testing of the DG set shall be carried out by the contractor in the presence of IEM. (iii) The contarctor shall submit specification and drawing for approval of the GE before procurement of the DG set. (iv) Resistive load whether water load or strip heaters or suitable capacity and POL/DHPP for testing of DG set to be made available during test by the contractor. Testing of DG Set shall be carried out for continuous 12 hrs after installation of the site and if test fail during testing the same shall be again carried out by the contractor on his own arrangement.The cost of the same shall be deemed to be included in the unit quoted rates. (v) The DG set shall be procured from authorized OEM and of same group. The acoustic panel shall be manufactured by the same OEM. (vi) The cost of the external MS fuel tank if required for 12 Hours continious running shall be deemed to be included in the quoted rates. (vii) Suitable to Bhopal climate condition and derating factor acoording to the MSL of Bhopal. | ||||||
| 2.00 | Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete withAMF panel with suitable size of double contactor, MCCB, Relay with Battery Charger and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity 50 KVA , CRDi Four Cylinders Inline, Liquid Cooled, Turbocharged
and Developing not less than 70 HP @ 1500 RPM. Our Diesel Engines are with Electric Start, Compression Ignition, 4 Stroke Cycle , Designed to run continuously at 1500 RPM . It confirms to IS 10002, ISO-3046, BS 5514 standards. All Diesel Engines are comply with Latest CPCB-IV+ norms. The Diesel Engines are comprising of followings: - | 1 | Each | 9,70,000 ₹9.7 L | 7,00,000 ₹7 L | 9,28,000 ₹9.3 L |
Tender Value
₹49.7 L
EMD Value
₹99,500
Closing Date
11 Apr 2026, 6:00 pmClosed
GE BHOPAL
GE OFFICE BAIRAGARH BHOPAL PIN 462030
SPECIAL REPAIR TO BER W S AND E S EQUIPMENTS UNDER GE BHOPAL
2026_MES_757123_1
8552/E8
Open Tender
Civil Works - Water Works
182 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE BHOPAL
₹99,500
Yes
22 Jun 2026
20 Mar 2026
13 Apr 2026
20 Mar 2026
11 Apr 2026
3 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with AMF panel with suitable size of double contactor, MCCB, Relay with Battery Charger and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB-IV+ norms and foundation etc. of capacity 15 KVA the Disel Engine comprsing followings:- | - | Each | - | - | |
(A) DIESEL ENGINE:- Three cylinders inline, Liquid Cooled, Turbo charged and Developing 20.5 hp @ 1500 RPM. Our Gas Engines are with Electric Start, Compression Ignition, 4 Stroke Cycle , Designed to run continuously at 1500 RPM . It confirms to IS 10002, ISO-3046, BS 5514 standards. All Gas Engines are comply with Latest CPCB IV+ norms. The Gas Engines are comprising of followings: - Radiator with Fan , Fuel Injection equipments with mechanical governor, dry type Air cleaner, exhaust silencer, Lube Oil filter (Spin On Type), Fuel Oil filter (Spin On Type), 12V Electric starting system, Battery charging alternator, Stop Solenoid, Cylinder Head temperature Gauge, Battery Voltage, First Fill Lube Oil | - | - | - | - | |
B) ALTERNATOR:- Alternator, suitable for continuous duty operations rated at 1500 RPM 415 V, 0.8 PF, 50Hz, 3Phase in SPDP Enclosure, Self- Excited & Self- regulated, Brush less, ‘H’ class Insulation, floor mounted with anti frication Shielded Ball Bearing on end. The alternator conforms to IS: 4722, BS EN 60034-1 suitable for tropical conditions. | - | - | - | - | |
C) BASE FRAME:- Suitable to couple above Engine & Alternator made from mild steel sheet with suitable thickness of sheet as per OEM recommended. | - | - | - | - | |
D) FUEL TANK :- Suitable to 12 Hrs stoarge capacity for continuous running, with Diesel fuel Inlet & Outlet, Air Vent & Drain plug arrangements. | - | - | - | - | |
E) BATTERY:- 1 No 12 V Battery 120 AH with Leads. | - | - | - | - | |
F) STANDARD GENSET CONTROLLER UNIT WITH CONTROL PANEL:-
Genset Controller unit with totally enclosed, Steel Construction Control Panel suitable for indoor floor / wall mounting installation having following safeties and display parameters: -
Phase Voltage, Line current, Frequency, Average Voltage, Average Current, Current , Phase kW & Total kW, kWH, kVA, kVAR, PF, Engine Temperature, Engine speed, Battery Voltage, Engine Hours, No. of Starts, Genset Under/Over voltage, Under/Over Battery voltage, Under/Over Frequency, Phase Failure, Phase sequence reverse, Over Current., Over kW, Phase Voltage, Low Lube oil pressure, High Lube oil Temperature, Start/Stop fail, Battery Charging Alternator fail. | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
CREDIT8552.pdf
Tender Documents • 0.07 MB
TENDER_DOCU_8552.pdf
Tender Documents • 0.79 MB
BOQ_848083.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid